Changes for page NSPH01-NB-IoT Soil pH Sensor User Manual
Last modified by Bei Jinggeng on 2024/03/30 17:53
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. David1 +XWiki.Xiaoling - Content
-
... ... @@ -1,10 +1,16 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:)YK]Y_LZJIO]J2~~VA}OQJM2.png]] 3 3 4 - =**1.Introduction**=4 +**Table of Contents:** 5 5 6 - == **1.1 Whatis NSPH01 Soil pH Sensor** ==6 +{{toc/}} 7 7 8 + 9 + 10 += 1. Introduction = 11 + 12 +== 1.1 What is NSPH01 Soil pH Sensor == 13 + 8 8 The Dragino NSPH01 is a **NB-IOT soil ph sensor** for IoT of Agriculture. It is designed to measure the soil PH and soil temperature, so to send to the platform to analyze the soil acid or alkali level. The probe is IP68 waterproof. 9 9 10 10 NSPH01 probe is made by Solid AgCl reference electrode and Pure metal pH sensitive electrode. It can detect soil's** pH **with high accuracy and stable value. The NSPH01 probe can be buried into soil for long time use. ... ... @@ -14,4 +14,665 @@ 14 14 \\NSPH01 is powered by **8500mAh Li-SOCI2 battery**, It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 15 15 \\To use NSPH01, user needs to check if there is NB-IoT coverage in local area and with the bands NSPH01 supports. If the local operate support it, user needs to get a **NB-IoT SIM card** from local operator and install NSPH01 to get NB-IoT network connection. 16 16 17 - 23 +(% style="text-align:center" %) 24 +[[image:image-20220907153151-1.png]] 25 + 26 +(% style="text-align:center" %) 27 +[[image:M_K`YF9`CAYAE\@}3T]FHT$9.png]] 28 + 29 +== 1.2 Features == 30 + 31 +* NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD 32 +* Monitor soil pH with temperature compensation. 33 +* Monitor soil temperature 34 +* PH and Temperature alarm function 35 +* Monitor Battery Level 36 +* Support pH calibration by end user 37 +* Uplink on periodically 38 +* Downlink to change configure 39 +* IP66 Waterproof Enclosure 40 +* IP68 rate for the Sensor Probe 41 +* Ultra-Low Power consumption 42 +* AT Commands to change parameters 43 +* Micro SIM card slot for NB-IoT SIM 44 +* 8500mAh Battery for long term use 45 + 46 +== 1.3 Specification == 47 + 48 +**Common DC Characteristics:** 49 + 50 +* Supply Voltage: 2.1v ~~ 3.6v 51 +* Operating Temperature: -40 ~~ 85°C 52 + 53 +**NB-IoT Spec:** 54 + 55 +* - B1 @H-FDD: 2100MHz 56 +* - B3 @H-FDD: 1800MHz 57 +* - B8 @H-FDD: 900MHz 58 +* - B5 @H-FDD: 850MHz 59 +* - B20 @H-FDD: 800MHz 60 +* - B28 @H-FDD: 700MHz 61 + 62 +== 1.4 Probe Specification == 63 + 64 +**Soil pH:** 65 + 66 +* Range: 3 ~~ 10 pH 67 +* Resolution: 0.01 pH 68 +* Accuracy: ±2% under (0~~50 ℃, Accuracy will poor under 0 due to frozen) 69 +* Temperature Compensation Range: 0 ~~ 50℃ 70 +* IP68 Protection 71 +* Length: 3.5 meters 72 + 73 +**Soil Temperature:** 74 + 75 +* Range -40℃~85℃ 76 +* Resolution: 0.1℃ 77 +* Accuracy: <±0.5℃(-10℃~40℃),<±0.8℃ (others) 78 +* IP68 Protection 79 +* Length: 3.5 meters 80 + 81 +== 1.5 Applications == 82 + 83 +* Smart Agriculture 84 + 85 +== 1.6 Pin mapping and power on == 86 + 87 +(% style="text-align:center" %) 88 +[[image:image-20220907153300-2.png]] 89 + 90 + 91 += 2. Use NSPH01 to communicate with IoT Server = 92 + 93 +== 2.1 How it works == 94 + 95 +The NSPH01 is equipped with a NB-IoT module, the pre-loaded firmware in NSPH01 will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined by NSPH01. 96 + 97 +The diagram below shows the working flow in default firmware of NSPH01: 98 + 99 +(% style="text-align:center" %) 100 +[[image:image-20220907153416-3.png]] 101 + 102 +== 2.2 Configure the NSPH01 == 103 + 104 +=== 2.2.1 Test Requirement === 105 + 106 +To use NSPH01 in your city, make sure meet below requirements: 107 + 108 +* Your local operator has already distributed a NB-IoT Network there. 109 +* The local NB-IoT network used the band that NSPH01 supports. 