Changes for page NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 17:03
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 33 added, 0 removed)
- 1666596205057-567.png
- 1670404362039-351.png
- 1670405841875-916.png
- 1670405928926-116.png
- 1670406036256-101.png
- 1670406261143-723.png
- 1670407401682-959.png
- 1670408172929-569.png
- LMDS200_10.jpg
- image-20221023000439-3.png
- image-20221117105556-1.png
- image-20221117114459-2.png
- image-20221117114842-3.png
- image-20221117114937-4.png
- image-20221117114949-5.png
- image-20221117115010-6.png
- image-20221117142300-1.png
- image-20221117145932-2.png
- image-20221117150312-3.png
- image-20221118092935-1.png
- image-20221118093144-2.png
- image-20221118093512-3.png
- image-20221118093658-4.png
- image-20221118094227-5.png
- image-20221118094449-6.png
- image-20221118103445-7.png
- image-20221118103453-8.png
- image-20221118103547-9.png
- image-20221207170748-1.png
- image-20221207170748-2.png
- image-20221207173200-3.png
- image-20221207173300-4.png
- image-20221208090742-1.png
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - CPN01- NB-IoTOutdoorOpen/CloseDryContactSensor User Manual1 +NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -1,34 +1,44 @@ 1 1 (% style="text-align:center" %) 2 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652856952171-363.png?rev=1.1||alt="1652856952171-363.png" height="578" width="588"]]2 +[[image:LMDS200_10.jpg]] 3 3 4 -{{toc/}} 5 5 6 - =**1.Introduction**=5 +**Table of Contents:** 7 7 8 -== **1.1 **What is CPN01 **NB-IoT** Pulse/Contact Sensor == 9 9 10 -The Dragino CPN01 is an (% style="color:blue" %)**NB-IoT Dry Contact Sensor**(%%). It detects open/close status and uplinks the info to IoT server via Nb-IoT network. User can see the (% style="color:blue" %)dry contact status, open time, and open counts(%%) in the IoT Server. 11 11 12 -The CPN01 will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculates the last open duration. Users can also disable the uplink for each open/close event, instead, device can count each open event and uplink periodically. 13 13 14 -CPN01 has (% style="color:blue" %)Open-Alarm feature(%%), user can set this feature so CPN01 will send an alarm if the contact has been open exceeds a certain time. 15 15 16 - CPN01is designed for outdoor use. Ithas a weatherproof enclosure andindustrial-level battery towork inlow to high temperatures.11 += 1. Introduction = 17 17 18 -NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity, and spectrum efficiency, especially in deep coverage. 19 -\\CPN01 supports different uplink methods including (% style="color:blue" %)**TCP, MQTT, UDP, and CoAP**(%%) for different application requirements. 20 -\\CPN01 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long-term use of up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 21 -\\To use CPN01, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that CPN01 supports. If local operator support it, user needs to get a (% style="color:blue" %)**NB-IoT SIM card**(%%) from the operator and install into CPN01 to get NB-IoT network connection. 13 +== 1.1 What is NMDS200 NB-IoT Microwave Radar Distance Sensor == 22 22 23 - 24 24 25 -== **1.2 Features** == 16 +((( 17 +The Dragino NMDS200 is a(% style="color:blue" %)** NB-IoT Microwave Radar distance sensor**(%%). It uses (% style="color:blue" %)**24Ghz Microwave**(%%) to detect the distance between sensor and different objects. Compare vs ultrasonic or Lidar measurement method, Microwave Radar is (% style="color:blue" %)**more reliable for condensation / dusty environment**(%%). It can sense correct distance even there is water or thick dust on top of the sensor. 26 26 19 +The NMDS200 can be applied to scenarios such as horizontal distance measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, etc. 20 + 21 +NMDS200 can (% style="color:blue" %)**measure two distances**(%%): the closest object and next object behind the closest one. 22 + 23 +NMDS200 (% style="color:blue" %)**supports Alarm Feature**(%%), user can set the NMDS200 to uplink data in a short interval when the distance is out of configured range. 24 + 25 +NarrowBand-Internet of Things (NB-IoT) is a (% style="color:blue" %)**standards-based low power wide area (LPWA) technology**(%%) developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity, and spectrum efficiency, especially in deep coverage. 26 + 27 +NMDS200 (% style="color:blue" %)**supports different uplink**(%%) methods including (% style="color:blue" %)**TCP, MQTT, UDP, and CoAP**(%%) for different application requirements. 28 + 29 +NMDS200 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**,(%%) It is designed for long-term use of up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 30 + 31 +To use NMDS200, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that NMDS200 supports. If local operator support it, user needs to get a** (% style="color:blue" %)NB-IoT SIM card(%%)** from the operator and install into NMDS200 to get NB-IoT network connection. 32 +))) 33 + 34 + 35 +== 1.2 Features == 36 + 37 + 27 27 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD 28 -* Open/Close detect 29 -* Open/Close statistics 39 +* Short uplink interval for Distance Alarm 30 30 * Monitor Battery Level 31 -* Uplink on periodicallyand open/close event41 +* Microwave Radar for distance detection 32 32 * Datalog feature 33 33 * Uplink periodically 34 34 * Downlink to change configure ... ... @@ -39,289 +39,326 @@ 39 39 * Micro SIM card slot for NB-IoT SIM 40 40 * 8500mAh Battery for long-term use 41 41 42 -== **1.3Specification**==52 +== 1.3 Radar probe specification == 43 43 44 -**Common DC Characteristics:** 45 45 46 -* Supply Voltage: 2.1v ~~ 3.6v 47 -* Operating Temperature: -40 ~~ 85°C 55 +* Measuring Method: FMCW 56 +* Frequency: 24.000 24.500 GHz 57 +* Measurement output power: 6dBm 58 +* Measure range: 0.5 20m 59 +* Accuracy: ±0.1m 60 +* Resolution: 0.01m 61 +* Horizontal Angel: 78° 62 +* Vertical Angel: 23° 48 48 49 - **NB-IoTSpec:**64 +== 1.4 Storage Temperature == 50 50 51 -* - B1 @H-FDD: 2100MHz 52 -* - B3 @H-FDD: 1800MHz 53 -* - B8 @H-FDD: 900MHz 54 -* - B5 @H-FDD: 850MHz 55 -* - B20 @H-FDD: 800MHz 56 -* - B28 @H-FDD: 700MHz 57 57 58 - ==**1.4Installation**==67 + -40°C to +85°C 59 59 60 -Connect CPL01 to an Open Close sensor like below. So it can detect the open/close event. 