Changes for page NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 17:03
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 36 added, 0 removed)
- 1666596205057-567.png
- 1670404362039-351.png
- 1670405841875-916.png
- 1670405928926-116.png
- 1670406036256-101.png
- 1670406261143-723.png
- 1670407401682-959.png
- 1670408172929-569.png
- 1670471530120-960.png
- 1670471559211-638.png
- 1670471584490-640.png
- 1670471613823-833.png
- LMDS200_10.jpg
- image-20221117105556-1.png
- image-20221117114459-2.png
- image-20221117114842-3.png
- image-20221117114937-4.png
- image-20221117114949-5.png
- image-20221117115010-6.png
- image-20221117142300-1.png
- image-20221117145932-2.png
- image-20221117150312-3.png
- image-20221118092935-1.png
- image-20221118093144-2.png
- image-20221118093512-3.png
- image-20221118093658-4.png
- image-20221118094227-5.png
- image-20221118094449-6.png
- image-20221118103445-7.png
- image-20221118103453-8.png
- image-20221118103547-9.png
- image-20221207170748-1.png
- image-20221207170748-2.png
- image-20221207173200-3.png
- image-20221207173300-4.png
- image-20221208090742-1.png
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - CPN01- NB-IoTOutdoorOpen/CloseDryContactSensor User Manual1 +NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -1,34 +1,59 @@ 1 1 (% style="text-align:center" %) 2 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652856952171-363.png?rev=1.1||alt="1652856952171-363.png" height="578" width="588"]]2 +[[image:LMDS200_10.jpg]] 3 3 4 + 5 +**Table of Contents:** 6 + 4 4 {{toc/}} 5 5 6 -= **1. Introduction** = 7 7 8 -== **1.1 **What is CPN01 **NB-IoT** Pulse/Contact Sensor == 9 9 10 -The Dragino CPN01 is an (% style="color:blue" %)**NB-IoT Dry Contact Sensor**(%%). It detects open/close status and uplinks the info to IoT server via NB-IoT network. User can see the (% style="color:blue" %)**dry contact status, open time, and open counts**(%%) in the IoT Server. 11 11 12 - TheCPN01will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculates the last open duration. Users can alsodisable theuplink for each Open/Close event,instead, device can counteach open event and uplink periodically.12 += 1. Introduction = 13 13 14 - CPN01 has** (% style="color:blue"%)Open-Alarmfeature(%%)**,user can setthisfeature so CPN01willsendanalarmifthe contact has beenopenexceedsa certaintime.14 +== 1.1 What is NMDS200 NB-IoT Microwave Radar Distance Sensor == 15 15 16 -CPN01 is designed for outdoor use. It has a weatherproof enclosure and industrial-level battery to work in low to high temperatures. 17 17 18 -NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity, and spectrum efficiency, especially in deep coverage. 19 -\\CPN01 supports different uplink methods including (% style="color:blue" %)**TCP, MQTT, UDP, and CoAP**(%%) for different application requirements. 20 -\\CPN01 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long-term use of up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 21 -\\To use CPN01, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that CPN01 supports. If local operator support it, user needs to get a (% style="color:blue" %)**NB-IoT SIM card**(%%) from the operator and install into CPN01 to get NB-IoT network connection. 17 +((( 18 +The Dragino NMDS200 is a(% style="color:blue" %)** NB-IoT Microwave Radar distance sensor**(%%). It uses (% style="color:blue" %)**24Ghz Microwave**(%%) to detect the distance between sensor and different objects. Compare vs ultrasonic or Lidar measurement method, Microwave Radar is (% style="color:blue" %)**more reliable for condensation / dusty environment**(%%). It can sense correct distance even there is water or thick dust on top of the sensor. 19 +))) 22 22 23 - 21 +((( 22 +The NMDS200 can be applied to scenarios such as horizontal distance measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, etc. 23 +))) 24 24 25 -== **1.2 Features** == 25 +((( 26 +NMDS200 can (% style="color:blue" %)**measure two distances**(%%): the closest object and next object behind the closest one. 27 +))) 26 26 29 +((( 30 +NMDS200 (% style="color:blue" %)**supports Alarm Feature**(%%), user can set the NMDS200 to uplink data in a short interval when the distance is out of configured range. 31 +))) 32 + 33 +((( 34 +NarrowBand-Internet of Things (NB-IoT) is a (% style="color:blue" %)**standards-based low power wide area (LPWA) technology**(%%) developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity, and spectrum efficiency, especially in deep coverage. 35 +))) 36 + 37 +((( 38 +NMDS200 (% style="color:blue" %)**supports different uplink**(%%) methods including (% style="color:blue" %)**TCP, MQTT, UDP, and CoAP**(%%) for different application requirements. 39 +))) 40 + 41 +((( 42 +NMDS200 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**,(%%) It is designed for long-term use of up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 43 +))) 44 + 45 +((( 46 +To use NMDS200, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that NMDS200 supports. If local operator support it, user needs to get a** (% style="color:blue" %)NB-IoT SIM card(%%)** from the operator and install into NMDS200 to get NB-IoT network connection. 