<
From version < 83.6 >
edited by Xiaoling
on 2022/12/08 11:16
To version < 37.1 >
edited by Edwin Chen
on 2022/10/22 23:46
>
Change comment: Uploaded new attachment "image-20221022234602-2.png", version {1}

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
1 +CPN01- NB-IoT Outdoor Open/Close Dry Contact Sensor User Manual
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.Edwin
Content
... ... @@ -1,45 +1,34 @@
1 1  (% style="text-align:center" %)
2 -[[image:LMDS200_10.jpg]]
2 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652856952171-363.png?rev=1.1||alt="1652856952171-363.png" height="578" width="588"]]
3 3  
4 -
5 -**Table of Contents:**
6 -
7 7  {{toc/}}
8 8  
6 += **1. Introduction** =
9 9  
8 +== **1.1 ​**What is CPN01 **NB-IoT** Pulse/Contact Sensor ==
10 10  
10 +The Dragino CPN01 is an (% style="color:blue" %)**NB-IoT Dry Contact Sensor**(%%). It detects open/close status and uplinks the info to IoT server via Nb-IoT network. User can see the (% style="color:blue" %)dry contact status, open time, and open counts(%%) in the IoT Server.
11 11  
12 -= 1.  Introduction =
12 +The CPN01 will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculates the last open duration. Users can also disable the uplink for each open/close event, instead, device can count each open event and uplink periodically.
13 13  
14 -== 1.1 ​ What is NMDS200 NB-IoT Microwave Radar Distance Sensor ==
14 +CPN01 has (% style="color:blue" %)Open-Alarm feature(%%), user can set this feature so CPN01 will send an alarm if the contact has been open exceeds a certain time.
15 15  
16 +CPN01 is designed for outdoor use. It has a weatherproof enclosure and industrial-level battery to work in low to high temperatures.
16 16  
17 -(((
18 -The Dragino NMDS200 is a(% style="color:blue" %)** NB-IoT Microwave Radar distance sensor**(%%). It uses (% style="color:blue" %)**24Ghz Microwave**(%%) to detect the distance between sensor and different objects. Compare vs ultrasonic or Lidar measurement method, Microwave Radar is (% style="color:blue" %)**more reliable for condensation / dusty environment**(%%). It can sense correct distance even there is water or thick dust on top of the sensor.
18 +NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity, and spectrum efficiency, especially in deep coverage.
19 +\\CPN01 supports different uplink methods including (% style="color:blue" %)**TCP, MQTT, UDP, and CoAP**(%%) for different application requirements.
20 +\\CPN01 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long-term use of up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method)
21 +\\To use CPN01, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that CPN01 supports. If local operator support it, user needs to get a (% style="color:blue" %)**NB-IoT SIM card**(%%) from the operator and install into CPN01 to get NB-IoT network connection.
19 19  
20 -The NMDS200 can be applied to scenarios such as horizontal distance measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, etc.
23 +
21 21  
22 -NMDS200 can (% style="color:blue" %)**measure two distances**(%%): the closest object and next object behind the closest one.
25 +== **​1.2 Features** ==
23 23  
24 -NMDS200 (% style="color:blue" %)**supports Alarm Feature**(%%), user can set the NMDS200 to uplink data in a short interval when the distance is out of configured range.
25 -
26 -NarrowBand-Internet of Things (NB-IoT) is a (% style="color:blue" %)**standards-based low power wide area (LPWA) technology**(%%) developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity, and spectrum efficiency, especially in deep coverage.
27 -
28 -NMDS200 (% style="color:blue" %)**supports different uplink**(%%) methods including (% style="color:blue" %)**TCP, MQTT, UDP, and CoAP**(%%) for different application requirements.
29 -
30 -NMDS200 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**,(%%) It is designed for long-term use of up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method)
31 -
32 -To use NMDS200, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that NMDS200 supports. If local operator support it, user needs to get a** (% style="color:blue" %)NB-IoT SIM card(%%)** from the operator and install into NMDS200 to get NB-IoT network connection.
33 -)))
34 -
35 -
36 -== ​1.2  Features ==
37 -
38 -
39 39  * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD
40 -* Short uplink interval for Distance Alarm
28 +* Open/Close detect
29 +* Open/Close statistics
41 41  * Monitor Battery Level
42 -* Microwave Radar for distance detection
31 +* Uplink on periodically and open/close event
43 43  * Datalog feature
44 44  * Uplink periodically
45 45  * Downlink to change configure
... ... @@ -50,523 +50,527 @@
50 50  * Micro SIM card slot for NB-IoT SIM
51 51  * 8500mAh Battery for long-term use
52 52  
53 -== 1.3 Radar probe specification ==
42 +== **1.3  Specification** ==
54 54  
44 +**Common DC Characteristics:**
55 55  
56 -* Measuring Method: FMCW
57 -* Frequency: 24.000 24.500 GHz
58 -* Measurement output power: 6dBm
59 -* Measure range: 0.5 20m
60 -* Accuracy: ±0.1m
61 -* Resolution: 0.01m
62 -* Horizontal Angel: 78°
63 -* Vertical Angel: 23°
46 +* Supply Voltage: 2.1v ~~ 3.6v
47 +* Operating Temperature: -40 ~~ 85°C
64 64  
65 -== 1.4  Storage Temperature ==
49 +**NB-IoT Spec:**
66 66  
51 +* - B1 @H-FDD: 2100MHz
52 +* - B3 @H-FDD: 1800MHz
53 +* - B8 @H-FDD: 900MHz
54 +* - B5 @H-FDD: 850MHz
55 +* - B20 @H-FDD: 800MHz
56 +* - B28 @H-FDD: 700MHz
67 67  
68 - -40°C to +85°C
58 +== **1.4 Installation** ==
69 69  
60 +Connect CPL01 to an Open Close sensor like below. So it can detect the open/close event.
