Changes for page NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 17:03
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 41 added, 0 removed)
- 1666596205057-567.png
- 1670404362039-351.png
- 1670405841875-916.png
- 1670405928926-116.png
- 1670406036256-101.png
- 1670406261143-723.png
- 1670407401682-959.png
- 1670408172929-569.png
- 1670471530120-960.png
- 1670471559211-638.png
- 1670471584490-640.png
- 1670471613823-833.png
- LMDS200_10.jpg
- image-20221022234529-1.png
- image-20221022234602-2.png
- image-20221023000439-3.png
- image-20221117105556-1.png
- image-20221117114459-2.png
- image-20221117114842-3.png
- image-20221117114937-4.png
- image-20221117114949-5.png
- image-20221117115010-6.png
- image-20221117142300-1.png
- image-20221117145932-2.png
- image-20221117150312-3.png
- image-20221118092935-1.png
- image-20221118093144-2.png
- image-20221118093512-3.png
- image-20221118093658-4.png
- image-20221118094227-5.png
- image-20221118094449-6.png
- image-20221118103445-7.png
- image-20221118103453-8.png
- image-20221118103547-9.png
- image-20221207170748-1.png
- image-20221207170748-2.png
- image-20221207173200-3.png
- image-20221207173300-4.png
- image-20221208090742-1.png
- image-20221209090938-1.png
- image-20221212171610-1.jpeg
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 - CPN01- NB-IoTOutdoorOpen/CloseDryContactSensor User Manual1 +NMDS200 - NB-IoT Microwave Radar Distance Sensor User Manual - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. David1 +XWiki.Xiaoling - Content
-
... ... @@ -1,36 +1,75 @@ 1 1 (% style="text-align:center" %) 2 -[[image: http://wiki.dragino.com/xwiki/bin/download/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/WebHome/1652856952171-363.png?rev=1.1||alt="1652856952171-363.png"]]2 +[[image:LMDS200_10.jpg||height="572" width="572"]] 3 3 4 4 5 -**~1. Introduction** 6 6 7 -**1.1 **What is CPN01 **NB-IOT** Pulse/Contact Sensor 8 8 9 -The Dragino CPL01 is a **NB-IOT Contact Sensor**. It detects open/close status and uplink to IoT server via LoRaWAN network. user can see the dry contact status, open time, open counts in the IoT Server. 10 10 11 - TheCPL01 willsend periodically data everyday as well as foreachdry contact action. It also counts the contact open times and calculate last openduration. Usercanalsodisable the uplink for each open/close event, instead, device can count each open event and uplink periodically.8 +(% style="display:none" %) (%%) 12 12 13 -CPL01 has the open alarm feature, user can set this feature so device will send Alarm if the contact has been open for a certain time. 14 14 15 -CPL01 is designed for outdoor use. It has a weatherproof enclosure and industrial level battery to work in low to high temperatures. 16 16 17 -NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity and spectrum efficiency, especially in deep coverage. 18 -\\CPN01 supports different uplink methods include **TCP,MQTT,UDP and CoAP **for different application requirement. 19 -\\CPN01 is powered by **8500mAh Li-SOCI2 battery**, It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 20 -\\To use CPN01, user needs to check if there is NB-IoT coverage in local area and with the bands CPN01 supports. If the local operate support it, user needs to get a **NB-IoT SIM card** from local operator and install CPN01 to get NB-IoT network connection 21 21 22 - 23 23 14 +**Table of Contents:** 24 24 25 - **1.2 Features**16 +{{toc/}} 26 26 18 + 19 + 20 + 21 + 22 + 23 + 24 + 25 + 26 += 1. Introduction = 27 + 28 +== 1.1 What is NMDS200 NB-IoT Microwave Radar Distance Sensor == 29 + 30 + 31 +((( 32 +The Dragino NMDS200 is a(% style="color:blue" %)** NB-IoT Microwave Radar distance sensor**(%%). It uses (% style="color:blue" %)**24Ghz Microwave**(%%) to detect the distance between sensor and different objects. Compare vs ultrasonic or Lidar measurement method, Microwave Radar is (% style="color:blue" %)**more reliable for condensation / dusty environment**(%%). It can sense correct distance even there is water or thick dust on top of the sensor. 33 +))) 34 + 35 +((( 36 +The NMDS200 can be applied to scenarios such as horizontal distance measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, etc. 37 +))) 38 + 39 +((( 40 +NMDS200 can (% style="color:blue" %)**measure two distances**(%%): the closest object and next object behind the closest one. 41 +))) 42 + 43 +((( 44 +NMDS200 (% style="color:blue" %)**supports Alarm Feature**(%%), user can set the NMDS200 to uplink data in a short interval when the distance is out of configured range. 45 +))) 46 + 47 +((( 48 +NarrowBand-Internet of Things (NB-IoT) is a (% style="color:blue" %)**standards-based low power wide area (LPWA) technology**(%%) developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity, and spectrum efficiency, especially in deep coverage. 49 +))) 50 + 51 +((( 52 +NMDS200 (% style="color:blue" %)**supports different uplink**(%%) methods including (% style="color:blue" %)**TCP, MQTT, UDP, and CoAP**(%%) for different application requirements. 53 +))) 54 + 55 +((( 56 +NMDS200 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**,(%%) It is designed for long-term use of up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method) 57 +))) 58 + 59 +((( 60 +To use NMDS200, user needs to check if there is NB-IoT coverage in the field and with the Nb-IoT bands that NMDS200 supports. If local operator support it, user needs to get a** (% style="color:blue" %)NB-IoT SIM card(%%)** from the operator and install into NMDS200 to get NB-IoT network connection. 