47 +))) 48 + 49 + 50 +== 1.2 Features == 51 + 52 + 27 27 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD 28 -* Open/Close detect 29 -* Open/Close statistics 54 +* Short uplink interval for Distance Alarm 30 30 * Monitor Battery Level 31 -* Uplink on periodicallyand open/close event56 +* Microwave Radar for distance detection 32 32 * Datalog feature 33 33 * Uplink periodically 34 34 * Downlink to change configure ... ... @@ -39,106 +39,110 @@ 39 39 * Micro SIM card slot for NB-IoT SIM 40 40 * 8500mAh Battery for long-term use 41 41 42 -== **1.3 Specification** == 43 43 44 -**Common DC Characteristics:** 45 45 46 -* Supply Voltage: 2.1v ~~ 3.6v 47 -* Operating Temperature: -40 ~~ 85°C 69 +== 1.3 Radar probe specification == 48 48 49 -**NB-IoT Spec:** 50 50 51 -* - B1 @H-FDD: 2100MHz 52 -* - B3 @H-FDD: 1800MHz 53 -* - B8 @H-FDD: 900MHz 54 -* - B5 @H-FDD: 850MHz 55 -* - B20 @H-FDD: 800MHz 56 -* - B28 @H-FDD: 700MHz 72 +* Measuring Method: FMCW 73 +* Frequency: 24.000 ~~ 24.500 GHz 74 +* Measurement output power: 6dBm 75 +* Measure range: 0.5 ~~ 20m 76 +* Accuracy: ±0.1m 77 +* Resolution: 0.01m 78 +* Horizontal Angel: 78° 79 +* Vertical Angel: 23° 57 57 58 -== **1.4 Installation** == 59 59 60 -Connect CPN01 to an Open Close sensor like below. So it can detect the Open/Close event. 61 61 62 - [[image:image-20221021110329-1.png]]83 +== 1.4 Storage Temperature == 63 63 64 -[[image:image-20221022234602-2.png||height="288" width="922"]] 65 65 86 + -40°C to +85°C 66 66 67 -== **1.5 Applications** == 68 68 69 -* Open/Close Detection 70 -* Pulse meter application 71 -* Dry Contact Detection 89 +== 1.5 Applications == 72 72 73 -== **1.6 Mechanical** == 74 74 75 -[[image:image-20221021110415-3.png]] 92 +* Horizontal distance measurement 93 +* Liquid level measurement 94 +* Parking management system 95 +* Object proximity and presence detection 96 +* Intelligent trash can management system 97 +* Robot obstacle avoidance 98 +* Automatic control 99 +* Sewer 100 +* Bottom water level monitoring 76 76 77 -== ** 1.7 Pin Definitions and Switch** == 78 78 79 -[[image:image-20221021110429-4.png]] 80 80 81 -== =**1.7.1PinDefinition**===104 +== 1.6 Specification == 82 82 83 -CPN01 is pre-configured to connect to two external wires. The other pins are not used. If user wants to know more about other pins, please refer to the **[[LSN50v2 User Manual>>doc:Main.User Manual for LoRaWAN End Nodes.LSN50 & LSN50-V2 - LoRaWAN Sensor Node User Manual.WebHome]]**. 84 84 107 +(% style="color:blue" %)**Common DC Characteristics:** 85 85 86 -=== **1.7.2 Jumper JP2(Power ON/OFF)** === 109 +* Supply Voltage: 2.1v ~~ 3.6v 110 +* Operating Temperature: 0 ~~ 70°C 87 87 88 - Poweron Devicewhenputting this jumper.112 +(% style="color:blue" %)**NB-IoT Spec:** 89 89 114 +* B1 @H-FDD: 2100MHz 115 +* B3 @H-FDD: 1800MHz 116 +* B8 @H-FDD: 900MHz 117 +* B5 @H-FDD: 850MHz 118 +* B20 @H-FDD: 800MHz 119 +* B28 @H-FDD: 700MHz 90 90 91 -=== **1.7.3 BOOT MODE / SW1** === 92 92 93 93 94 -1 )ISP: upgrade mode, device won'thave any signalin this mode. but ready for upgrade firmware. LED won'twork. The firmware won'trun.123 +== 1.7 Installation == 95 95 96 -2) Flash: working mode, the device starts to work for NB-IoT connection and sends out console output for further debugging. 97 97 126 +Sensor measure direction and angle is as below. When install the sensor, please make sure the sensor direct to object. 98 98 99 -=== **1.7.4 Reset Button** === 100 100 129 +[[image:image-20221207170748-1.png]] 101 101 102 -Press to reboot the device. 103 103 132 + [[image:image-20221207170748-2.png||height="345" width="634"]] 104 104 105 -=== **1.7.5 LED** === 106 106 107 107 108 - TheLEDwillblinkwhen:136 +== 1.8 Pin Definitions and Switch == 109 109 110 -1. Boot the device in flash mode 111 -1. Send an uplink packet 112 112 113 - = **2. UseCPN01to communicate with IoT Server** =139 +[[image:1670404362039-351.png]] 114 114 115 -== **2.1 How it works** == 116 116 117 - TheCPN01isquippedwith anNB-IoT module, the pre-loaded firmware in CPN01will get**Open/CloseEventor Count** from sensorand sendthevalue to the NB-IoT network. The NB-IoT network will forwardthisvalue toIoTservervia the protocol defined by CPN01.142 += 2. Use NMDS200 to communicate with IoT Server = 118 118 119 - Thediagrambelowshowstheworkingflow in the default firmware of CPN01:144 +== 2.1 How it works == 120 120 121 -[[image:image-20221021110615-5.png]] 122 122 147 +The NB-IoT network will forward this value to IoT server via the protocol defined by NMDS200. 123 123 124 - ==**2.2ConfigureCPN01** ==149 +The diagram below shows the working flow in the default firmware of NMDS200: 125 125 126 - === **2.2.1TestRequirement**===151 +[[image:image-20221021110615-5.png||height="996" width="492"]] 127 127 128 -To use CPN01 in your city, make sure to meet below requirements: 129 129 154 +== 2.2 Configure NMDS200 == 155 + 156 + 157 +To use NMDS200 in your city, make sure to meet below requirements: 158 + 130 130 * Your local operator has already distributed an NB-IoT Network. 131 -* The local NB-IoT network used the band that CPN01supports.160 +* The local NB-IoT network used the band that NMDS200 supports. 132 132 * Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 133 133 134 -Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The CPN01will use CoAP(120.24.4.116:5683) or raw UDP(120.24.4.116:5601) or MQTT(120.24.4.116:1883)or TCP(120.24.4.116:5600)protocol to send data to the test server.163 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NMDS200 will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server. 135 135 136 -[[image:image-20221 023000439-3.png]]165 +[[image:image-20221208090742-1.png]] 137 137 138 - 139 139 140 -=== **2.2.2Insert NB-IoT SIM card**===168 +=== 2.2.1 Insert NB-IoT SIM card === 141 141 170 + 142 142 Insert the NB-IoT Card get from your provider. 143 143 144 144 User needs to take out the NB-IoT module and insert the SIM card like below: ... ... @@ -146,445 +146,423 @@ 146 146 [[image:image-20221021110745-6.png]] 147 147 148 148 149 -=== **2.2.3Connect USB – TTL toCPN01and configure it**===178 +=== 2.2.2 Connect USB – TTL to NMDS200 and configure it === 150 150 151 -User need to configure CPN01 via serial port to set the **Server Address** / **Uplink Topic** to define where and how-to uplink packets. CPN01 support AT Commands, user can use a USB to TTL adapter to connect to CPN01 and use AT Commands to configure it, as below. 