Changes for page NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 17:03
Change comment:
Uploaded new attachment "image-20221023000439-3.png", version {1}
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -7,11 +7,11 @@ 7 7 8 8 == **1.1 **What is CPN01 **NB-IoT** Pulse/Contact Sensor == 9 9 10 -The Dragino CPN01 is an (% style="color:blue" %)**NB-IoT Dry Contact Sensor**(%%). It detects open/close status and uplinks the info to IoT server via N b-IoT network. User can see the dry contact status, open time, and open counts in the IoT Server.10 +The Dragino CPN01 is an (% style="color:blue" %)**NB-IoT Dry Contact Sensor**(%%). It detects open/close status and uplinks the info to IoT server via NB-IoT network. User can see the (% style="color:blue" %)**dry contact status, open time, and open counts**(%%) in the IoT Server. 11 11 12 -The CPN01 will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculates the last open duration. Users can also disable the uplink for each open/close event, instead, device can count each open event and uplink periodically.12 +The CPN01 will send periodically data every day as well as for each dry contact action. It also counts the contact open times and calculates the last open duration. Users can also disable the uplink for each Open/Close event, instead, device can count each open event and uplink periodically. 13 13 14 -CPN01 has Open-Alarm feature, user can set this feature so CPN01 will send an alarm if the contact has been open exceeds a certain time. 14 +CPN01 has** (% style="color:blue" %)Open-Alarm feature(%%)**, user can set this feature so CPN01 will send an alarm if the contact has been open exceeds a certain time. 15 15 16 16 CPN01 is designed for outdoor use. It has a weatherproof enclosure and industrial-level battery to work in low to high temperatures. 17 17 ... ... @@ -21,6 +21,7 @@ 21 21 \\To use CPN01, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that CPN01 supports. If local operator support it, user needs to get a (% style="color:blue" %)**NB-IoT SIM card**(%%) from the operator and install into CPN01 to get NB-IoT network connection. 22 22 23 23 24 + 24 24 == **1.2 Features** == 25 25 26 26 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD ... ... @@ -56,12 +56,13 @@ 56 56 57 57 == **1.4 Installation** == 58 58 59 -Connect CP L01 to an Open Close sensor like below. So it can detect theopen/close event.60 +Connect CPN01 to an Open Close sensor like below. So it can detect the Open/Close event. 60 60 61 61 [[image:image-20221021110329-1.png]] 62 62 63 -[[image:image-2022102 1110340-2.png]]64 +[[image:image-20221022234602-2.png||height="288" width="922"]] 64 64 66 + 65 65 == **1.5 Applications** == 66 66 67 67 * Open/Close Detection ... ... @@ -68,6 +68,7 @@ 68 68 * Pulse meter application 69 69 * Dry Contact Detection 70 70 73 + 71 71 == **1.6 Mechanical** == 72 72 73 73 [[image:image-20221021110415-3.png]] ... ... @@ -78,24 +78,22 @@ 78 78 79 79 === **1.7.1 Pin Definition** === 80 80 81 -CP L01 is pre-configured to connect to two external wires. The other pins are not used. If user wants to know more about other pins, please refer to the usermanualof LSN50v2 at:[[https:~~/~~/www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0>>url:https://www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0]]84 +CPN01 is pre-configured to connect to two external wires. The other pins are not used. If user wants to know more about other pins, please refer to the **[[LSN50v2 User Manual>>doc:Main.User Manual for LoRaWAN End Nodes.LSN50 & LSN50-V2 - LoRaWAN Sensor Node User Manual.WebHome]]**. 82 82 86 + 83 83 === **1.7.2 Jumper JP2(Power ON/OFF)** === 84 84 85 - 86 86 Power on Device when putting this jumper. 87 87 88 88 89 - 90 90 === **1.7.3 BOOT MODE / SW1** === 91 91 92 92 93 -1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run.95 +1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. The firmware won't run. 94 94 95 -2) Flash: work mode, the device starts to work and send out console output for further debug 97 +2) Flash: working mode, the device starts to work for NB-IoT connection and sends out console output for further debugging. 96 96 97 97 98 - 99 99 === **1.7.4 Reset Button** === 100 100 101 101 ... ... @@ -106,11 +106,12 @@ 106 106 === **1.7.5 LED** === 107 107 108 108 109 - Itwillflash:110 +The LED will blink when : 110 110 111 111 1. Boot the device in flash mode 112 112 1. Send an uplink packet 113 113 115 + 114 114 = **2. Use CPN01 to communicate with IoT Server** = 115 115 116 116 == **2.1 How it works** ==
- image-20221022234529-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.3 KB - Content
- image-20221022234602-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.7 KB - Content
- image-20221023000439-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content