61 61 62 - [[image:image-20221021110329-1.png]]70 +== 1.5 Applications == 63 63 64 -[[image:image-20221021110340-2.png]] 65 65 66 -== **1.5 Applications** == 73 +* Horizontal distance measurement 74 +* Liquid level measurement 75 +* Parking management system 76 +* Object proximity and presence detection 77 +* Intelligent trash can management system 78 +* Robot obstacle avoidance 79 +* Automatic control 80 +* Sewer 81 +* Bottom water level monitoring 67 67 68 -* Open/Close Detection 69 -* Pulse meter application 70 -* Dry Contact Detection 83 +== 1.6 Specification == 71 71 72 -== **1.6 Mechanical** == 73 73 74 - [[image:image-20221021110415-3.png]]86 +(% style="color:blue" %)**Common DC Characteristics:** 75 75 76 -== ** 1.7 Pin Definitions and Switch** == 88 +* Supply Voltage: 2.1v ~~ 3.6v 89 +* Operating Temperature: 0 ~~ 70°C 77 77 78 - [[image:image-20221021110429-4.png]]91 +(% style="color:blue" %)**NB-IoT Spec:** 79 79 80 -=== **1.7.1 Pin Definition** === 93 +* B1 @H-FDD: 2100MHz 94 +* B3 @H-FDD: 1800MHz 95 +* B8 @H-FDD: 900MHz 96 +* B5 @H-FDD: 850MHz 97 +* B20 @H-FDD: 800MHz 98 +* B28 @H-FDD: 700MHz 81 81 82 - CPL01is pre-configured to connect to two external wires.The other pins are not used.If user wantso know moreabout other pins, please refertothe user manualof LSN50v2 at: [[https:~~/~~/www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0>>url:https://www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0]]100 +== 1.7 Installation == 83 83 84 -=== **1.7.2 Jumper JP2(Power ON/OFF)** === 85 85 103 +Sensor measure direction and angle is as below. When install the sensor, please make sure the sensor direct to object. 86 86 87 -Power on Device when putting this jumper. 88 88 106 +[[image:image-20221207170748-1.png]] [[image:image-20221207170748-2.png||height="366" width="672"]] 89 89 90 90 91 -=== **1.7.3 BOOT MODE / SW1** === 92 92 110 +== 1.8 Pin Definitions and Switch == 93 93 94 -1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run. 95 95 96 - 2) Flash: work mode, the device starts to work and send out console output for further debug113 +[[image:1670404362039-351.png]] 97 97 98 98 116 += 2. Use NMDS200 to communicate with IoT Server = 99 99 100 -== =**1.7.4ResetButton**===118 +== 2.1 How it works == 101 101 102 102 103 - Pressto rebootthe device.121 +The NB-IoT network will forward this value to IoT server via the protocol defined by NMDS200. 104 104 105 - ====123 +The diagram below shows the working flow in the default firmware of NMDS200: 106 106 107 - === **1.7.5LED** ===125 +[[image:image-20221021110615-5.png]] 108 108 109 109 110 - Itwillflash:128 +== 2.2 Configure NMDS200 == 111 111 112 -1. Boot the device in flash mode 113 -1. Send an uplink packet 114 114 115 - =**2. UseCPN01tocommunicatewithIoTServer** =131 +To use NMDS200 in your city, make sure to meet below requirements: 116 116 117 -== **2.1 How it works** == 133 +* Your local operator has already distributed an NB-IoT Network. 134 +* The local NB-IoT network used the band that NMDS200 supports. 135 +* Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 118 118 119 - TheCPN01isequippedwitha NB-IoTmodule, thepre-loadedfirmware inCPN01willgetenvironmentdatafromsensorsandsendthe valuetocalNB-IoTnetworkviatheNB-IoT module.The NB-IoTnetworkwillforward this valuetoIoTservervia theprotocoldefined by CPN01.137 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NMDS200 will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server. 120 120 121 - The diagram below shows the working flow in default firmwareof CPN01:139 +[[image:image-20221208090742-1.png]] 122 122 123 -[[image:image-20221021110615-5.png]] 124 124 125 -== **2.2ConfigureheCPN01**==142 +=== 2.2.1 Insert NB-IoT SIM card === 126 126 127 -=== **2.2.1 Test Requirement** === 128 128 129 - To useCPN01 in yourcity,makesuremeetbelowrequirements:145 +Insert the NB-IoT Card get from your provider. 130 130 131 -* Your local operator has already distributed a NB-IoT Network there. 132 -* The local NB-IoT network used the band that CPN01 supports. 133 -* Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 147 +User needs to take out the NB-IoT module and insert the SIM card like below: 134 134 135 - Below figureshows our testing structure. Here we have NB-IoT network coverageby China Mobile, the band they use is B8. The CPN01 will use CoAP(120.24.4.116:5683) or raw UDP(120.24.4.116:5601) or MQTT(120.24.4.116:1883)or TCP(120.24.4.116:5600)protocol to senddata to the test server149 +[[image:image-20221021110745-6.png]] 136 136 137 - 138 138 139 -=== **2.2.2Insert SIMcard**===152 +=== 2.2.2 Connect USB – TTL to NMDS200 and configure it === 140 140 141 -Insert the NB-IoT Card get from your provider. 142 142 143 -User need to take out theNB-IoTmodule and insert theSIMcardlike below:155 +User need to configure NMDS200 via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NMDS200 support AT Commands, user can use a USB to TTL adapter to connect to NMDS200 and use AT Commands to configure it, as below. 