70 70  
71 -== 1.5 ​ Applications ==
62 +[[image:image-20221021110329-1.png]]
72 72  
64 +[[image:image-20221021110340-2.png]]
73 73  
74 -* Horizontal distance measurement
75 -* Liquid level measurement
76 -* Parking management system
77 -* Object proximity and presence detection
78 -* Intelligent trash can management system
79 -* Robot obstacle avoidance
80 -* Automatic control
81 -* Sewer
82 -* Bottom water level monitoring
66 +== **1.5 ​Applications** ==
83 83  
84 -== 1.6  Specification ==
68 +* Open/Close Detection
69 +* Pulse meter application
70 +* Dry Contact Detection
85 85  
72 +== **1.6 Mechanical** ==
86 86  
87 -(% style="color:blue" %)**Common DC Characteristics:**
74 +​[[image:image-20221021110415-3.png]]
88 88  
89 -* Supply Voltage: 2.1v ~~ 3.6v
90 -* Operating Temperature: 0 ~~ 70°C
76 +== ** 1.7 Pin Definitions and Switch** ==
91 91  
92 -(% style="color:blue" %)**NB-IoT Spec:**
78 +[[image:image-20221021110429-4.png]]
93 93  
94 -* B1 @H-FDD: 2100MHz
95 -* B3 @H-FDD: 1800MHz
96 -* B8 @H-FDD: 900MHz
97 -* B5 @H-FDD: 850MHz
98 -* B20 @H-FDD: 800MHz
99 -* B28 @H-FDD: 700MHz
80 +=== **1.7.1 Pin Definition** ===
100 100  
101 -== 1. Installation ==
82 +CPL01 is pre-configured to connect to two external wires. The other pins are not used. If user wants to know more about other pins, please refer to the user manual of LSN50v2 at: [[https:~~/~~/www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0>>url:https://www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0]]
102 102  
84 +=== **1.7.2 Jumper JP2(Power ON/OFF)** ===
103 103  
104 -Sensor measure direction and angle is as below. When install the sensor, please make sure the sensor direct to object.
105 105  
87 +Power on Device when putting this jumper.
106 106  
107 -[[image:image-20221207170748-1.png]] [[image:image-20221207170748-2.png||height="366" width="672"]]
108 108  
109 109  
91 +=== **1.7.3 BOOT MODE / SW1** ===
110 110  
111 -== 1.8  Pin Definitions and Switch ==
112 112  
94 +1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run.
113 113  
114 -[[image:1670404362039-351.png]]
96 +2) Flash: work mode, the device starts to work and send out console output for further debug
115 115  
116 116  
117 -= 2.  Use NMDS200 to communicate with IoT Server =
118 118  
119 -== 2.1  How it works ==
100 +=== **1.7.4 Reset Button** ===
120 120  
121 121  
122 -The NB-IoT network will forward this value to IoT server via the protocol defined by NMDS200.
103 +Press to reboot the device.
123 123  
124 -The diagram below shows the working flow in the default firmware of NMDS200:
105 +== ==
125 125  
126 -[[image:image-20221021110615-5.png]]
107 +=== **1.7.5 LED** ===
127 127  
128 128  
129 -== 2.2 ​ Configure NMDS200 ==
110 +It will flash:
130 130  
112 +1. Boot the device in flash mode
113 +1. Send an uplink packet
131 131  
132 -To use NMDS200 in your city, make sure to meet below requirements:
115 += **2.  Use CPN01 to communicate with IoT Server** =
133 133  
134 -* Your local operator has already distributed an NB-IoT Network.
135 -* The local NB-IoT network used the band that NMDS200 supports.
136 -* Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
117 +== **2.1  How it works** ==
137 137  
138 -Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The NMDS200 will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server.
119 +The CPN01 is equipped with a NB-IoT module, the pre-loaded firmware in CPN01 will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by CPN01.
139 139  
140 -[[image:image-20221208090742-1.png]]
121 +The diagram below shows the working flow in default firmware of CPN01:
141 141  
123 +[[image:image-20221021110615-5.png]]
142 142  
143 -=== 2.2.1 Insert NB-IoT SIM card ===
125 +== **2.2 Configure the CPN01** ==
144 144  
127 +=== **2.2.1 Test Requirement** ===
145 145  
146 -Insert the NB-IoT Card get from your provider.
129 +To use CPN01 in your city, make sure meet below requirements:
147 147  
148 -User needs to take out the NB-IoT module and insert the SIM card like below:
131 +* Your local operator has already distributed a NB-IoT Network there.
132 +* The local NB-IoT network used the band that CPN01 supports.
133 +* Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
149 149  
150 -[[image:image-20221021110745-6.png]]
135 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The CPN01 will use CoAP(120.24.4.116:5683) or raw UDP(120.24.4.116:5601) or MQTT(120.24.4.116:1883)or TCP(120.24.4.116:5600)protocol to send data to the test server
151 151  
137 + ​
152 152  
153 -=== 2.2.2 Connect USB – TTL to NMDS200 and configure it ===
139 +=== **2.2.2 Insert SIM card** ===
154 154  
141 +Insert the NB-IoT Card get from your provider.
155 155  
156 -User need to configure NMDS200 via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NMDS200 support AT Commands, user can use a USB to TTL adapter to connect to NMDS200 and use AT Commands to configure it, as below.
143 +User need to take out the NB-IoT module and insert the SIM card like below:
157 157  
158 -(% style="color:blue" %)**Connection:**
145 +[[image:image-20221021110745-6.png]] ​
159 159  
160 -(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
147 +=== **2.2.3 Connect USB TTL to CPN01 to configure it** ===
161 161  
162 -(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD**
149 +User need to configure CPN01 via serial port to set the **Server Address** / **Uplink Topic** to define where and how-to uplink packets. CPN01 support AT Commands, user can use a USB to TTL adapter to connect to CPN01 and use AT Commands to configure it, as below.