61 +))) 62 + 63 + 64 +== 1.2 Features == 65 + 66 + 27 27 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD 28 -* Open/Close detect 29 -* Open/Close statistics 68 +* Short uplink interval for Distance Alarm 30 30 * Monitor Battery Level 31 -* Uplink on periodicallyand open/close event70 +* Microwave Radar for distance detection 32 32 * Datalog feature 33 -* Uplink onperiodically72 +* Uplink periodically 34 34 * Downlink to change configure 35 35 * Wall Mountable 36 36 * Outdoor Use ... ... @@ -37,524 +37,483 @@ 37 37 * Ultra-Low Power consumption 38 38 * AT Commands to change parameters 39 39 * Micro SIM card slot for NB-IoT SIM 40 -* 8500mAh Battery for long 79 +* 8500mAh Battery for long-term use 41 41 42 -**1.3 Specification** 43 43 44 -**Common DC Characteristics:** 45 45 46 -* Supply Voltage: 2.1v ~~ 3.6v 47 -* Operating Temperature: -40 ~~ 85°C 83 +== 1.3 Radar probe specification == 48 48 49 -**NB-IoT Spec:** 50 50 51 -* - B1 @H-FDD: 2100MHz 52 -* - B3 @H-FDD: 1800MHz 53 -* - B8 @H-FDD: 900MHz 54 -* - B5 @H-FDD: 850MHz 55 -* - B20 @H-FDD: 800MHz 56 -* - B28 @H-FDD: 700MHz 86 +* Measuring Method: FMCW 87 +* Frequency: 24.000 ~~ 24.500 GHz 88 +* Measurement output power: 6dBm 89 +* Measure range: 0.5 ~~ 20m 90 +* Accuracy: ±0.1m 91 +* Resolution: 0.01m 92 +* Horizontal Angel: 78° 93 +* Vertical Angel: 23° 57 57 58 -**1.4 Installation** 59 59 60 -Connect CPL01 to an Open Close sensor like below. So it can detect the open/close event. 61 61 62 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image001.png]] [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image002.png]]97 +== 1.4 Storage Temperature == 63 63 64 -**1.5 Applications** 65 65 66 -* Open/Close Detection 67 -* Pulse meter application 68 -* Dry Contact Detection 100 + -40°C to +85°C 69 69 70 -**1.6 Mechanical** 71 71 72 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image003.png]]103 +== 1.5 Applications == 73 73 74 -**~ 1.7 Pin Definitions and Switch** 75 75 76 -[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image004.png]] 106 +* Horizontal distance measurement 107 +* Liquid level measurement 108 +* Parking management system 109 +* Object proximity and presence detection 110 +* Intelligent trash can management system 111 +* Robot obstacle avoidance 112 +* Automatic control 113 +* Sewer 114 +* Bottom water level monitoring 77 77 78 -**1.7.1 Pin Definition** 79 79 80 -CPL01 is pre-configured to connect to two external wires. The other pins are not used. If user wants to know more about other pins, please refer to the user manual of LSN50v2 at: [[https:~~/~~/www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0>>url:https://www.dropbox.com/sh/djkxs7mr17y94mi/AABVlWbM9uzK9OA3mXyAT10Za?dl=0]] 81 81 82 - **1.7.2Jumper JP2(PowerON/OFF)**118 +== 1.6 Specification == 83 83 84 84 85 - Power on Devicewhen puttingthisjumper.121 +(% style="color:blue" %)**Common DC Characteristics:** 86 86 123 +* Supply Voltage: 2.1v ~~ 3.6v 124 +* Operating Temperature: 0 ~~ 70°C 87 87 126 +(% style="color:blue" %)**NB-IoT Spec:** 88 88 89 -**1.7.3 BOOT MODE / SW1** 128 +* B1 @H-FDD: 2100MHz 129 +* B3 @H-FDD: 1800MHz 130 +* B8 @H-FDD: 900MHz 131 +* B5 @H-FDD: 850MHz 132 +* B20 @H-FDD: 800MHz 133 +* B28 @H-FDD: 700MHz 90 90 91 91 92 -1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run. 93 93 94 - 2)Flash:work mode, the devicestarts to workand send outconsoleoutput for further debug137 +== 1.7 Installation == 95 95 96 96 140 +Sensor measure direction and angle is as below. When install the sensor, please make sure the sensor direct to object. 97 97 98 -**1.7.4 Reset Button** 99 99 143 +[[image:image-20221207170748-1.png]] 100 100 101 -Press to reboot the device. 102 102 146 + [[image:image-20221207170748-2.png||height="345" width="634"]] 103 103 104 104 105 - **1.7.5LED**149 +== 1.8 Pin Definitions and Switch == 106 106 107 107 108 - It will flash:152 +[[image:1670404362039-351.png]] 109 109 110 -1. Boot the device in flash mode 111 -1. Send an uplink packet 112 112 155 += 2. Use NMDS200 to communicate with IoT Server = 113 113 114 - **2.Use CPN01 tocommunicatewith IoT Server**157 +== 2.1 How it works == 115 115 116 -**2.1 How it works** 117 117 118 -The CPN01 is equipped with a NB-IoTmodule, the pre-loaded firmware inCPN01 will getenvironment data from sensors and send the value to local NB-IoT networkvia the NB-IoT module. The NB-IoT network will forward this value to IoT server via the protocol defined byCPN01.160 +The NB-IoT network will forward this value to IoT server via the protocol defined by NMDS200. 119 119 120 -The diagram below shows the working flow in default firmware of CPN01:162 +The diagram below shows the working flow in the default firmware of NMDS200: 121 121 122 -[[image: file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image005.png||alt="说明: image-20220708101605-2.png"]]164 +[[image:image-20221021110615-5.png||height="996" width="492"]] 123 123 124 -**2.2 Configure the CPN01** 125 125 126 - **2.2.1Test Requirement**167 +== 2.2 Configure NMDS200 == 127 127 128 -To use CPN01 in your city, make sure meet below requirements: 129 129 130 -* Your local operator has already distributed a NB-IoT Network there. 131 -* The local NB-IoT network used the band that CPN01 supports. 170 +To use NMDS200 in your city, make sure to meet below requirements: 171 + 172 +* Your local operator has already distributed an NB-IoT Network. 173 +* The local NB-IoT network used the band that NMDS200 supports. 132 132 * Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 133 133 134 -Below figure shows our testing structure. CPN01will use CoAP(120.24.4.116:5683) or raw UDP(120.24.4.116:5601) or MQTT(120.24.4.116:1883)or TCP(120.24.4.116:5600)protocol to send data to the test server176 +Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. The NMDS200 will use** (% style="color:red" %)CoAP(120.24.4.116:5683)(%%)** or raw (% style="color:red" %)**UDP(120.24.4.116:5601) **(%%)or (% style="color:red" %)**MQTT(120.24.4.116:1883) **(%%)or (% style="color:red" %)**TCP(120.24.4.116:5600)protocol**(%%) to send data to the test server. 135 135 136 - 178 +[[image:image-20221209090938-1.png]] 137 137 138 -**2.2.2 Insert SIM card** 139 139 181 +=== 2.2.1 Insert NB-IoT SIM card === 182 + 183 + 140 140 Insert the NB-IoT Card get from your provider. 