From version < 83.6 >
edited by Xiaoling
on 2022/12/08 11:16
To version < 29.1 >
edited by David Huang
on 2022/10/21 11:19
>
Change comment: Uploaded new attachment "image-20221021111923-27.png", version {1}

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
1 +CPN01- NB-IoT Outdoor Open/Close Dry Contact Sensor User Manual
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Xiaoling
1 +XWiki.David
Content
... ... @@ -1,47 +1,36 @@
1 1  (% style="text-align:center" %)
2 -[[image:LMDS200_10.jpg]]
2 +[[image:http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652856952171-363.png?rev=1.1||alt="1652856952171-363.png"]]
3 3  
4 4  
5 -**Table of Contents:**
5 +**~1. Introduction**
6 6  
7 -{{toc/}}
7 +**1.1 ​**What is CPN01 **NB-IOT** Pulse/Contact Sensor
8 8  
9 +The Dragino CPL01 is a **NB-IOT Contact Sensor**. It detects open/close status and uplink to IoT server via LoRaWAN network. user can see the dry contact status, open time, open counts in the IoT Server.
9 9  
11 +The CPL01 will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculate last open duration. User can also disable the uplink for each open/close event, instead, device can count each open event and uplink periodically.
10 10  
13 +CPL01 has the open alarm feature, user can set this feature so device will send Alarm if the contact has been open for a certain time.
11 11  
12 -= 1.  Introduction =
15 +CPL01 is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures.
13 13  
14 -== 1.1 ​ What is NMDS200 NB-IoT Microwave Radar Distance Sensor ==
17 +NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity and spectrum efficiency, especially in deep coverage.
18 +\\CPN01 supports different uplink methods include **TCP,MQTT,UDP and CoAP  **for different application requirement.
19 +\\CPN01 is powered by  **8500mAh Li-SOCI2 battery**, It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method)
20 +\\To use CPN01, user needs to check if there is NB-IoT coverage in local area and with the bands CPN01 supports. If the local operate support it, user needs to get a **NB-IoT SIM card** from local operator and install CPN01 to get NB-IoT network connection
15 15  
22 +​
16 16  
17 -(((
18 -The Dragino NMDS200 is a(% style="color:blue" %)** NB-IoT Microwave Radar distance sensor**(%%). It uses (% style="color:blue" %)**24Ghz Microwave**(%%) to detect the distance between sensor and different objects. Compare vs ultrasonic or Lidar measurement method, Microwave Radar is (% style="color:blue" %)**more reliable for condensation / dusty environment**(%%). It can sense correct distance even there is water or thick dust on top of the sensor.
19 19  
20 -The NMDS200 can be applied to scenarios such as horizontal distance measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, etc.
25 +**​1.2 Features**
21 21  
22 -NMDS200 can (% style="color:blue" %)**measure two distances**(%%): the closest object and next object behind the closest one.
23 -
24 -NMDS200 (% style="color:blue" %)**supports Alarm Feature**(%%), user can set the NMDS200 to uplink data in a short interval when the distance is out of configured range.
25 -
26 -NarrowBand-Internet of Things (NB-IoT) is a (% style="color:blue" %)**standards-based low power wide area (LPWA) technology**(%%) developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity, and spectrum efficiency, especially in deep coverage.
27 -
28 -NMDS200 (% style="color:blue" %)**supports different uplink**(%%) methods including (% style="color:blue" %)**TCP, MQTT, UDP, and CoAP**(%%) for different application requirements.
29 -
30 -NMDS200 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**,(%%) It is designed for long-term use of up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method)
31 -
32 -To use NMDS200, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that NMDS200 supports. If local operator support it, user needs to get a** (% style="color:blue" %)NB-IoT SIM card(%%)** from the operator and install into NMDS200 to get NB-IoT network connection.
33 -)))
34 -
35 -
36 -== ​1.2  Features ==
37 -
38 -
39 39  * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD
40 -* Short uplink interval for Distance Alarm
28 +* Open/Close detect
29 +* Open/Close statistics
41 41  * Monitor Battery Level
42 -* Microwave Radar for distance detection
31 +* Uplink on periodically and open/close event
43 43  * Datalog feature
44 -* Uplink periodically
33 +* Uplink on periodically
45 45  * Downlink to change configure
46 46  * Wall Mountable
47 47  * Outdoor Use
... ... @@ -48,525 +48,524 @@
48 48  * Ultra-Low Power consumption
49 49  * AT Commands to change parameters
50 50  * Micro SIM card slot for NB-IoT SIM
51 -* 8500mAh Battery for long-term use
40 +* 8500mAh Battery for long term use
52 52  
53 -== 1.3 Radar probe specification ==
42 +**1.3  Specification**
54 54  
44 +**Common DC Characteristics:**
55 55  
56 -* Measuring Method: FMCW
57 -* Frequency: 24.000 24.500 GHz
58 -* Measurement output power: 6dBm
59 -* Measure range: 0.5 20m
60 -* Accuracy: ±0.1m
61 -* Resolution: 0.01m
62 -* Horizontal Angel: 78°
63 -* Vertical Angel: 23°
46 +* Supply Voltage: 2.1v ~~ 3.6v
47 +* Operating Temperature: -40 ~~ 85°C
64 64  
65 -== 1.4  Storage Temperature ==
49 +**NB-IoT Spec:**
66 66  
51 +* - B1 @H-FDD: 2100MHz
52 +* - B3 @H-FDD: 1800MHz
53 +* - B8 @H-FDD: 900MHz
54 +* - B5 @H-FDD: 850MHz
55 +* - B20 @H-FDD: 800MHz
56 +* - B28 @H-FDD: 700MHz
67 67  
68 - -40°C to +85°C
58 +**1.4 Installation**
69 69  
60 +Connect CPL01 to an Open Close sensor like below. So it can detect the open/close event.
