Changes for page NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 17:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 5 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -140,23 +140,21 @@ 140 140 [[image:image-20221021110615-5.png]] 141 141 142 142 143 -== 2.2 Configure NDS0 3A==143 +== 2.2 Configure NMDS200 == 144 144 145 -=== 2.2.1 Test Requirement === 146 146 146 +To use NMDS200 in your city, make sure to meet below requirements: 147 147 148 -To use NDS03A in your city, make sure to meet below requirements: 149 - 150 150 * Your local operator has already distributed an NB-IoT Network. 151 -* The local NB-IoT network used the band that NDS0 3Asupports.149 +* The local NB-IoT network used the band that NMDS200 supports. 152 152 * Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 153 153 154 -Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NDS0 3Awill use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server.152 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NMDS200 will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server. 155 155 156 -[[image:image-20221 117142300-1.png]]154 +[[image:image-20221207173300-4.png]] 157 157 158 158 159 -=== 2.2. 2Insert NB-IoT SIM card ===157 +=== 2.2.1 Insert NB-IoT SIM card === 160 160 161 161 162 162 Insert the NB-IoT Card get from your provider. ... ... @@ -166,10 +166,10 @@ 166 166 [[image:image-20221021110745-6.png]] 167 167 168 168 169 -=== 2.2. 3Connect USB – TTL to NDS03Aand configure it ===167 +=== 2.2.2 Connect USB – TTL to NMDS200 and configure it === 170 170 171 171 172 -User need to configure NDS0 3Avia serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NDS03Asupport AT Commands, user can use a USB to TTL adapter to connect to NDS03Aand use AT Commands to configure it, as below.170 +User need to configure NMDS200 via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NMDS200 support AT Commands, user can use a USB to TTL adapter to connect to NMDS200 and use AT Commands to configure it, as below. 173 173 174 174 (% style="color:blue" %)**Connection:** 175 175 ... ... @@ -192,11 +192,11 @@ 192 192 193 193 * Flow Control: (% style="color:red" %)**None** 194 194 195 -Make sure the switch is in FLASH position, then power on NDS0 3Aby connecting the (% style="color:orange" %)**Yellow Jumper**(%%).193 +Make sure the switch is in FLASH position, then power on NMDS200 by connecting the (% style="color:orange" %)**Yellow Jumper**(%%). 196 196 197 197 [[image:image-20221021110817-7.png]] 198 198 199 -NDS0 3Awill output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input.197 +NMDS200 will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input. 200 200 201 201 202 202 (% style="color:red" %)**Note: the valid AT Commands can be found at: **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] ... ... @@ -203,7 +203,7 @@ 203 203 204 204 205 205 206 -=== 2.2. 4Use CoAP protocol to uplink data ===204 +=== 2.2.3 Use CoAP protocol to uplink data === 207 207 208 208 209 209 (% style="color:red" %)**Note: if you don't have a CoAP server, you can refer this link to set up a CoAP server: **(%%)[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] ... ... @@ -222,12 +222,12 @@ 222 222 [[image:image-20221021110948-8.png]] 223 223 224 224 225 -After configuring the server address and (% style="color:green" %)**reset NDS0 3A**(%%)3Awill start to uplink sensor values to the CoAP server.223 +After configuring the server address and (% style="color:green" %)**reset NMDS200**(%%) (via AT+ATZ ), NMDS200 will start to uplink sensor values to the CoAP server. 226 226 227 -[[image: image-20221118103547-9.png||height="605" width="837"]] 225 +[[image:1670405841875-916.png]] 228 228 229 229 230 -=== 2.2. 5Use UDP protocol to uplink data(Default protocol) ===228 +=== 2.2.4 Use UDP protocol to uplink data(Default protocol) === 231 231 232 232 233 233 (% style="color:blue" %)**AT Commands:** ... ... @@ -245,7 +245,7 @@ 245 245 246 246 247 247 248 -=== 2.2. 6Use MQTT protocol to uplink data ===246 +=== 2.2.5 Use MQTT protocol to uplink data === 249 249 250 250 251 251 (% style="color:blue" %)**AT Commands:** ... ... @@ -267,7 +267,7 @@ 267 267 [[image:image-20221118103445-7.png]] 268 268 269 269 270 -[[image: image-20221118103453-8.png||height="608" width="841"]]268 +[[image:1670405928926-116.png]] 271 271 272 272 273 273 ... ... @@ -274,7 +274,7 @@ 274 274 MQTT protocol has a much higher power consumption compare with UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 275 275 276 276 277 -=== 2.2. 7Use TCP protocol to uplink data ===275 +=== 2.2.6 Use TCP protocol to uplink data === 278 278 279 279 280 280 (% style="color:blue" %)**AT Commands:** ... ... @@ -283,18 +283,19 @@ 283 283 284 284 * (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5600 ** (%%) ~/~/ Set TCP server address and port 285 285 286 - [[image: image-20221021111125-14.png]]284 + [[image:1670406036256-101.png||height="676" width="713"]] 287 287 286 + 288 288 [[image:image-20221021111131-15.png]] 289 289 290 290 291 291 292 -=== 2.2. 8Change Update Interval ===291 +=== 2.2.7 Change Update Interval === 293 293 294 294 295 295 User can use below command to change the (% style="color:blue" %)**uplink interval**. 296 296 297 -* (% style="color:#037691" %)**AT+TDC= 14400 ** (%%) ~/~/ Set Update Interval to14400s (4 hours)296 +* (% style="color:#037691" %)**AT+TDC=7200 ** (%%) ~/~/ Set Update Interval to 7200s (4 hours) 298 298 299 299 (% style="color:red" %)**NOTE:** 300 300
- 1670405841875-916.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.1 KB - Content
- 1670405928926-116.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.7 KB - Content
- 1670406036256-101.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +181.0 KB - Content
- 1670406261143-723.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.9 KB - Content
- image-20221207173300-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.0 KB - Content