<
From version < 58.2 >
edited by Xiaoling
on 2022/11/17 11:54
To version < 70.9 >
edited by Xiaoling
on 2022/11/18 11:03
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -9,13 +9,14 @@
9 9  
10 10  **Table of Contents:**
11 11  
12 +{{toc/}}
12 12  
13 13  
14 14  
15 15  
17 +
16 16  = 1.  Introduction =
17 17  
18 -
19 19  == 1.1 ​ What is NDS03A NB-IoT Open/Close Door Sensor ==
20 20  
21 21  
... ... @@ -73,7 +73,6 @@
73 73  
74 74  
75 75  
76 -
77 77  == 1.3  Storage & Operation ==
78 78  
79 79  
... ... @@ -93,9 +93,6 @@
93 93  
94 94  
95 95  
96 -
97 -
98 -
99 99  == 1.5 ​ Applications ==
100 100  
101 101  
... ... @@ -131,10 +131,9 @@
131 131  === 1.7.1  Pin Definition ===
132 132  
133 133  
134 -CPN01 is pre-configured to connect to two external wires. The other pins are not used. If user wants to know more about other pins, please refer to the **[[LSN50v2 User Manual>>doc:Main.User Manual for LoRaWAN End Nodes.LSN50 & LSN50-V2 - LoRaWAN Sensor Node User Manual.WebHome]]**.
131 +The device is pre-configured to connect to a door sensor. The other pins are not used. If user wants to know more about other pins, please refer to the user manual of LSN50v2 at:  [[https:~~/~~/www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0>>https://www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0]]
135 135  
136 136  
137 -
138 138  === 1.7.2  Jumper JP2(Power ON/OFF) ===
139 139  
140 140  
... ... @@ -141,7 +141,6 @@
141 141  Power on Device when putting this jumper.
142 142  
143 143  
144 -
145 145  === 1.7.3  BOOT MODE / SW1 ===
146 146  
147 147  
... ... @@ -150,7 +150,6 @@
150 150  2)  Flash:  working mode, the device starts to work for NB-IoT connection and sends out console output for further debugging.
151 151  
152 152  
153 -
154 154  === 1.7.4  Reset Button ===
155 155  
156 156  
... ... @@ -157,7 +157,6 @@
157 157  Press to reboot the device.
158 158  
159 159  
160 -
161 161  === 1.7.5  LED ===
162 162  
163 163  
... ... @@ -168,49 +168,42 @@
168 168  2.  Send an uplink packet
169 169  
170 170  
171 -
172 172  == 1.8  Magnet Distance ==
173 173  
174 174  
175 -**Wood Door:** 10 ~~ 30mm
167 +(% style="color:blue" %)**Wood Door:**(%%) 10 ~~ 30mm
176 176  
177 -**Iron Door:  **30 ~~ 45mm
169 +(% style="color:blue" %)**Iron Door:**(%%)**    **30 ~~ 45mm
178 178  
179 179  
172 += 2.  Use NDS03A to communicate with IoT Server =
180 180  
181 -= 2.  Use CPN01 to communicate with IoT Server =
182 -
183 -
184 184  == 2.1  How it works ==
185 185  
186 186  
187 -The CPN01 is equipped with an NB-IoT module, the pre-loaded firmware in CPN01 will get (% style="color:blue" %)**Open/Close Event or Count**(%%) from sensor and send the value to the NB-IoT network. The NB-IoT network will forward this value to IoT server via the protocol defined by CPN01.
177 +In this user case, the NDS03A is installed on the door edge to detect the open/close event and send the status to the NB-IoT server. The NB-IoT network will forward this value to IoT server via the protocol defined by NDS03A.
188 188  
189 -The diagram below shows the working flow in the default firmware of CPN01:
179 +The diagram below shows the working flow in the default firmware of NDS03A:
190 190  
191 191  [[image:image-20221021110615-5.png]]
192 192  
193 193  
184 +== 2.2 ​ Configure NDS03A ==
194 194  
195 -== 2.2 ​ Configure CPN01 ==
196 -
197 -
198 198  === 2.2.1 Test Requirement ===
199 199  
200 200  
201 -To use CPN01 in your city, make sure to meet below requirements:
189 +To use NDS03A in your city, make sure to meet below requirements:
202 202  
203 203  * Your local operator has already distributed an NB-IoT Network.
204 -* The local NB-IoT network used the band that CPN01 supports.
192 +* The local NB-IoT network used the band that NDS03A supports.
205 205  * Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
206 206  
207 -Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The CPN01 will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server.
195 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The NDS03A will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server.
