Changes for page NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 17:03
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.David - Content
-
... ... @@ -79,7 +79,6 @@ 79 79 * 8500mAh Battery for long-term use 80 80 81 81 82 - 83 83 == 1.3 Radar probe specification == 84 84 85 85 ... ... @@ -93,7 +93,6 @@ 93 93 * Vertical Angel: 23° 94 94 95 95 96 - 97 97 == 1.4 Storage Temperature == 98 98 99 99 ... ... @@ -114,7 +114,6 @@ 114 114 * Bottom water level monitoring 115 115 116 116 117 - 118 118 == 1.6 Specification == 119 119 120 120 ... ... @@ -133,7 +133,6 @@ 133 133 * B28 @H-FDD: 700MHz 134 134 135 135 136 - 137 137 == 1.7 Installation == 138 138 139 139 ... ... @@ -346,8 +346,10 @@ 346 346 [[image:1670406261143-723.png]] 347 347 348 348 349 -The payload is ASCII string, representative same HEX: **0x (% style="color:red" %)__f867787050471071__(% style="color:blue" %)__0064__(% style="color:green" %) __0cc3__(%style="color:#00b0f0" %) 0__9__(%style="color:#7030a0" %) __01__(%style="color:#0020b0"%) __00__(% style="color:#420042" %)__00ef__(%style="color:#660066" %) (% style="color:#663300" %)__013d__(% style="color:#d60093" %)__6390453d__(%%)**345 +The payload is ASCII string, representative same HEX: f867787050471071 0064 0cc3 09 01 00 00ef 013d 6390453d 350 350 347 +**0x (% style="color:red" %)__f867787050471071__ (% style="color:blue" %)__0064__ (% style="color:green" %) __0cc3__(% style="color:#00b0f0" %) 0__9__(% style="color:#7030a0" %) __01__(% style="color:#0020b0" %) __00__ (% style="color:#420042" %)__00ef__(% style="color:#660066" %) (% style="color:#663300" %)__013d__ (% style="color:#d60093" %)__6390453d__(%%)** 348 + 351 351 **where:** 352 352 353 353 * (% style="color:#037691" %)**Device ID:**(%%) 0x f867787050471071 = f867787050471071 ... ... @@ -368,6 +368,7 @@ 368 368 369 369 * (% style="color:#037691" %)**Timestamp: **(%%)0x6390453d =1670399293 (Unix Time) 370 370 369 + 371 371 == 2.4 Payload Explanation and Sensor Interface == 372 372 373 373 === 2.4.1 Device ID === ... ... @@ -389,7 +389,7 @@ 389 389 390 390 Specify the software version: 0x64=100, which means firmware version 1.00. 391 391 392 -For example 0x00 64 : This device is NMDS200 with firmware version 1.0.0. 391 +For example 0x00 64 : This device is NMDS200 1 with firmware version 1.0.0. 393 393 394 394 395 395 === 2.4.3 Battery Info === ... ... @@ -482,6 +482,7 @@ 482 482 * After NMDS200 join NB-IoT network. The LED will be ON for 3 seconds. 483 483 * For each uplink probe, LED will be on for 500ms. 484 484 484 + 485 485 == 2.7 Distance alarm function == 486 486 487 487 ... ... @@ -524,19 +524,65 @@ 524 524 == 2.10 Firmware Change Log == 525 525 526 526 527 -Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/8 elvp2qi9bcv47a/AAAKp0E2nUffztF0tYhqPoE1a?dl=0>>https://www.dropbox.com/sh/8elvp2qi9bcv47a/AAAKp0E2nUffztF0tYhqPoE1a?dl=0]]527 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0>>https://www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0]] 528 528 529 529 Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 530 530 531 531 532 -== 2.11 & Power Consumption==532 +== 2.11 Battery Analysis == 533 533 534 +=== 2.11.1 Battery Type === 534 534 535 -NMDS200 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 536 536 537 - [[**BatteryInfo&Power ConsumptionAnalyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]].537 +The NMDS200 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 538 538 539 +The battery is designed to last for several years depends on the actual use environment and update interval. 539 539 541 +The battery-related documents as below: 542 + 543 +* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 544 + 545 +* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 546 + 547 +* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 548 + 549 +[[image:image-20221021111911-26.png]] 550 + 551 + 552 +=== 2.11.2 Power consumption Analyze === 553 + 554 + 555 +Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 556 + 557 +Instruction to use as below: 558 + 559 +(% style="color:blue" %)**Step 1: **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 560 + 561 +(% style="color:blue" %)**Step 2: **(%%) Open it and choose 562 + 563 +* Product Model 564 + 565 +* Uplink Interval 566 + 567 +* Working Mode 568 + 569 +And the Life expectation in difference case will be shown on the right. 570 + 571 +[[image:1666596205057-567.png]] 572 + 573 + 574 +=== 2.11.3 Battery Note === 575 + 576 + 577 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 578 + 579 + 580 +=== 2.11.4 Replace the battery === 581 + 582 + 583 +The default battery pack of NMDS200 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 584 + 585 + 540 540 = 3. Access NB-IoT Module = 541 541 542 542 ... ... @@ -661,12 +661,6 @@ 661 661 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string. 662 662 663 663 664 -== 6.3 Not able to connect to NB-IoT network and keep showing "Signal Strength:99". == 665 - 666 - 667 -This means sensor is trying to join the NB-IoT network but fail. Please see this link for **//[[trouble shooting for signal strenght:99>>doc:Main.CSQ\:99,99.WebHome]]//**. 668 - 669 - 670 670 = 7. Order Info = 671 671 672 672 ... ... @@ -681,7 +681,6 @@ 681 681 * NMDS200 NB-IoT Microwave Radar Distance Sensor x 1 682 682 683 683 684 - 685 685 = 9. Support = 686 686 687 687
- image-20221212171610-1.jpeg
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -756.0 KB - Content