163 163  
164 -(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD**
151 +**Connection:**
165 165  
153 + USB TTL GND <~-~-~-~-> GND
166 166  
167 -In the PC, use below serial tool settings:
155 + USB TTL TXD <~-~-~-~-> UART_RXD
168 168  
169 -* Baud:  (% style="color:red" %)**9600**
157 + USB TTL RXD <~-~-~-~-> UART_TXD
170 170  
171 -* Data bits:** (% style="color:red" %)8(%%)**
159 +In the PC, use below serial tool settings:
172 172  
173 -* Stop bits: (% style="color:red" %)**1**
161 +* Baud:  **9600**
162 +* Data bits:** 8**
163 +* Stop bits: **1**
164 +* Parity:  **None**
165 +* Flow Control: **None**
174 174  
175 -* Parity (% style="color:red" %)**None**
167 +Make sure the switch is in FLASH position, then power on device by connecting the jumper on CPN01. CPN01 will output system info once power on as below, we can enter the **password: 12345678** to access AT Command input.
176 176  
177 -* Flow Control: (% style="color:red" %)**None**
178 -
179 -Make sure the switch is in FLASH position, then power on NMDS200 by connecting the (% style="color:orange" %)**Yellow Jumper**(%%).
180 -
181 181  ​[[image:image-20221021110817-7.png]]
182 182  
183 -NMDS200 will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input.
171 +**Note: the valid AT Commands can be found at **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
184 184  
173 +=== **2.2.4 Use CoAP protocol to uplink data** ===
185 185  
186 -(% style="color:red" %)**Note: the valid AT Commands can be found at:  **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
175 +**Note: if you don't have CoAP server, you can refer this link to set up one: **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
187 187  
177 +**Use below commands:**
188 188  
179 +* **AT+PRO=1**   ~/~/ Set to use CoAP protocol to uplink
180 +* **AT+SERVADDR=120.24.4.116,5683   ** ~/~/ to set CoAP server address and port
181 +* **AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** ~/~/Set COAP resource path
189 189  
190 -=== 2.2.3 Use CoAP protocol to uplink data ===
191 -
192 -
193 -(% style="color:red" %)**Note: if you don't have a CoAP server, you can refer this link to set up a CoAP server: **(%%)[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
194 -
195 -
196 -(% style="color:blue" %)**Use below commands in NMDS200:**
197 -
198 -* (% style="color:#037691" %)**AT+PRO=1**                (%%) ~/~/ Set to use CoAP protocol to uplink
199 -
200 -* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5683   ** (%%) ~/~/ Set CoAP server address and port
201 -
202 -* (% style="color:#037691" %)**AT+URI=0,0,11,2,"mqtt" ** (%%) ~/~/  Set CoAP resource path
203 -
204 204  For parameter description, please refer to AT command set
205 205  
206 206  [[image:image-20221021110948-8.png]]
207 207  
187 +After configure the server address and **reset the device** (via AT+ATZ ), CPN01 will start to uplink sensor values to CoAP server.
208 208  
209 -After configuring the server address and (% style="color:green" %)**reset NMDS200**(%%) (via AT+ATZ ), NMDS200 will start to uplink sensor values to the CoAP server.
189 +[[image:image-20221021110956-9.png]]
210 210  
211 -[[image:1670405841875-916.png]]
191 +=== **2.2.5 Use UDP protocol to uplink data(Default protocol)** ===
212 212  
193 +This feature is supported since firmware version v1.0.1
213 213  
214 -=== 2.2.4 Use UDP protocol to uplink data(Default protocol) ===
195 +* **AT+PRO=2   ** ~/~/ Set to use UDP protocol to uplink
196 +* **AT+SERVADDR=120.24.4.116,5601   ** ~/~/ to set UDP server address and port
197 +* **AT+CFM=1       ** ~/~/If the server does not respond, this command is unnecessary
215 215  
216 -
217 -(% style="color:blue" %)**AT Commands:**
218 -
219 -* (% style="color:#037691" %)**AT+PRO=2   ** (%%) ~/~/  Set to use UDP protocol to uplink
220 -
221 -* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/  Set UDP server address and port
222 -
223 -* (% style="color:#037691" %)**AT+CFM=1       ** (%%) ~/~/  If the server does not respond, this command is unnecessary
224 -
225 225  ​ [[image:image-20221021111025-10.png]]
226 226  
227 -
228 228  [[image:image-20221021111033-11.png||height="241" width="576"]]
229 229  
230 230  ​
231 231  
232 -=== 2.2.5 Use MQTT protocol to uplink data ===
205 +=== **2.2.6 Use MQTT protocol to uplink data** ===
233 233  
207 +This feature is supported since firmware version v110
234 234  
235 -(% style="color:blue" %)**AT Commands:**
209 +* **AT+PRO=3   ** ~/~/Set to use MQTT protocol to uplink
210 +* **AT+SERVADDR=120.24.4.116,1883   ** ~/~/Set MQTT server address and port
211 +* **AT+CLIENT=CLIENT       ** ~/~/Set up the CLIENT of MQTT
212 +* **AT+UNAME=UNAME                               **~/~/Set the username of MQTT
213 +* **AT+PWD=PWD                                        **~/~/Set the password of MQTT
214 +* **AT+PUBTOPIC=NSE01_PUB                    **~/~/Set the sending topic of MQTT
215 +* **AT+SUBTOPIC=NSE01_SUB          ** ~/~/Set the subscription topic of MQTT
236 236  
237 -* (% style="color:#037691" %)**AT+PRO=3   ** (%%) ~/~/  Set to use MQTT protocol to uplink
217 + [[image:image-20221021111058-12.png]]
238 238  
239 -* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,1883   ** (%%) ~/~/  Set MQTT server address and port
219 +[[image:image-20221021111108-13.png]]
240 240  
241 -* (% style="color:#037691" %)**AT+CLIENT=CLIENT       ** (%%) ~/~/  Set up the CLIENT of MQTT
221 +
242 242  
243 -* (% style="color:#037691" %)**AT+UNAME=UNAME                     **(%%)** **~/~/  Set the username of MQTT
223 +MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
244 244  
245 -* (% style="color:#037691" %)**AT+PWD=PWD                         **(%%)** **~/~/  Set the password of MQTT
225 +=== **2.2.7 Use TCP protocol to uplink data** ===
246 246  
247 -* (% style="color:#037691" %)**AT+PUBTOPIC=NSE01_PUB              **(%%)** **~/~/  Set the sending topic of MQTT
227 +This feature is supported since firmware version v110
248 248  
249 -* (% style="color:#037691" %)**AT+SUBTOPIC=NSE01_SUB          ** (%%) ~/~/  Set the subscription topic of MQTT
229 +* **AT+PRO=4   ** ~/~/ Set to use TCP protocol to uplink
230 +* **AT+SERVADDR=120.24.4.116,5600   ** ~/~/ to set TCP server address and port
250 250  
251 -​ [[image:image-20221118103445-7.png]]
232 +​ [[image:image-20221021111125-14.png]]
252 252  
234 +[[image:image-20221021111131-15.png]]
253 253  
254 -[[image:1670405928926-116.png]]
255 -
256 256  ​
257 257  
258 -MQTT protocol has a much higher power consumption compare with UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
238 +=== **2.2.8 Change Update Interval** ===
259 259  
240 +User can use below command to change the **uplink interval**.