152 152 153 -**Connect ion:**181 +User need to configure NMDS200 via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NMDS200 support AT Commands, user can use a USB to TTL adapter to connect to NMDS200 and use AT Commands to configure it, as below. 154 154 155 - USBTTL GND <~-~-~-~-> GND183 +(% style="color:blue" %)**Connection:** 156 156 157 - USB TTL TXD <~-~-~-~->UART_RXD185 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 158 158 159 - USB TTL RXD <~-~-~-~-> UART_TXD187 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 160 160 161 - InthePC,usebelowserialtoolsettings:189 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 162 162 163 -* Baud: **9600** 164 -* Data bits:** 8** 165 -* Stop bits: **1** 166 -* Parity: **None** 167 -* Flow Control: **None** 168 168 169 - Makesuretheswitch is in FLASH position,thenpower on CPN01 by connectingthe (%style="color:orange" %)**Yellow Jumper**(%%).192 +In the PC, use below serial tool settings: 170 170 171 - [[image:image-20221021110817-7.png]]194 +* Baud: (% style="color:red" %)**9600** 172 172 173 - CPN01willoutputsystem info once powered on as below, we can enterthe **password:12345678**to access AT Command input.196 +* Data bits:** (% style="color:red" %)8(%%)** 174 174 198 +* Stop bits: (% style="color:red" %)**1** 175 175 176 -* *Note:the validATCommandscanbefoundat: **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]200 +* Parity: (% style="color:red" %)**None** 177 177 202 +* Flow Control: (% style="color:red" %)**None** 178 178 179 - ===**2.2.4UseCoAPprotocoltouplinkdata**===204 +Make sure the switch is in FLASH position, then power on NMDS200 by connecting the (% style="color:orange" %)**Yellow Jumper**(%%). 180 180 181 - **Note: if you don't have a CoAP server, you can refer this link to set up a CoAP server: **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]206 +[[image:image-20221021110817-7.png]] 182 182 208 +NMDS200 will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input. 183 183 184 -**Use below commands in CPN01:** 185 185 186 -* **AT+PRO=1** ~/~/ Set to use CoAP protocol to uplink 187 -* **AT+SERVADDR=120.24.4.116,5683 ** ~/~/ Set CoAP server address and port 188 -* **AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** ~/~/Set CoAP resource path 211 +(% style="color:red" %)**Note: the valid AT Commands can be found at: **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 189 189 190 -For parameter description, please refer to AT command set 191 191 192 - [[image:image-20221021110948-8.png]]214 +=== 2.2.3 Use CoAP protocol to uplink data === 193 193 194 194 195 - Afterconfiguringthe server addressand**resetCPN01**(viaAT+ATZ ),CPN01willstartto uplinksensoraluestotheserver.217 +(% style="color:red" %)**Note: if you don't have a CoAP server, you can refer this link to set up a CoAP server: **(%%)[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 196 196 197 -[[image:image-20221021110956-9.png]] 198 198 220 +(% style="color:blue" %)**Use below commands in NMDS200:** 199 199 200 -= ==**2.2.5UseUDP protocol to uplinkdata(Default protocol)** ===222 +* (% style="color:#037691" %)**AT+PRO=1** (%%) ~/~/ Set to use CoAP protocol to uplink 201 201 224 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5683 ** (%%) ~/~/ Set CoAP server address and port 202 202 203 -**AT Co mmands:**226 +* (% style="color:#037691" %)**AT+URI=0,0,11,2,"mqtt" ** (%%) ~/~/ Set CoAP resource path 204 204 205 -* **AT+PRO=2 ** ~/~/ Set to use UDP protocol to uplink 206 -* **AT+SERVADDR=120.24.4.116,5601 ** ~/~/ Set UDP server address and port 207 -* **AT+CFM=1 ** ~/~/If the server does not respond, this command is unnecessary 228 +For parameter description, please refer to AT command set 208 208 209 - [[image:image-20221021111025-10.png]]230 +[[image:1670471530120-960.png||height="647" width="674"]] 210 210 211 -[[image:image-20221021111033-11.png||height="241" width="576"]] 212 212 213 - 233 +After configuring the server address and (% style="color:green" %)**reset NMDS200**(%%) (via AT+ATZ ), NMDS200 will start to uplink sensor values to the CoAP server. 214 214 215 - === **2.2.6 UseMQTTprotocol to uplinkdata** ===235 +[[image:1670405841875-916.png]] 216 216 217 217 218 - **ATCommands:**238 +=== 2.2.4 Use UDP protocol to uplink data(Default protocol) === 219 219 220 -* **AT+PRO=3 ** ~/~/Set to use MQTT protocol to uplink 221 -* **AT+SERVADDR=120.24.4.116,1883 ** ~/~/Set MQTT server address and port 222 -* **AT+CLIENT=CLIENT ** ~/~/Set up the CLIENT of MQTT 223 -* **AT+UNAME=UNAME **~/~/Set the username of MQTT 224 -* **AT+PWD=PWD **~/~/Set the password of MQTT 225 -* **AT+PUBTOPIC=NSE01_PUB **~/~/Set the sending topic of MQTT 226 -* **AT+SUBTOPIC=NSE01_SUB ** ~/~/Set the subscription topic of MQTT 227 227 228 - [[image:image-20221021111058-12.png]]241 +(% style="color:blue" %)**AT Commands:** 229 229 230 - [[image:image-20221021111108-13.png]]243 +* (% style="color:#037691" %)**AT+PRO=2 ** (%%) ~/~/ Set to use UDP protocol to uplink 231 231 232 - 245 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5601 ** (%%) ~/~/ Set UDP server address and port 233 233 234 - MQTTprotocolhasa much higher powerconsumption comparewithUDP/CoAPprotocol.Pleasecheckthepoweranalyze documentandadjustthe uplinkperiodto a suitableinterval.247 +* (% style="color:#037691" %)**AT+CFM=1 ** (%%) ~/~/ If the server does not respond, this command is unnecessary 235 235 249 + [[image:1670471559211-638.png]] 236 236 237 -=== **2.2.7 Use TCP protocol to uplink data** === 238 238 239 - **AT Commands**252 +[[image:image-20221021111033-11.png||height="241" width="576"]] 240 240 241 -* **AT+PRO=4 ** ~/~/ Set to use TCP protocol to uplink 242 -* **AT+SERVADDR=120.24.4.116,5600 ** ~/~/ Set TCP server address and port 254 + 243 243 244 - [[image:image-20221021111125-14.png]]256 +=== 2.2.5 Use MQTT protocol to uplink data === 245 245 246 -[[image:image-20221021111131-15.png]] 247 247 248 - 259 +(% style="color:blue" %)**AT Commands:** 249 249 250 -== =**2.2.8ChangeUpdateInterval**===261 +* (% style="color:#037691" %)**AT+PRO=3 ** (%%) ~/~/ Set to use MQTT protocol to uplink 251 251 252 - Usercanuse belowcommand tochangethe**uplinkinterval**.263 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,1883 ** (%%) ~/~/ Set MQTT server address and port 253 253 254 -* **AT+ TDC=7200** ~/~/ SetUpdate Intervalto7200s (2 hours)265 +* (% style="color:#037691" %)**AT+CLIENT=CLIENT ** (%%) ~/~/ Set up the CLIENT of MQTT 255 255 256 -** NOTE:**267 +* (% style="color:#037691" %)**AT+UNAME=UNAME **(%%)** **~/~/ Set the username of MQTT 257 257 258 -* *~1.Bydefault,thedevicewillsendanuplinkmessageevery1hour.**269 +* (% style="color:#037691" %)**AT+PWD=PWD **(%%)** **~/~/ Set the password of MQTT 259 259 271 +* (% style="color:#037691" %)**AT+PUBTOPIC=NSE01_PUB **(%%)** **~/~/ Set the sending topic of MQTT 260 260 261 -== ** 2.3UplinkPayload**==273 +* (% style="color:#037691" %)**AT+SUBTOPIC=NSE01_SUB ** (%%) ~/~/ Set the subscription topic of MQTT 262 262 263 - Theuplink payload includes 87bytes in total by default.275 + [[image:1670471584490-640.png]] 264 264 265 -Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 266 266 267 -|**Size(bytes)**|**8**|**2**|**2**|**1**|**1**|**1**|**2**|**2**|4 268 -|**Value**|[[Device ID>>path:#H2.4.1A0A0DeviceID]]|[[Ver>>path:#H2.4.2A0VersionInfo]]|[[BAT>>path:#H2.4.3A0BatteryInfo]]|[[Signal Strength>>path:#H2.4.4A0SignalStrength]]|MOD|[[Interrupt>>path:#H2.4.8A0DigitalInterrupt]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|Time stamp 278 +[[image:1670405928926-116.png]] 269 269 270 -|2|2|4|8 group 271 -|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|Time stamp|... 280 + 272 272 273 - If we use theMQTT clientto subscribe to thisMQTTtopic,wecansee thefollowinginformationwhen theCPN01uplink data.282 +MQTT protocol has a much higher power consumption compare with UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 274 274 275 -[[image:image-20221021111201-16.png||height="572" width="792"]] 276 276 277 - ThepayloadisASCIIstring, representativesameHEX:285 +=== 2.2.6 Use TCP protocol to uplink data === 278 278 279 -**0x (% style="color:red" %)__0xf867787050213317__ (% style="color:blue" %)__0064__ (% style="color:green" %)_0c78__ __(% style="color:#00b0f0" %)17__ __(% style="color:#7030a0" %)01__ __(% style="color:#d60093" %)00__ __(% style="color:#a14d07" %)01 __ __(% style="color:#0020b0" %)__ __00__ __(% style="color:#420042" %)000009__ __(% style="color:#663300" %) 000002__ __(% style="color:#d60093" %)6315537bb__ __(% style="color:#663300" %)// 0100000b02000002663510fed__ __0100000e0200000263510f39 010000000000000063510e85 010000000000000063510d2e 010000000000000063510c7a 010000000000000063510bc6 010000000000000063510954 010000000000000063510882 //(%%)** 280 280 281 -where: 282 -*(% style="color:#037691" %) **Device ID:**(%%) 0x f867787050213317 = f867787050213317 288 +(% style="color:blue" %)**AT Commands:** 283 283 284 -*(% style="color:#037691" %) Version:**(%%)0x0064=100=1.0.0290 +* (% style="color:#037691" %)**AT+PRO=4 ** (%%) ~/~/ Set to use TCP protocol to uplink 285 285 286 -*(% style="color:#037691" %) BAT:**(%%)0x0c78=3192mV=3.192V292 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5600 ** (%%) ~/~/ Set TCP server address and port 287 287 288 - *(%style="color:#037691" %) **Singal: **(%%)0x17 =23294 + [[image:1670471613823-833.png]] 289 289 290 -*(% style="color:#037691" %) **Mod:**(%%) 0x01 = 1 291 291 292 - *(% style="color:#037691" %) **Calculate Flag:**(%%)0x00=0297 +[[image:image-20221021111131-15.png]] 293 293 294 - *(% style="color:#037691" %) **Contact Status:**(%%) 0x00=0299 + 295 295 296 - *(% style="color:#037691"%)**Alarm:**(%%)0x00=0301 +=== 2.2.7 Change Update Interval === 297 297 298 -*(% style="color:#037691" %) **Total pulse:0x09 =0** 299 299 300 - *(% style="color:#037691" %)The last openduration:**(%%)0x02 =2304 +User can use below command to change the (% style="color:blue" %)**uplink interval**. 301 301 302 -*(% style="color:#037691" %)** imestamp :**(%%)0x6315537b=1662342011(UnixTime)306 +* (% style="color:#037691" %)**AT+TDC=7200 ** (%%) ~/~/ Set Update Interval to 7200s (4 hours) 303 303 304 - *(% style="color:#037691" %)Contact Status,Total pulse, Calculate Flag, The last open duration ,Time stamp:**(%%) 0100000b0200002663510fed308 +(% style="color:red" %)**NOTE:** 305 305 306 - *(%style="color:#037691"%) **8 sets of recorded data: Contact Status,Total pulse,CalculateFlag,Thelast openduration,Timetamp:**(%%) 0100000e0200002663510f39,.......310 +1. By default, the device will send an uplink message every 4 hour. 307 307 308 308 309 -== **2.4Payload Explanation and Sensor Interface**==313 +== 2.3 Uplink Payload == 310 310 311 -=== **2.4.1 Device ID** === 312 312 313 - By default,theDeviceIDisequaltohe last15bitsofIMEI.316 +The uplink payload includes 23 bytes in total by default. 314 314 315 - User can use**AT+DEUI**to setDeviceID318 +Each time the device uploads a data package. The user can use the AT+NOUD command to upload the recorded data.Up to 32 sets of recorded data can be uploaded. 