70 70  
71 -== 1.5 Applications ==
62 +​[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image001.png]] [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image002.png]]
72 72  
64 +**1.5 ​Applications**
73 73  
74 -* Horizontal distance measurement
75 -* Liquid level measurement
76 -* Parking management system
77 -* Object proximity and presence detection
78 -* Intelligent trash can management system
79 -* Robot obstacle avoidance
80 -* Automatic control
81 -* Sewer
82 -* Bottom water level monitoring
66 +* Open/Close Detection
67 +* Pulse meter application
68 +* Dry Contact Detection
83 83  
84 -== 1.6  Specification ==
70 +**1.6 Mechanical**
85 85  
72 +​[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image003.png]]
86 86  
87 -(% style="color:blue" %)**Common DC Characteristics:**
74 +**~ 1.7 Pin Definitions and Switch**
88 88  
89 -* Supply Voltage: 2.1v ~~ 3.6v
90 -* Operating Temperature: 0 ~~ 70°C
76 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image004.png]]
91 91  
92 -(% style="color:blue" %)**NB-IoT Spec:**
78 +**1.7.1 Pin Definition**
93 93  
94 -* B1 @H-FDD: 2100MHz
95 -* B3 @H-FDD: 1800MHz
96 -* B8 @H-FDD: 900MHz
97 -* B5 @H-FDD: 850MHz
98 -* B20 @H-FDD: 800MHz
99 -* B28 @H-FDD: 700MHz
80 +CPL01 is pre-configured to connect to two external wires. The other pins are not used. If user wants to know more about other pins, please refer to the user manual of LSN50v2 at: [[https:~~/~~/www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0>>url:https://www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0]]
100 100  
101 -== 1.7  Installation ==
82 +**1.7.2 Jumper JP2(Power ON/OFF)**
102 102  
103 103  
104 -Sensor measure direction and angle is as below. When install the sensor, please make sure the sensor direct to object.
85 +Power on Device when putting this jumper.
105 105  
106 106  
107 -[[image:image-20221207170748-1.png]] [[image:image-20221207170748-2.png||height="366" width="672"]]
108 108  
89 +**1.7.3 BOOT MODE / SW1**
109 109  
110 110  
111 -== 1.8  Pin Definitions and Switch ==
92 +1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run.
112 112  
94 +2) Flash: work mode, the device starts to work and send out console output for further debug
113 113  
114 -[[image:1670404362039-351.png]]
115 115  
116 116  
117 -= 2.  Use NMDS200 to communicate with IoT Server =
98 +**1.7.4 Reset Button**
118 118  
119 -== 2.1  How it works ==
120 120  
101 +Press to reboot the device.
121 121  
122 -The NB-IoT network will forward this value to IoT server via the protocol defined by NMDS200.
123 123  
124 -The diagram below shows the working flow in the default firmware of NMDS200:
125 125  
126 -[[image:image-20221021110615-5.png]]
105 +**1.7.5 LED**
127 127  
128 128  
129 -== 2.2 ​ Configure NMDS200 ==
108 +It will flash:
130 130  
110 +1. Boot the device in flash mode
111 +1. Send an uplink packet
131 131  
132 -To use NMDS200 in your city, make sure to meet below requirements:
133 133  
134 -* Your local operator has already distributed an NB-IoT Network.
135 -* The local NB-IoT network used the band that NMDS200 supports.
136 -* Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
114 +**2.  Use CPN01 to communicate with IoT Server**
137 137  
138 -Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The NMDS200 will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server.
116 +**2.1  How it works**
139 139  
140 -[[image:image-20221208090742-1.png]]
118 +The CPN01 is equipped with a NB-IoT module, the pre-loaded firmware in CPN01 will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by CPN01.
141 141  
120 +The diagram below shows the working flow in default firmware of CPN01:
142 142  
143 -=== 2.2.1 Insert NB-IoT SIM card ===
122 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image005.png||alt="说明: image-20220708101605-2.png"]]
144 144  
124 +**2.2 ​ Configure the CPN01**
145 145  
146 -Insert the NB-IoT Card get from your provider.
126 +**2.2.1 Test Requirement**
147 147  
148 -User needs to take out the NB-IoT module and insert the SIM card like below:
128 +To use CPN01 in your city, make sure meet below requirements:
149 149  
150 -[[image:image-20221021110745-6.png]] ​
130 +* Your local operator has already distributed a NB-IoT Network there.
131 +* The local NB-IoT network used the band that CPN01 supports.
132 +* Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
151 151  
134 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The CPN01 will use CoAP(120.24.4.116:5683) or raw UDP(120.24.4.116:5601) or MQTT(120.24.4.116:1883)or TCP(120.24.4.116:5600)protocol to send data to the test server
152 152  
153 -=== 2.2.2 Connect USB – TTL to NMDS200 and configure it ===
136 +
154 154  
138 +**2.2.2 Insert SIM card**
155 155  
156 -User need to configure NMDS200 via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NMDS200 support AT Commands, user can use a USB to TTL adapter to connect to NMDS200 and use AT Commands to configure it, as below.
140 +Insert the NB-IoT Card get from your provider.
157 157  
158 -(% style="color:blue" %)**Connection:**
142 +User need to take out the NB-IoT module and insert the SIM card like below:
159 159  
160 -(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
144 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image006.png||alt="说明: 1657249468462-536.png"]]
161 161  
162 -(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD**
146 +**2.2.3 Connect USB TTL to CPN01 to configure it**
163 163  
164 -(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD**
148 +User need to configure CPN01 via serial port to set the **Server Address** / **Uplink Topic** to define where and how-to uplink packets. CPN01 support AT Commands, user can use a USB to TTL adapter to connect to CPN01 and use AT Commands to configure it, as below.