208 208  
209 -[[image:image-20221023000439-3.png]]
197 +[[image:image-20221117142300-1.png]]
210 210  
211 - ​
212 212  
213 -
214 214  === 2.2.2 Insert NB-IoT SIM card ===
215 215  
216 216  
... ... @@ -221,12 +221,11 @@
221 221  [[image:image-20221021110745-6.png]] ​
222 222  
223 223  
210 +=== 2.2.3 Connect USB – TTL to NDS03A and configure it ===
224 224  
225 -=== 2.2.3 Connect USB – TTL to CPN01 and configure it ===
226 226  
213 +User need to configure NDS03A via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NDS03A support AT Commands, user can use a USB to TTL adapter to connect to NDS03A and use AT Commands to configure it, as below.
227 227  
228 -User need to configure CPN01 via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. CPN01 support AT Commands, user can use a USB to TTL adapter to connect to CPN01 and use AT Commands to configure it, as below.
229 -
230 230  (% style="color:blue" %)**Connection:**
231 231  
232 232  (% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND**
... ... @@ -248,11 +248,11 @@
248 248  
249 249  * Flow Control: (% style="color:red" %)**None**
250 250  
251 -Make sure the switch is in FLASH position, then power on CPN01 by connecting the (% style="color:orange" %)**Yellow Jumper**(%%).
236 +Make sure the switch is in FLASH position, then power on NDS03A by connecting the (% style="color:orange" %)**Yellow Jumper**(%%).
252 252  
253 253  ​[[image:image-20221021110817-7.png]]
254 254  
255 -CPN01 will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input.
240 +NDS03A will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input.
256 256  
257 257  
258 258  (% style="color:red" %)**Note: the valid AT Commands can be found at:  **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
... ... @@ -265,7 +265,7 @@
265 265  (% style="color:red" %)**Note: if you don't have a CoAP server, you can refer this link to set up a CoAP server: **(%%)[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
266 266  
267 267  
268 -(% style="color:blue" %)**Use below commands in CPN01:**
253 +(% style="color:blue" %)**Use below commands in NDS03A:**
269 269  
270 270  * (% style="color:#037691" %)**AT+PRO=1**                (%%) ~/~/ Set to use CoAP protocol to uplink
271 271  
... ... @@ -278,12 +278,11 @@
278 278  [[image:image-20221021110948-8.png]]
279 279  
280 280  
281 -After configuring the server address and (% style="color:green" %)**reset CPN01**(%%) (via AT+ATZ ), CPN01 will start to uplink sensor values to the CoAP server.
266 +After configuring the server address and (% style="color:green" %)**reset NDS03A**(%%) (via AT+ATZ ), NDS03A will start to uplink sensor values to the CoAP server.
282 282  
283 -[[image:image-20221021110956-9.png]] ​
268 +[[image:image-20221118103547-9.png||height="605" width="837"]] ​
284 284  
285 285  
286 -
287 287  === 2.2.5 Use UDP protocol to uplink data(Default protocol) ===
288 288  
289 289  
... ... @@ -302,7 +302,6 @@
302 302  
303 303  ​
304 304  
305 -
306 306  === 2.2.6 Use MQTT protocol to uplink data ===
307 307  
308 308  
... ... @@ -322,10 +322,10 @@
322 322  
323 323  * (% style="color:#037691" %)**AT+SUBTOPIC=NSE01_SUB          ** (%%) ~/~/  Set the subscription topic of MQTT
324 324  
325 -​ [[image:image-20221021111058-12.png]]
308 +​ [[image:image-20221118103445-7.png]]
326 326  
327 327  
328 -[[image:image-20221021111201-16.png||height="472" width="653"]]
311 +[[image:image-20221118103453-8.png||height="608" width="841"]]
329 329  
330 330  ​
331 331  
... ... @@ -332,7 +332,6 @@
332 332  MQTT protocol has a much higher power consumption compare with UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
333 333  
334 334  
335 -
336 336  === 2.2.7 Use TCP protocol to uplink data ===
337 337  
338 338  
... ... @@ -348,76 +348,91 @@
348 348  
349 349  ​
350 350  
351 -
352 352  === 2.2.8 Change Update Interval ===
353 353  
354 354  
355 355  User can use below command to change the (% style="color:blue" %)**uplink interval**.
356 356  
357 -* (% style="color:#037691" %)**AT+TDC=7200      ** (%%) ~/~/ Set Update Interval to 7200s (2 hours)
338 +* (% style="color:#037691" %)**AT+TDC=14400      ** (%%) ~/~/ Set Update Interval to 14400s (4 hours)
358 358  
359 359  (% style="color:red" %)**NOTE:**
360 360  
361 -1.  By default, the device will send an uplink message every 1 hour.