141 141 142 -User need to take out the NB-IoT module and insert the SIM card like below: 186 +User needs to take out the NB-IoT module and insert the SIM card like below: 143 143 144 -[[image: file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image006.png||alt="说明:1657249468462-536.png"]] 188 +[[image:image-20221021110745-6.png]] 145 145 146 -**2.2.3 Connect USB – TTL to CPN01 to configure it** 147 147 148 - UserneedtoconfigureCPN01 via serial port to set the **Server Address** / **Uplink Topic** to definewhere and how-to uplink packets.CPN01 support AT Commands, user can use aUSBtoTTLadapter toconnect to CPN01anduse AT Commands toconfigure it,as below.191 +=== 2.2.2 Connect USB – TTL to NMDS200 and configure it === 149 149 150 -**Connection:** 151 151 152 - USB TTL GND<~-~-~-~->GND194 +User need to configure NMDS200 via serial port to set the (% style="color:red" %)**Server Address** / **Uplink Topic**(%%) to define where and how-to uplink packets. NMDS200 support AT Commands, user can use a USB to TTL adapter to connect to NMDS200 and use AT Commands to configure it, as below. 153 153 154 - USBTTL TXD <~-~-~-~-> UART_RXD196 +(% style="color:blue" %)**Connection:** 155 155 156 - USB TTL RXD <~-~-~-~->UART_TXD198 +(% style="background-color:yellow" %)** USB TTL GND <~-~-~-~-> GND** 157 157 200 +(% style="background-color:yellow" %)** USB TTL TXD <~-~-~-~-> UART_RXD** 201 + 202 +(% style="background-color:yellow" %)** USB TTL RXD <~-~-~-~-> UART_TXD** 203 + 204 + 158 158 In the PC, use below serial tool settings: 159 159 160 -* Baud: **9600** 161 -* Data bits:** 8** 162 -* Stop bits: **1** 163 -* Parity: **None** 164 -* Flow Control: **None** 207 +* Baud: (% style="color:red" %)**9600** 165 165 166 - Makesuretheswitch isin FLASH position, then power on device byconnecting the jumper on CPN01. CPN01 will output system info once power on as below, we can enterthe **password:12345678**to access AT Command input.209 +* Data bits:** (% style="color:red" %)8(%%)** 167 167 168 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image007.png]]211 +* Stop bits: (% style="color:red" %)**1** 169 169 170 -* *Note:the validATCommandscanbefoundat: **[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]213 +* Parity: (% style="color:red" %)**None** 171 171 172 -* *2.2.4UseCoAP protocoltouplink data**215 +* Flow Control: (% style="color:red" %)**None** 173 173 174 - **Note: if you don't haveCoAPserver,you can referthislinktosetupone:**[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]217 +Make sure the switch is in FLASH position, then power on NMDS200 by connecting the (% style="color:orange" %)**Yellow Jumper**(%%). 175 175 176 - **Usebelow commands:**219 +[[image:image-20221021110817-7.png]] 177 177 178 -* **AT+PRO=1** ~/~/ Set to use CoAP protocol to uplink 179 -* **AT+SERVADDR=120.24.4.116,5683 ** ~/~/ to set CoAP server address and port 180 -* **AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** ~/~/Set COAP resource path 221 +NMDS200 will output system info once powered on as below, we can enter the **password: 12345678** to access AT Command input. 181 181 182 -For parameter description, please refer to AT command set 183 183 184 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image008.png]]224 +(% style="color:red" %)**Note: the valid AT Commands can be found at: **(%%)[[**https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0**>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 185 185 186 -After configure the server address and **reset the device** (via AT+ATZ ), CPN01 will start to uplink sensor values to CoAP server. 187 187 188 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image009.png]]227 +=== 2.2.3 Use CoAP protocol to uplink data === 189 189 190 -**2.2.5 Use UDP protocol to uplink data(Default protocol)** 191 191 192 - This feature is supportedsincefirmwaresion1.0.1230 +(% style="color:red" %)**Note: if you don't have a CoAP server, you can refer this link to set up a CoAP server: **(%%)[[**http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 193 193 194 -* **AT+PRO=2 ** ~/~/ Set to use UDP protocol to uplink 195 -* **AT+SERVADDR=120.24.4.116,5601 ** ~/~/ to set UDP server address and port 196 -* **AT+CFM=1 ** ~/~/If the server does not respond, this command is unnecessary 197 197 198 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image010.png]]233 +(% style="color:blue" %)**Use below commands in NMDS200:** 199 199 200 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image011.png||alt="说明: 1657249930215-289.png"]]235 +* (% style="color:#037691" %)**AT+PRO=1** (%%) ~/~/ Set to use CoAP protocol to uplink 201 201 202 - 237 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5683 ** (%%) ~/~/ Set CoAP server address and port 203 203 204 -* *2.2.6Use MQTT protocol to uplinkdata**239 +* (% style="color:#037691" %)**AT+URI=0,0,11,2,"mqtt" ** (%%) ~/~/ Set CoAP resource path 205 205 206 - This featureis supportedsincefirmwareversionv110241 +For parameter description, please refer to AT command set 207 207 208 -* **AT+PRO=3 ** ~/~/Set to use MQTT protocol to uplink 209 -* **AT+SERVADDR=120.24.4.116,1883 ** ~/~/Set MQTT server address and port 210 -* **AT+CLIENT=CLIENT ** ~/~/Set up the CLIENT of MQTT 211 -* **AT+UNAME=UNAME **~/~/Set the username of MQTT 212 -* **AT+PWD=PWD **~/~/Set the password of MQTT 213 -* **AT+PUBTOPIC=NSE01_PUB **~/~/Set the sending topic of MQTT 214 -* **AT+SUBTOPIC=NSE01_SUB ** ~/~/Set the subscription topic of MQTT 243 +[[image:1670471530120-960.png||height="647" width="674"]] 215 215 216 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image012.png]] 217 217 218 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image013.png]]246 +After configuring the server address and (% style="color:green" %)**reset NMDS200**(%%) (via AT+ATZ ), NMDS200 will start to uplink sensor values to the CoAP server. 