316 316 317 -**Example:** 318 318 319 -AT+DEUI=868411056754138 321 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:450px" %) 322 +|=(% scope="row" style="width: 60px;" %)**Size(bytes)**|(% style="width:50px" %)**8**|(% style="width:30px" %)**2**|(% style="width:30px" %)**2**|(% style="width:75px" %)**1**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:60px" %)**2**|(% style="width:60px" %)**2** 323 +|=(% style="width: 93px;" %)**Value**|(% style="width:67px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:45px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:54px" %)MOD|(% style="width:62px" %)Exit flag|(% style="width:94px" %) [[Distance 1>>||anchor="H2.4.5A0Distance"]] |(% style="width:93px" %) [[Distance 2>>||anchor="H2.4.5A0Distance"]] 320 320 321 -The Device ID is stored in a non-erase area, Upgrade the firmware or run AT+FDR won't erase the Device ID. 325 +(% border="1" style="background-color:#ffffcc; color:green; width:429px" %) 326 +|(% style="width:60px" %)**4**|(% style="width:60px" %)**2**|(% style="width:60px" %)**2**|(% style="width:60px" %)**4**|(% style="width:100px" %)((( 327 +**1-32 group** 328 +))) 329 +|(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.6A0Timestamp"]]| Distance 1 | Distance 2|(% style="width:67px" %)Time stamp|(% style="width:100px" %)... 322 322 331 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NMDS200 uplink data. 323 323 324 - === **2.4.2VersionInfo** ===333 +[[image:1670406261143-723.png]] 325 325 326 -Specify the software version: 0x64=100, which means firmware version 1.00. 327 327 328 - For example 0x00 64: This deviceisCPN01withfirmwareversion1.0.0.336 +The payload is ASCII string, representative same HEX: f867787050471071 0064 0cc3 09 01 00 00ef 013d 6390453d 329 329 338 +**0x (% style="color:red" %)__f867787050471071__ (% style="color:blue" %)__0064__ (% style="color:green" %) __0cc3__(% style="color:#00b0f0" %) 0__9__(% style="color:#7030a0" %) __01__(% style="color:#0020b0" %) __00__ (% style="color:#420042" %)__00ef__(% style="color:#660066" %) (% style="color:#663300" %)__013d__ (% style="color:#d60093" %)__6390453d__(%%)** 330 330 331 - ===**2.4.3 Battery Info**===340 +**where:** 332 332 333 - Checkthebatteryvoltage forCPN01.342 +* (% style="color:#037691" %)**Device ID:**(%%) 0x f867787050471071 = f867787050471071 334 334 335 - Ex1: 0x0B45=2885mV344 +* (% style="color:#037691" %)**Version:**(%%) 0x0064=100=1.0.0 336 336 337 - Ex2: 0x0B49= 2889mV346 +* (% style="color:#037691" %)**BAT :**(%%) 0x0cc3 = 3267 mV = 3.267V 338 338 348 +* (% style="color:#037691" %)**Singal: **(%%)0x09 = 9 339 339 340 - ===**2.4.4SignalStrength** ===350 +* (% style="color:#037691" %)**Mod:**(%%) 0x01 = 1 341 341 342 - NB-IoTNetworksignal Strength.352 +* (% style="color:#037691" %)**Exit flag: **(%%)0x00 =0 343 343 344 -** Ex1: 0x1d=**354 +* (% style="color:#037691" %)**Distance 1: **(%%)0x00ef=239 345 345 346 -* *0**-113dBmor less356 +* (% style="color:#037691" %)**Distance 2: **(%%)0x013d =317 347 347 348 -* *1**-111dBm358 +* (% style="color:#037691" %)**Timestamp: **(%%)0x6390453d =1670399293 (Unix Time) 349 349 350 -**2...30** -109dBm... -53dBm 351 351 352 -**31** -51dBm or greater 353 353 354 - **99**Notknown or notdetectable362 +== 2.4 Payload Explanation and Sensor Interface == 355 355 364 +=== 2.4.1 Device ID === 356 356 357 -=== **2.4.5 Calculate Flag** === 358 358 359 - Thecalculatelag is auser defined field,IoT server can usethis filedto handledifferentmeterswithdifferent pulsefactors.For example, ifthereare 100 water meters, meter1~~50are 1 liter/pulseandmeter 51 ~~ 100 has 1.5 liter/pulse.367 +By default, the Device ID is equal to the last 15 bits of IMEI. 360 360 361 -User can se tcalculate flag to1 formeter1~~50and 2 formeter51 ~~ 100, So IoT Servercan usethis field for calculation.369 +User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID 362 362 363 - Default value:0.371 +**Example:** 364 364 365 - Range (6bits): (b)000000 ~~ (b)111111373 +AT+DEUI=868411056754138 366 366 375 +The Device ID is stored in a non-erase area, Upgrade the firmware or run AT+FDR won't erase the Device ID. 367 367 368 -=== **2.4.6 Alarm** === 369 369 370 - See [[AlarmBase on Timeout>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H3.5AlarmBaseonTimeout]]378 +=== 2.4.2 Version Info === 371 371 372 372 373 - ===**2.4.7ContactStatus**===381 +Specify the software version: 0x64=100, which means firmware version 1.00. 374 374 375 -0: Open383 +For example 0x00 64 : This device is NMDS200 1 with firmware version 1.0.0. 376 376 377 -1: Close 378 378 386 +=== 2.4.3 Battery Info === 379 379 380 -=== **2.4.8 Total pulse** === 381 381 382 - Total pulse/countingbased on dry [[contacttriggerevent>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.2SensorConfiguration2CFPORT3D4]]389 +Check the battery voltage for NMDS200. 383 383 384 - Range (3 Bytes): 0x000000~~0xFFFFFF . Max: 16777215391 +Ex1: 0x0B45 = 2885mV 385 385 393 +Ex2: 0x0B49 = 2889mV 386 386 387 -=== **2.4.9 The last open duration** === 388 388 389 - DryContactlastopenduration.396 +=== 2.4.4 Signal Strength === 390 390 391 -Unit: min. 392 392 393 - [[image:image-20221021111346-17.png||height="146" width="770"]]399 +NB-IoT Network signal Strength. 394 394 401 +(% style="color:blue" %)**Ex1: 0x1d = 29** 395 395 396 -= ==**2.4.10Timestamp** ===403 +(% style="color:#037691" %)**0** (%%) -113dBm or less 397 397 398 - Timestamp:x6315537b=1662342011405 +(% style="color:#037691" %)**1** (%%) -111dBm 399 399 400 - ConvertUnix timestamp totime2022-9-59:40:11.407 +(% style="color:#037691" %)**2...30** (%%) -109dBm... -53dBm 401 401 402 -** ~**409 +(% style="color:#037691" %)**31** (%%) -51dBm or greater 403 403 404 -= =**2.5DownlinkPayload** ==411 +(% style="color:#037691" %)**99** (%%) Not known or not detectable 405 405 406 -By default, CPN01 prints the downlink payload to console port. 407 407 408 - [[image:image-20221021111414-18.png]]414 +=== 2.4.5 Distance === 409 409 410 -**Examples:** 411 411 412 - * **Set TDC**417 +[[image:1670407401682-959.png]] 413 413 414 -If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 415 415 416 - Payload:0100 00 1E TDC=30S420 +(% style="color:blue" %)**Object1 Distance:** 417 417 418 - Payload:0100003CTDC=60S422 +Distance between sensor probe to the first object. (unit: cm) 419 419 420 - ***Reset**424 +For example, if the data you get from the register is 0x02 0x05, the distance between the sensor and the measured object is 421 421 422 - Ifpayload=0x04FF,itwillresettheNSE01426 +(% style="color:blue" %)**0205(H) = 517 (D) = 517 cm.