342 +1.  By default, the device will send an uplink message every 4 hour.
362 362  
363 363  
364 -
365 365  == 2.3  Uplink Payload ==
366 366  
367 367  
368 -The uplink payload includes 123 bytes in total by default.
348 +The uplink payload includes 26 bytes in total by default.
369 369  
370 -Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded.
350 +Each time the device uploads a data package. The user can use the AT+NOUD command to upload the recorded data.Up to 32 sets of recorded data can be uploaded.
371 371  
352 +(% style="color:blue" %)**When AT+TTRCHANNEL=1:**
372 372  
373 -(% border="1.5" style="background-color:#ffffcc; color:green; width:510px" %)
374 -|=(% scope="row" style="width: 60px;" %)**Size(bytes)**|(% style="width:40px" %)**8**|(% style="width:20px" %)**2**|(% style="width:20px" %)**2**|(% style="width:80px" %)**1**|(% style="width:40px" %)**1**|(% style="width:80px" %)**1**|(% style="width:80px" %)**1**|(% style="width:40px" %)**1**|(% style="width:60px" %)**3**
375 -|=(% style="width: 96px;" %)**Value**|(% style="width:84px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:44px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:121px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:52px" %)MOD|(% style="width:84px" %)[[ Calculate Flag>>||anchor="H2.4.5A0CalculateFlag"]]|(% style="width:116px" %)[[Contact Status>>||anchor="H2.4.7A0ContactStatus"]]|(% style="width:57px" %)[[Alarm>>||anchor="H2.4.6A0Alarm"]]|(% style="width:91px" %)[[Total pulse>>||anchor="H2.4.8A0Totalpulse"]]
354 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
355 +|=(% scope="row" style="width: 50px;" %)**Size(bytes)**|(% style="width:50px" %)**8**|(% style="width:20px" %)**2**|(% style="width:20px" %)**2**|(% style="width:65px" %)**1**|(% style="width:25px" %)**1**|(% style="width:50px" %)**1**|(% style="width:60px" %)**1**|(% style="width:90px" %)**3**|(% style="width:100px" %)**3**
356 +|=(% style="width: 93px;" %)**Value**|(% style="width:67px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:45px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:54px" %)MOD|(% style="width:62px" %)Door Status|(% style="width:60px" %)[[Alarm Status>>||anchor="H2.7A0AlarmBaseonTimeout"]]|(% style="width:94px" %)door open num(pb14) |(% style="width:93px" %)last open time(pb14)
376 376  
377 -(% border="1.5" style="background-color:#ffffcc; color:green; width:490px" %)
378 -|(% style="width:100px" %)**3**|(% style="width:50px" %)**4**|(% style="width:70px" %)**1**|(% style="width:50px" %)**3**|(% style="width:100px" %)**3**|(% style="width:80px" %)4|(% style="width:50px" %)**8 group**
379 -|(% style="width:176px" %)[[The last open duration>>||anchor="H2.4.9A0Thelastopenduration"]]|(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.10A0Timestamp"]]|(% style="width:115px" %)Contact Status|(% style="width:92px" %)Total pulse|(% style="width:169px" %)The last open duration|(% style="width:97px" %)Time stamp|(% style="width:74px" %)...
358 +(% border="1.5" style="background-color:#ffffcc; color:green; width:450px" %)
359 +|(% style="width:50px" %)**4**|(% style="width:90px" %)**1**|(% style="width:90px" %)**3**|(% style="width:90px" %)**3**|(% style="width:60px" %)4|(% style="width:50px" %)(((
360 +**1-32 group**
361 +)))
362 +|(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.7A0Timestamp"]]|(% style="width:115px" %)Door Status(pb14)|(% style="width:92px" %)door open num(pb14)|(% style="width:99px" %)last open time(pb14)|(% style="width:67px" %)Time stamp|(% style="width:74px" %)...
380 380  
381 -If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the CPN01 uplink data.