219 219 220 - 248 +[[image:1670405841875-916.png]] 221 221 222 -MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 223 223 224 - **2.2.7UseTCP protocol to uplink data**251 +=== 2.2.4 Use UDP protocol to uplink data(Default protocol) === 225 225 226 -This feature is supported since firmware version v110 227 227 228 -* **AT+PRO=4 ** ~/~/ Set to use TCP protocol to uplink 229 -* **AT+SERVADDR=120.24.4.116,5600 ** ~/~/ to set TCP server address and port 254 +(% style="color:blue" %)**AT Commands:** 230 230 231 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image014.png]]256 +* (% style="color:#037691" %)**AT+PRO=2 ** (%%) ~/~/ Set to use UDP protocol to uplink 232 232 233 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image015.png||alt="说明:1657250255956-604.png"]]258 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5601 ** (%%) ~/~/ Set UDP server address and port 234 234 260 +* (% style="color:#037691" %)**AT+CFM=1 ** (%%) ~/~/ If the server does not respond, this command is unnecessary 261 + 262 + [[image:1670471559211-638.png]] 263 + 264 + 265 +[[image:image-20221021111033-11.png||height="241" width="576"]] 266 + 235 235 236 236 237 - **2.2.8ChangeUpdateInterval**269 +=== 2.2.5 Use MQTT protocol to uplink data === 238 238 239 -User can use below command to change the **uplink interval**. 240 240 241 - ***AT+TDC=600** ~/~/ Set Update Interval to 600s272 +(% style="color:blue" %)**AT Commands:** 242 242 243 -** NOTE:**274 +* (% style="color:#037691" %)**AT+PRO=3 ** (%%) ~/~/ Set to use MQTT protocol to uplink 244 244 245 -* *~1.Bydefault,thedevicewillsendanuplinkmessageevery1hour.**276 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,1883 ** (%%) ~/~/ Set MQTT server address and port 246 246 247 -* *2.3UplinkPayload**278 +* (% style="color:#037691" %)**AT+CLIENT=CLIENT ** (%%) ~/~/ Set up the CLIENT of MQTT 248 248 249 - Inthismode, uplink payload includes 87bytesintotalby default.280 +* (% style="color:#037691" %)**AT+UNAME=UNAME **(%%)** **~/~/ Set the username of MQTT 250 250 251 - Eachtimethedevice uploadsadatapackage,8setsofrecordeddatawillbeattached.Upto32setsofrecordeddatacan beuploaded.282 +* (% style="color:#037691" %)**AT+PWD=PWD **(%%)** **~/~/ Set the password of MQTT 252 252 253 -|**Size(bytes)**|**8**|**2**|**2**|**1**|**1**|**1**|**2**|**2**|4 254 -|**Value**|[[Device ID>>path:#H2.4.1A0A0DeviceID]]|[[Ver>>path:#H2.4.2A0VersionInfo]]|[[BAT>>path:#H2.4.3A0BatteryInfo]]|[[Signal Strength>>path:#H2.4.4A0SignalStrength]]|MOD|[[Interrupt>>path:#H2.4.8A0DigitalInterrupt]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|Time stamp 284 +* (% style="color:#037691" %)**AT+PUBTOPIC=NSE01_PUB **(%%)** **~/~/ Set the sending topic of MQTT 255 255 286 +* (% style="color:#037691" %)**AT+SUBTOPIC=NSE01_SUB ** (%%) ~/~/ Set the subscription topic of MQTT 256 256 257 -|2|2|4|8 group 258 -|[[Soil Temperature>>path:#H2.4.6A0SoilTemperature]]|[[Soil P>>path:#H2.4.7A0SoilConductivity28EC29]]H|Time stamp|... 288 + [[image:1670471584490-640.png]] 259 259 260 -If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the CPN01 uplink data. 261 261 262 -[[image: file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image016.png]]291 +[[image:1670405928926-116.png]] 263 263 264 - The payload is ASCII string, representative same HEX:293 + 265 265 266 - 0xf86778705021331700640c7817010001000000090000026315537b0100000b02000002663510fed0100000e0200000263510f39010000000000000063510e85010000000000000063510d2e010000000000000063510c7a010000000000000063510bc6010000000000000063510954010000000000000063510882where:295 +MQTT protocol has a much higher power consumption compare with UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval. 267 267 268 -* **Device ID: 0x f867787050213317 = f867787050213317** 269 -* **Version: 0x0064=100=1.0.0** 270 270 271 -* **BAT: 0x0c78 = 3192 mV = 3.192V** 272 -* **Singal: 0x17 = 23** 273 -* **Mod: 0x01 = 1** 274 -* **Calculate Flag: 0x00= 0** 275 -* **Contact Status: 0x00= 0** 276 -* **Alarm:0x00 =0** 277 -* **Total pulse:0x09 =0** 278 -* **The last open duration:0x02 =2** 279 -* **Time stamp : 0x6315537b =1662342011** 280 -* **Contact Status, Total pulse, Calculate Flag, The last open duration ,Time stamp : 0100000b0200002663510fed** 281 -* **8 sets of recorded data: Contact Status, Total pulse, Calculate Flag, The last open duration ,Time stamp : 0100000e0200002663510f39,.......** 298 +=== 2.2.6 Use TCP protocol to uplink data === 282 282 283 -**2.4 Payload Explanation and Sensor Interface** 284 284 285 - **2.4.1 DeviceID**301 +(% style="color:blue" %)**AT Commands:** 286 286 287 - Bydefault,theDeviceIDequaltothelast15 bitsofIMEI.303 +* (% style="color:#037691" %)**AT+PRO=4 ** (%%) ~/~/ Set to use TCP protocol to uplink 288 288 289 - Usercanuse **AT+DEUI**tosetDeviceID305 +* (% style="color:#037691" %)**AT+SERVADDR=120.24.4.116,5600 ** (%%) ~/~/ Set TCP server address and port 290 290 291 - **Example:**307 + [[image:1670471613823-833.png]] 292 292 293 -AT+DEUI=868411056754138 294 294 295 - The Device ID is stored inanone-erase area, Upgradethe firmwareor run AT+FDR won't erase Device ID.310 +[[image:image-20221021111131-15.png]] 296 296 297 - **2.4.2 Version Info**312 + 298 298 299 - Specifythesoftwareversion: 0x64=100, means firmwareversion 1.00.314 +=== 2.2.7 Change Update Interval === 300 300 301 -For example: 0x00 64 : this device is CPN01 with firmware version 1.0.0. 302 302 303 - **2.4.3BatteryInfo**317 +User can use below command to change the (% style="color:blue" %)**uplink interval**. 304 304 305 - CheckthebatteryvoltageforCPN01.319 +* (% style="color:#037691" %)**AT+TDC=7200 ** (%%) ~/~/ Set Update Interval to 7200s (4 hours) 306 306 307 - Ex1:0x0B45=2885mV321 +(% style="color:red" %)**NOTE:** 308 308 309 - Ex2:0x0B49=2889mV323 +1. By default, the device will send an uplink message every 4 hour. 310 310 311 -**2.4.4 Signal Strength** 312 312 313 - NB-IoTNetworksignalStrength.326 +== 2.3 Uplink Payload == 314 314 315 -**Ex1: 0x1d = 29** 316 316 317 - **0**-113dBmorless329 +The uplink payload includes 23 bytes in total by default. 318 318 319 - **1**-111dBm331 +Each time the device uploads a data package. The user can use the AT+NOUD command to upload the recorded data.Up to 32 sets of recorded data can be uploaded. 