... ... @@ -366,13 +366,13 @@
366 366  
367 367  Specify the software version: 0x64=100, which means firmware version 1.00.
368 368  
369 -For example 0x00 64 : This device is NMDS200 1 with firmware version 1.0.0.
369 +For example 0x00 64 : This device is NDS03A 1 with firmware version 1.0.0.
370 370  
371 371  
372 372  === 2.4.3  Battery Info ===
373 373  
374 374  
375 -Check the battery voltage for NMDS200.
375 +Check the battery voltage for NDS03A.
376 376  
377 377  Ex1: 0x0B45 = 2885mV
378 378  
... ... @@ -397,31 +397,34 @@
397 397  **99**    Not known or not detectable
398 398  
399 399  
400 -=== 2.4.5  Distance ===
400 +=== 2.4.5  Disalarm: (default: 0) ===
401 401  
402 402  
403 -[[image:1670407401682-959.png]]
403 +(% style="color:blue" %)**If Disalarm = 1**(%%), NDS03A will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse.
404 404  
405 -**(% style="color:blue" %)Object1 Distance:**
405 +(% style="color:blue" %)**If Disalarm = 0**(%%), NDS03A will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time.
406 406  
407 -Distance between sensor probe to the first object. (unit: cm)
407 + (% style="color:red" %)**Note:**(%%) When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast.
408 408  
409 -For example, if the data you get from the register is 0x02 0x05, the distance between the sensor and the measured object is
410 410  
411 -**(% style="color:blue" %)0205(H) = 517 (D) = 517 cm.**
410 +=== 2.4.6  Keep Status & Keep Time ===
412 412  
413 413  
414 -**(% style="color:blue" %)Object2 Distance:**
413 +Shows the configure value of Alarm Base on Timeout Feature
415 415  
416 -Distance between sensor probe to the second object. (unit: cm)
417 417  
416 +=== 2.4.7  Timestamp ===
418 418  
419 -=== 2.4.6  Timestamp ===
420 420  
421 -
422 422  Timestamp : 0x6315537b =1662342011
423 423  
424 424  
422 +=== 2.4.8  Switch Dual Channel Mode ===
423 +
424 +
425 +NDS03A can connect two door sensors. Another door sensor can be connected to PB15 pin. Both channels support alarm function.
426 +
427 +
425 425  == 2.5  Downlink Payload ==
426 426  
427 427  