144 144 145 - [[image:image-20221021110745-6.png]]157 +(% style="color:blue" %)**Connection:** 146 146 147 - ===**2.2.3 ConnectUSB–TTLto CPN01toconfigure it**===159 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 148 148 149 - Usereedtoconfigure CPN01 via serialport to set the **Server Address** / **Uplink Topic**todefine where and how-to uplink packets. CPN01 support AT Commands, user can use aUSBtoTTLadaptertoconnect to CPN01 and useATCommands to configure it, as below.161 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 150 150 151 - **Connection:**163 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 152 152 153 - USB TTL GND <~-~-~-~-> GND 154 154 155 - USBTTLTXD<~-~-~-~->UART_RXD166 +In the PC, use below serial tool settings: 156 156 157 - USBTTLRXD<~-~-~-~->UART_TXD168 +* Baud: (% style="color:red" %)**9600** 158 158 159 - InthePC, usebelow serialtoolsettings:170 +* Data bits:** (% style="color:red" %)8(%%)** 160 160 161 -* Baud: **9600** 162 -* Data bits:** 8** 163 -* Stop bits: **1** 164 -* Parity: **None** 165 -* Flow Control: **None** 172 +* Stop bits: (% style="color:red" %)**1** 166 166 167 - Makesure the switch is in FLASH position, then power on device byconnectingthejumperonCPN01.CPN01 will outputsystem info once power on as below, we can enterthe **password:12345678**toaccess AT Command input.174 +* Parity: (% style="color:red" %)**None** 168 168 176 +* Flow Control: (% style="color:red" %)**None** 177 + 178 +Make sure the switch is in FLASH position, then power on NMDS200 by connecting the (% style="color:orange" %)**Yellow Jumper**(%%). 179 + 169 169 [[image:image-20221021110817-7.png]] 170 170 171 - **Note:thevalidAT Commands canbefoundat:**[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]182 +NMDS200 will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input. 172 172 173 -=== **2.2.4 Use CoAP protocol to uplink data** === 174 174 175 -**Note: if you don'taveCoAP server,youcanrefer thislinkto setupone: **[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]185 +(% style="color:red" %)**Note: the valid AT Commands can be found at: **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 176 176 177 -**Use below commands:** 178 178 179 -* **AT+PRO=1** ~/~/ Set to use CoAP protocol to uplink 180 -* **AT+SERVADDR=120.24.4.116,5683 ** ~/~/ to set CoAP server address and port 181 -* **AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** ~/~/Set COAP resource path 182 182 189 +=== 2.2.3 Use CoAP protocol to uplink data === 190 + 191 + 192 +(% style="color:red" %)**Note: if you don't have a CoAP server, you can refer this link to set up a CoAP server: **(%%)[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 193 + 194 + 195 +(% style="color:blue" %)**Use below commands in NMDS200:** 196 + 197 +* (% style="color:#037691" %)**AT+PRO=1** (%%) ~/~/ Set to use CoAP protocol to uplink 198 + 199 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5683 ** (%%) ~/~/ Set CoAP server address and port 200 + 201 +* (% style="color:#037691" %)**AT+URI=0,0,11,2,"mqtt" ** (%%) ~/~/ Set CoAP resource path 202 + 183 183 For parameter description, please refer to AT command set 184 184 185 185 [[image:image-20221021110948-8.png]] 186 186 187 -After configure the server address and **reset the device** (via AT+ATZ ), CPN01 will start to uplink sensor values to CoAP server. 188 188 189 - [[image:image-20221021110956-9.png]]208 +After configuring the server address and (% style="color:green" %)**reset NMDS200**(%%) (via AT+ATZ ), NMDS200 will start to uplink sensor values to the CoAP server. 190 190 191 - === **2.2.5 Use UDP protocol to uplink data(Defaultprotocol)**===210 +[[image:1670405841875-916.png]] 192 192 193 -This feature is supported since firmware version v1.0.1 194 194 195 -* **AT+PRO=2 ** ~/~/ Set to use UDP protocol to uplink 196 -* **AT+SERVADDR=120.24.4.116,5601 ** ~/~/ to set UDP server address and port 197 -* **AT+CFM=1 ** ~/~/If the server does not respond, this command is unnecessary 213 +=== 2.2.4 Use UDP protocol to uplink data(Default protocol) === 198 198 215 + 216 +(% style="color:blue" %)**AT Commands:** 217 + 218 +* (% style="color:#037691" %)**AT+PRO=2 ** (%%) ~/~/ Set to use UDP protocol to uplink 219 + 220 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5601 ** (%%) ~/~/ Set UDP server address and port 221 + 222 +* (% style="color:#037691" %)**AT+CFM=1 ** (%%) ~/~/ If the server does not respond, this command is unnecessary 223 + 199 199 [[image:image-20221021111025-10.png]] 200 200 226 + 201 201 [[image:image-20221021111033-11.png||height="241" width="576"]] 202 202 203 203 204 204 205 -=== **2.2.6Use MQTT protocol to uplink data**===231 +=== 2.2.5 Use MQTT protocol to uplink data === 206 206 207 -This feature is supported since firmware version v110 208 208 209 -* **AT+PRO=3 ** ~/~/Set to use MQTT protocol to uplink 210 -* **AT+SERVADDR=120.24.4.116,1883 ** ~/~/Set MQTT server address and port 211 -* **AT+CLIENT=CLIENT ** ~/~/Set up the CLIENT of MQTT 212 -* **AT+UNAME=UNAME **~/~/Set the username of MQTT 213 -* **AT+PWD=PWD **~/~/Set the password of MQTT 214 -* **AT+PUBTOPIC=NSE01_PUB **~/~/Set the sending topic of MQTT 215 -* **AT+SUBTOPIC=NSE01_SUB ** ~/~/Set the subscription topic of MQTT 234 +(% style="color:blue" %)**AT Commands:** 216 216 217 - [[image:image-20221021111058-12.png]]236 +* (% style="color:#037691" %)**AT+PRO=3 ** (%%) ~/~/ Set to use MQTT protocol to uplink 218 218 219 - [[image:image-20221021111108-13.png]]238 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,1883 ** (%%) ~/~/ Set MQTT server address and port 220 220 240 +* (% style="color:#037691" %)**AT+CLIENT=CLIENT ** (%%) ~/~/ Set up the CLIENT of MQTT 241 + 242 +* (% style="color:#037691" %)**AT+UNAME=UNAME **(%%)** **~/~/ Set the username of MQTT 243 + 244 +* (% style="color:#037691" %)**AT+PWD=PWD **(%%)** **~/~/ Set the password of MQTT 245 + 246 +* (% style="color:#037691" %)**AT+PUBTOPIC=NSE01_PUB **(%%)** **~/~/ Set the sending topic of MQTT 247 + 248 +* (% style="color:#037691" %)**AT+SUBTOPIC=NSE01_SUB ** (%%) ~/~/ Set the subscription topic of MQTT 249 + 250 + [[image:image-20221118103445-7.png]] 251 + 252 + 253 +[[image:1670405928926-116.png]] 254 + 221 221 222 222 223 -MQTT protocol has a much higher power consumption compare vsUDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.257 +MQTT protocol has a much higher power consumption compare with UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 224 224 225 -=== **2.2.7 Use TCP protocol to uplink data** === 226 226 227 - Thisfeatureissupported sincefirmwareversionv110260 +=== 2.2.6 Use TCP protocol to uplink data === 228 228 229 -* **AT+PRO=4 ** ~/~/ Set to use TCP protocol to uplink 230 -* **AT+SERVADDR=120.24.4.116,5600 ** ~/~/ to set TCP server address and port 231 231 232 - [[image:image-20221021111125-14.png]]263 +(% style="color:blue" %)**AT Commands:** 233 233 265 +* (% style="color:#037691" %)**AT+PRO=4 ** (%%) ~/~/ Set to use TCP protocol to uplink 266 + 267 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5600 ** (%%) ~/~/ Set TCP server address and port 268 + 269 + [[image:1670406036256-101.png||height="676" width="713"]] 270 + 271 + 234 234 [[image:image-20221021111131-15.png]] 235 235 236 236 237 237 238 -=== **2.2.8Change Update Interval**===276 +=== 2.2.7 Change Update Interval === 239 239 240 -User can use below command to change the **uplink interval**. 241 241 242 - ***AT+TDC=600**~/~/SetUpdateIntervalto 600s279 +User can use below command to change the (% style="color:blue" %)**uplink interval**. 243 243 244 -** NOTE:**281 +* (% style="color:#037691" %)**AT+TDC=7200 ** (%%) ~/~/ Set Update Interval to 7200s (4 hours) 245 245 246 - **~1.Bydefault, thedevice will sendan uplink message every 1 hour.**283 +(% style="color:red" %)**NOTE:** 247 247 248 - == **2.3UplinkPayload**==285 +1. By default, the device will send an uplink message every 4 hour. 249 249 250 -In this mode, uplink payload includes 87 bytes in total by default. 251 251 252 - Eachtimethe device uploads a data package,8 sets of recorded data will be attached. Up to32 sets of recorded data can be uploaded.288 +== 2.3 Uplink Payload == 253 253 254 -|**Size(bytes)**|**8**|**2**|**2**|**1**|**1**|**1**|**2**|**2**|4 255 -|**Value**|[[Device ID>>path:#H2.4.1A0A0DeviceID]]|[[Ver>>path:#H2.4.2A0VersionInfo]]|[[BAT>>path:#H2.4.3A0BatteryInfo]]|[[Signal Strength>>path:#H2.4.4A0SignalStrength]]|MOD|[[Interrupt>>path:#H2.4.8A0DigitalInterrupt]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|Time stamp 256 256 257 -|2|2|4|8 group 258 -|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|Time stamp|... 291 +The uplink payload includes 23 bytes in total by default. 259 259 260 - IfweusetheMQTT client to subscribetothisMQTTtopic,we can seethefollowinginformationwhentheCPN01uplinkdata.293 +Each time the device uploads a data package. The user can use the AT+NOUD command to upload the recorded data.Up to 32 sets of recorded data can be uploaded. 261 261 262 -[[image:image-20221021111201-16.png||height="572" width="792"]] 263 263 264 -The payload is ASCII string, representative same HEX: 296 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:510px" %) 297 +|=(% scope="row" style="width: 50px;" %)**Size(bytes)**|(% style="width:50px" %)**8**|(% style="width:20px" %)**2**|(% style="width:20px" %)**2**|(% style="width:65px" %)**1**|(% style="width:25px" %)**1**|(% style="width:50px" %)**1**|(% style="width:90px" %)**2**|(% style="width:100px" %)**2** 298 +|=(% style="width: 93px;" %)**Value**|(% style="width:67px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:45px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:54px" %)MOD|(% style="width:62px" %)Exit flag|(% style="width:94px" %) Distance 1 |(% style="width:93px" %) Distance 2 265 265 266 -**0x (% style="color:red" %)__0xf867787050213317__ (% style="color:blue" %)__0064__ (% style="color:green" %)_0c78__ __(% style="color:#00b0f0" %)17__ __(% style="color:#7030a0" %)01__ __(% style="color:#d60093" %)00__ __(% style="color:#a14d07" %)01 __ __(% style="color:#0020b0" %)__ __00__ __(% style="color:#420042" %)000009__ __(% style="color:#663300" %) 000002__ __(% style="color:#d60093" %)6315537bb__ __(% style="color:#663300" %)// 0100000b02000002663510fed__ __0100000e0200000263510f39 010000000000000063510e85 010000000000000063510d2e 010000000000000063510c7a 010000000000000063510bc6 010000000000000063510954 010000000000000063510882 //(%%)** 300 +(% border="1.5" style="background-color:#ffffcc; color:green; width:450px" %) 301 +|(% style="width:50px" %)**4**|(% style="width:90px" %)**2**|(% style="width:90px" %)**2**|(% style="width:60px" %)**4**|(% style="width:50px" %)((( 302 +**1-32 group** 303 +))) 304 +|(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.7A0Timestamp"]]| Distance 1 | Distance 2|(% style="width:67px" %)Time stamp|(% style="width:74px" %)... 