165 165  
150 +**Connection:**
166 166  
167 -In the PC, use below serial tool settings:
152 + USB TTL GND <~-~-~-~-> GND
168 168  
169 -* Baud:  (% style="color:red" %)**9600**
154 + USB TTL TXD <~-~-~-~-> UART_RXD
170 170  
171 -* Data bits:** (% style="color:red" %)8(%%)**
156 + USB TTL RXD <~-~-~-~-> UART_TXD
172 172  
173 -* Stop bits: (% style="color:red" %)**1**
158 +In the PC, use below serial tool settings:
174 174  
175 -* Parity:  (% style="color:red" %)**None**
160 +* Baud:  **9600**
161 +* Data bits:** 8**
162 +* Stop bits: **1**
163 +* Parity:  **None**
164 +* Flow Control: **None**
176 176  
177 -* Flow Control: (% style="color:red" %)**None**
166 +Make sure the switch is in FLASH position, then power on device by connecting the jumper on CPN01. CPN01 will output system info once power on as below, we can enter the **password: 12345678** to access AT Command input.
178 178  
179 -Make sure the switch is in FLASH position, then power on NMDS200 by connecting the (% style="color:orange" %)**Yellow Jumper**(%%).
168 +​[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image007.png]]
180 180  
181 -​[[image:image-20221021110817-7.png]]
170 +**Note: the valid AT Commands can be found at:  **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
182 182  
183 -NMDS200 will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input.
172 +**2.2.4 Use CoAP protocol to uplink data**
184 184  
174 +**Note: if you don't have CoAP server, you can refer this link to set up one: **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
185 185  
186 -(% style="color:red" %)**Note: the valid AT Commands can be found at:  **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
176 +**Use below commands:**
187 187  
178 +* **AT+PRO=1**   ~/~/ Set to use CoAP protocol to uplink
179 +* **AT+SERVADDR=120.24.4.116,5683   ** ~/~/ to set CoAP server address and port
180 +* **AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** ~/~/Set COAP resource path
188 188  
189 -
190 -=== 2.2.3 Use CoAP protocol to uplink data ===
191 -
192 -
193 -(% style="color:red" %)**Note: if you don't have a CoAP server, you can refer this link to set up a CoAP server: **(%%)[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
194 -
195 -
196 -(% style="color:blue" %)**Use below commands in NMDS200:**
197 -
198 -* (% style="color:#037691" %)**AT+PRO=1**                (%%) ~/~/ Set to use CoAP protocol to uplink
199 -
200 -* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5683   ** (%%) ~/~/ Set CoAP server address and port
201 -
202 -* (% style="color:#037691" %)**AT+URI=0,0,11,2,"mqtt" ** (%%) ~/~/  Set CoAP resource path
203 -
204 204  For parameter description, please refer to AT command set
205 205  
206 -[[image:image-20221021110948-8.png]]
184 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image008.png]]
207 207  
186 +After configure the server address and **reset the device** (via AT+ATZ ), CPN01 will start to uplink sensor values to CoAP server.
208 208  
209 -After configuring the server address and (% style="color:green" %)**reset NMDS200**(%%) (via AT+ATZ ), NMDS200 will start to uplink sensor values to the CoAP server.
188 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image009.png]]
210 210  
211 -[[image:1670405841875-916.png]]
190 +**2.2.5 Use UDP protocol to uplink data(Default protocol)**
212 212  
192 +This feature is supported since firmware version v1.0.1
213 213  
214 -=== 2.2.4 Use UDP protocol to uplink data(Default protocol) ===
194 +* **AT+PRO=2   ** ~/~/ Set to use UDP protocol to uplink
195 +* **AT+SERVADDR=120.24.4.116,5601   ** ~/~/ to set UDP server address and port
196 +* **AT+CFM=1       ** ~/~/If the server does not respond, this command is unnecessary
215 215  
198 +​ [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image010.png]]
216 216  
217 -(% style="color:blue" %)**AT Commands:**
200 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image011.png||alt="说明: 1657249930215-289.png"]]
218 218  
219 -* (% style="color:#037691" %)**AT+PRO=2   ** (%%) ~/~/  Set to use UDP protocol to uplink
220 -
221 -* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/  Set UDP server address and port
222 -
223 -* (% style="color:#037691" %)**AT+CFM=1       ** (%%) ~/~/  If the server does not respond, this command is unnecessary
224 -
225 -​ [[image:image-20221021111025-10.png]]
226 -
227 -
228 -[[image:image-20221021111033-11.png||height="241" width="576"]]
229 -
230 230  ​
231 231  
232 -=== 2.2.5 Use MQTT protocol to uplink data ===
204 +**2.2.6 Use MQTT protocol to uplink data**
233 233  
206 +This feature is supported since firmware version v110
234 234  
235 -(% style="color:blue" %)**AT Commands:**
208 +* **AT+PRO=3   ** ~/~/Set to use MQTT protocol to uplink
209 +* **AT+SERVADDR=120.24.4.116,1883   ** ~/~/Set MQTT server address and port
210 +* **AT+CLIENT=CLIENT       ** ~/~/Set up the CLIENT of MQTT
211 +* **AT+UNAME=UNAME                               **~/~/Set the username of MQTT
212 +* **AT+PWD=PWD                                        **~/~/Set the password of MQTT
213 +* **AT+PUBTOPIC=NSE01_PUB                    **~/~/Set the sending topic of MQTT
214 +* **AT+SUBTOPIC=NSE01_SUB          ** ~/~/Set the subscription topic of MQTT
236 236  