** 423 423 424 -* **INTMOD** 425 425 426 - DownlinkPayload:06000003, SetAT+INTMOD=3429 +(% style="color:blue" %)**Object2 Distance:** 427 427 428 - ==**2.6LEDIndicator**==431 +Distance between sensor probe to the second object. (unit: cm) 429 429 430 -The CPN01 has an internal LED which is to show the status of different states. 431 431 432 -* When power on, CPN01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe) 433 -* Then the LED will be on for 1 second means device is boot normally. 434 -* After CPN01 join NB-IoT network. The LED will be ON for 3 seconds. 435 -* For each uplink probe, LED will be on for 500ms. 434 +=== 2.4.6 Timestamp === 436 436 437 437 438 - == **2.7 Alarm Base onTimeout**==437 +Timestamp : 0x6315537b =1662342011 439 439 440 -CPN01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 441 441 440 +== 2.5 Downlink Payload == 442 442 443 -**~1. Keep Status: Status to be monitor** 444 444 445 - KeepStatus=1: MonitorClosetoOpenvent443 +By default, NMDS200 prints the downlink payload to console port. 446 446 447 - Keep Status = 0:Monitor Opento Close event445 +[[image:image-20221021111414-18.png]] 448 448 449 449 450 -** 2. Keep Time: Timeout tosend an Alarm**448 +**Examples:** 451 451 452 - Range0 ~~ 65535(0xFFFF)seconds.450 +* (% style="color:#037691" %)**Set TDC** 453 453 454 -If keeptime =DisableAlarmBase onTimeoutfeature.452 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 455 455 456 - If keep time > 0, device will monitor the keep status event andsendanalarmwhenstatus doesn’t change after timeout.454 +Payload: 01 00 00 1E TDC=30S 457 457 456 +Payload: 01 00 00 3C TDC=60S 458 458 459 -* *ATCommand** toconfigure:458 +* (% style="color:#037691" %)**Reset** 460 460 461 - **AT+TTRIG=1,30**~-~-> When the **KeepStatus** change from connectedtodisconnect,and device remains in disconnectstatus for more than 30 seconds. CPN01will send an uplink packet,the[[Alarmbit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (the second bit of 1^^st^^ byte of payload) on this uplink packet is set to 1.460 +If payload = 0x04FF, it will reset the NMDS200 462 462 463 -* *AT+TTIG=0,0**~-~-> DefaultValue, disable timeout Alarm.462 +* (% style="color:#037691" %)**INTMOD** 464 464 464 +Downlink Payload: 06000003, Set AT+INTMOD=3 465 465 466 -== **2.8 Set debug mode** == 467 467 468 - Feature:EnableorDisable debug mode467 +== 2.6 LED Indicator == 469 469 470 470 471 - **ATCommand:AT+DEBUG**470 +The NMDS200 has an internal LED which is to show the status of different states. 472 472 473 -[[image:image-20221021111629-21.png]] 472 +* When the device starts normally, the LED will light up for 1 second. 473 +* After NMDS200 join NB-IoT network. The LED will be ON for 3 seconds. 474 +* For each uplink probe, LED will be on for 500ms. 474 474 475 -== **2.9 Clear Flash Record** == 476 476 477 -Feature: Clear flash storage for data log feature. 478 478 479 - **ATCommand:AT+CLRDTA**478 +== 2.7 Distance alarm function == 480 480 481 -[[image:image-20221021111527-19.png]] 482 482 483 -= =**2.10 Settriggermode**==481 +(% style="color:blue" %)**AT Command: AT+ALARM1=min,max** 484 484 485 - ➢AT Command: **AT+TTRMOD**483 +(% style="color:#037691" %)**Example 1:** 486 486 487 - Feature:Set the triggerinterruptmode.485 +AT+ ALARM1 =60,200 ~/~/ Alarm when moisture lower than 60. 488 488 489 - [[image:image-20221021111552-20.png]]487 +AT+ ALARM2 =min,max 490 490 491 -== **2.11 Set the calculate flag** == 492 492 493 - Feature:Setthealculateflag490 +(% style="color:#037691" %)**Example 2:** 494 494 495 - **ATCommand:AT+CALCFLAG**492 +AT+ ALARM2 =200,1500 ~/~/ Alarm when temperature lower than 1500 496 496 497 -[[image:image-20221021111711-22.png]] 498 498 499 -== **2.12count number**==495 +== 2.8 Set the number of data to be uploaded and the recording time == 500 500 501 -Feature: Manually set the count number 502 502 503 -**AT Command: AT+SETCNT**498 +(% style="color:blue" %)**AT Command:** 504 504 505 - [[image:image-20221021111748-24.png]]500 +(% style="color:#037691" %)**AT+TR=900**(%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 506 506 507 -== ** 2.13Setthenumberof datatobeuploaded and the recordingtime**==502 +(% style="color:#037691" %)**AT+NOUD=8**(%%)** ** ~/~/ The device uploads 0 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 508 508 509 -➢ AT Command: 510 510 511 - AT+TR=900~/~/Theunit is seconds,andthedefault is torecorddata onceevery 900 seconds.(The minimum can be setto 180 seconds)505 +== 2.9 Read or Clear cached data == 512 512 513 513 514 - AT+NOUD=8~/~/The device uploads8 sets of recorded databy default. Up to 32 setsofrecord data canbe uploaded.508 +(% style="color:blue" %)**AT Command:** 515 515 516 -= =**2.14Reador Clearcached data** ==510 +(% style="color:#037691" %)**AT+CDP** (%%) ~/~/ Read cached data 517 517 518 - ➢AT Command:512 +(% style="color:#037691" %)**AT+CDP=0** (%%) ~/~/ Clear cached data 519 519 520 - AT+CDP ~/~/ Read cached data514 +[[image:1670408172929-569.png]] 521 521 522 -[[image:image-20221021111810-25.png||height="364" width="797"]] 523 523 517 +== 2.10 Firmware Change Log == 524 524 525 -AT+CDP=0 ~/~/ Clear cached data 526 526 527 - ==**2.15Firmware ChangeLog**==520 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0>>https://www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0]] 528 528 529 - DownloadURL &FirmwareChange log: [[https:~~/~~/www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0>>url:https://www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0]]522 +Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 530 530 531 -Upgrade Instruction: [[Upgrade Firmware>>path:#H5.1200BHowtoUpgradeFirmware]] 532 532 533 -== **2.16Battery Analysis**==525 +== 2.11 Battery Analysis == 534 534 535 -=== **2.16.1 Battery Type**===527 +=== 2.11.1 Battery Type === 536 536 537 -The CPN01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 538 538 530 +The NMDS200 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 531 + 539 539 The battery is designed to last for several years depends on the actual use environment and update interval. 