260 260  
261 -=== 2.2.6 Use TCP protocol to uplink data ===
242 +* **AT+TDC=600      ** ~/~/ Set Update Interval to 600s
262 262  
244 +**NOTE:**
263 263  
264 -(% style="color:blue" %)**AT Commands:**
246 +**~1. By default, the device will send an uplink message every 1 hour.**
265 265  
266 -* (% style="color:#037691" %)**AT+PRO=4   ** (%%) ~/~/  Set to use TCP protocol to uplink
248 +== **2.3  Uplink Payload** ==
267 267  
268 -* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5600   ** (%%) ~/~/  Set TCP server address and port
250 +In this mode, uplink payload includes 87 bytes in total by default.
269 269  
270 - [[image:1670406036256-101.png||height="676" width="713"]]
252 +Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded.
271 271  
254 +|**Size(bytes)**|**8**|**2**|**2**|**1**|**1**|**1**|**2**|**2**|4
255 +|**Value**|[[Device ID>>path:#H2.4.1A0A0DeviceID]]|[[Ver>>path:#H2.4.2A0VersionInfo]]|[[BAT>>path:#H2.4.3A0BatteryInfo]]|[[Signal Strength>>path:#H2.4.4A0SignalStrength]]|MOD|[[Interrupt>>path:#H2.4.8A0DigitalInterrupt]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|Time stamp
272 272  
273 -[[image:image-20221021111131-15.png]]
257 +|2|2|4|8 group
258 +|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|Time stamp|...
274 274  
275 -
260 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the CPN01 uplink data.
276 276  
277 -=== 2.2.7 Change Update Interval ===
262 +[[image:image-20221021111201-16.png||height="572" width="792"]]
278 278  
264 +The payload is ASCII string, representative same HEX:
279 279  
280 -User can use below command to change the (% style="color:blue" %)**uplink interval**.
266 +**0x (% style="color:red" %)__0xf867787050213317__  (% style="color:blue" %)__0064__ (% style="color:green" %)_0c78__  __(% style="color:#00b0f0" %)17__  __(% style="color:#7030a0" %)01__  __(% style="color:#d60093" %)00__  __(% style="color:#a14d07" %)01 __ __(% style="color:#0020b0" %)__ __00__  __(% style="color:#420042" %)000009__  __(% style="color:#663300" %) 000002__  __(% style="color:#d60093" %)6315537bb__  __(% style="color:#663300" %)// 0100000b02000002663510fed__  __0100000e0200000263510f39 010000000000000063510e85 010000000000000063510d2e 010000000000000063510c7a 010000000000000063510bc6 010000000000000063510954 010000000000000063510882 //(%%)**
281 281  
282 -* (% style="color:#037691" %)**AT+TDC=7200      ** (%%) ~/~/ Set Update Interval to 7200s (4 hours)
268 +where:
269 +*(% style="color:#037691" %) **Device ID:**(%%) 0x f867787050213317 = f867787050213317
283 283  
284 -(% style="color:red" %)**NOTE:**
271 +*(% style="color:#037691" %) **Version:**(%%) 0x0064=100=1.0.0
285 285  
286 -1.  By default, the device will send an uplink message every 4 hour.
273 +*(% style="color:#037691" %) **BAT:**(%%) 0x0c78 = 3192 mV = 3.192V
287 287  
275 +*(% style="color:#037691" %) **Singal: **(%%)0x17 = 23
288 288  
289 -== 2.3  Uplink Payload ==
277 +*(% style="color:#037691" %) **Mod:**(%%) 0x01 = 1
290 290  
279 +*(% style="color:#037691" %) **Calculate Flag:**(%%) 0x00= 0
291 291  
292 -The uplink payload includes 23 bytes in total by default.
281 +*(% style="color:#037691" %) **Contact Status:**(%%) 0x00= 0
293 293  
294 -Each time the device uploads a data package. The user can use the AT+NOUD command to upload the recorded data.Up to 32 sets of recorded data can be uploaded.
283 +*(% style="color:#037691" %) **Alarm:**(%%)0x00 =0
295 295  
285 +*(% style="color:#037691" %) **Total pulse:0x09 =0**
296 296  
297 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
298 -|=(% scope="row" style="width: 50px;" %)**Size(bytes)**|(% style="width:50px" %)**8**|(% style="width:20px" %)**2**|(% style="width:20px" %)**2**|(% style="width:65px" %)**1**|(% style="width:25px" %)**1**|(% style="width:50px" %)**1**|(% style="width:90px" %)**2**|(% style="width:100px" %)**2**
299 -|=(% style="width: 93px;" %)**Value**|(% style="width:67px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:45px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:54px" %)MOD|(% style="width:62px" %)Exit flag|(% style="width:94px" %) [[Distance 1>>||anchor="H2.4.5A0Distance"]] |(% style="width:93px" %) [[Distance  2>>||anchor="H2.4.5A0Distance"]]
287 +*(% style="color:#037691" %) **The last open duration:**(%%)0x02 =2
300 300  
301 -(% border="1.5" style="background-color:#ffffcc; color:green; width:450px" %)
302 -|(% style="width:50px" %)**4**|(% style="width:90px" %)**2**|(% style="width:90px" %)**2**|(% style="width:60px" %)**4**|(% style="width:50px" %)(((
303 -**1-32 group**
304 -)))
305 -|(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.6A0Timestamp"]]| Distance 1 | Distance  2|(% style="width:67px" %)Time stamp|(% style="width:74px" %)...