110 +* Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 111 + 112 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NSPH01 will use CoAP(120.24.4.116:5683) or raw UDP(120.24.4.116:5601) or MQTT(120.24.4.116:1883)or TCP(120.24.4.116:5600)protocol to send data to the test server 113 + 114 +(% style="text-align:center" %) 115 +[[image:image-20220907153445-4.png]] 116 + 117 + 118 +=== 2.2.2 Insert SIM card === 119 + 120 +Insert the NB-IoT Card get from your provider. 121 + 122 +User need to take out the NB-IoT module and insert the SIM card like below: 123 + 124 +(% style="text-align:center" %) 125 +[[image:image-20220907153505-5.png]] 126 + 127 +=== 2.2.3 Connect USB – TTL to NSPH01 to configure it === 128 + 129 +User need to configure NSPH01 via serial port to set the **Server Address** / **Uplink Topic** to define where and how-to uplink packets. NSPH01 support AT Commands, user can use a USB to TTL adapter to connect to NSPH01 and use AT Commands to configure it, as below. 130 + 131 +**Connection:** 132 + 133 + USB TTL GND <~-~-~-~-> GND 134 + 135 + USB TTL TXD <~-~-~-~-> UART_RXD 136 + 137 + USB TTL RXD <~-~-~-~-> UART_TXD 138 + 139 +In the PC, use below serial tool settings: 140 + 141 +* Baud: **9600** 142 +* Data bits:** 8** 143 +* Stop bits: **1** 144 +* Parity: **None** 145 +* Flow Control: **None** 146 + 147 +Make sure the switch is in FLASH position, then power on device by connecting the jumper on NSPH01. NSPH01 will output system info once power on as below, we can enter the **password: 12345678** to access AT Command input. 148 + 149 +(% style="text-align:center" %) 150 +[[image:image-20220907153529-6.png]] 151 + 152 +**Note: the valid AT Commands can be found at: **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 153 + 154 +=== 2.2.4 Use CoAP protocol to uplink data === 155 + 156 +**Note: if you don't have CoAP server, you can refer this link to set up one: **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 157 + 158 +**Use below commands:** 159 + 160 +* **AT+PRO=1** ~/~/ Set to use CoAP protocol to uplink 161 +* **AT+SERVADDR=120.24.4.116,5683 ** ~/~/ to set CoAP server address and port 162 +* **AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** ~/~/Set COAP resource path 163 + 164 +For parameter description, please refer to AT command set 165 + 166 +(% style="text-align:center" %) 167 +[[image:image-20220907153551-7.png||height="502" width="740"]] 168 + 169 +After configure the server address and **reset the device** (via AT+ATZ ), NSPH01 will start to uplink sensor values to CoAP server. 170 + 171 +(% style="text-align:center" %) 172 +[[image:image-20220907153612-8.png||height="529" width="729"]] 173 + 174 + 175 +=== 2.2.5 Use UDP protocol to uplink data(Default protocol) === 176 + 177 +This feature is supported since firmware version v1.0.1 178 + 179 +* **AT+PRO=2 ** ~/~/ Set to use UDP protocol to uplink 180 +* **AT+SERVADDR=120.24.4.116,5601 ** ~/~/ to set UDP server address and port 181 +* **AT+CFM=1 ** ~/~/If the server does not respond, this command is unnecessar 182 + 183 +(% style="text-align:center" %) 184 +[[image:image-20220907153643-9.png||height="401" width="734"]] 185 + 186 +(% style="text-align:center" %) 187 +[[image:image-20220907153703-10.png||height="309" width="738"]] 188 + 189 + 190 +=== 2.2.6 Use MQTT protocol to uplink data === 191 + 192 +This feature is supported since firmware version v110 193 + 194 +* **AT+PRO=3 ** ~/~/Set to use MQTT protocol to uplink 195 +* **AT+SERVADDR=120.24.4.116,1883 ** ~/~/Set MQTT server address and port 196 +* **AT+CLIENT=CLIENT ** ~/~/Set up the CLIENT of MQTT 197 +* **AT+UNAME=UNAME **~/~/Set the username of MQTT 198 +* **AT+PWD=PWD **~/~/Set the password of MQTT 199 +* **AT+PUBTOPIC=NSE01_PUB **~/~/Set the sending topic of MQTT 200 +* **AT+SUBTOPIC=NSE01_SUB ** ~/~/Set the subscription topic of MQTT 201 + 202 +(% style="text-align:center" %) 203 +[[image:image-20220907153739-11.png||height="491" width="764"]] 204 + 205 +(% style="text-align:center" %) 