382 382  
383 -[[image:image-20221021111201-16.png||height="572" width="792"]]
384 384  
366 +(% style="color:blue" %)**When AT+TTRCHANNEL=2:**
385 385  
368 +
369 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
370 +|=(% scope="row" style="width: 50px;" %)**Size(bytes)**|(% style="width:50px" %)**8**|(% style="width:20px" %)**2**|(% style="width:20px" %)**2**|(% style="width:65px" %)**1**|(% style="width:25px" %)**1**|(% style="width:50px" %)**1**|(% style="width:60px" %)**1**|(% style="width:90px" %)**3**|(% style="width:100px" %)**3**
371 +|=(% style="width: 96px;" %)**Value**|(% style="width:66px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:70px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:54px" %)MOD|(% style="width:55px" %)Door Status(pb14)|(% style="width:57px" %)[[Alarm Status>>||anchor="H2.7A0AlarmBaseonTimeout"]](pb14)|(% style="width:86px" %)door open num(pb14) |(% style="width:82px" %)last open time(pb14)
372 +
373 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %)
374 +|(% style="width:59px" %)**1**|(% style="width:67px" %)**1**|(% style="width:88px" %)**3**|(% style="width:81px" %)**3**|(% style="width:50px" %)**4**|(% style="width:66px" %)**1**|(% style="width:92px" %)**3**
375 +|(% style="width:59px" %)Door Status(pb15)|(% style="width:67px" %)[[Alarm Status>>||anchor="H2.7A0AlarmBaseonTimeout"]](pb15)|(% style="width:88px" %)door open num(pb15)|(% style="width:81px" %)last open time(pb15)|(% style="width:50px" %)[[Time stamp>>||anchor="H2.4.7A0Timestamp"]]|(% style="width:66px" %)Door Status(pb14)|(% style="width:92px" %)door open num(pb14)
376 +
377 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:500px" %)
378 +|(% style="width:90px" %)**3**|(% style="width:80px" %)**1**|(% style="width:90px" %)**3**|(% style="width:70px" %)**3**|(% style="width:80px" %)**4**|(% style="width:80px" %)(((
379 +**1-32 group**
380 +)))
381 +|(% style="width:102px" %)last open time (pb14)|(% style="width:93px" %)Door Status(pb15)|(% style="width:91px" %)door open num(pb15)|(% style="width:88px" %)last open time(pb15)|(% style="width:63px" %)[[Time stamp>>||anchor="H2.4.7A0Timestamp"]]|(% style="width:87px" %)......
382 +
383 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NDS03A uplink data.
384 +
385 +[[image:image-20221117145932-2.png]]
386 +
387 +
386 386  The payload is ASCII string, representative same HEX:
387 387  
388 -**0x (% style="color:red" %)__f867787050213317__  (% style="color:blue" %)__0064__ (% style="color:green" %) __0c78__(% style="color:#00b0f0" %) __17__(% style="color:#7030a0" %) __01__(% style="color:#0020b0" %) __00__ (% style="color:#420042" %)__00__ (% style="color:#660066" %)__00__ (% style="color:#aaaa40" %)__000009__(% style="color:#663300" %) __000002__ (% style="color:#d60093" %)__6315537b__ (% style="color:#660066" %)__01 00000b 02 0000026 63510fed__ (%%)__0100000e0200000263510f39__ __010000000000000063510e85__ __010000000000000063510d2e__ __010000000000000063510c7a__ __010000000000000063510bc6__ __010000000000000063510954__ __010000000000000063510882 __**
390 +**0x (% style="color:red" %)__f867787050213317__  (% style="color:blue" %)__0064__ (% style="color:green" %) __0ccf__(% style="color:#00b0f0" %) __19__(% style="color:#7030a0" %) __01__(% style="color:#0020b0" %) __00__ (% style="color:#420042" %)__00__(% style="color:#660066" %) (% style="color:#aaaa40" %)__000016__(% style="color:#663300" %) __000017__ (% style="color:#d60093" %)__637590df__(%%)**
389 389  
390 390  **where:**
391 391  
392 392  * (% style="color:#037691" %)**Device ID:**(%%) 0x f867787050213317 = f867787050213317
393 393  
394 -* (% style="color:#037691" %)**Version:**(%%) 0x0064=100=1.0.0
396 +* (% style="color:#037691" %)**Version:**(%%)  0x0064=100=1.0.0
395 395  
396 -* (% style="color:#037691" %)**BAT :**(%%) 0x0c78 = 3192 mV = 3.192V
398 +* (% style="color:#037691" %)**BAT :**(%%)  0x0ccf = 3279 mV = 3.279V
397 397  
398 -* (% style="color:#037691" %)**Singal: **(%%)0x17 = 23
400 +* (% style="color:#037691" %)**Singal: **(%%)0x19 = 25
399 399  
400 -* (% style="color:#037691" %)**Mod:**(%%) 0x01 = 1
402 +* (% style="color:#037691" %)**Mod:**(%%)  0x01 = 1
401 401  
402 -* (% style="color:#037691" %)**Calculate Flag:**(%%) 0x00=0
404 +* (% style="color:#037691" %)**Door Status:**(%%)  0x00=0
403 403  
404 -* (% style="color:#037691" %)**Contact Status:**(%%) 0x00=0
406 +* (% style="color:#037691" %)**Alarm Status: **(%%)0x00 =0
405 405  
406 -* (% style="color:#037691" %)**Alarm: **(%%)0x00 =0
408 +* (% style="color:#037691" %)**door open num: **(%%)0x000016 =22
407 407  
408 -* (% style="color:#037691" %)**Total pulse: **(%%)0x000009 =9
410 +* (% style="color:#037691" %)**last open time:  **(%%)0x000017 =23
409 409  
410 -* (% style="color:#037691" %)**The last open duration: **(%%)0x000002 =2
412 +* (% style="color:#037691" %)**Timestamp:**(%%) 0x637590df =1668649183 (Unix Time)
411 411  
412 -* (% style="color:#037691" %)**Timestamp:**(%%) 0x6315537b =1662342011 (Unix Time)
413 413  
414 -* (% style="color:#037691" %)**Contact Status, Total pulse,The last open duration ,Time stamp :**(%%) 01  00000b  000026  63510fed
415 415  
416 -* (% style="color:#037691" %)**8 sets of recorded data: Contact Status, Total pulse, The last open duration ,Time stamp :**(%%) 0100000e00002663510f39,.......
