Changes for page NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 17:03
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -370,6 +370,7 @@ 370 370 ))) 371 371 |(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.10A0Timestamp"]]|(% style="width:115px" %)Door Status(pb14)|(% style="width:92px" %)door open num(pb14)|(% style="width:99px" %)last open time(pb14)|(% style="width:67px" %)Time stamp|(% style="width:74px" %)... 372 372 373 + 373 373 (% style="color:blue" %)**When AT+TTRCHANNEL=2:** 374 374 375 375 ... ... @@ -418,6 +418,7 @@ 418 418 419 419 * (% style="color:#037691" %)**Timestamp:**(%%) 0x637590df =1668649183 (Unix Time) 420 420 422 + 421 421 == 2.4 Payload Explanation and Sensor Interface == 422 422 423 423 ... ... @@ -435,18 +435,20 @@ 435 435 The Device ID is stored in a non-erase area, Upgrade the firmware or run AT+FDR won't erase the Device ID. 436 436 437 437 440 + 438 438 === 2.4.2 Version Info === 439 439 440 440 441 441 Specify the software version: 0x64=100, which means firmware version 1.00. 442 442 443 -For example 0x00 64 : This device is N DS03A1 with firmware version 1.0.0.446 +For example 0x00 64 : This device is CPN01 with firmware version 1.0.0. 444 444 445 445 449 + 446 446 === 2.4.3 Battery Info === 447 447 448 448 449 -Check the battery voltage for N DS03A.453 +Check the battery voltage for CPN01. 450 450 451 451 Ex1: 0x0B45 = 2885mV 452 452 ... ... @@ -453,6 +453,7 @@ 453 453 Ex2: 0x0B49 = 2889mV 454 454 455 455 460 + 456 456 === 2.4.4 Signal Strength === 457 457 458 458 ... ... @@ -471,39 +471,70 @@ 471 471 **99** Not known or not detectable 472 472 473 473 474 -=== 2.4.5 Disalarm: (default: 0) === 475 475 480 +=== 2.4.5 Calculate Flag === 476 476 477 -(% style="color:blue" %)**If Disalarm = 1**(%%), NDS03A will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse. 478 478 479 - (% style="color:blue"%)**IfDisalarm= 0**(%%), NDS03A willsenduplinkateveryTDC periodically andsenddataoneachopen/close event.This isuseful fortheapplicationuserneedtomonitor theopen/closeeventinreal-time.483 +The calculate flag is a user defined field, IoT server can use this filed to handle different meters with different pulse factors. For example, if there are 100 water meters, meter 1~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse. 480 480 481 - (%style="color:red" %)**Note:**(%%)When Disalarm=0,ahighfrequentlyopen/closeeventwillcauselotsofuplink anddrainbattery very fast.485 +User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation. 482 482 487 +Default value: 0. 483 483 484 - ===2.4.6Keep Status&KeepTime===489 +Range (6 bits): (b)000000 ~~ (b) 111111 485 485 486 486 487 -Shows the configure value of Alarm Base on Timeout Feature 488 488 493 +=== 2.4.6 Alarm === 489 489 490 -=== 2.4.7 Timestamp === 491 491 496 +See [[Alarm Base on Timeout>>||anchor="H2.7A0AlarmBaseonTimeout"]] 492 492 493 -Timestamp : 0x6315537b =1662342011 494 494 495 495 500 +=== 2.4.7 Contact Status === 496 496 497 -=== 2.4.8 Switch Dual Channel Mode === 498 498 503 +0: Open 499 499 500 - NDS03A can connect two door sensors. Another door sensor can be connected to PB15pin. Both channels support alarm function.505 +1: Close 501 501 502 502 508 + 509 +=== 2.4.8 Total pulse === 510 + 511 + 512 +Total pulse/counting based on dry [[contact trigger event>>||anchor="H2.12Setcountnumber"]] 513 + 514 +Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215 515 + 516 + 517 + 518 +=== 2.4.9 The last open duration === 519 + 520 + 521 +Dry Contact last open duration. 522 + 523 +Unit: min. 524 + 525 +[[image:image-20221021111346-17.png||height="146" width="770"]] 526 + 527 + 528 + 529 +=== 2.4.10 Timestamp === 530 + 531 + 532 +Timestamp : 0x6315537b =1662342011 533 + 534 +Convert Unix timestamp to time 2022-9-5 9:40:11. 535 + 536 +**~ ** 537 + 538 + 503 503 == 2.5 Downlink Payload == 504 504 505 505 506 -By default, N DS03Aprints the downlink payload to console port.542 +By default, CPN01 prints the downlink payload to console port. 507 507 508 508 [[image:image-20221021111414-18.png]] 509 509
- image-20221118092935-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -13.1 KB - Content
- image-20221118093144-2.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Xiaoling - Size
-
... ... @@ -1,1 +1,0 @@ 1 -11.7 KB - Content