206 +[[image:image-20220907153751-12.png||height="555" width="769"]] 207 + 208 +MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 209 + 210 +=== 2.2.7 Use TCP protocol to uplink data === 211 + 212 +This feature is supported since firmware version v110 213 + 214 +* **AT+PRO=4 ** ~/~/ Set to use TCP protocol to uplink 215 +* **AT+SERVADDR=120.24.4.116,5600 ** ~/~/ to set TCP server address and port 216 + 217 +(% style="text-align:center" %) 218 +[[image:image-20220907153818-13.png||height="486" width="668"]] 219 + 220 +(% style="text-align:center" %) 221 +[[image:image-20220907153827-14.png||height="236" width="684"]] 222 + 223 +=== 2.2.8 Change Update Interval === 224 + 225 +User can use below command to change the **uplink interval**. 226 + 227 +* **AT+TDC=600 ** ~/~/ Set Update Interval to 600s 228 + 229 +**NOTE:** 230 + 231 +**~1. By default, the device will send an uplink message every 2 hour.** 232 + 233 +== 2.3 Uplink Payload == 234 + 235 +In this mode, uplink payload includes 87 bytes in total by default. 236 + 237 +Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 238 + 239 +(% style="width:934px" %) 240 +|(% style="width:93px" %)**Size(bytes)**|(% style="width:82px" %)**8**|(% style="width:43px" %)**2**|(% style="width:41px" %)**2**|(% style="width:126px" %)**1**|(% style="width:54px" %)**1**|(% style="width:84px" %)1|(% style="width:75px" %)2|(% style="width:133px" %)2|(% style="width:70px" %)2|(% style="width:127px" %)4 241 +|(% style="width:93px" %)**Value**|(% style="width:82px" %)Device ID|(% style="width:43px" %)Ver|(% style="width:41px" %)BAT|(% style="width:126px" %)Signal Strength|(% style="width:54px" %)MOD|(% style="width:84px" %)Interrupt|(% style="width:75px" %)Soil PH|(% style="width:133px" %)Soil Temperature|(% style="width:70px" %)Soil PH|(% style="width:127px" %)Time stamp ..... 242 + 243 +|**Size(bytes)**|**8**|**2**|**2**|1|1|1|2|2|4|2|2|4 244 +|**Value**|Device ID|Ver|BAT|Signal Strength|MOD|Interrupt|Soil PH|Soil Temperature|Time stamp|Soil Temperature|Soil PH|Time stamp ..... 245 + 246 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSPH01 uplink data. 247 + 248 +(% style="text-align:center" %) 249 +[[image:image-20220907153902-15.png||height="581" width="804"]] 250 + 251 + 252 +The payload is ASCII string, representative same HEX: 253 + 254 +0xf86841105675413800640c781701000225010b6315537b010b0226631550fb010e022663154d7701110225631549f1011502246315466b01190223631542e5011d022163153f62011e022163153bde011e022163153859 where: 255 + 256 +* Device ID: 0xf868411056754138 = f868411056754138 257 +* Version: 0x0064=100=1.0.0 258 + 259 +* BAT: 0x0c78 = 3192 mV = 3.192V 260 +* Singal: 0x17 = 23 261 +* Mod: 0x01 = 1 262 +* Interrupt: 0x00= 0 263 +* Soil PH: 0x0225= 549 = 5.49 264 +* Soil Temperature:0x010B =267=26.7 °C 265 +* Time stamp : 0x6315537b =1662342011 266 +* Soil Temperature,Soil PH,Time stamp : 010b0226631550fb 267 +* 8 sets of recorded data: Temperature,Soil PH,Time stamp : 010e022663154d77,....... 268 + 269 +== 2.4 Payload Explanation and Sensor Interface == 270 + 271 +=== 2.4.1 Device ID === 272 + 273 +By default, the Device ID equal to the last 15 bits of IMEI. 274 + 275 +User can use **AT+DEUI** to set Device ID 276 + 277 +**Example:** 278 + 279 +AT+DEUI=868411056754138 280 + 281 +The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID. 282 + 283 +=== 2.4.2 Version Info === 284 + 285 +Specify the software version: 0x64=100, means firmware version 1.00. 286 + 287 +For example: 0x00 64 : this device is NSPH01 with firmware version 1.0.0. 288 + 289 +=== 2.4.3 Battery Info === 290 + 291 +Check the battery voltage for NSPH01. 292 + 293 +Ex1: 0x0B45 = 2885mV 294 + 295 +Ex2: 0x0B49 = 2889mV 296 + 297 +=== 2.4.4 Signal Strength === 298 + 299 +NB-IoT Network signal Strength. 