237 -* (% style="color:#037691" %)**AT+PRO=3   ** (%%) ~/~/  Set to use MQTT protocol to uplink
216 + [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image012.png]]
238 238  
239 -* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,1883   ** (%%) ~/~/  Set MQTT server address and port
218 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image013.png]]
240 240  
241 -* (% style="color:#037691" %)**AT+CLIENT=CLIENT       ** (%%) ~/~/  Set up the CLIENT of MQTT
242 -
243 -* (% style="color:#037691" %)**AT+UNAME=UNAME                     **(%%)** **~/~/  Set the username of MQTT
244 -
245 -* (% style="color:#037691" %)**AT+PWD=PWD                         **(%%)** **~/~/  Set the password of MQTT
246 -
247 -* (% style="color:#037691" %)**AT+PUBTOPIC=NSE01_PUB              **(%%)** **~/~/  Set the sending topic of MQTT
248 -
249 -* (% style="color:#037691" %)**AT+SUBTOPIC=NSE01_SUB          ** (%%) ~/~/  Set the subscription topic of MQTT
250 -
251 -​ [[image:image-20221118103445-7.png]]
252 -
253 -
254 -[[image:1670405928926-116.png]]
255 -
256 256  ​
257 257  
258 -MQTT protocol has a much higher power consumption compare with UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
222 +MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
259 259  
224 +**2.2.7 Use TCP protocol to uplink data**
260 260  
261 -=== 2.2.6 Use TCP protocol to uplink data ===
226 +This feature is supported since firmware version v110
262 262  
228 +* **AT+PRO=4   ** ~/~/ Set to use TCP protocol to uplink
229 +* **AT+SERVADDR=120.24.4.116,5600   ** ~/~/ to set TCP server address and port
263 263  
264 -(% style="color:blue" %)**AT Commands:**
231 + [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image014.png]]
265 265  
266 -* (% style="color:#037691" %)**AT+PRO=4   ** (%%) ~/~/  Set to use TCP protocol to uplink
233 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image015.png||alt="说明: 1657250255956-604.png"]]
267 267  
268 -* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5600   ** (%%) ~/~/  Set TCP server address and port
269 -
270 -​ [[image:1670406036256-101.png||height="676" width="713"]]
271 -
272 -
273 -[[image:image-20221021111131-15.png]]
274 -
275 275  ​
276 276  
277 -=== 2.2.7 Change Update Interval ===
237 +**2.2.8 Change Update Interval**
278 278  
239 +User can use below command to change the **uplink interval**.
279 279  
280 -User can use below command to change the (% style="color:blue" %)**uplink interval**.
241 +* **AT+TDC=600      ** ~/~/ Set Update Interval to 600s
281 281  
282 -* (% style="color:#037691" %)**AT+TDC=7200      ** (%%) ~/~/ Set Update Interval to 7200s (4 hours)
243 +**NOTE:**
283 283  
284 -(% style="color:red" %)**NOTE:**
245 +**~1. By default, the device will send an uplink message every 1 hour.**
285 285  
286 -1By default, the device will send an uplink message every 4 hour.
247 +**2.3  Uplink Payload**
287 287  
249 +In this mode, uplink payload includes 87 bytes in total by default.
288 288  
289 -== 2.3  Uplink Payload ==
251 +Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded.
290 290  
253 +|**Size(bytes)**|**8**|**2**|**2**|**1**|**1**|**1**|**2**|**2**|4
254 +|**Value**|[[Device ID>>path:#H2.4.1A0A0DeviceID]]|[[Ver>>path:#H2.4.2A0VersionInfo]]|[[BAT>>path:#H2.4.3A0BatteryInfo]]|[[Signal Strength>>path:#H2.4.4A0SignalStrength]]|MOD|[[Interrupt>>path:#H2.4.8A0DigitalInterrupt]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|Time stamp
291 291  
292 -The uplink payload includes 23 bytes in total by default.
293 293  
294 -Each time the device uploads a data package. The user can use the AT+NOUD command to upload the recorded data.Up to 32 sets of recorded data can be uploaded.
257 +|2|2|4|8 group
258 +|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|Time stamp|...
295 295  
260 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the CPN01 uplink data.
296 296  
297 -(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
298 -|=(% scope="row" style="width: 50px;" %)**Size(bytes)**|(% style="width:50px" %)**8**|(% style="width:20px" %)**2**|(% style="width:20px" %)**2**|(% style="width:65px" %)**1**|(% style="width:25px" %)**1**|(% style="width:50px" %)**1**|(% style="width:90px" %)**2**|(% style="width:100px" %)**2**
299 -|=(% style="width: 93px;" %)**Value**|(% style="width:67px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:45px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:54px" %)MOD|(% style="width:62px" %)Exit flag|(% style="width:94px" %) [[Distance 1>>||anchor="H2.4.5A0Distance"]] |(% style="width:93px" %) [[Distance  2>>||anchor="H2.4.5A0Distance"]]
262 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image016.png]]
300 300  
301 -(% border="1.5" style="background-color:#ffffcc; color:green; width:450px" %)
302 -|(% style="width:50px" %)**4**|(% style="width:90px" %)**2**|(% style="width:90px" %)**2**|(% style="width:60px" %)**4**|(% style="width:50px" %)(((
303 -**1-32 group**
304 -)))
305 -|(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.6A0Timestamp"]]| Distance 1 | Distance  2|(% style="width:67px" %)Time stamp|(% style="width:74px" %)...
264 +The payload is ASCII string, representative same HEX:
306 306  
307 -If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NMDS200 uplink data.