267 267 268 -where: 269 -*(% style="color:#037691" %) **Device ID:**(%%) 0x f867787050213317 = f867787050213317 306 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NMDS200 uplink data. 270 270 271 - *(% style="color:#037691" %) **Version:**(%%)0x0064=100=1.0.0308 +[[image:1670406261143-723.png]] 272 272 273 -*(% style="color:#037691" %) **BAT:**(%%) 0x0c78 = 3192 mV = 3.192V 274 274 275 - *(%style="color:#037691"%)**Singal:**(%%)0x17=23311 +The payload is ASCII string, representative same HEX: f867787050471071 0064 0cc3 09 01 00 00ef 013d 6390453d 276 276 277 -*(% style="color: #037691" %)**Mod:**(%%) 0x01 =1313 +**0x (% style="color:red" %)__f867787050471071__ (% style="color:blue" %)__0064__ (% style="color:green" %) __0cc3__(% style="color:#00b0f0" %) 0__9__(% style="color:#7030a0" %) __01__(% style="color:#0020b0" %) __00__ (% style="color:#420042" %)__00ef__(% style="color:#660066" %) (% style="color:#663300" %)__013d__ (% style="color:#d60093" %)__6390453d__(%%)** 278 278 279 -* (% style="color:#037691" %) **CalculateFlag:**(%%) 0x00= 0315 +**where:** 280 280 281 -*(% style="color:#037691" %) ContactStatus:**(%%) 0x00= 0317 +* (% style="color:#037691" %)**Device ID:**(%%) 0x f867787050471071 = f867787050471071 282 282 283 -*(% style="color:#037691" %) Alarm:**(%%)0x00319 +* (% style="color:#037691" %)**Version:**(%%) 0x0064=100=1.0.0 284 284 285 -*(% style="color:#037691" %) otalpulse:0x09=0**321 +* (% style="color:#037691" %)**BAT :**(%%) 0x0cc3 = 3267 mV = 3.267V 286 286 287 -*(% style="color:#037691" %) The last open duration:**(%%)0x02=2323 +* (% style="color:#037691" %)**Singal: **(%%)0x09 = 9 288 288 289 -*(% style="color:#037691" %)** Time stamp:**(%%) 0x6315537b=1662342011325 +* (% style="color:#037691" %)**Mod:**(%%) 0x01 = 1 290 290 291 -*(% style="color:#037691" %) ContactStatus, Totalpulse, Calculate Flag, The last open duration ,Time stamp:**(%%)100000b0200002663510fed327 +* (% style="color:#037691" %)**Exit flag: **(%%)0x00 =0 292 292 293 -*(% style="color:#037691" %) 8sets of recorded data: Contact Status, Total pulse,Calculate Flag, The last open duration ,Time stamp:**(%%)100000e0200002663510f39,.......329 +* (% style="color:#037691" %)**Distance 1: **(%%)0x00ef=239 294 294 295 - ==**2.4Payload Explanation and SensorInterface** ==331 +* (% style="color:#037691" %)**Distance 2: **(%%)0x013d =317 296 296 297 -= ==**2.4.1 DeviceID** ===333 +* (% style="color:#037691" %)**Timestamp: **(%%)0x6390453d =1670399293 (Unix Time) 298 298 299 - Bydefault,the Device ID equaltothelast15bitsfIMEI.335 +== 2.4 Payload Explanation and Sensor Interface == 300 300 301 - Usercan use **AT+DEUI** to set Device ID337 +=== 2.4.1 Device ID === 302 302 339 + 340 +By default, the Device ID is equal to the last 15 bits of IMEI. 341 + 342 +User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID 343 + 303 303 **Example:** 304 304 305 305 AT+DEUI=868411056754138 306 306 307 -The Device ID is stored in a non e-erase area, Upgrade the firmware or run AT+FDR won't erase Device ID.348 +The Device ID is stored in a non-erase area, Upgrade the firmware or run AT+FDR won't erase the Device ID. 308 308 309 -=== **2.4.2 Version Info** === 310 310 311 - Specifythesoftwareversion:0x64=100, meansfirmware version1.00.351 +=== 2.4.2 Version Info === 312 312 313 -For example: 0x00 64 : this device is CPN01 with firmware version 1.0.0. 314 314 315 - ===**2.4.3BatteryInfo**===354 +Specify the software version: 0x64=100, which means firmware version 1.00. 316 316 317 - CheckthebatteryvoltageforCPN01.356 +For example 0x00 64 : This device is NMDS200 1 with firmware version 1.0.0. 318 318 358 + 359 +=== 2.4.3 Battery Info === 360 + 361 + 362 +Check the battery voltage for NMDS200. 363 + 319 319 Ex1: 0x0B45 = 2885mV 320 320 321 321 Ex2: 0x0B49 = 2889mV 322 322 323 -=== **2.4.4 Signal Strength** === 324 324 369 +=== 2.4.4 Signal Strength === 370 + 371 + 325 325 NB-IoT Network signal Strength. 326 326 327 327 **Ex1: 0x1d = 29** ... ... @@ -336,58 +336,44 @@ 336 336 337 337 **99** Not known or not detectable 338 338 339 -=== **2.4.5 Calculate Flag** === 340 340 341 - Thecalculateflagisa user define field, IoT server can usethis filed to handle different meter with different pulse factor. Forexample,if there are 100 water meters, meter 1 ~~50 are 1 liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse.387 +=== 2.4.5 Distance === 342 342 343 -User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation. 344 344 345 - Default value:390 +[[image:1670407401682-959.png]] 346 346 347 -Range (6 bits): (b)000000 ~~ (b) 111111 348 348 349 -= ==**2.4.6Alarm**===393 +(% style="color:blue" %)**Object1 Distance:** 350 350 351 - See [[Alarm Base on Timeout>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H3.5AlarmBaseonTimeout]]395 +Distance between sensor probe to the first object. (unit: cm) 352 352 353 - ===**2.4.7ContactStatus**===397 +For example, if the data you get from the register is 0x02 0x05, the distance between the sensor and the measured object is 354 354 355 - 0:Open399 +(% style="color:blue" %)**0205(H) = 517 (D) = 517 cm.** 356 356 357 -1: Close 358 358 359 -= ==**2.4.8Total pulse**===402 +(% style="color:blue" %)**Object2 Distance:** 360 360 361 - Totalpulse/countingbaseondry [[contacttriggerevent>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.2SensorConfiguration2CFPORT3D4]]404 +Distance between sensor probe to the second object. (unit: cm) 362 362 363 -Range (3 Bytes) : 0x000000 ~~ 0xFFFFFF . Max: 16777215 364 364 365 -=== **2.4.9Thelastopenduration**===407 +=== 2.4.6 Timestamp === 366 366 367 -Dry Contact last open duration. 368 368 369 - Unit:min.410 +Timestamp : 0x6315537b =1662342011 370 370 371 -[[image:image-20221021111346-17.png||height="146" width="770"]] 372 372 413 +== 2.5 Downlink Payload == 373 373 374 -=== **2.4.10 Timestamp** === 375 375 376 - Time stamp:0x6315537b=1662342011416 +By default, NMDS200 prints the downlink payload to console port. 377 377 378 -Convert Unix timestamp to time 2022-9-5 9:40:11. 