417 -
418 418  == 2.4  Payload Explanation and Sensor Interface ==
419 419  
420 -
421 421  === 2.4.1  Device ID ===
422 422  
423 423  
... ... @@ -432,20 +432,18 @@
432 432  The Device ID is stored in a non-erase area, Upgrade the firmware or run AT+FDR won't erase the Device ID.
433 433  
434 434  
435 -
436 436  === 2.4.2  Version Info ===
437 437  
438 438  
439 439  Specify the software version: 0x64=100, which means firmware version 1.00.
440 440  
441 -For example 0x00 64 : This device is CPN01 with firmware version 1.0.0.
437 +For example 0x00 64 : This device is NDS03A 1 with firmware version 1.0.0.
442 442  
443 443  
444 -
445 445  === 2.4.3  Battery Info ===
446 446  
447 447  
448 -Check the battery voltage for CPN01.
443 +Check the battery voltage for NDS03A.
449 449  
450 450  Ex1: 0x0B45 = 2885mV
451 451  
... ... @@ -452,7 +452,6 @@
452 452  Ex2: 0x0B49 = 2889mV
453 453  
454 454  
455 -
456 456  === 2.4.4  Signal Strength ===
457 457  
458 458  
... ... @@ -471,70 +471,38 @@
471 471  **99**    Not known or not detectable
472 472  
473 473  
468 +=== 2.4.5  Disalarm: (default: 0) ===
474 474  
475 -=== 2.4.5  Calculate Flag ===
476 476  
471 +(% style="color:blue" %)**If Disalarm = 1**(%%), NDS03A will only send uplink at every TDC periodically. This is normally use for pulse meter application, in this application, there are many open/close event, and platform only care about the total number of pulse.
477 477  
478 -The calculate flag is a user defined field, IoT server can use this filed to handle different meters with different pulse factors. For example, if there are 100 water meters, meter 1~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse.
473 +(% style="color:blue" %)**If Disalarm = 0**(%%), NDS03A will send uplink at every TDC periodically and send data on each open/close event. This is useful for the application user need to monitor the open/close event in real-time.
479 479  
480 -User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation.
475 + (% style="color:red" %)**Note:**(%%) When Disalarm=0, a high frequently open/close event will cause lots of uplink and drain battery very fast.
481 481  
482 -Default value: 0. 
483 483  
484 -Range (6 bits): (b)000000 ~~ (b) 111111
478 +=== 2.4.6  Keep Status & Keep Time ===
485 485  
486 486  
481 +Shows the configure value of Alarm Base on Timeout Feature
487 487  
488 -=== 2.4.6  Alarm ===
489 489  
484 +=== 2.4.7  Timestamp ===
490 490  
491 -See [[Alarm Base on Timeout>>||anchor="H2.7A0AlarmBaseonTimeout"]]
492 492  
487 +Timestamp : 0x6315537b =1662342011
493 493  
494 494  
495 -=== 2.4.7  Contact Status ===
490 +=== 2.4.8  Switch Dual Channel Mode ===
496 496  
497 497  
498 -0: Open
493 +NDS03A can connect two door sensors. Another door sensor can be connected to PB15 pin. Both channels support alarm function.