266 +0xf86778705021331700640c7817010001000000090000026315537b 0100000b02000002663510fed0100000e0200000263510f39010000000000000063510e85010000000000000063510d2e010000000000000063510c7a010000000000000063510bc6010000000000000063510954010000000000000063510882 where:
308 308  
309 -[[image:1670406261143-723.png]]
268 +* **Device ID: 0x f867787050213317 = f867787050213317**
269 +* **Version: 0x0064=100=1.0.0**
310 310  
271 +* **BAT: 0x0c78 = 3192 mV = 3.192V**
272 +* **Singal: 0x17 = 23**
273 +* **Mod: 0x01 = 1**
274 +* **Calculate Flag: 0x00= 0**
275 +* **Contact Status: 0x00= 0**
276 +* **Alarm:0x00 =0**
277 +* **Total pulse:0x09 =0**
278 +* **The last open duration:0x02 =2**
279 +* **Time stamp : 0x6315537b =1662342011**
280 +* **Contact Status, Total pulse, Calculate Flag, The last open duration ,Time stamp : 0100000b0200002663510fed**
281 +* **8 sets of recorded data: Contact Status, Total pulse, Calculate Flag, The last open duration ,Time stamp : 0100000e0200002663510f39,.......**
311 311  
312 -The payload is ASCII string, representative same HEX: f867787050471071  0064  0cc3  09  01  00 00ef  013d  6390453d
283 +**2.4  Payload Explanation and Sensor Interface**
313 313  
314 -**0x (% style="color:red" %)__f867787050471071__  (% style="color:blue" %)__0064__ (% style="color:green" %) __0cc3__(% style="color:#00b0f0" %) 0__9__(% style="color:#7030a0" %) __01__(% style="color:#0020b0" %) __00__ (% style="color:#420042" %)__00ef__(% style="color:#660066" %) (% style="color:#663300" %)__013d__ (% style="color:#d60093" %)__6390453d__(%%)**
285 +**2.4.1  Device ID**
315 315  
316 -**where:**
287 +By default, the Device ID equal to the last 15 bits of IMEI.
317 317  
318 -* (% style="color:#037691" %)**Device ID:**(%%) 0x f867787050471071 = f867787050471071
289 +User can use **AT+DEUI** to set Device ID
319 319  
320 -* (% style="color:#037691" %)**Version:**(%%)  0x0064=100=1.0.0
291 +**Example:**
321 321  
322 -* (% style="color:#037691" %)**BAT :**(%%)  0x0cc3 = 3267 mV = 3.267V
293 +AT+DEUI=868411056754138
323 323  
324 -* (% style="color:#037691" %)**Singal: **(%%)0x09 = 9
295 +The Device ID is stored in a none-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID.
325 325  
326 -* (% style="color:#037691" %)**Mod:**(%%)  0x01 = 1
297 +**2.4.2  Version Info**
327 327  
328 -* (% style="color:#037691" %)**Exit flag: **(%%)0x00 =0
299 +Specify the software version: 0x64=100, means firmware version 1.00.
329 329  
330 -* (% style="color:#037691" %)**Distance 1: **(%%)0x00ef=239
301 +For example: 0x00 64 : this device is CPN01 with firmware version 1.0.0.
331 331  
332 -* (% style="color:#037691" %)**Distance 2: **(%%)0x013d =317
303 +**2.4.3  Battery Info**
333 333  
334 -* (% style="color:#037691" %)**Timestamp: **(%%)0x6390453d =1670399293 (Unix Time)
305 +Check the battery voltage for CPN01.
335 335  
307 +Ex1: 0x0B45 = 2885mV
336 336  
337 -== 2.4  Payload Explanation and Sensor Interface ==
309 +Ex2: 0x0B49 = 2889mV
338 338  
339 -=== 2.4.1  Device ID ===
311 +**2.4.4  Signal Strength**
340 340  
313 +NB-IoT Network signal Strength.
341 341  
342 -By default, the Device ID is equal to the last 15 bits of IMEI.
315 +**Ex1: 0x1d = 29**
343 343  
344 -User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID
317 +**0**  -113dBm or less
345 345  
346 -**Example:**
319 +**1**  -111dBm
347 347  
348 -AT+DEUI=868411056754138
321 +**2...30** -109dBm... -53dBm
349 349  
350 -The Device ID is stored in a non-erase area, Upgrade the firmware or run AT+FDR won't erase the Device ID.
323 +**31**   -51dBm or greater
351 351  
325 +**99**    Not known or not detectable
352 352  
353 -=== 2.4. Version Info ===
327 +**2.4.5 Calculate Flag**
354 354  
329 +The calculate flag is a user define field, IoT server can use this filed to handle different meter with different pulse factor. For example, if there are 100 water meters, meter 1 ~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse.
355 355  
356 -Specify the software version: 0x64=100, which means firmware version 1.00.
331 +User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation.
357 357  
358 -For example 0x00 64 : This device is NMDS200 1 with firmware version 1.0.0.
333 +Default value: 0. 
359 359  
335 +Range (6 bits): (b)000000 ~~ (b) 111111
360 360  
361 -=== 2.4.3  Battery Info ===
337 +**2.4.6  Alarm**
362 362  
339 +See [[Alarm Base on Timeout>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H3.5AlarmBaseonTimeout]]
363 363  
364 -Check the battery voltage for NMDS200.
341 +**2.4.7 Contact Status**
365 365  
366 -Ex1: 0x0B45 = 2885mV
343 +0: Open
367 367  
368 -Ex2: 0x0B49 = 2889mV
345 +1: Close
369 369  
347 +**2.4.8 Total pulse**
370 370  
371 -=== 2.4.4  Signal Strength ===
349 +Total pulse/counting base on dry [[contact trigger event>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.2SensorConfiguration2CFPORT3D4]]
372 372  
351 +Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215
373 373  
374 -NB-IoT Network signal Strength.
353 +**2.4.9 The last open duration**
375 375  
376 -(% style="color:blue" %)**Ex1: 0x1d = 29**
355 +Dry Contact last open duration.
377 377  
378 -(% style="color:#037691" %)**0** (%%) -113dBm or less
357 +Unit: min.
379 379  
380 -(% style="color:#037691" %)**1**  (%%) -111dBm
359 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image017.png]]
381 381  
382 -(% style="color:#037691" %)**2...30** (%%) -109dBm... -53dBm
383 383  
384 -(% style="color:#037691" %)**31** (%%) -51dBm or greater
362 +**2.4.1 Timestamp**
385 385  
386 -(% style="color:#037691" %)**99** (%%) Not known or not detectable
364 +Time stamp : 0x6315537b =1662342011
387 387  
366 +Convert Unix timestamp to time 2022-9-5 9:40:11.