300 + 301 +**Ex1: 0x1d = 29** 302 + 303 +**0** -113dBm or less 304 + 305 +**1** -111dBm 306 + 307 +**2...30** -109dBm... -53dBm 308 + 309 +**31** -51dBm or greater 310 + 311 +**99** Not known or not detectable 312 + 313 +=== 2.4.5 Soil PH === 314 + 315 +Get the PH content of the soil. The value range of the register is 300-1000(Decimal), divide this value by 100 to get the percentage of PH in the soil. 316 + 317 +For example, if the data you get from the register is **__0x05 0xDC__**, the PH content in the soil is 318 + 319 +**0229(H) = 549(D) /100 = 5.49.** 320 + 321 +=== 2.4.6 Soil Temperature === 322 + 323 +Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is **__0x09 0xEC__**, the temperature content in the soil is 324 + 325 +**Example**: 326 + 327 +If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/10 = 26.1 °C 328 + 329 +If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/10 = -12.9 °C 330 + 331 +=== 2.4.7 Timestamp === 332 + 333 +Time stamp : 0x6315537b =1662342011 334 + 335 +Convert Unix timestamp to time 2022-9-5 9:40:11. 336 + 337 +=== 2.4.8 Digital Interrupt === 338 + 339 +Digital Interrupt refers to pin **GPIO_EXTI**, and there are different trigger methods. When there is a trigger, the NSPH01 will send a packet to the server. 340 + 341 +The command is: 342 + 343 +**AT+INTMOD=3 ** ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.** 344 + 345 +The lower four bits of this data field shows if this packet is generated by interrupt or not. Click here for the hardware and software set up. 346 + 347 +Example: 348 + 349 +0x(00): Normal uplink packet. 350 + 351 +0x(01): Interrupt Uplink Packet. 352 + 353 +=== 2.4.9 +5V Output === 354 + 355 +NSPH01 will enable +5V output before all sampling and disable the +5v after all sampling. 356 + 357 +The 5V output time can be controlled by AT Command. 358 + 359 +**AT+5VT=1000** 360 + 361 +Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.** ** 362 + 363 + 364 +== 2.5 Downlink Payload == 365 + 366 +By default, NSPH01 prints the downlink payload to console port. 367 + 368 +(% style="text-align:center" %) 369 +[[image:image-20220907154636-17.png]] 370 + 371 + 372 + 373 + 374 + 375 + 376 + 377 +**Examples:** 378 + 379 +* **Set TDC** 380 + 381 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 382 + 383 +Payload: 01 00 00 1E TDC=30S 384 + 385 +Payload: 01 00 00 3C TDC=60S 386 + 387 +* **Reset** 388 + 389 +If payload = 0x04FF, it will reset the NSPH01 390 + 391 +* **INTMOD** 392 + 393 +Downlink Payload: 06000003, Set AT+INTMOD=3 394 + 395 +== 2.6 LED Indicator == 396 + 397 +The NSPH01 has an internal LED which is to show the status of different state. 398 + 399 +* When power on, NSPH01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe) 400 +* Then the LED will be on for 1 second means device is boot normally. 401 +* After NSPH01 join NB-IoT network. The LED will be ON for 3 seconds. 402 +* For each uplink probe, LED will be on for 500ms. 403 + 404 +== 2.7 Installation and Maintain == 405 + 406 +=== 2.7.1 Before measurement === 407 + 408 +If the NSPH01 has more than 7 days not use or just clean the pH probe. User should put the probe inside pure water for more than 24 hours for activation. If no put in water, user need to put inside soil for more than 24 hours to ensure the measurement accuracy. 409 + 410 +=== 2.7.2 Measurement === 411 + 412 +**Measurement the soil surface:** 413 + 414 +[[image:image-20220907154700-18.png]] 415 + 416 +Choose the proper measuring position. Split the surface soil according to the measured deep. 417 + 418 +Put pure water, or rainwater to make the soil of measurement point to moist mud. Remove rocks or hard things. 419 + 420 +Slowly insert the probe to the measure point. Don't use large force which will break the probe. Make sure not shake when inserting. 421 + 422 +Put soil over the probe after insert. And start to measure. 423 + 424 +**Measurement inside soil:** 425 + 426 +Dig a hole with diameter > 20CM. 427 + 428 +Insert the probe inside, method like measure the surface. 