499 499  
500 -1: Close
501 501  
502 -
503 -
504 -=== 2.4.8  Total pulse ===
505 -
506 -
507 -Total pulse/counting based on dry [[contact trigger event>>||anchor="H2.12Setcountnumber"]]
508 -
509 -Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215
510 -
511 -
512 -
513 -=== 2.4.9  The last open duration ===
514 -
515 -
516 -Dry Contact last open duration.
517 -
518 -Unit: min.
519 -
520 -[[image:image-20221021111346-17.png||height="146" width="770"]]
521 -
522 -
523 -
524 -=== 2.4.10  Timestamp ===
525 -
526 -
527 -Timestamp : 0x6315537b =1662342011
528 -
529 -Convert Unix timestamp to time 2022-9-5 9:40:11.
530 -
531 -**~ **
532 -
533 -
534 534  == 2.5  Downlink Payload ==
535 535  
536 536  
537 -By default, CPN01 prints the downlink payload to console port.
499 +By default, NDS03A prints the downlink payload to console port.
538 538  
539 539  [[image:image-20221021111414-18.png]] ​
540 540  
... ... @@ -551,7 +551,7 @@
551 551  
552 552  * (% style="color:#037691" %)**Reset**
553 553  
554 -If payload = 0x04FF, it will reset the NSE01
516 +If payload = 0x04FF, it will reset the NDS03A
555 555  
556 556  * (% style="color:#037691" %)**INTMOD**
557 557  
... ... @@ -558,20 +558,21 @@
558 558  Downlink Payload: 06000003, Set AT+INTMOD=3
559 559  
560 560  
561 -
562 562  == 2.6  ​LED Indicator ==
563 563  
564 564  
565 -The CPN01 has an internal LED which is to show the status of different states.
526 +The NDS03A has an internal LED which is to show the status of different states.
566 566  
567 567  * When the device starts normally, the LED will light up for 1 second.
568 -* After CPN01 join NB-IoT network. The LED will be ON for 3 seconds.
529 +* After NDS03A join NB-IoT network. The LED will be ON for 3 seconds.
569 569  * For each uplink probe, LED will be on for 500ms.
570 570  
532 +
533 +
571 571  == 2.7  Alarm Base on Timeout ==
572 572  
573 573  
574 -CPN01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
537 +NDS03A can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are:
575 575  
576 576  
577 577  (% style="color:blue" %)**1. Keep Status: Status to be monitor**
... ... @@ -587,17 +587,25 @@
587 587  
588 588  If keep time = 0, Disable Alarm Base on Timeout feature.
589 589  
590 -If keep time > 0, device will monitor the keep status event and send an alarm when status doesnt change after timeout.
553 +If keep time > 0, device will monitor the keep status event and send an alarm when status doesn't change after timeout.
591 591  
592 592  
593 593  (% style="color:blue" %)**AT Command to configure:**
594 594  
595 -(% style="color:#037691" %)**AT+TTRIG=1,30** (%%) **~-~->**  When the **Keep Status** change from connected to disconnect, and device remains in disconnect status for more than 30 seconds. CPN01 will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
558 +(% style="color:blue" %)**PB14 PIN:**
596 596  
560 +(% style="color:#037691" %)**AT+TTRIG=1,30** (%%) **~-~->**  When the **Keep Status** change from connected to disconnect, and device remains in disconnect status for more than 30 seconds. NDS03A will send an uplink packet, the [[Alarm bit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.
561 +
597 597  (% style="color:#037691" %)**AT+TTRIG=0,0 ** (%%) **~-~->** Default Value, disable timeout Alarm.
598 598  
599 599  
565 +(% style="color:blue" %)**PB15 PIN:**
600 600  
567 +(% style="color:#037691" %)**AT+TTRIG2=1,30**
568 +
569 +(% style="color:#037691" %)**AT+TTRIG2=0,0 **
570 +
571 +
601 601  == 2.8  Set debug mode ==
602 602  
603 603  
... ... @@ -619,54 +619,57 @@
619 619  [[image:image-20221021111527-19.png]]
620 620  
621 621  
593 +== 2.10  Count Mod ==
622 622  
623 -== 2.10  Set trigger mode ==
624 624  
596 +(% style="color:blue" %)**AT Command: AT+COUNTMOD**
625 625  
626 -(% style="color:blue" %)**AT Command: AT+TTRMOD**
598 +[[image:image-20221118092935-1.png]]
627 627  
628 -Feature: Set the trigger interrupt mode.