388 388  
389 -=== 2.4.5  Distance ===
368 +**~ **
390 390  
370 +**2.5  Downlink Payload**
391 391  
392 -[[image:1670407401682-959.png]]
372 +By default, CPN01 prints the downlink payload to console port.
393 393  
374 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image018.png||alt="说明: image-20220708133731-5.png"]] ​
394 394  
395 -(% style="color:blue" %)**Object1 Distance:**
376 +**Examples:**
396 396  
397 -Distance between sensor probe to the first object. (unit: cm)
378 +* **Set TDC**
398 398  
399 -For example, if the data you get from the register is 0x02 0x05, the distance between the sensor and the measured object is
380 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
400 400  
401 -(% style="color:blue" %)**0205(H) = 517 (D) = 517 cm.**
382 +Payload:    01 00 00 1E    TDC=30S
402 402  
384 +Payload:    01 00 00 3C    TDC=60S
403 403  
404 -(% style="color:blue" %)**Object2 Distance:**
386 +* **Reset**
405 405  
406 -Distance between sensor probe to the second object. (unit: cm)
388 +If payload = 0x04FF, it will reset the NSE01
407 407  
390 +* **INTMOD**
408 408  
409 -=== 2.4.6  Timestamp ===
392 +Downlink Payload: 06000003, Set AT+INTMOD=3
410 410  
394 +**2.6  ​LED Indicator**
411 411  
412 -Timestamp : 0x6315537b =1662342011
396 +The CPN01 has an internal LED which is to show the status of different state.
413 413  
398 +* When power on, CPN01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe)
399 +* Then the LED will be on for 1 second means device is boot normally.
400 +* After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
401 +* For each uplink probe, LED will be on for 500ms.
414 414  
415 -== 2. Downlink Payload ==
403 +**2.7 ** Alarm Base on Timeout
416 416  
405 +CPL01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
417 417  
418 -By default, NMDS200 prints the downlink payload to console port.
419 419  
420 -[[image:image-20221021111414-18.png]]
408 +**~1. Keep Status: Status to be monitor**
421 421  
410 +Keep Status = 1: Monitor Close to Open event
422 422  
423 -**Examples:**
412 +Keep Status = 0: Monitor Open to Close event
424 424  
425 -* (% style="color:#037691" %)**Set TDC**
426 426  
427 -If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
415 +**2. Keep Time: Timeout to send an Alarm**
428 428  
429 -Payload:    01 00 00 1E    TDC=30S
417 +Range 0 ~~ 65535(0xFFFF) seconds.
430 430  
431 -Payload:    01 00 00 3C    TDC=60S
419 +If keep time = 0, Disable Alarm Base on Timeout feature.
432 432  
433 -* (% style="color:#037691" %)**Reset**
421 +If keep time > 0, device will monitor the keep status event and send an alarm when status doesn’t change after timeout.
434 434  
435 -If payload = 0x04FF, it will reset the NMDS200
436 436  
437 -* (% style="color:#037691" %)**INTMOD**
424 +**AT Command** to configure:
438 438  
439 -Downlink Payload: 06000003, Set AT+INTMOD=3
426 +**AT+TTRIG=1,30**  ~-~-> When the **Keep Status** change from connect to disconnect, and device remains in disconnect status for more than 30 seconds. CPL01 will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
440 440  
428 +**AT+TTIG=0,0 ** ~-~-> Default Value, disable timeout Alarm.
441 441  
442 -== 2.6  ​LED Indicator ==
430 +**2.8** Set debug mode
443 443  
432 +Feature: Enable or Disable debug mode
444 444  
445 -The NMDS200 has an internal LED which is to show the status of different states.
446 446  
447 -* When the device starts normally, the LED will light up for 1 second.
448 -* After NMDS200 join NB-IoT network. The LED will be ON for 3 seconds.
449 -* For each uplink probe, LED will be on for 500ms.
435 +**AT Command: AT+DEBUG**
450 450  
437 +|**Command Example**|**Function**|**Response**
438 +|AT+DEBUG =0|Disable debug mode to 0|OK
439 +|AT+ DEBUG =1|Enable debug mode to 1|OK
451 451  
441 +== 2.9 Clear Flash Record ==
452 452  
453 -== 2.7  Distance alarm function ==
443 +Feature: Clear flash storage for data log feature.
454 454  
445 +**AT Command: AT+CLRDTA**
455 455  
456 -(% style="color:blue" %)**AT Command: AT+ALARM1=min,max**
447 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image019.png||alt="说明: image-20220609151132-7.png"]]
457 457  
458 -(% style="color:#037691" %)**Example 1:**
449 +**~ 2.10 **Set trigger mode
459 459  
460 -AT+ ALARM1 =60,200  ~/~/ Alarm when moisture lower than 60.
451 +AT Command: **AT+TTRMOD**
461 461  
462 -AT+ ALARM2 =min,max
453 +Feature: Set the trigger interrupt mode.