289 +*(% style="color:#037691" %)**Time stamp :**(%%) 0x6315537b =1662342011
306 306  
307 -If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NMDS200 uplink data.
291 +*(% style="color:#037691" %) **Contact Status, Total pulse, Calculate Flag, The last open duration ,Time stamp :**(%%) 0100000b0200002663510fed
308 308  
309 -[[image:1670406261143-723.png]]
293 +*(% style="color:#037691" %) **8 sets of recorded data: Contact Status, Total pulse, Calculate Flag, The last open duration ,Time stamp :**(%%) 0100000e0200002663510f39,.......
310 310  
295 +== **2.4  Payload Explanation and Sensor Interface** ==
311 311  
312 -The payload is ASCII string, representative same HEX: f867787050471071  0064  0cc3  09  01  00 00e 013d  6390453d
297 +=== **2.4.1  Device ID** ===
313 313  
314 -**0x (% style="color:red" %)__f867787050471071__  (% style="color:blue" %)__0064__ (% style="color:green" %) __0cc3__(% style="color:#00b0f0" %) 0__9__(% style="color:#7030a0" %) __01__(% style="color:#0020b0" %) __00__ (% style="color:#420042" %)__00ef__(% style="color:#660066" %) (% style="color:#663300" %)__013d__ (% style="color:#d60093" %)__6390453d__(%%)**
299 +By default, the Device ID equal to the last 15 bits of IMEI.
315 315  
316 -**where:**
301 +User can use **AT+DEUI** to set Device ID
317 317  
318 -* (% style="color:#037691" %)**Device ID:**(%%) 0x f867787050471071 = f867787050471071
303 +**Example:**
319 319  
320 -* (% style="color:#037691" %)**Version:**(%%)  0x0064=100=1.0.0
305 +AT+DEUI=868411056754138
321 321  
322 -* (% style="color:#037691" %)**BAT :**(%%)  0x0cc3 = 3267 mV = 3.267V
307 +The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID.
323 323  
324 -* (% style="color:#037691" %)**Singal: **(%%)0x09 = 9
309 +=== **2.4.2  Version Info** ===
325 325  
326 -* (% style="color:#037691" %)**Mod:**(%%)  0x01 = 1
311 +Specify the software version: 0x64=100, means firmware version 1.00.
327 327  
328 -* (% style="color:#037691" %)**Exit flag: **(%%)0x00 =0
313 +For example: 0x00 64 : this device is CPN01 with firmware version 1.0.0.
329 329  
330 -* (% style="color:#037691" %)**Distance 1: **(%%)0x00ef=239
315 +=== **2.4.3  Battery Info** ===
331 331  
332 -* (% style="color:#037691" %)**Distance 2: **(%%)0x013d =317
317 +Check the battery voltage for CPN01.
333 333  
334 -* (% style="color:#037691" %)**Timestamp: **(%%)0x6390453d =1670399293 (Unix Time)
319 +Ex1: 0x0B45 = 2885mV
335 335  
321 +Ex2: 0x0B49 = 2889mV
336 336  
337 -== 2.4  Payload Explanation and Sensor Interface ==
323 +=== **2.4.4  Signal Strength** ===
338 338  
339 -=== 2.4.1  Device ID ===
325 +NB-IoT Network signal Strength.
340 340  
327 +**Ex1: 0x1d = 29**
341 341  
342 -By default, the Device ID is equal to the last 15 bits of IMEI.
329 +**0**  -113dBm or less
343 343  
344 -User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID
331 +**1**  -111dBm
345 345  
346 -**Example:**
333 +**2...30** -109dBm... -53dBm
347 347  
348 -AT+DEUI=868411056754138
335 +**31**   -51dBm or greater
349 349  
350 -The Device ID is stored in a non-erase area, Upgrade the firmware or run AT+FDR won't erase the Device ID.
337 +**99**    Not known or not detectable
351 351  
339 +=== **2.4.5 Calculate Flag** ===
352 352  
353 -=== 2.4.2  Version Info ===
341 +The calculate flag is a user define field, IoT server can use this filed to handle different meter with different pulse factor. For example, if there are 100 water meters, meter 1 ~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse.
354 354  
343 +User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation.
355 355  
356 -Specify the software version: 0x64=100, which means firmware version 1.00.
345 +Default value: 0. 
357 357  
358 -For example 0x00 64 : This device is NMDS200 1 with firmware version 1.0.0.
347 +Range (6 bits): (b)000000 ~~ (b) 111111
359 359  
349 +=== **2.4.6  Alarm** ===
360 360  
361 -=== 2.4.3  Battery Info ===
351 +See [[Alarm Base on Timeout>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H3.5AlarmBaseonTimeout]]
362 362  
353 +=== **2.4.7 Contact Status** ===
363 363  
364 -Check the battery voltage for NMDS200.
355 +0: Open
365 365  
366 -Ex1: 0x0B45 = 2885mV
357 +1: Close
367 367  
368 -Ex2: 0x0B49 = 2889mV
359 +=== **2.4.8 Total pulse** ===
369 369  
361 +Total pulse/counting base on dry [[contact trigger event>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.2SensorConfiguration2CFPORT3D4]]
370 370  
371 -=== 2.4.4  Signal Strength ===
363 +Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215
372 372  
365 +=== **2.4.9 The last open duration** ===
373 373  
374 -NB-IoT Network signal Strength.