429 + 430 +=== 2.7.3 Maintain Probe === 431 + 432 +1. pH probe electrode is fragile and no strong. User must avoid strong force or hitting it. 433 +1. After long time use (3~~ 6 months). The probe electrode needs to be clean; user can use high grade sandpaper to polish it or put in 5% hydrochloric acid for several minutes. After the metal probe looks like new, user can use pure water to wash it. 434 +1. Probe reference electrode is also no strong, need to avoid strong force or hitting. 435 +1. User should keep reference electrode wet while not use. 436 +1. Avoid the probes to touch oily matter. Which will cause issue in accuracy. 437 +1. The probe is IP68 can be put in water. 438 + 439 +== 2.8 PH and Temperature alarm function == 440 + 441 +➢ AT Command: 442 + 443 +AT+ PHALARM=min,max 444 + 445 +² When min=3, and max≠0, Alarm higher than max 446 + 447 +² When min≠0, and max=0, Alarm lower than min 448 + 449 +² When min≠0 and max≠0, Alarm higher than max or lower than min 450 + 451 +Example: 452 + 453 +AT+ PHALARM =5,8 ~/~/ Alarm when PH lower than 5. 454 + 455 +AT+ TEMPALARM=min,max 456 + 457 +² When min=0, and max≠0, Alarm higher than max 458 + 459 +² When min≠0, and max=0, Alarm lower than min 460 + 461 +² When min≠0 and max≠0, Alarm higher than max or lower than min 462 + 463 +Example: 464 + 465 +AT+ TEMPALARM=20,30 ~/~/ Alarm when temperature lower than 20. 466 + 467 + 468 +== 2.9 Set the number of data to be uploaded and the recording time == 469 + 470 +➢ AT Command: 471 + 472 +AT+TR=900 ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 473 + 474 + 475 +AT+NOUD=8 ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 476 + 477 +== 2.10 Read or Clear cached data == 478 + 479 +➢ AT Command: 480 + 481 +AT+CDP ~/~/ Read cached data 482 + 483 +[[image:image-20220907154700-19.png]] 484 + 485 + 486 +AT+CDP=0 ~/~/ Clear cached data 487 + 488 + 489 +== 2.11 Calibration == 490 + 491 +User can do calibration for the probe. It is limited to use below pH buffer solution to calibrate: 4.00, 6.86, 9.18. When calibration, user need to clean the electrode and put the probe in the pH buffer solution to wait the value stable ( a new clean electrode might need max 24 hours to be stable). 492 + 493 +After stable, user can use below command to calibrate. 494 + 495 +[[image:image-20220907154700-20.png]] 496 + 497 +== 2.12 Firmware Change Log == 498 + 499 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0>>url:https://www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0]] 500 + 501 +Upgrade Instruction: [[Upgrade Firmware>>path:#H5.1200BHowtoUpgradeFirmware]] 502 + 503 +== 2.13 Battery Analysis == 504 + 505 +=== 2.13.1 Battery Type === 506 + 507 +The NSPH01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 508 + 509 +The battery is designed to last for several years depends on the actually use environment and update interval. 510 + 511 +The battery related documents as below: 512 + 513 +* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 514 +* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 515 +* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 516 + 517 +[[image:image-20220907154700-21.png]] 518 + 519 +=== 2.13.2 Power consumption Analyze === 520 + 521 +Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 522 + 523 +Instruction to use as below: 524 + 525 +**Step 1: **Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 526 + 527 +**Step 2: ** Open it and choose 528 + 529 +* Product Model 530 +* Uplink Interval 531 +* Working Mode 532 + 533 +And the Life expectation in difference case will be shown on the right. 534 + 535 +(% style="text-align:center" %) 536 +[[image:image-20220907154700-22.jpeg]] 537 + 538 + 539 + 540 +=== 2.13.3 Battery Note === 541 + 542 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 543 + 544 +=== 2.13.4 Replace the battery === 545 + 546 +The default battery pack of NSPH01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 547 + 548 += 3. Access NB-IoT Module = 549 + 550 +Users can directly access the AT command set of the NB-IoT module. 