320 320 321 -**2...30** -109dBm... -53dBm 322 322 323 -**31** -51dBm or greater 334 +(% border="1" cellspacing="5" style="background-color:#ffffcc; color:green; width:450px" %) 335 +|=(% scope="row" style="width: 60px;" %)**Size(bytes)**|(% style="width:50px" %)**8**|(% style="width:30px" %)**2**|(% style="width:30px" %)**2**|(% style="width:75px" %)**1**|(% style="width:30px" %)**1**|(% style="width:50px" %)**1**|(% style="width:60px" %)**2**|(% style="width:60px" %)**2** 336 +|=(% style="width: 93px;" %)**Value**|(% style="width:67px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:40px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:45px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:54px" %)MOD|(% style="width:62px" %)Exit flag|(% style="width:94px" %) [[Distance 1>>||anchor="H2.4.5A0Distance"]] |(% style="width:93px" %) [[Distance 2>>||anchor="H2.4.5A0Distance"]] 324 324 325 -**99** Not known or not detectable 338 +(% border="1" style="background-color:#ffffcc; color:green; width:429px" %) 339 +|(% style="width:60px" %)**4**|(% style="width:60px" %)**2**|(% style="width:60px" %)**2**|(% style="width:60px" %)**4**|(% style="width:100px" %)((( 340 +**1-32 group** 341 +))) 342 +|(% style="width:98px" %)[[Time stamp>>||anchor="H2.4.6A0Timestamp"]]| Distance 1 | Distance 2|(% style="width:67px" %)Time stamp|(% style="width:100px" %)... 326 326 327 - **2.4.5CalculateFlag**344 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NMDS200 uplink data. 328 328 329 - The calculate flagis a user define field, IoT server can use this filed to handle differentmeter with different pulse factor. Forexample, if there are100water meters, meter1~~50 are1liter/pulse and meter 51 ~~ 100 has 1.5 liter/pulse.346 +[[image:1670406261143-723.png]] 330 330 331 -User can set calculate flag to 1 for meter 1~~50 and 2 for meter 51 ~~ 100, So IoT Server can use this field for calculation. 332 332 333 - Default value: 0.349 +The payload is ASCII string, representative same HEX: **0x (% style="color:red" %)__f867787050471071__ (% style="color:blue" %)__0064__ (% style="color:green" %) __0cc3__(% style="color:#00b0f0" %) 0__9__(% style="color:#7030a0" %) __01__(% style="color:#0020b0" %) __00__ (% style="color:#420042" %)__00ef__(% style="color:#660066" %) (% style="color:#663300" %)__013d__ (% style="color:#d60093" %)__6390453d__(%%)** 334 334 335 - Range(6 bits):(b)000000 ~~ (b) 111111351 +**where:** 336 336 337 -* *2.4.6Alarm**353 +* (% style="color:#037691" %)**Device ID:**(%%) 0x f867787050471071 = f867787050471071 338 338 339 - See [[AlarmBaseon Timeout>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H3.5AlarmBaseonTimeout]]355 +* (% style="color:#037691" %)**Version:**(%%) 0x0064=100=1.0.0 340 340 341 -* *2.4.7ContactStatus**357 +* (% style="color:#037691" %)**BAT :**(%%) 0x0cc3 = 3267 mV = 3.267V 342 342 343 - 0:Open359 +* (% style="color:#037691" %)**Singal: **(%%)0x09 = 9 344 344 345 - 1:Close361 +* (% style="color:#037691" %)**Mod:**(%%) 0x01 = 1 346 346 347 -* *2.4.8Totalpulse**363 +* (% style="color:#037691" %)**Exit flag: **(%%)0x00 =0 348 348 349 - Totalpulse/countingbase on dry [[contact trigger event>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.2SensorConfiguration2CFPORT3D4]]365 +* (% style="color:#037691" %)**Distance 1: **(%%)0x00ef=239 350 350 351 - Range(3Bytes) : 0x000000~~ 0xFFFFFF . Max:16777215367 +* (% style="color:#037691" %)**Distance 2: **(%%)0x013d =317 352 352 353 -* *2.4.9helastopenduration**369 +* (% style="color:#037691" %)**Timestamp: **(%%)0x6390453d =1670399293 (Unix Time) 354 354 355 - DryContactlastpenduration.371 +== 2.4 Payload Explanation and Sensor Interface == 356 356 357 - Unit:min.373 +=== 2.4.1 Device ID === 358 358 359 -[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image017.png]] 360 360 376 +By default, the Device ID is equal to the last 15 bits of IMEI. 361 361 362 - **2.4.10Timestamp**378 +User can use (% style="color:blue" %)**AT+DEUI** (%%)to set Device ID 363 363 364 - Time stamp0x6315537b =1662342011380 +**Example:** 365 365 366 - ConvertUnix timestamp to time 2022-9-59:40:11.382 +AT+DEUI=868411056754138 367 367 368 - **~**384 +The Device ID is stored in a non-erase area, Upgrade the firmware or run AT+FDR won't erase the Device ID. 369 369 370 -**2.5 Downlink Payload** 371 371 372 - Bydefault,CPN01 printsthe downlinkpayload to consoleport.387 +=== 2.4.2 Version Info === 373 373 374 -[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image018.png||alt="说明: image-20220708133731-5.png"]] 375 375 376 - **Examples:**390 +Specify the software version: 0x64=100, which means firmware version 1.00. 377 377 378 - ***SetTDC**392 +For example 0x00 64 : This device is NMDS200 with firmware version 1.0.0. 379 379 380 -If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 381 381 382 - Payload:01 00 00 1E TDC=30S395 +=== 2.4.3 Battery Info === 383 383 384 -Payload: 01 00 00 3C TDC=60S 385 385 386 - ***Reset**398 +Check the battery voltage for NMDS200. 387 387 388 - Ifpayload =0x04FF,itwill reset the NSE01400 +Ex1: 0x0B45 = 2885mV 389 389 390 - ***INTMOD**402 +Ex2: 0x0B49 = 2889mV 391 391 392 -Downlink Payload: 06000003, Set AT+INTMOD=3 393 393 394 - **2.6LED Indicator**405 +=== 2.4.4 Signal Strength === 395 395 396 -The CPN01 has an internal LED which is to show the status of different state. 397 397 398 -* When power on, CPN01 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe) 399 -* Then the LED will be on for 1 second means device is boot normally. 400 -* After CPN01 join NB-IoT network. The LED will be ON for 3 seconds. 401 -* For each uplink probe, LED will be on for 500ms. 408 +NB-IoT Network signal Strength. 402 402 403 - **2.7** Alarm Basen Timeout410 +(% style="color:blue" %)**Ex1: 0x1d = 29** 404 404 405 - CPL01can monitor thetimeout forastatuschange,thisfeaturecanbeusedtomonitorsome events such as dooropening toolongetc. Related Parametersare:412 +(% style="color:#037691" %)**0** (%%) -113dBm or less 406 406 414 +(% style="color:#037691" %)**1** (%%) -111dBm 407 407 408 - **~1.Keep Status: Status to bemonitor**416 +(% style="color:#037691" %)**2...30** (%%) -109dBm... -53dBm 409 409 410 - KeepStatus1: MonitorClosetoOpen event418 +(% style="color:#037691" %)**31** (%%) -51dBm or greater 411 411 412 - KeepStatus0:MonitorOpentoCloseevent420 +(% style="color:#037691" %)**99** (%%) Not known or not detectable 413 413 414 414 415 - **2.Keep Time: Timeout tosendanAlarm**423 +=== 2.4.5 Distance === 416 416 417 -Range 0 ~~ 65535(0xFFFF) seconds. 