379 - 380 -**~ ** 381 - 382 -== **2.5 Downlink Payload** == 383 - 384 -By default, CPN01 prints the downlink payload to console port. 385 - 386 386 [[image:image-20221021111414-18.png]] 387 387 420 + 388 388 **Examples:** 389 389 390 -* **Set TDC** 423 +* (% style="color:#037691" %)**Set TDC** 391 391 392 392 If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 393 393 ... ... @@ -395,171 +395,146 @@ 395 395 396 396 Payload: 01 00 00 3C TDC=60S 397 397 398 -* **Reset** 431 +* (% style="color:#037691" %)**Reset** 399 399 400 -If payload = 0x04FF, it will reset the NS E01433 +If payload = 0x04FF, it will reset the NMDS200 401 401 402 -* **INTMOD** 435 +* (% style="color:#037691" %)**INTMOD** 403 403 404 404 Downlink Payload: 06000003, Set AT+INTMOD=3 405 405 406 -== **2.6 LED Indicator** == 407 407 408 - TheCPN01has an internalLEDwhich is to show the statusof differentstate.440 +== 2.6 LED Indicator == 409 409 410 -* When power on, CPN01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe) 411 -* Then the LED will be on for 1 second means device is boot normally. 412 -* After CPN01 join NB-IoT network. The LED will be ON for 3 seconds. 413 -* For each uplink probe, LED will be on for 500ms. 414 414 415 - ==**2.7AlarmBase onTimeout**==443 +The NMDS200 has an internal LED which is to show the status of different states. 416 416 417 -CPL01 can monitor the timeout for a status change, this feature can be used to monitor some events such as door opening too long etc. Related Parameters are: 445 +* When the device starts normally, the LED will light up for 1 second. 446 +* After NMDS200 join NB-IoT network. The LED will be ON for 3 seconds. 447 +* For each uplink probe, LED will be on for 500ms. 418 418 419 419 420 -**~1. Keep Status: Status to be monitor** 421 421 422 -Keep Status = 1: Monitor Close to Open event 423 423 424 - Keep Status=0:Monitor Opento Closeevent452 +== 2.7 Distance alarm function == 425 425 426 426 427 - **2.KeepTime:Timeout to sendanAlarm**455 +(% style="color:blue" %)**AT Command: AT+ALARM1=min,max** 428 428 429 - Range 0 ~~ 65535(0xFFFF)seconds.457 +**(% style="color:blue" %)Example 1:** 430 430 431 - Ifkeeptime=DisableAlarmBaseonTimeoutfeature.459 +AT+ ALARM1 =60,200 ~/~/ Alarm when moisture lower than 60. 432 432 433 - Ifkeeptime > 0, device will monitor the keep status event and send an alarmwhen status doesn’t change after timeout.461 +AT+ ALARM2 =min,max 434 434 435 435 436 -** ATCommand**toconfigure:464 +**(% style="color:blue" %)Example 2:** 437 437 438 - **AT+TTRIG=1,30**~-~->Whenthe **KeepStatus** changefrom connect to disconnect,and deviceremainsin disconnect status for more than 30 seconds.CPL01 will send an uplink packet, the[[Alarmbit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (thesecond bitof 1^^st^^ byte of payload) onthis uplink packet is set to1.466 +AT+ ALARM2 =200,1500 ~/~/ Alarm when temperature lower than 1500 439 439 440 -**AT+TTIG=0,0 ** ~-~-> Default Value, disable timeout Alarm. 441 441 442 -== **2.8 Set debug mode** == 443 443 444 -Feature: Enable or Disable debug mode 445 445 471 +== 2.8 Set the number of data to be uploaded and the recording time == 446 446 447 -**AT Command: AT+DEBUG** 448 448 449 - [[image:image-20221021111629-21.png]]474 +(% style="color:blue" %)**AT Command:** 450 450 451 -= =**2.9ClearFlashRecord**==476 +(% style="color:#037691" %)**AT+TR=900**(%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 452 452 453 - Feature:Clearflashstoragefor data logfeature.478 +(% style="color:#037691" %)**AT+NOUD=8**(%%)** ** ~/~/ The device uploads 0 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 454 454 455 -**AT Command: AT+CLRDTA** 456 456 457 - [[image:image-20221021111527-19.png]]481 +== 2.9 Read or Clear cached data == 458 458 459 -== ** 2.10 Set trigger mode** == 460 460 461 - ➢AT Command:AT+TTRMOD**484 +(% style="color:blue" %)**AT Command:** 462 462 463 - Feature:Setthetriggerinterruptmode.486 +(% style="color:#037691" %)**AT+CDP** (%%) ~/~/ Read cached data 464 464 465 - [[image:image-20221021111552-20.png]]488 +(% style="color:#037691" %)**AT+CDP=0** (%%) ~/~/ Clear cached data 466 466 467 - == **2.11 Set the calculateflag** ==490 +[[image:1670408172929-569.png]] 468 468 469 -Feature: Set the calculate flag 470 470 471 - **ATCommand:AT+CALCFLAG**493 +== 2.10 Firmware Change Log == 472 472 473 -[[image:image-20221021111711-22.png]] 474 474 475 - ==**2.12Setcountnumber**==496 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0>>https://www.dropbox.com/sh/hacq385w6qgnonr/AAC3D79GFGF1JdZUIzNegn2Ha?dl=0]] 476 476 477 - Feature:Manuallysethe countnumber498 +Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 478 478 479 -**AT Command: AT+SETCNT** 480 480 481 - [[image:image-20221021111748-24.png]]501 +== 2.11 Battery Analysis == 482 482 483 -== **2.13Sethenumberof data to be uploadedand the recording time**==503 +=== 2.11.1 Battery Type === 484 484 485 -➢ AT Command: 486 486 487 - AT+TR=900~/~/Theunit isseconds,andthe default istoorddata once every900 seconds.(Theminimumcanbesetto180seconds)506 +The NMDS200 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 488 488 508 +The battery is designed to last for several years depends on the actual use environment and update interval. 489 489 490 - AT+NOUD=8 ~/~/Thedevice uploads 8 sets of recorded data bydefault.Up to32 setsof record datacanbeuploaded.510 +The battery-related documents as below: 491 491 492 - ==**2.14ReadorClearcached** ==512 +* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 493 493 494 - ➢AT Command:514 +* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 495 495 496 - AT+CDP~/~/Read cached516 +* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 497 497 498 -[[image:image-20221021111 810-25.png||height="364" width="797"]]518 +[[image:image-20221021111911-26.png]] 499 499 500 500 501 - AT+CDP=0~/~/ Clear cacheddata 521 +=== 2.11.2 Power consumption Analyze === 502 502 503 -== **2.15 Firmware Change Log** == 504 504 505 -D ownloadURL&FirmwareChange log: [[https:~~/~~/www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0>>url:https://www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0]]524 +Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 506 506 507 - UpgradeInstruction:[[UpgradeFirmware>>path:#H5.1200BHowtoUpgradeFirmware]]526 +Instruction to use as below: 508 508 509 -= =**2.16Battery Analysis**==528 +(% style="color:blue" %)**Step 1: **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]] 510 510 511 -= ==**2.16.1 Battery Type**===530 +(% style="color:blue" %)**Step 2: **(%%) Open it and choose 512 512 513 - TheCPN01 battery is a combination of an 8500mAh Li/SOCI2 Battery anda Super Capacitor.The battery is none-rechargeable battery type with a lowdischargerate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.532 +* Product Model 514 514 515 - Thebattery is designed to last for several years depends on the actually use environmentand updateinterval.534 +* Uplink Interval 516 516 517 - Thebattery related documentsas below:536 +* Working Mode 518 518 519 -* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 520 -* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 521 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 538 +And the Life expectation in difference case will be shown on the right. 522 522 523 -[[image: image-20221021111911-26.png]] 540 +[[image:1666596205057-567.png]] 524 524 525 -=== **2.16.2 Power consumption Analyze** === 526 526 527 - Draginobattery powered product are all runs in Low Power mode.We have an update battery calculator which base on the measurement of the real device.User can usethis calculator to check the batterylife and calculate the battery life if want touse differenttransmit interval.543 +=== 2.11.3 Battery Note === 528 528 529 -Instruction to use as below: 530 530 531 - **Step 1: **Downlink theup-to-date DRAGINO_Battery_Life_Prediction_Table.xlsxfrom: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]546 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 532 532 533 -**Step 2: ** Open it and choose 534 534 535 -* Product Model 536 -* Uplink Interval 537 -* Working Mode 549 +=== 2.11.4 Replace the battery === 538 538 539 -And the Life expectation in difference case will be shown on the right. 540 540 541 - [[image:image-20221021111923-27.png||height="253"width="783"]]552 +The default battery pack of NMDS200 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 542 542 543 -=== **2.16.3 Battery Note** === 544 544 545 - TheLi-SICO battery is designed for small current / long period application.Itis not good to use a highcurrent, short period transmit method. The recommended minimum period for use of thisbattery is 5 minutes.If youuse a shorter periodtime to transmit LoRa, then the batterylifemay be decreased.555 += 3. Access NB-IoT Module = 546 546 547 -=== **2.16.4 Replace the battery** === 548 548 549 -The default battery pack of CPN01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 550 - 551 -= **3. Access NB-IoT Module** = 552 - 553 553 Users can directly access the AT command set of the NB-IoT module. 554 554 555 555 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 556 556 557 -[[image:image-20221021112006-28.png]] 558 558 559 - = **4. UsingtheAT Commands**=563 +[[image:image-20221118094449-6.png]] 560 560 561 -== **4.1 Access AT Commands** == 562 562 566 += 4. Using the AT Commands = 567 + 568 +== 4.1 Access AT Commands == 569 + 570 + 563 563 See this link for detail: [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 564 564 565 565 AT+<CMD>? : Help on <CMD> ... ... @@ -570,8 +570,9 @@ 570 570 571 571 AT+<CMD>=? : Get the value 572 572 573 -**General Commands** 574 574 582 +(% style="color:blue" %)**General Commands** 583 + 575 575 AT : Attention 576 576 577 577 AT? : Short Help ... ... @@ -594,125 +594,97 @@ 594 594 595 595 AT+SERVADDR : Server Address 596 596 597 -AT+TR : Get or Set record time "606 +AT+TR : Get or Set record time 598 598 608 +AT+NOUD : Get or Set the number of data to be uploaded 599 599 600 -AT+ NOUDGetorSetthenumber ofdatato be uploaded610 +AT+CDP : Read or Clear cached data 601 601 612 +AT+DEBUG: Enable or Disable debug mode 602 602 603 -AT+ CDP: ReadorClearcacheddata614 +AT+ALARM1: Get or Set alarm of distance1 604 604 616 +AT+ALARM2: Get or Set alarm of distance2 605 605 606 -AT+ DEBUG:EnableorDisabledebugmode618 +AT+GETSENSORVALUE : Returns the current sensor measurement 607 607 608 -AT+ TTRIG: Get orSetAlarm Base on Timeout620 +AT+POWERIC : Get or set the Power IC flag 609 609 610 -AT+ TTRMOD : Get or Set the trigger interrupt mode(0:falling,1:rising) 611 611 612 - AT+CALCFLAG : GetSetthecalculateflag623 +(% style="color:blue" %)**COAP Management** 613 613 614 -AT+ CLRC:Clearcurrentdoor open count625 +AT+URI : Resource parameters 615 615 616 -**COAP Management** 617 617 618 - AT+URI: Resourceparameters628 +(% style="color:blue" %)**UDP Management** 619 619 620 - **UDPManagement**630 +AT+CFM : Upload confirmation mode (only valid for UDP) 621 621 622 -AT+CFM : Upload confirmation mode (only valid for UDP) 623 623 624 -**MQTT Management** 633 +(% style="color:blue" %)**MQTT Management** 625 625 626 -AT+CLIENT 635 +AT+CLIENT : Get or Set MQTT client 627 627 628 -AT+UNAME 637 +AT+UNAME : Get or Set MQTT Username 629 629 630 -AT+PWD 639 +AT+PWD : Get or Set MQTT password 631 631 632 -AT+PUBTOPIC :Get or Set MQTT publish topic641 +AT+PUBTOPIC : Get or Set MQTT publish topic 633 633 634 -AT+SUBTOPIC :Get or Set MQTT subscription topic643 +AT+SUBTOPIC : Get or Set MQTT subscription topic 635 635 636 -**Information** 637 637 638 - AT+FDR: FactoryDataReset646 +(% style="color:blue" %)**Information** 639 639 640 -AT+ PWORD:SerialAccessPassword648 +AT+FDR : Factory Data Reset 641 641 642 - =**5.FAQ**=650 +AT+PWORD : Serial Access Password 643 643 644 -== **5.1 How to Upgrade Firmware** == 645 645 646 - Usercanupgradethe firmware for 1) bug fix, 2) new feature release.653 += 5. FAQ = 647 647 648 - Pleaseseethislink for how toupgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]655 +== 5.1 How to Upgrade Firmware == 649 649 650 -**Notice, **CPN01 **and **CPN01 **share the same mother board. They use the same connection and method to update.