629 629  
630 -[[image:image-20221021111552-20.png]]
601 +== 2.11  Interrupt Pin Channel Mod ==
631 631  
632 632  
604 +(% style="color:blue" %)**AT Command: AT+TTRCHANNEL**
633 633  
634 -== 2.11  Set the calculate flag ==
606 +[[image:image-20221118093144-2.png]]
635 635  
636 636  
637 -Feature: Set the calculate flag
609 +== 2.12 TTRIG1/2 timeout status alarm ==
638 638  
639 -(% style="color:blue" %)**AT Command: AT+CALCFLAG**
640 640  
641 -[[image:image-20221021111711-22.png]]
612 +It needs to be used with AT+TTRIG1 or AT+TTRIG2. When TTRIG1 or TTRIG2 times out and causes an alarm, and the status does not change subsequently, an alarm packet will be sent at the alarm interval.
642 642  
614 +(% style="color:blue" %)**AT Command: AT+TTRALARM**
643 643  
616 +[[image:image-20221118093512-3.png]]
644 644  
645 -== 2.12 Set count number ==
646 646  
619 +== 2.13  Select counting mode ==
647 647  
648 -Feature: Manually set the count number
649 649  
650 -(% style="color:blue" %)**AT Command: AT+SETCNT**
622 +(% style="color:blue" %)**AT Command: AT+TTRMODx=a,b**
651 651  
652 -[[image:image-20221021111748-24.png]]
624 +When (% style="color:red" %)**a=0**(%%), the door is opened to count, and when (% style="color:red" %)**a=1**(%%),the closed door is counted.
653 653  
626 +When (% style="color:red" %)**b=0**(%%), it is the last door open duration, and when (% style="color:red" %)**b=1**(%%),the last door close duration.
654 654  
628 +[[image:image-20221118093658-4.png]]
655 655  
656 -== 2.13  Set the number of data to be uploaded and the recording time ==
657 657  
631 +== 2.14  Set the number of data to be uploaded and the recording time ==
658 658  
633 +
659 659  (% style="color:blue" %)**AT Command:**
660 660  
661 -(% style="color:#037691" %)**AT+TR=900**        (%%)~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
636 +(% style="color:#037691" %)**AT+TR=900**(%%)  ~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
662 662  
663 -(% style="color:#037691" %)**AT+NOUD=8 ** (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
638 +(% style="color:#037691" %)**AT+NOUD=8**(%%)** ** ~/~/  The device uploads 0 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
664 664  
665 665  
641 +== 2.15  Read or Clear cached data ==
666 666  
667 -== 2.14  Read or Clear cached data ==
668 668  
669 -
670 670  (% style="color:blue" %)**AT Command:**
671 671  
672 672  (% style="color:#037691" %)**AT+CDP**  (%%) ~/~/ Read cached data
... ... @@ -673,27 +673,24 @@
673 673  
674 674  (% style="color:#037691" %)**AT+CDP=0**  (%%) ~/~/ Clear cached data ​
675 675  
676 -[[image:image-20221021111810-25.png||height="364" width="797"]]
650 +[[image:image-20221118094227-5.png]]
677 677  
678 678  
653 +== 2.16  ​Firmware Change Log ==
679 679  
680 -== 2.15  ​Firmware Change Log ==
681 681  
656 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0>>https://www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0]]
682 682  
683 -Download URL & Firmware Change log:  [[https:~~/~~/www.dropbox.com/sh/8p5nuvo6gh7je4n/AAAMP7MMusgbXMz9Ik7Ls03Ga?dl=0>>https://www.dropbox.com/sh/8p5nuvo6gh7je4n/AAAMP7MMusgbXMz9Ik7Ls03Ga?dl=0]]
684 -
685 685  Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
686 686  
687 687  
661 +== 2.17  ​Battery Analysis ==
688 688  
689 -== 2.16  ​Battery Analysis ==
663 +=== 2.17.1  ​Battery Type ===
690 690  
691 691  
692 -=== 2.16.1  Battery Type ===
666 +The NDS03A battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
693 693  
694 -
695 -The CPN01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
696 -
697 697  The battery is designed to last for several years depends on the actual use environment and update interval. 