540 540 541 541 The battery-related documents as below: 542 542 543 543 * [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 537 + 544 544 * [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 539 + 545 545 * [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 546 546 547 547 [[image:image-20221021111911-26.png]] 548 548 549 -=== **2.16.2 Power consumption Analyze** === 550 550 545 +=== 2.11.2 Power consumption Analyze === 546 + 547 + 551 551 Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 552 552 553 553 Instruction to use as below: 554 554 555 -**Step 1: **Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 552 +(% style="color:blue" %)**Step 1: **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 556 556 557 -**Step 2: ** Open it and choose 554 +(% style="color:blue" %)**Step 2: **(%%) Open it and choose 558 558 559 559 * Product Model 557 + 560 560 * Uplink Interval 559 + 561 561 * Working Mode 562 562 563 563 And the Life expectation in difference case will be shown on the right. 564 564 565 -[[image: image-20221021111923-27.png||height="253" width="783"]] 564 +[[image:1666596205057-567.png]] 566 566 567 -=== **2.16.3 Battery Note** === 568 568 567 +=== 2.11.3 Battery Note === 568 + 569 + 569 569 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 570 570 571 -=== **2.16.4 Replace the battery** === 572 572 573 - Thedefault battery pack of CPN01 includes a ER26500 plus super capacitor.If user can't find this pack locally, they can find ER26500 orequivalence without the SPC1520 capacitor, which willalso work in mostcase.The SPC can enlargethe batterylife for high frequency use (update period below 5 minutes).573 +=== 2.11.4 Replace the battery === 574 574 575 575 576 - =**3.AccessNB-IoTModule**=576 +The default battery pack of NMDS200 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 577 577 578 + 579 += 3. Access NB-IoT Module = 580 + 581 + 578 578 Users can directly access the AT command set of the NB-IoT module. 579 579 580 580 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 581 581 582 -[[image:image-20221021112006-28.png]] 583 583 584 - = **4. UsingtheAT Commands**=587 +[[image:image-20221118094449-6.png]] 585 585 586 -== **4.1 Access AT Commands** == 587 587 590 += 4. Using the AT Commands = 591 + 592 +== 4.1 Access AT Commands == 593 + 594 + 588 588 See this link for detail: [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 589 589 590 590 AT+<CMD>? : Help on <CMD> ... ... @@ -595,8 +595,9 @@ 595 595 596 596 AT+<CMD>=? : Get the value 597 597 598 -**General Commands** 599 599 606 +(% style="color:blue" %)**General Commands** 607 + 600 600 AT : Attention 601 601 602 602 AT? : Short Help ... ... @@ -611,134 +611,107 @@ 611 611 612 612 AT+INTMOD : Set the trigger interrupt mode 613 613 614 -AT+5VT 622 +AT+5VT : Set extend the time of 5V power 615 615 616 -AT+PRO 624 +AT+PRO : Choose agreement 617 617 618 -AT+RXDL 626 +AT+RXDL : Extend the sending and receiving time 619 619 620 -AT+SERVADDR 628 +AT+SERVADDR : Server Address 621 621 622 -AT+TR : Get or Set record time "630 +AT+TR : Get or Set record time 623 623 632 +AT+NOUD : Get or Set the number of data to be uploaded 624 624 625 -AT+ NOUDGetorSetthenumber ofdatato be uploaded634 +AT+CDP : Read or Clear cached data 626 626 636 +AT+DEBUG: Enable or Disable debug mode 627 627 628 -AT+ CDP: ReadorClearcacheddata638 +AT+ALARM1: Get or Set alarm of distance1 629 629 640 +AT+ALARM2: Get or Set alarm of distance2 630 630 631 -AT+ DEBUG:EnableorDisabledebugmode642 +AT+GETSENSORVALUE : Returns the current sensor measurement 632 632 633 -AT+ TTRIG: Get orSetAlarm Base on Timeout644 +AT+POWERIC : Get or set the Power IC flag 634 634 635 -AT+ TTRMOD : Get or Set the trigger interrupt mode(0:falling,1:rising) 636 636 637 - AT+CALCFLAG : GetSetthecalculateflag647 +(% style="color:blue" %)**COAP Management** 638 638 639 -AT+ CLRC:Clearcurrentdoor open count649 +AT+URI : Resource parameters 640 640 641 -**COAP Management** 642 642 643 - AT+URI: Resourceparameters652 +(% style="color:blue" %)**UDP Management** 644 644 645 - **UDPManagement**654 +AT+CFM : Upload confirmation mode (only valid for UDP) 646 646 647 -AT+CFM : Upload confirmation mode (only valid for UDP) 648 648 649 -**MQTT Management** 657 +(% style="color:blue" %)**MQTT Management** 650 650 651 -AT+CLIENT 659 +AT+CLIENT : Get or Set MQTT client 652 652 653 -AT+UNAME 661 +AT+UNAME : Get or Set MQTT Username 654 654 655 -AT+PWD 663 +AT+PWD : Get or Set MQTT password 656 656 657 -AT+PUBTOPIC :Get or Set MQTT publish topic665 +AT+PUBTOPIC : Get or Set MQTT publish topic 658 658 659 -AT+SUBTOPIC :Get or Set MQTT subscription topic667 +AT+SUBTOPIC : Get or Set MQTT subscription topic 660 660 661 -**Information** 662 662 663 - AT+FDR: FactoryDataReset670 +(% style="color:blue" %)**Information** 664 664 665 -AT+ PWORD:SerialAccessPassword672 +AT+FDR : Factory Data Reset 666 666 667 - =**5.FAQ**=674 +AT+PWORD : Serial Access Password 668 668 669 -== **5.1 How to Upgrade Firmware** == 670 670 671 - Usercanupgradethe firmware for 1) bug fix, 2) new feature release.677 += 5. FAQ = 672 672 673 - Pleaseseethislink for how toupgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]679 +== 5.1 How to Upgrade Firmware == 674 674 675 -**Notice, **CPN01 **and **CPL01 **share the same mother board. They use the same connection and method to update.