367 +Dry Contact last open duration.
375 375  
376 -(% style="color:blue" %)**Ex1: 0x1d = 29**
369 +Unit: min.
377 377  
378 -(% style="color:#037691" %)**0** (%%) -113dBm or less
371 +[[image:image-20221021111346-17.png||height="146" width="770"]]
379 379  
380 -(% style="color:#037691" %)**1**  (%%) -111dBm
381 381  
382 -(% style="color:#037691" %)**2...30** (%%) -109dBm... -53dBm
374 +=== **2.4.10  Timestamp** ===
383 383  
384 -(% style="color:#037691" %)**31** (%%) -51dBm or greater
376 +Time stamp : 0x6315537b =1662342011
385 385  
386 -(% style="color:#037691" %)**99** (%%) Not known or not detectable
378 +Convert Unix timestamp to time 2022-9-5 9:40:11.
387 387  
380 +**~ **
388 388  
389 -=== 2.4.5  Distance ===
382 +== **2.5  Downlink Payload** ==
390 390  
384 +By default, CPN01 prints the downlink payload to console port.
391 391  
392 -[[image:1670407401682-959.png]]
386 +[[image:image-20221021111414-18.png]]
393 393  
388 +**Examples:**
394 394  
395 -(% style="color:blue" %)**Object1 Distance:**
390 +* **Set TDC**
396 396  
397 -Distance between sensor probe to the first object. (unit: cm)
392 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
398 398  
399 -For example, if the data you get from the register is 0x02 0x05, the distance between the sensor and the measured object is
394 +Payload:    01 00 00 1E    TDC=30S
400 400  
401 -(% style="color:blue" %)**0205(H) = 517 (D) = 517 cm.**
396 +Payload:    01 00 00 3C    TDC=60S
402 402  
398 +* **Reset**
403 403  
404 -(% style="color:blue" %)**Object2 Distance:**
400 +If payload = 0x04FF, it will reset the NSE01
405 405  
406 -Distance between sensor probe to the second object. (unit: cm)
402 +* **INTMOD**
407 407  
404 +Downlink Payload: 06000003, Set AT+INTMOD=3
408 408  
409 -=== 2.4.Timestamp ===
406 +== **2.6  ​LED Indicator** ==
410 410  
408 +The CPN01 has an internal LED which is to show the status of different state.
411 411  
412 -Timestamp : 0x6315537b =1662342011
410 +* When power on, CPN01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe)
411 +* Then the LED will be on for 1 second means device is boot normally.
412 +* After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
413 +* For each uplink probe, LED will be on for 500ms.
413 413  
415 +== **2.7  Alarm Base on Timeout** ==
414 414  
415 -== 2.5  Downlink Payload ==
417 +CPL01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
416 416  
417 417  
418 -By default, NMDS200 prints the downlink payload to console port.
420 +**~1. Keep Status: Status to be monitor**
419 419  
420 -[[image:image-20221021111414-18.png]]
422 +Keep Status = 1: Monitor Close to Open event
421 421  
424 +Keep Status = 0: Monitor Open to Close event
422 422  
423 -**Examples:**
424 424  
425 -* (% style="color:#037691" %)**Set TDC**
427 +**2. Keep Time: Timeout to send an Alarm**
426 426  
427 -If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
429 +Range 0 ~~ 65535(0xFFFF) seconds.
428 428  
429 -Payload:    01 00 00 1E    TDC=30S
431 +If keep time = 0, Disable Alarm Base on Timeout feature.
430 430  
431 -Payload:    01 00 00 3C    TDC=60S
433 +If keep time > 0, device will monitor the keep status event and send an alarm when status doesn’t change after timeout.
432 432  
433 -* (% style="color:#037691" %)**Reset**
434 434  
435 -If payload = 0x04FF, it will reset the NMDS200
436 +**AT Command** to configure:
436 436  
437 -* (% style="color:#037691" %)**INTMOD**
438 +**AT+TTRIG=1,30**  ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL01 will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
438 438  
439 -Downlink Payload: 06000003, Set AT+INTMOD=3
440 +**AT+TTIG=0,0 ** ~-~-> Default Value, disable timeout Alarm.
440 440  
442 +== **2.8 Set debug mode** ==
441 441  
442 -== 2.6  ​LED Indicator ==
444 +Feature: Enable or Disable debug mode
443 443  
444 444  
445 -The NMDS200 has an internal LED which is to show the status of different states.
447 +**AT Command: AT+DEBUG**
446 446  
447 -* When the device starts normally, the LED will light up for 1 second.
448 -* After NMDS200 join NB-IoT network. The LED will be ON for 3 seconds.
449 -* For each uplink probe, LED will be on for 500ms.
449 +[[image:image-20221021111629-21.png]]
450 450  
451 +== **2.9 Clear Flash Record** ==
451 451  
453 +Feature: Clear flash storage for data log feature.
452 452  
453 -== 2.7  Distance alarm function ==
455 +**AT Command: AT+CLRDTA**
454 454  
457 +[[image:image-20221021111527-19.png]]
455 455  
456 -(% style="color:blue" %)**AT Command: AT+ALARM1=min,max**
459 +== ** 2.10 Set trigger mode** ==
457 457  
458 -(% style="color:#037691" %)**Example 1:**
461 + AT Command: **AT+TTRMOD**
459 459  
460 -AT+ ALARM1 =60,200  ~/~/ Alarm when moisture lower than 60.
463 +Feature: Set the trigger interrupt mode.