463 463  
455 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image020.png||alt="说明: image-20220609151344-9.png"]]
464 464  
465 -(% style="color:#037691" %)**Example 2:**
457 +**2.11** Set the calculate flag
466 466  
467 -AT+ ALARM2 =200,1500  ~/~/ Alarm when temperature lower than 1500
459 +Feature: Set the calculate flag
468 468  
461 +**AT Command: AT+CALCFLAG**
469 469  
470 -== 2.8  Set the number of data to be uploaded and the recording time ==
463 +|**Command Example**|**Function**|**Response**
464 +|AT+CALCFLAG =1|Set the calculate flag to 1.|OK
465 +|AT+CALCFLAG =2|Set the calculate flag to 2.|OK
471 471  
467 +**2.12** Set count number
472 472  
473 -(% style="color:blue" %)**AT Command:**
469 +Feature: Manually set the count number
474 474  
475 -(% style="color:#037691" %)**AT+TR=900**(%%)  ~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
471 +**AT Command: AT+SETCNT**
476 476  
477 -(% style="color:#037691" %)**AT+NOUD=8**(%%)** ** ~/~/  The device uploads 0 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
473 +|**Command Example**|**Function**|**Response**
474 +|AT+ SETCNT =0|Set the count number to 0.|OK
475 +|AT+ SETCNT =100|Set the count number to 100.|OK
478 478  
479 479  
480 -== 2. Read or Clear cached data ==
478 +**2.13 Set the number of data to be uploaded and the recording time**
481 481  
480 +➢ AT Command:
482 482  
483 -(% style="color:blue" %)**AT Command:**
482 +AT+TR=900  ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
484 484  
485 -(% style="color:#037691" %)**AT+CDP**  (%%) ~/~/ Read cached data
486 486  
487 -(% style="color:#037691" %)**AT+CDP=0**  (%%) ~/~/ Clear cached data
485 +AT+NOUD=8  ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
488 488  
489 -[[image:1670408172929-569.png]]
487 +**2.14 Read or Clear cached data**
490 490  
489 +➢ AT Command:
491 491  
492 -== 2.10  ​Firmware Change Log ==
491 +AT+CDP    ~/~/ Read cached data
493 493  
493 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image021.png]]
494 494  
495 -Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0>>https://www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0]]
496 496  
497 -Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
496 +AT+CDP=0    ~/~/ Clear cached data ​
498 498  
498 +**2.15  ​Firmware Change Log**
499 499  
500 -== 2.11  ​Battery Analysis ==
500 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0>>url:https://www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0]]
501 501  
502 -=== 2.11.1  ​Battery Type ===
502 +Upgrade Instruction: [[Upgrade Firmware>>path:#H5.1200BHowtoUpgradeFirmware]]
503 503  
504 +**2.16  ​Battery Analysis**
504 504  
505 -The NMDS200 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
506 +**2.16.1  Battery Type**
506 506  
507 -The battery is designed to last for several years depends on the actual use environment and update interval. 
508 +The CPN01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
508 508  
509 -The battery-related documents as below:
510 +The battery is designed to last for several years depends on the actually use environment and update interval
510 510  
511 -* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
512 +The battery related documents as below:
512 512  
514 +* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
513 513  * [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
514 -
515 515  * [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
516 516  
517 -[[image:image-20221021111911-26.png]] ​
518 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image022.png||alt="说明: image-20220708140453-6.png"]] ​
518 518  
520 +**2.16.2  Power consumption Analyze**
519 519  
520 -=== 2.11.2  Power consumption Analyze ===
521 -
522 -
523 523  Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
524 524  
525 525  Instruction to use as below:
526 526  
527 -(% style="color:blue" %)**Step 1:  **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
526 +**Step 1:  **Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
528 528  
529 -(% style="color:blue" %)**Step 2: **(%%) Open it and choose
528 +**Step 2: ** Open it and choose
530 530  
531 531  * Product Model
532 -
533 533  * Uplink Interval
534 -
535 535  * Working Mode
536 536  
537 537  And the Life expectation in difference case will be shown on the right.
538 538  
539 -[[image:1666596205057-567.png]] ​
536 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image023.jpg||alt="说明: image-20220708141352-7.jpeg"]] ​
540 540  
538 +**2.16.3  ​Battery Note**
541 541  
542 -=== 2.11.3  ​Battery Note ===
543 -
544 -
545 545  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
546 546  
542 +**2.16.4  Replace the battery**
547 547  
548 -=== 2.11.4  Replace the battery ===
544 +The default battery pack of CPN01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
549 549  
546 +**3. ​ Access NB-IoT Module**
550 550  
551 -The default battery pack of NMDS200 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
552 -
553 -
554 -= 3. ​ Access NB-IoT Module =
555 -
556 -
557 557  Users can directly access the AT command set of the NB-IoT module.
558 558  
559 559  The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
560 560  
552 +[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image024.png||alt="说明: 1657261278785-153.png"]] ​
561 561  
562 -[[image:image-20221118094449-6.png]] ​
554 +**4.  Using the AT Commands**
563 563  
556 +**4.1  Access AT Commands**
564 564  
565 -= 4.  Using the AT Commands =
566 -
567 -== 4.1  Access AT Commands ==
568 -
569 -
570 570  See this link for detail:  [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
571 571  
572 572  AT+<CMD>?  : Help on <CMD>
... ... @@ -577,9 +577,8 @@
577 577  
578 578  AT+<CMD>=?  : Get the value
579 579  
568 +**General Commands**      
580 580  
581 -(% style="color:blue" %)**General Commands**      
582 -
583 583  AT  : Attention       
584 584  
585 585  AT?  : Short Help     
... ... @@ -602,97 +602,125 @@
602 602  
603 603  AT+SERVADDR  : Server Address
604 604  
605 -AT+TR      :  Get or Set record time
592 +AT+TR      : Get or Set record time"
606 606  
607 -AT+NOUD :  Get or Set the number of data to be uploaded
608 608  
609 -AT+CDP     :  Read or Clear cached data
595 +AT+NOUD      : Get or Set the number of data to be uploaded
610 610  
611 -AT+DEBUG:  Enable or Disable debug mode
612 612  
613 -AT+ALARM1:  Get or Set alarm of distance1
598 +AT+CDP     : Read or Clear cached data
614 614  
615 -AT+ALARM2:  Get or Set alarm of distance2
616 616  
617 -AT+GETSENSORVALUE :  Returns the current sensor measurement
601 +AT+ DEBUG   : Enable or Disable debug mode
618 618  
619 -AT+POWERIC :  Get or set the Power IC flag
603 +AT+ TTRIG   : Get or Set Alarm Base on Timeout
620 620  
605 +AT+ TTRMOD   : Get or Set the trigger interrupt mode(0:falling,1:rising)
621 621  
622 -(% style="color:blue" %)**COAP Management**      
607 +AT+ CALCFLAG   : Get or Set the calculate flag
623 623  
624 -AT+URI :  Resource parameters
609 +AT+ CLRC   : Clear current door open count
625 625  
611 +**COAP Management**      
626 626  
627 -(% style="color:blue" %)**UDP Management**
613 +AT+URI            : Resource parameters
628 628  
629 -AT+CFM :  Upload confirmation mode (only valid for UDP)
615 +**UDP Management**
630 630  
617 +AT+CFM          : Upload confirmation mode (only valid for UDP)
631 631  
632 -(% style="color:blue" %)**MQTT Management**
619 +**MQTT Management**
633 633  
634 -AT+CLIENT  : Get or Set MQTT client
621 +AT+CLIENT               : Get or Set MQTT client
635 635  
636 -AT+UNAME : Get or Set MQTT Username
623 +AT+UNAME  : Get or Set MQTT Username
637 637  
638 -AT+PWD  :  Get or Set MQTT password
625 +AT+PWD                  : Get or Set MQTT password
639 639  
640 -AT+PUBTOPIC :  Get or Set MQTT publish topic
627 +AT+PUBTOPIC  : Get or Set MQTT publish topic
641 641  
642 -AT+SUBTOPIC :  Get or Set MQTT subscription topic
629 +AT+SUBTOPIC  : Get or Set MQTT subscription topic
643 643  
631 +**Information**          
644 644  
645 -(% style="color:blue" %)**Information**          
633 +AT+FDR  : Factory Data Reset
646 646  
647 -AT+FDR :  Factory Data Reset
635 +AT+PWORD  : Serial Access Password
648 648  
649 -AT+PWORD :  Serial Access Password
637 +**​5.  FAQ**
650 650  
639 +**5.1 ​ How to Upgrade Firmware**
651 651  
652 -= ​5.  FAQ =
641 +User can upgrade the firmware for 1) bug fix, 2) new feature release.