418 418 419 - If keep time = 0, DisableAlarm Base on Timeout feature.426 +[[image:1670407401682-959.png]] 420 420 421 -If keep time > 0, device will monitor the keep status event and send an alarm when status doesn’t change after timeout. 422 422 429 +(% style="color:blue" %)**Object1 Distance:** 423 423 424 - **AT Command**toconfigure:431 +Distance between sensor probe to the first object. (unit: cm) 425 425 426 - **AT+TTRIG=1,30**~-~-> Whenthe**KeepStatus** change fromconnectto disconnect,and deviceremains in disconnectstatusformorethan 30 seconds.CPL01 willsendanuplink packet,the[[Alarmbit>>url:http://wiki.dragino.com/xwiki/bin/view/Main/User%20Manual%20for%20LoRaWAN%20End%20Nodes/CPL01%20LoRaWAN%20Outdoor%20PulseContact%20%20Sensor%20Manual/#H2.3.3Real-TimeOpen2FCloseStatus2CUplinkFPORT3D2]] (thesecondbitof 1^^st^^byteof payload) on this uplink packet isset to 1.433 +For example, if the data you get from the register is 0x02 0x05, the distance between the sensor and the measured object is 427 427 428 -** AT+TTIG=0,0**~-~->DefaultValue,disabletimeout Alarm.435 +(% style="color:blue" %)**0205(H) = 517 (D) = 517 cm.** 429 429 430 -**2.8** Set debug mode 431 431 432 - Feature:EnableorDisabledebug mode438 +(% style="color:blue" %)**Object2 Distance:** 433 433 440 +Distance between sensor probe to the second object. (unit: cm) 434 434 435 -**AT Command: AT+DEBUG** 436 436 437 -|**Command Example**|**Function**|**Response** 438 -|AT+DEBUG =0|Disable debug mode to 0|OK 439 -|AT+ DEBUG =1|Enable debug mode to 1|OK 443 +=== 2.4.6 Timestamp === 440 440 441 -== 2.9 Clear Flash Record == 442 442 443 - Feature: Clear flash storagefordatalog feature.446 +Timestamp : 0x6315537b =1662342011 444 444 445 -**AT Command: AT+CLRDTA** 446 446 447 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image019.png||alt="说明: image-20220609151132-7.png"]]449 +== 2.5 Downlink Payload == 448 448 449 -**~ 2.10 **Set trigger mode 450 450 451 - ➢ATCommand:**AT+TTRMOD**452 +By default, NMDS200 prints the downlink payload to console port. 452 452 453 - Feature:Set the trigger interruptmode.454 +[[image:image-20221021111414-18.png]] 454 454 455 -[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image020.png||alt="说明: image-20220609151344-9.png"]] 456 456 457 -** 2.11** Set the calculateflag457 +**Examples:** 458 458 459 - Feature: Setthe calculate flag459 +* (% style="color:#037691" %)**Set TDC** 460 460 461 - **ATCommand:AT+CALCFLAG**461 +If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01. 462 462 463 -|**Command Example**|**Function**|**Response** 464 -|AT+CALCFLAG =1|Set the calculate flag to 1.|OK 465 -|AT+CALCFLAG =2|Set the calculate flag to 2.|OK 463 +Payload: 01 00 00 1E TDC=30S 466 466 467 - **2.12**Setcountnumber465 +Payload: 01 00 00 3C TDC=60S 468 468 469 - Feature:Manuallysettheuntnumber467 +* (% style="color:#037691" %)**Reset** 470 470 471 - **ATCommand:AT+SETCNT**469 +If payload = 0x04FF, it will reset the NMDS200 472 472 473 -|**Command Example**|**Function**|**Response** 474 -|AT+ SETCNT =0|Set the count number to 0.|OK 475 -|AT+ SETCNT =100|Set the count number to 100.|OK 471 +* (% style="color:#037691" %)**INTMOD** 476 476 473 +Downlink Payload: 06000003, Set AT+INTMOD=3 477 477 478 -**2.13 Set the number of data to be uploaded and the recording time** 479 479 480 - ➢ATCommand:476 +== 2.6 LED Indicator == 481 481 482 -AT+TR=900 ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 483 483 479 +The NMDS200 has an internal LED which is to show the status of different states. 484 484 485 -AT+NOUD=8 ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 481 +* When the device starts normally, the LED will light up for 1 second. 482 +* After NMDS200 join NB-IoT network. The LED will be ON for 3 seconds. 483 +* For each uplink probe, LED will be on for 500ms. 486 486 487 - **2.14Reador Clear cached data**485 +== 2.7 Distance alarm function == 488 488 489 -➢ AT Command: 490 490 491 -AT +CDP~/~/ Readcached data488 +(% style="color:blue" %)**AT Command: AT+ALARM1=min,max** 492 492 493 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image021.png]]490 +(% style="color:#037691" %)**Example 1:** 494 494 492 +AT+ ALARM1 =60,200 ~/~/ Alarm when distance1 lower than 60. 495 495 496 -AT+ CDP=0~/~/Clear cached data 494 +AT+ ALARM2 =min,max 497 497 498 -**2.15 Firmware Change Log** 499 499 500 - DownloadURL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0>>url:https://www.dropbox.com/sh/1zmcakvbkf24f8x/AACmq2dZ3iRB9F1nVWeEB9Moa?dl=0]]497 +(% style="color:#037691" %)**Example 2:** 501 501 502 - UpgradeInstruction: [[UpgradeFirmware>>path:#H5.1200BHowtoUpgradeFirmware]]499 +AT+ ALARM2 =200,1500 ~/~/ Alarm when distance2 lower than 1500. 503 503 504 -**2.16 Battery Analysis** 505 505 506 - **2.16.1BatteryType**502 +== 2.8 Set the number of data to be uploaded and the recording time == 507 507 508 -The CPN01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 509 509 510 - Thebatteryis designed toast forseveralyearsdependson the actually use environmentandupdate interval.505 +(% style="color:blue" %)**AT Command:** 511 511 512 -The batteryrelated documents asbelow:507 +(% style="color:#037691" %)**AT+TR=900**(%%) ~/~/ The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 513 513 514 -* [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 515 -* [[Lithium-Thionyl Chloride Battery datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 516 -* [[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]] 509 +(% style="color:#037691" %)**AT+NOUD=8**(%%)** ** ~/~/ The device uploads 0 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 517 517 518 -[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image022.png||alt="说明: image-20220708140453-6.png"]] 519 519 520 - **2.16.2Power consumption Analyze**512 +== 2.9 Read or Clear cached data == 521 521 522 -Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 523 523 524 - Instruction toseasbelow:515 +(% style="color:blue" %)**AT Command:** 525 525 526 - **Step 1:ownlinktheup-to-dateDRAGINO_Battery_Life_Prediction_Table.xlsxfrom: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]517 +(% style="color:#037691" %)**AT+CDP** (%%) ~/~/ Read cached data 527 527 528 - **Step 2: **Openitandchoose519 +(% style="color:#037691" %)**AT+CDP=0** (%%) ~/~/ Clear cached data 529 529 530 -* Product Model 531 -* Uplink Interval 532 -* Working Mode 521 +[[image:1670408172929-569.png]] 533 533 534 -And the Life expectation in difference case will be shown on the right. 