... ... @@ -458,23 +458,103 @@
458 458  == 2.7  Distance alarm function ==
459 459  
460 460  
461 -(% style="color:blue" %)**AT Command: AT+ALARM1=min,max**
461 +NDS03A can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
462 462  
463 -**Example 1:**
464 464  
465 -AT+ ALARM1 =60,200  ~/~/ Alarm when moisture lower than 60.
464 +(% style="color:blue" %)**1. Keep Status: Status to be monitor**
466 466  
467 -AT+ ALARM2 =min,max
466 +Keep Status = 1: Monitor Close to Open event
468 468  
468 +Keep Status = 0: Monitor Open to Close event
469 469  
470 -**Example 2:**
471 471  
472 -AT+ ALARM2 =200,1500  ~/~/ Alarm when temperature lower than 1500
471 +(% style="color:blue" %)**2. Keep Time: Timeout to send an Alarm**
473 473  
473 +Range 0 ~~ 65535(0xFFFF) seconds.
474 474  
475 -== 2.8  Set the number of data to be uploaded and the recording time ==
475 +If keep time = 0, Disable Alarm Base on Timeout feature.
476 476  
477 +If keep time > 0, device will monitor the keep status event and send an alarm when status doesn't change after timeout.
477 477  
479 +
480 +(% style="color:blue" %)**AT Command to configure:**
481 +
482 +(% style="color:blue" %)**PB14 PIN:**
483 +
484 +(% style="color:#037691" %)**AT+TTRIG=1,30** (%%) **~-~->**  When the **Keep Status** change from connected to disconnect, and device remains in disconnect status for more than 30 seconds. NDS03A will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
485 +
486 +(% style="color:#037691" %)**AT+TTRIG=0,0 ** (%%) **~-~->** Default Value, disable timeout Alarm.
487 +
488 +
489 +(% style="color:blue" %)**PB15 PIN:**
490 +
491 +(% style="color:#037691" %)**AT+TTRIG2=1,30**
492 +
493 +(% style="color:#037691" %)**AT+TTRIG2=0,0 **
494 +
495 +
496 +== 2.8  Set debug mode ==
497 +
498 +
499 +Feature: Enable or Disable debug mode
500 +
501 +(% style="color:blue" %)**AT Command: AT+DEBUG**
502 +
503 +[[image:image-20221021111629-21.png]]
504 +
505 +
506 +
507 +== 2.9  Clear Flash Record ==
508 +
509 +
510 +Feature: Clear flash storage for data log feature.
511 +
512 +(% style="color:blue" %)**AT Command: AT+CLRDTA**
513 +
514 +[[image:image-20221021111527-19.png]]
515 +
516 +
517 +== 2.10  Count Mod ==
518 +
519 +
520 +(% style="color:blue" %)**AT Command: AT+COUNTMOD**
521 +
522 +[[image:image-20221118092935-1.png]]
523 +
524 +
525 +== 2.11  Interrupt Pin Channel Mod ==
526 +
527 +
528 +(% style="color:blue" %)**AT Command: AT+TTRCHANNEL**
529 +
530 +[[image:image-20221118093144-2.png]]
531 +
532 +
533 +== 2.12 TTRIG1/2 timeout status alarm ==
534 +
535 +
536 +It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
537 +
538 +(% style="color:blue" %)**AT Command: AT+TTRALARM**
539 +
540 +[[image:image-20221118093512-3.png]]
541 +
542 +
543 +== 2.13  Select counting mode ==
544 +
545 +
546 +(% style="color:blue" %)**AT Command: AT+TTRMODx=a,b**
547 +
548 +When (% style="color:red" %)**a=0**(%%), the door is opened to count, and when (% style="color:red" %)**a=1**(%%),the closed door is counted.
549 +
550 +When (% style="color:red" %)**b=0**(%%), it is the last door open duration, and when (% style="color:red" %)**b=1**(%%),the last door close duration.
551 +
552 +[[image:image-20221118093658-4.png]]
553 +
554 +
555 +== 2.14  Set the number of data to be uploaded and the recording time ==
556 +
557 +
478 478  (% style="color:blue" %)**AT Command:**
479 479  
480 480  (% style="color:#037691" %)**AT+TR=900**(%%)  ~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
... ... @@ -482,7 +482,7 @@
482 482  (% style="color:#037691" %)**AT+NOUD=8**(%%)** ** ~/~/  The device uploads 0 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
483 483  
484 484  
485 -== 2.9  Read or Clear cached data ==
565 +== 2.15  Read or Clear cached data ==
486 486  
487 487  
488 488  (% style="color:blue" %)**AT Command:**
... ... @@ -491,10 +491,10 @@
491 491  
492 492  (% style="color:#037691" %)**AT+CDP=0**  (%%) ~/~/ Clear cached data ​
493 493  
494 -[[image:1670408172929-569.png]]
574 +[[image:image-20221118094227-5.png]]
495 495  
496 496  
497 -== 2.10  ​Firmware Change Log ==
577 +== 2.16  ​Firmware Change Log ==
498 498  
499 499  
500 500  Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0>>https://www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0]]
... ... @@ -502,12 +502,12 @@
502 502  Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
503 503  
504 504  
505 -== 2.11  ​Battery Analysis ==
585 +== 2.17  ​Battery Analysis ==
506 506  
507 -=== 2.11.1  ​Battery Type ===
587 +=== 2.17.1  ​Battery Type ===
508 508  
509 509  
510 -The NMDS200 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
590 +The NDS03A battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
511 511  
512 512  The battery is designed to last for several years depends on the actual use environment and update interval. 
513 513  
... ... @@ -522,7 +522,7 @@
522 522  [[image:image-20221021111911-26.png]] ​
523 523  
524 524  
525 -=== 2.11.2  Power consumption Analyze ===
605 +=== 2.17.2  Power consumption Analyze ===
526 526  
527 527  
528 528  Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -544,16 +544,16 @@
544 544  [[image:1666596205057-567.png]] ​
545 545  
546 546  
547 -=== 2.11.3  ​Battery Note ===
627 +=== 2.17.3  ​Battery Note ===
548 548  
549 549  
550 550  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
551 551  
552 552  
553 -=== 2.11.4  Replace the battery ===
633 +=== 2.17.4  Replace the battery ===
554 554  
555 555  
556 -The default battery pack of NMDS200 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
636 +The default battery pack of NDS03A includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
557 557  
558 558  
559 559  = 3. ​ Access NB-IoT Module =
1670408172929-569.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -211.8 KB
Content
image-20221208090742-1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -79.7 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0