461 461  
462 -AT+ ALARM2 =min,max
465 +[[image:image-20221021111552-20.png]]
463 463  
467 +== **2.11 Set the calculate flag** ==
464 464  
465 -(% style="color:#037691" %)**Example 2:**
469 +Feature: Set the calculate flag
466 466  
467 -AT+ ALARM2 =200,1500  ~/~/ Alarm when temperature lower than 1500
471 +**AT Command: AT+CALCFLAG**
468 468  
473 +[[image:image-20221021111711-22.png]]
469 469  
470 -== 2. Set the number of data to be uploaded and the recording time ==
475 +== **2.12 Set count number** ==
471 471  
477 +Feature: Manually set the count number
472 472  
473 -(% style="color:blue" %)**AT Command:**
479 +**AT Command: AT+SETCNT**
474 474  
475 -(% style="color:#037691" %)**AT+TR=900**(%%)  ~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
481 +[[image:image-20221021111748-24.png]]
476 476  
477 -(% style="color:#037691" %)**AT+NOUD=8**(%%)** ** ~/~/  The device uploads 0 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
483 +== **2.13 Set the number of data to be uploaded and the recording time** ==
478 478  
485 +➢ AT Command:
479 479  
480 -== 2.Read or Clear cached data ==
487 +AT+TR=900  ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
481 481  
482 482  
483 -(% style="color:blue" %)**AT Command:**
490 +AT+NOUD=8  ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
484 484  
485 -(% style="color:#037691" %)**AT+CDP**  (%%) ~/~/ Read cached data
492 +== **2.14 Read or Clear cached data** ==
486 486  
487 -(% style="color:#037691" %)**AT+CDP=0**  (%%) ~/~/ Clear cached data ​
494 + AT Command:
488 488  
489 -[[image:1670408172929-569.png]]
496 +AT+CDP    ~/~/ Read cached data
490 490  
498 +[[image:image-20221021111810-25.png||height="364" width="797"]]
491 491  
492 -== 2.10  ​Firmware Change Log ==
493 493  
501 +AT+CDP=0    ~/~/ Clear cached data ​
494 494  
495 -Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0>>https://www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0]]
503 +== **2.15  Firmware Change Log** ==
496 496  
497 -Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
505 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0>>url:https://www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0]]
498 498  
507 +Upgrade Instruction: [[Upgrade Firmware>>path:#H5.1200BHowtoUpgradeFirmware]]
499 499  
500 -== 2.11  ​Battery Analysis ==
509 +== **2.16  ​Battery Analysis** ==
501 501  
502 -=== 2.11.1  ​Battery Type ===
511 +=== **2.16.1  ​Battery Type** ===
503 503  
513 +The CPN01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
504 504  
505 -The NMDS200 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
515 +The battery is designed to last for several years depends on the actually use environment and update interval. 
506 506  
507 -The battery is designed to last for several years depends on the actual use environment and update interval
517 +The battery related documents as below:
508 508  
509 -The battery-related documents as below:
510 -
511 511  * [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
512 -
513 513  * [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
514 -
515 515  * [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
516 516  
517 517  [[image:image-20221021111911-26.png]] ​
518 518  
525 +=== **2.16.2  Power consumption Analyze** ===
519 519  
520 -=== 2.11.2  Power consumption Analyze ===
521 -
522 -
523 523  Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
524 524  
525 525  Instruction to use as below:
526 526  
527 -(% style="color:blue" %)**Step 1:  **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
531 +**Step 1:  **Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
528 528  
529 -(% style="color:blue" %)**Step 2: **(%%) Open it and choose
533 +**Step 2: ** Open it and choose
530 530  
531 531  * Product Model
532 -
533 533  * Uplink Interval
534 -
535 535  * Working Mode
536 536  
537 537  And the Life expectation in difference case will be shown on the right.
538 538  
539 -[[image:1666596205057-567.png]] ​
541 +[[image:image-20221021111923-27.png||height="253" width="783"]] ​
540 540  
543 +=== **2.16.3  ​Battery Note** ===
541 541  
542 -=== 2.11.3  ​Battery Note ===
543 -
544 -
545 545  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
546 546  
547 +=== **2.16.4  Replace the battery** ===
547 547  
548 -=== 2.11.4  Replace the battery ===
549 +The default battery pack of CPN01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
549 549  
551 += **3. ​ Access NB-IoT Module** =
550 550  
551 -The default battery pack of NMDS200 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
552 -
553 -
554 -= 3. ​ Access NB-IoT Module =
555 -
556 -
557 557  Users can directly access the AT command set of the NB-IoT module.
558 558  
559 559  The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
560 560  
557 +[[image:image-20221021112006-28.png]] ​
561 561  
562 -[[image:image-20221118094449-6.png]]
559 += **4.  Using the AT Commands** =
563 563  
561 +== **4.1  Access AT Commands** ==
564 564  
565 -= 4.  Using the AT Commands =
566 -
567 -== 4.1  Access AT Commands ==
568 -
569 -
570 570  See this link for detail:  [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
571 571  
572 572  AT+<CMD>?  : Help on <CMD>
... ... @@ -577,9 +577,8 @@
577 577  
578 578  AT+<CMD>=?  : Get the value
579 579  
573 +**General Commands**      
580 580  
581 -(% style="color:blue" %)**General Commands**      
582 -
583 583  AT  : Attention       
584 584  
585 585  AT?  : Short Help     
... ... @@ -602,97 +602,125 @@
602 602  
603 603  AT+SERVADDR  : Server Address
604 604  
605 -AT+TR      :  Get or Set record time
597 +AT+TR      : Get or Set record time"
606 606  
607 -AT+NOUD :  Get or Set the number of data to be uploaded
608 608  
609 -AT+CDP     :  Read or Clear cached data
600 +AT+NOUD      : Get or Set the number of data to be uploaded
610 610  
611 -AT+DEBUG:  Enable or Disable debug mode
612 612  
613 -AT+ALARM1:  Get or Set alarm of distance1
603 +AT+CDP     : Read or Clear cached data
614 614  
615 -AT+ALARM2:  Get or Set alarm of distance2
616 616  
617 -AT+GETSENSORVALUE :  Returns the current sensor measurement
606 +AT+ DEBUG   : Enable or Disable debug mode
618 618  
619 -AT+POWERIC :  Get or set the Power IC flag
608 +AT+ TTRIG   : Get or Set Alarm Base on Timeout
620 620  
610 +AT+ TTRMOD   : Get or Set the trigger interrupt mode(0:falling,1:rising)
621 621  
622 -(% style="color:blue" %)**COAP Management**      
612 +AT+ CALCFLAG   : Get or Set the calculate flag
623 623  
624 -AT+URI :  Resource parameters
614 +AT+ CLRC   : Clear current door open count
625 625  
616 +**COAP Management**      
626 626  
627 -(% style="color:blue" %)**UDP Management**
618 +AT+URI            : Resource parameters
628 628  