653 653  
654 -== 5.1 How to Upgrade Firmware ==
643 +Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
655 655  
645 +**Notice, **CPN01 **and **CPN01 **share the same mother board. They use the same connection and method to update.**
656 656  
657 -User can upgrade the firmware for 1) bug fix, 2) new feature release.
647 +**5.2  Can I calibrate CPN01 to different soil types?**
658 658  
659 -Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
649 +CPN01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].
660 660  
661 -(% style="color:red" %)**Notice: **(% style="color:blue" %)**NMDS200** (%%)**and (% style="color:blue" %)LMDS200(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.**
651 +**6.  Trouble Shooting**
662 662  
653 +**6.1  ​Connection problem when uploading firmware**
663 663  
664 -= 6.  Trouble Shooting =
655 +**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
665 665  
666 -== 6.1  Connection problem when uploading firmware ==
657 +**6.2  AT Command input doesn't work**
667 667  
659 +In the case if user can see the console output but can't type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn't send **ENTER** while press the send key, user need to add ENTER in their string.
668 668  
669 -(% style="color:blue" %)**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
661 +**7. Order Info**
670 670  
663 +Part Number**:** CPN01
671 671  
672 -== 6.2  AT Command input doesn't work ==
665 +**8Packing Info**
673 673  
667 +**Package Includes**:
674 674  
675 -In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string.
669 +* CPN01 NB-IoT Soil Moisture & EC Sensor x 1
670 +* External antenna x 1
676 676  
672 +**Dimension and weight**:
677 677  
678 -= 7. ​ Order Info =
674 +* Size: 195 x 125 x 55 mm
675 +* Weight:   420g
679 679  
677 +**9.  Support**
680 680  
681 -Part Number:(% style="color:blue" %)** NMDS200**
679 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
680 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
682 682  
682 +​
683 683  
684 -= 8.  Packing Info =
685 685  
686 686  
687 -(% style="color:blue" %)**Package Includes**:
688 688  
689 -* NMDS200 NB-IoT Microwave Radar Distance Sensor x 1
690 690  
691 -= 9.  Support =
692 692  
693 693  
694 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
695 695  
696 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
697 697  
698 -​
692 +
693 +
694 +
695 +
696 +
697 +
698 +
699 +
700 +
701 +
702 +
703 +
704 +
705 +
706 +
707 +
708 +
709 +
710 +
711 +
712 +
713 +
1666596205057-567.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -179.8 KB
Content
1670404362039-351.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -492.6 KB
Content
1670405841875-916.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.1 KB
Content
1670405928926-116.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.7 KB
Content
1670406036256-101.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -181.0 KB
Content
1670406261143-723.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -77.9 KB
Content
1670407401682-959.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -23.7 KB
Content
1670408172929-569.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -211.8 KB
Content
LMDS200_10.jpg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -39.9 KB
Content
image-20221021112006-28.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.5 KB
Content
image-20221022234529-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -43.3 KB
Content
image-20221022234602-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -135.7 KB
Content
image-20221023000439-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -82.1 KB
Content
image-20221117105556-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -133.3 KB
Content
image-20221117114459-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -14.9 KB
Content
image-20221117114842-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -964.1 KB
Content
image-20221117114937-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -79.1 KB
Content
image-20221117114949-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -33.4 KB
Content
image-20221117115010-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -40.4 KB
Content
image-20221117142300-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -147.8 KB
Content
image-20221117145932-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -51.9 KB
Content
image-20221117150312-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -8.7 KB
Content
image-20221118092935-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -13.1 KB
Content
image-20221118093144-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -11.7 KB
Content
image-20221118093512-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -9.5 KB
Content
image-20221118093658-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -12.7 KB
Content
image-20221118094227-5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -29.2 KB
Content
image-20221118094449-6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.5 KB
Content
image-20221118103445-7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -20.4 KB
Content
image-20221118103453-8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -46.2 KB
Content
image-20221118103547-9.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -43.5 KB
Content
image-20221207170748-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -26.1 KB
Content
image-20221207170748-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -29.9 KB
Content
image-20221207173200-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -76.7 KB
Content
image-20221207173300-4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -77.0 KB
Content
image-20221208090742-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -79.7 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0