535 535 536 - [[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image023.jpg||alt="说明:image-20220708141352-7.jpeg"]]524 +== 2.10 Firmware Change Log == 537 537 538 -**2.16.3 Battery Note** 539 539 540 - TheLi-SICObatteryis designed forsmall current/ longperiodapplication. It is notgood to use ahigh current, shorteriodtransmit method.The recommended minimumperiodfor use ofis battery is5 minutes.If you use a shorterperiod time to transmitLoRa,then the battery life may bedecreased.527 +Download URL & Firmware Change log: [[https:~~/~~/www.dropbox.com/sh/8elvp2qi9bcv47a/AAAKp0E2nUffztF0tYhqPoE1a?dl=0>>https://www.dropbox.com/sh/8elvp2qi9bcv47a/AAAKp0E2nUffztF0tYhqPoE1a?dl=0]] 541 541 542 - **2.16.4 Replace thebattery**529 +Upgrade Instruction: [[Upgrade Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]] 543 543 544 -The default battery pack of CPN01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 545 545 546 - **3.AccessNB-IoTModule**532 +== 2.11 Battery & Power Consumption == 547 547 534 + 535 +NMDS200 uses ER26500 + SPC1520 battery pack. See below link for detail information about the battery info and how to replace. 536 + 537 +[[**Battery Info & Power Consumption Analyze**>>url:http://wiki.dragino.com/xwiki/bin/view/Main/How%20to%20calculate%20the%20battery%20life%20of%20Dragino%20sensors%3F/]] . 538 + 539 + 540 += 3. Access NB-IoT Module = 541 + 542 + 548 548 Users can directly access the AT command set of the NB-IoT module. 549 549 550 550 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 551 551 552 -[[image:file:///C:\Users\ADMINI~~1\AppData\Local\Temp\msohtmlclip1\01\clip_image024.png||alt="说明: 1657261278785-153.png"]] 553 553 554 - **4. UsingtheAT Commands**548 +[[image:image-20221118094449-6.png]] 555 555 556 -**4.1 Access AT Commands** 557 557 551 += 4. Using the AT Commands = 552 + 553 +== 4.1 Access AT Commands == 554 + 555 + 558 558 See this link for detail: [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]] 559 559 560 560 AT+<CMD>? : Help on <CMD> ... ... @@ -565,8 +565,9 @@ 565 565 566 566 AT+<CMD>=? : Get the value 567 567 568 -**General Commands** 569 569 567 +(% style="color:blue" %)**General Commands** 568 + 570 570 AT : Attention 571 571 572 572 AT? : Short Help ... ... @@ -581,133 +581,113 @@ 581 581 582 582 AT+INTMOD : Set the trigger interrupt mode 583 583 584 -AT+5VT 583 +AT+5VT : Set extend the time of 5V power 585 585 586 -AT+PRO 585 +AT+PRO : Choose agreement 587 587 588 -AT+RXDL 587 +AT+RXDL : Extend the sending and receiving time 589 589 590 -AT+SERVADDR 589 +AT+SERVADDR : Server Address 591 591 592 -AT+TR : Get or Set record time "591 +AT+TR : Get or Set record time 593 593 593 +AT+NOUD : Get or Set the number of data to be uploaded 594 594 595 -AT+ NOUDGetorSetthenumber ofdatato be uploaded595 +AT+CDP : Read or Clear cached data 596 596 597 +AT+DEBUG: Enable or Disable debug mode 597 597 598 -AT+ CDP: ReadorClearcacheddata599 +AT+ALARM1: Get or Set alarm of distance1 599 599 601 +AT+ALARM2: Get or Set alarm of distance2 600 600 601 -AT+ DEBUG:EnableorDisabledebugmode603 +AT+GETSENSORVALUE : Returns the current sensor measurement 602 602 603 -AT+ TTRIG: Get orSetAlarm Base on Timeout605 +AT+POWERIC : Get or set the Power IC flag 604 604 605 -AT+ TTRMOD : Get or Set the trigger interrupt mode(0:falling,1:rising) 606 606 607 - AT+CALCFLAG : GetSetthecalculateflag608 +(% style="color:blue" %)**COAP Management** 608 608 609 -AT+ CLRC:Clearcurrentdoor open count610 +AT+URI : Resource parameters 610 610 611 -**COAP Management** 612 612 613 - AT+URI: Resourceparameters613 +(% style="color:blue" %)**UDP Management** 614 614 615 - **UDPManagement**615 +AT+CFM : Upload confirmation mode (only valid for UDP) 616 616 617 -AT+CFM : Upload confirmation mode (only valid for UDP) 618 618 619 -**MQTT Management** 618 +(% style="color:blue" %)**MQTT Management** 620 620 621 -AT+CLIENT 620 +AT+CLIENT : Get or Set MQTT client 622 622 623 -AT+UNAME 622 +AT+UNAME : Get or Set MQTT Username 624 624 625 -AT+PWD 624 +AT+PWD : Get or Set MQTT password 626 626 627 -AT+PUBTOPIC :Get or Set MQTT publish topic626 +AT+PUBTOPIC : Get or Set MQTT publish topic 628 628 629 -AT+SUBTOPIC :Get or Set MQTT subscription topic628 +AT+SUBTOPIC : Get or Set MQTT subscription topic 630 630 631 -**Information** 632 632 633 - AT+FDR: FactoryDataReset631 +(% style="color:blue" %)**Information** 634 634 635 -AT+ PWORD:SerialAccessPassword633 +AT+FDR : Factory Data Reset 636 636 637 - **5.FAQ**635 +AT+PWORD : Serial Access Password 638 638 639 -**5.1 How to Upgrade Firmware** 640 640 641 - Usercanupgradethe firmware for 1) bug fix, 2) new feature release.638 += 5. FAQ = 642 642 643 - Pleaseseethislink for how toupgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]640 +== 5.1 How to Upgrade Firmware == 644 644 645 -**Notice, **CPN01 **and **CPN01 **share the same mother board. They use the same connection and method to update.** 646 646 647 - **5.2CanI calibrateCPN01todifferentsoiltypes?**643 +User can upgrade the firmware for 1) bug fix, 2) new feature release. 648 648 649 - CPN01 is calibratedforsaline-alkalisoilandloamy soil.Ifuserswantto useitfor othersoil, they cancalibratethe valueinhe IoT platformbasen the value measuredby saline-alkali soil andloamy soil. Theformula can befoundat[[thislink>>url:https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].645 +Please see this link for how to upgrade: [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]] 650 650 651 -** 6.Trouble Shooting**647 +(% style="color:red" %)**Notice: **(% style="color:blue" %)**NMDS200** (%%)**and (% style="color:blue" %)LMDS200(%%)**(% style="color:blue" %) (%%)**share the same mother board. They use the same connection and method to update.