** 651 651 652 - ==**5.2 CanI calibrateCPN01todifferentsoiltypes?** ==658 +User can upgrade the firmware for 1) bug fix, 2) new feature release. 653 653 654 - CPN01 is calibratedforsaline-alkalisoilandloamy soil.Ifuserswantto useitfor othersoil, they cancalibratethe valueinhe IoT platformbasen the value measuredby saline-alkali soil andloamy soil. Theformula can befoundat[[thislink>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].660 +Please see this link for how to upgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]] 655 655 656 -= ** 6.Trouble Shooting**=662 +(% style="color:red" %)**Notice: **(% style="color:blue" %)**NMDS200** (%%)**and (% style="color:blue" %)LMDS200(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.** 657 657 658 -== **6.1 Connection problem when uploading firmware** == 659 659 660 - **Pleasesee: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]665 += 6. Trouble Shooting = 661 661 662 -== **6.2ATCommand inputdoesn'twork**==667 +== 6.1 Connection problem when uploading firmware == 663 663 664 -In the case if user can see the console output but can't type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn't send **ENTER** while press the send key, user need to add ENTER in their string. 665 665 666 -= ** 7.Order** =670 +(% style="color:blue" %)**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]] 667 667 668 -Part Number**:** CPN01 669 669 670 -= **8.PackingInfo**=673 +== 6.2 AT Command input doesn't work == 671 671 672 -**Package Includes**: 673 673 674 -* CPN01 NB-IoT Soil Moisture & EC Sensor x 1 675 -* External antenna x 1 676 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string. 676 676 677 -**Dimension and weight**: 678 678 679 -* Size: 195 x 125 x 55 mm 680 -* Weight: 420g 679 += 7. Order Info = 681 681 682 -= **9. Support** = 683 683 684 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 685 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 682 +Part Number:**(% style="color:blue" %) NMDS200** 686 686 687 - 688 688 685 += 8. Packing Info = 689 689 690 690 688 +(% style="color:blue" %)**Package Includes**: 691 691 690 +* NMDS200 NB-IoT Microwave Radar Distance Sensor x 1 692 692 692 += 9. Support = 693 693 694 694 695 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 695 695 697 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 696 696 697 - 698 - 699 - 700 - 701 - 702 - 703 - 704 - 705 - 706 - 707 - 708 - 709 - 710 - 711 - 712 - 713 - 714 - 715 - 716 - 717 - 718 - 699 +
- 1666596205057-567.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +179.8 KB - Content
- 1670404362039-351.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +492.6 KB - Content
- 1670405841875-916.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.1 KB - Content
- 1670405928926-116.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.7 KB - Content
- 1670406036256-101.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +181.0 KB - Content
- 1670406261143-723.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.9 KB - Content
- 1670407401682-959.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.7 KB - Content
- 1670408172929-569.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +211.8 KB - Content
- LMDS200_10.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.9 KB - Content
- image-20221023000439-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- image-20221117105556-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.3 KB - Content
- image-20221117114459-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content
- image-20221117114842-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +964.1 KB - Content
- image-20221117114937-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.1 KB - Content
- image-20221117114949-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.4 KB - Content
- image-20221117115010-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.4 KB - Content
- image-20221117142300-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +147.8 KB - Content
- image-20221117145932-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.9 KB - Content
- image-20221117150312-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.7 KB - Content
- image-20221118092935-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- image-20221118093144-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.7 KB - Content
- image-20221118093512-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.5 KB - Content
- image-20221118093658-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.7 KB - Content
- image-20221118094227-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- image-20221118094449-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.5 KB - Content
- image-20221118103445-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- image-20221118103453-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.2 KB - Content
- image-20221118103547-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.5 KB - Content
- image-20221207170748-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.1 KB - Content
- image-20221207170748-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.9 KB - Content
- image-20221207173200-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.7 KB - Content
- image-20221207173300-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.0 KB - Content
- image-20221208090742-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.7 KB - Content