** 676 676 677 - 682 +User can upgrade the firmware for 1) bug fix, 2) new feature release. 678 678 679 - =**6.Trouble** =684 +Please see this link for how to upgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]] 680 680 681 -= =**6.1 Connectionproblemwhenuploadingfirmware**==686 +(% style="color:red" %)**Notice: **(% style="color:blue" %)**NMDS200** (%%)**and (% style="color:blue" %)LMDS200(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.** 682 682 683 -**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]] 684 684 689 += 6. Trouble Shooting = 685 685 686 -== **6.2ATCommand inputdoesn'twork**==691 +== 6.1 Connection problem when uploading firmware == 687 687 688 -In the case if user can see the console output but can't type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn't send **ENTER** while press the send key, user need to add ENTER in their string. 689 689 694 +(% style="color:blue" %)**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]] 690 690 691 -= **7. Order Info** = 692 692 693 - PartNumber**:** CPN01697 +== 6.2 AT Command input doesn't work == 694 694 695 695 696 - =**8.Info**=700 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string. 697 697 698 -**Package Includes**: 699 699 700 -* CPN01 Open/Close Sensor x 1 701 -* External antenna x 1 703 += 7. Order Info = 702 702 703 -**Dimension and weight**: 704 704 705 -* Size: 195 x 125 x 55 mm 706 -* Weight: 420g 706 +Part Number:(% style="color:blue" %)** NMDS200** 707 707 708 -= **9. Support** = 709 709 710 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 711 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 709 += 8. Packing Info = 712 712 713 - 714 714 712 +(% style="color:blue" %)**Package Includes**: 715 715 714 +* NMDS200 NB-IoT Microwave Radar Distance Sensor x 1 716 716 717 717 718 718 718 += 9. Support = 719 719 720 720 721 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 721 721 723 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 722 722 723 - 724 - 725 - 726 - 727 - 728 - 729 - 730 - 731 - 732 - 733 - 734 - 735 - 736 - 737 - 738 - 739 - 740 - 741 - 742 - 743 - 744 - 725 +
- 1666596205057-567.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +179.8 KB - Content
- 1670404362039-351.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +492.6 KB - Content
- 1670405841875-916.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.1 KB - Content
- 1670405928926-116.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.7 KB - Content
- 1670406036256-101.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +181.0 KB - Content
- 1670406261143-723.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.9 KB - Content
- 1670407401682-959.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.7 KB - Content
- 1670408172929-569.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +211.8 KB - Content
- 1670471530120-960.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +67.6 KB - Content
- 1670471559211-638.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +170.6 KB - Content
- 1670471584490-640.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.1 KB - Content
- 1670471613823-833.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +181.0 KB - Content
- LMDS200_10.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.9 KB - Content
- image-20221117105556-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.3 KB - Content
- image-20221117114459-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content
- image-20221117114842-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +964.1 KB - Content
- image-20221117114937-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.1 KB - Content
- image-20221117114949-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.4 KB - Content
- image-20221117115010-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.4 KB - Content
- image-20221117142300-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +147.8 KB - Content
- image-20221117145932-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.9 KB - Content
- image-20221117150312-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.7 KB - Content
- image-20221118092935-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- image-20221118093144-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.7 KB - Content
- image-20221118093512-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.5 KB - Content
- image-20221118093658-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.7 KB - Content
- image-20221118094227-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- image-20221118094449-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.5 KB - Content
- image-20221118103445-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- image-20221118103453-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.2 KB - Content
- image-20221118103547-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.5 KB - Content
- image-20221207170748-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.1 KB - Content
- image-20221207170748-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.9 KB - Content
- image-20221207173200-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.7 KB - Content
- image-20221207173300-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.0 KB - Content
- image-20221208090742-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.7 KB - Content