698 698  
699 699  The battery-related documents as below:
... ... @@ -707,10 +707,9 @@
707 707  [[image:image-20221021111911-26.png]] ​
708 708  
709 709  
681 +=== 2.17.2  Power consumption Analyze ===
710 710  
711 -=== 2.16.2  Power consumption Analyze ===
712 712  
713 -
714 714  Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
715 715  
716 716  Instruction to use as below:
... ... @@ -730,21 +730,18 @@
730 730  [[image:1666596205057-567.png]] ​
731 731  
732 732  
703 +=== 2.17.3  ​Battery Note ===
733 733  
734 -=== 2.16.3  ​Battery Note ===
735 735  
736 -
737 737  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
738 738  
739 739  
709 +=== 2.17.4  Replace the battery ===
740 740  
741 -=== 2.16.4  Replace the battery ===
742 742  
712 +The default battery pack of NDS03A includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
743 743  
744 -The default battery pack of CPN01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
745 745  
746 -
747 -
748 748  = 3. ​ Access NB-IoT Module =
749 749  
750 750  
... ... @@ -752,13 +752,11 @@
752 752  
753 753  The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
754 754  
755 -[[image:image-20221021112006-28.png]] ​
722 +[[image:image-20221118094449-6.png]] ​
756 756  
757 757  
758 -
759 759  = 4.  Using the AT Commands =
760 760  
761 -
762 762  == 4.1  Access AT Commands ==
763 763  
764 764  
... ... @@ -805,15 +805,21 @@
805 805  
806 806  AT+ DEBUG   : Enable or Disable debug mode
807 807  
808 -AT+ TTRIG   : Get or Set Alarm Base on Timeout
773 +AT+ TTRIG1   : Get or Set PB14 PIN Alarm Base on Timeout
809 809  
810 -AT+ TTRMOD   : Get or Set the trigger interrupt mode(0:falling,1:rising)
775 +AT+ TTRIG2   : Get or Set PB15 PIN Alarm Base on Timeout
811 811  
812 -AT+ CALCFLAG   : Get or Set the calculate flag
777 +AT+COUNTMOD  :  Get or Set the count mode
813 813  
814 -AT+ CLRC   : Clear current door open count
779 +AT+TTRCHANNEL  : Get or Set the number of interrupt channels
815 815  
781 +AT+TTRALARM : Get or Set TTRIG1 of Alarm interval (unit: minute)
816 816  
783 +AT+DISALARM  : Enable/Disable Alarm for door open/close or water leak event
784 +
785 +AT+ CLRC   :  Clear current door open count
786 +
787 +
817 817  (% style="color:blue" %)**COAP Management**      
818 818  
819 819  AT+URI            : Resource parameters
... ... @@ -844,10 +844,8 @@
844 844  AT+PWORD  : Serial Access Password
845 845  
846 846  
847 -
848 848  = ​5.  FAQ =
849 849  
850 -
851 851  == 5.1 ​ How to Upgrade Firmware ==
852 852  
853 853  
... ... @@ -855,13 +855,11 @@
855 855  
856 856  Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
857 857  
858 -(% style="color:red" %)**Notice: **(% style="color:blue" %)**CPN01** (%%)**and (% style="color:blue" %)CPL01(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.**
827 +(% style="color:red" %)**Notice: **(% style="color:blue" %)**NDS03A** (%%)**and (% style="color:blue" %)LDS03A(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.**
859 859  
860 860  
861 -
862 862  = 6.  Trouble Shooting =
863 863  
864 -
865 865  == 6.1  ​Connection problem when uploading firmware ==
866 866  
867 867  
... ... @@ -868,7 +868,6 @@
868 868  (% style="color:blue" %)**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
869 869  
870 870  
871 -
872 872  == 6.2  AT Command input doesn't work ==
873 873  
874 874  
... ... @@ -875,26 +875,20 @@
875 875  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string.
876 876  
877 877  
878 -
879 879  = 7. ​ Order Info =
880 880  
881 881  
882 -Part Number**:** CPN01
847 +Part Number**:** NDS03A
883 883  
884 884  
885 -
886 886  = 8.  Packing Info =
887 887  
888 888  
889 889  (% style="color:blue" %)**Package Includes**:
890 890  
891 -* CPN01 Open/Close Sensor x 1
892 -* External antenna x 1
855 +* NDS03A Open/Close Door Sensor x 1
893 893  
894 -(% style="color:blue" %)**Dimension and weight**:
895 895  
896 -* Size: 195 x 125 x 55 mm
897 -* Weight:   420g
898 898  
899 899  = 9.  Support =
900 900  
image-20221117142300-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +147.8 KB
Content
image-20221117145932-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +51.9 KB
Content
image-20221117150312-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +8.7 KB
Content
image-20221118092935-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +13.1 KB
Content
image-20221118093144-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +11.7 KB
Content
image-20221118093512-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +9.5 KB
Content
image-20221118093658-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +12.7 KB
Content
image-20221118094227-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +29.2 KB
Content
image-20221118094449-6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +76.5 KB
Content
image-20221118103445-7.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +20.4 KB
Content
image-20221118103453-8.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +46.2 KB
Content
image-20221118103547-9.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +43.5 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0