551 + 552 +The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 553 + 554 +(% style="text-align:center" %) 555 +[[image:image-20220907154700-23.png]] 556 + 557 + 558 + 559 += 4. Using the AT Commands = 560 + 561 +== 4.1 Access AT Commands == 562 + 563 +See this link for detail: [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 564 + 565 +AT+<CMD>? : Help on <CMD> 566 + 567 +AT+<CMD> : Run <CMD> 568 + 569 +AT+<CMD>=<value> : Set the value 570 + 571 +AT+<CMD>=? : Get the value 572 + 573 +**General Commands** 574 + 575 +AT : Attention 576 + 577 +AT? : Short Help 578 + 579 +ATZ : MCU Reset 580 + 581 +AT+TDC : Application Data Transmission Interval 582 + 583 +AT+CFG : Print all configurations 584 + 585 +AT+CFGMOD : Working mode selection 586 + 587 +AT+INTMOD : Set the trigger interrupt mode 588 + 589 +AT+5VT : Set extend the time of 5V power 590 + 591 +AT+PRO : Choose agreement 592 + 593 +AT+RXDL : Extend the sending and receiving time 594 + 595 +AT+SERVADDR : Server Address 596 + 597 +AT+TR : Get or Set record time" 598 + 599 + 600 +AT+NOUD : Get or Set the number of data to be uploaded 601 + 602 + 603 +AT+CDP : Read or Clear cached data 604 + 605 + 606 +AT+TEMPALARM : Get or Set alarm of temp 607 + 608 +AT+PHALARM : Get or Set alarm of PH 609 + 610 +AT+ PHCAL : calibrate PH value 611 + 612 + 613 +**COAP Management** 614 + 615 +AT+URI : Resource parameters 616 + 617 +**UDP Management** 618 + 619 +AT+CFM : Upload confirmation mode (only valid for UDP) 620 + 621 +**MQTT Management** 622 + 623 +AT+CLIENT : Get or Set MQTT client 624 + 625 +AT+UNAME : Get or Set MQTT Username 626 + 627 +AT+PWD : Get or Set MQTT password 628 + 629 +AT+PUBTOPIC : Get or Set MQTT publish topic 630 + 631 +AT+SUBTOPIC : Get or Set MQTT subscription topic 632 + 633 +**Information** 634 + 635 +AT+FDR : Factory Data Reset 636 + 637 +AT+PWORD : Serial Access Password 638 + 639 += 5. FAQ = 640 + 641 +== 5.1 How to Upgrade Firmware == 642 + 643 +User can upgrade the firmware for 1) bug fix, 2) new feature release. 644 + 645 +Please see this link for how to upgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]] 646 + 647 +**Notice, **NSPH01 **and **NSPH01 **share the same mother board. They use the same connection and method to update.** 648 + 649 +== 5.2 Can I calibrate NSPH01 to different soil types? == 650 + 651 +NSPH01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]]. 652 + 653 += 6. Trouble Shooting = 654 + 655 +== 6.1 Connection problem when uploading firmware == 656 + 657 +**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]] 658 + 659 +== 6.2 AT Command input doesn't work == 660 + 661 +In the case if user can see the console output but can't type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn't send **ENTER** while press the send key, user need to add ENTER in their string. 662 + 663 += 7. Order Info = 664 + 665 +Part Number**:** NSPH01 666 + 667 += 8. Packing Info = 668 + 669 +**Package Includes**: 670 + 671 +* NSPH01 NB-IoT Soil Moisture & EC Sensor x 1 672 +* External antenna x 1 673 + 674 +**Dimension and weight**: 675 + 676 +* Size: 195 x 125 x 55 mm 677 +* Weight: 420g 678 + 679 += 9. Support = 680 + 681 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 682 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 683 + 684 +
- image-20220907154700-20.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.David - Size
-
... ... @@ -1,0 +1,1 @@ 1 +24.8 KB - Content
- image-20220907154700-21.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.David - Size
-
... ... @@ -1,0 +1,1 @@ 1 +132.7 KB - Content
- image-20220907154700-22.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.David - Size
-
... ... @@ -1,0 +1,1 @@ 1 +102.7 KB - Content
- image-20220907154700-23.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.David - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.1 KB - Content