** 652 652 653 -**6.1 Connection problem when uploading firmware** 654 654 655 - **Pleasesee: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]650 += 6. Trouble Shooting = 656 656 657 - **6.2ATCommand inputdoesn'twork**652 +== 6.1 Connection problem when uploading firmware == 658 658 659 -In the case if user can see the console output but can't type input to the device. Please check if you already include the **ENTER** while sending out the command. Some serial tool doesn't send **ENTER** while press the send key, user need to add ENTER in their string. 660 660 661 -** 7.Order**655 +(% style="color:blue" %)**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]] 662 662 663 -Part Number**:** CPN01 664 664 665 - **8.PackingInfo**658 +== 6.2 AT Command input doesn't work == 666 666 667 -**Package Includes**: 668 668 669 -* CPN01 NB-IoT Soil Moisture & EC Sensor x 1 670 -* External antenna x 1 661 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER** (%%)while press the send key, user need to add ENTER in their string. 671 671 672 -**Dimension and weight**: 673 673 674 -* Size: 195 x 125 x 55 mm 675 -* Weight: 420g 664 +== 6.3 Not able to connect to NB-IoT network and keep showing "Signal Strength:99". == 676 676 677 -**9. Support** 678 678 679 -* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 680 -* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 667 +This means sensor is trying to join the NB-IoT network but fail. Please see this link for **//[[trouble shooting for signal strenght:99>>doc:Main.CSQ\:99,99.WebHome]]//**. 681 681 682 - 683 683 670 += 7. Order Info = 684 684 685 685 673 +Part Number:(% style="color:blue" %)** NMDS200** 686 686 687 687 676 += 8. Packing Info = 688 688 689 689 679 +(% style="color:blue" %)**Package Includes**: 690 690 681 +* NMDS200 NB-IoT Microwave Radar Distance Sensor x 1 691 691 692 692 693 693 685 += 9. Support = 694 694 695 695 688 +* Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 696 696 690 +* Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 697 697 698 - 699 - 700 - 701 - 702 - 703 - 704 - 705 - 706 - 707 - 708 - 709 - 710 - 711 - 712 - 713 - 692 +
- 1666596205057-567.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +179.8 KB - Content
- 1670404362039-351.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +492.6 KB - Content
- 1670405841875-916.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.1 KB - Content
- 1670405928926-116.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.7 KB - Content
- 1670406036256-101.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +181.0 KB - Content
- 1670406261143-723.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.9 KB - Content
- 1670407401682-959.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.7 KB - Content
- 1670408172929-569.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +211.8 KB - Content
- 1670471530120-960.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +67.6 KB - Content
- 1670471559211-638.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +170.6 KB - Content
- 1670471584490-640.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +91.1 KB - Content
- 1670471613823-833.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +181.0 KB - Content
- LMDS200_10.jpg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +39.9 KB - Content
- image-20221022234529-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.3 KB - Content
- image-20221022234602-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +135.7 KB - Content
- image-20221023000439-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +82.1 KB - Content
- image-20221117105556-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.3 KB - Content
- image-20221117114459-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +14.9 KB - Content
- image-20221117114842-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +964.1 KB - Content
- image-20221117114937-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.1 KB - Content
- image-20221117114949-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.4 KB - Content
- image-20221117115010-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.4 KB - Content
- image-20221117142300-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +147.8 KB - Content
- image-20221117145932-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +51.9 KB - Content
- image-20221117150312-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +8.7 KB - Content
- image-20221118092935-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +13.1 KB - Content
- image-20221118093144-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +11.7 KB - Content
- image-20221118093512-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +9.5 KB - Content
- image-20221118093658-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +12.7 KB - Content
- image-20221118094227-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.2 KB - Content
- image-20221118094449-6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.5 KB - Content
- image-20221118103445-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.4 KB - Content
- image-20221118103453-8.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +46.2 KB - Content
- image-20221118103547-9.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +43.5 KB - Content
- image-20221207170748-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +26.1 KB - Content
- image-20221207170748-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.9 KB - Content
- image-20221207173200-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +76.7 KB - Content
- image-20221207173300-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +77.0 KB - Content
- image-20221208090742-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +79.7 KB - Content
- image-20221209090938-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +121.9 KB - Content
- image-20221212171610-1.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +756.0 KB - Content