Changes for page NSE01 - NB-IoT Soil Moisture & EC Sensor User Manual
Last modified by Bei Jinggeng on 2024/03/30 17:42
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -933,7 +933,9 @@ 933 933 934 934 == 5.2 AT Command input doesn’t work == 935 935 936 +((( 936 936 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 938 +))) 937 937 938 938 939 939 == 5.3 Device rejoin in at the second uplink packet == ... ... @@ -945,7 +945,9 @@ 945 945 946 946 (% style="color:#4f81bd" %)**Cause for this issue:** 947 947 950 +((( 948 948 The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin. 952 +))) 949 949 950 950 951 951 (% style="color:#4f81bd" %)**Solution: ** ... ... @@ -952,7 +952,7 @@ 952 952 953 953 All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below: 954 954 955 -[[image:1654500929571-736.png]] 959 +[[image:1654500929571-736.png||height="458" width="832"]] 956 956 957 957 958 958 = 6. Order Info =