629 -AT+CFM :  Upload confirmation mode (only valid for UDP)
620 +**UDP Management**
630 630  
622 +AT+CFM          : Upload confirmation mode (only valid for UDP)
631 631  
632 -(% style="color:blue" %)**MQTT Management**
624 +**MQTT Management**
633 633  
634 -AT+CLIENT  : Get or Set MQTT client
626 +AT+CLIENT               : Get or Set MQTT client
635 635  
636 -AT+UNAME : Get or Set MQTT Username
628 +AT+UNAME  : Get or Set MQTT Username
637 637  
638 -AT+PWD  :  Get or Set MQTT password
630 +AT+PWD                  : Get or Set MQTT password
639 639  
640 -AT+PUBTOPIC :  Get or Set MQTT publish topic
632 +AT+PUBTOPIC  : Get or Set MQTT publish topic
641 641  
642 -AT+SUBTOPIC :  Get or Set MQTT subscription topic
634 +AT+SUBTOPIC  : Get or Set MQTT subscription topic
643 643  
636 +**Information**          
644 644  
645 -(% style="color:blue" %)**Information**          
638 +AT+FDR  : Factory Data Reset
646 646  
647 -AT+FDR :  Factory Data Reset
640 +AT+PWORD  : Serial Access Password
648 648  
649 -AT+PWORD :  Serial Access Password
642 += **​5.  FAQ** =
650 650  
644 +== **5.1 ​ How to Upgrade Firmware** ==
651 651  
652 -= ​5.  FAQ =
646 +User can upgrade the firmware for 1) bug fix, 2) new feature release.
653 653  
654 -== 5.1 How to Upgrade Firmware ==
648 +Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
655 655  
650 +**Notice, **CPN01 **and **CPN01 **share the same mother board. They use the same connection and method to update.**
656 656  
657 -User can upgrade the firmware for 1) bug fix, 2) new feature release.
652 +== **5.2  Can I calibrate CPN01 to different soil types?** ==
658 658  
659 -Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
654 +CPN01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].
660 660  
661 -(% style="color:red" %)**Notice: **(% style="color:blue" %)**NMDS200** (%%)**and (% style="color:blue" %)LMDS200(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.**
656 += **6.  Trouble Shooting** =
662 662  
658 +== **6.1  ​Connection problem when uploading firmware** ==
663 663  
664 -= 6.  Trouble Shooting =
660 +**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
665 665  
666 -== 6.1  Connection problem when uploading firmware ==
662 +== **6.2  AT Command input doesn't work** ==
667 667  
664 +In the case if user can see the console output but can't type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn't send **ENTER** while press the send key, user need to add ENTER in their string.
668 668  
669 -(% style="color:blue" %)**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
666 += **7. Order Info** =
670 670  
668 +Part Number**:** CPN01
671 671  
672 -== 6.2  AT Command input doesn't work ==
670 += **8Packing Info** =
673 673  
672 +**Package Includes**:
674 674  
675 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string.
674 +* CPN01 NB-IoT Soil Moisture & EC Sensor x 1
675 +* External antenna x 1
676 676  
677 +**Dimension and weight**:
677 677  
678 -= 7. ​ Order Info =
679 +* Size: 195 x 125 x 55 mm
680 +* Weight:   420g
679 679  
682 += **9.  Support** =
680 680  
681 -Part Number:(% style="color:blue" %)** NMDS200**
684 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
685 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
682 682  
687 +​
683 683  
684 -= 8.  Packing Info =
685 685  
686 686  
687 -(% style="color:blue" %)**Package Includes**:
688 688  
689 -* NMDS200 NB-IoT Microwave Radar Distance Sensor x 1
690 690  
691 -= 9.  Support =
692 692  
693 693  
694 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
695 695  
696 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
697 697  
698 -​
697 +
698 +
699 +
700 +
701 +
702 +
703 +
704 +
705 +
706 +
707 +
708 +
709 +
710 +
711 +
712 +
713 +
714 +
715 +
716 +
717 +
718 +
1666596205057-567.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -179.8 KB
Content
1670404362039-351.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -492.6 KB
Content
1670405841875-916.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.1 KB
Content
1670405928926-116.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.7 KB
Content
1670406036256-101.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -181.0 KB
Content
1670406261143-723.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -77.9 KB
Content
1670407401682-959.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -23.7 KB
Content
1670408172929-569.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -211.8 KB
Content
LMDS200_10.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -39.9 KB
Content
image-20221023000439-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -82.1 KB
Content
image-20221117105556-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -133.3 KB
Content
image-20221117114459-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -14.9 KB
Content
image-20221117114842-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -964.1 KB
Content
image-20221117114937-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -79.1 KB
Content
image-20221117114949-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -33.4 KB
Content
image-20221117115010-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -40.4 KB
Content
image-20221117142300-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -147.8 KB
Content
image-20221117145932-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -51.9 KB
Content
image-20221117150312-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -8.7 KB
Content
image-20221118092935-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -13.1 KB
Content
image-20221118093144-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -11.7 KB
Content
image-20221118093512-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -9.5 KB
Content
image-20221118093658-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -12.7 KB
Content
image-20221118094227-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -29.2 KB
Content
image-20221118094449-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.5 KB
Content
image-20221118103445-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -20.4 KB
Content
image-20221118103453-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -46.2 KB
Content
image-20221118103547-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -43.5 KB
Content
image-20221207170748-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -26.1 KB
Content
image-20221207170748-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -29.9 KB
Content
image-20221207173200-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.7 KB
Content
image-20221207173300-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -77.0 KB
Content
image-20221208090742-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -79.7 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0