<
From version < 36.1 >
edited by Edwin Chen
on 2022/10/09 00:08
To version < 33.7 >
edited by Xiaoling
on 2022/09/23 15:45
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Edwin
1 +XWiki.Xiaoling
Content
... ... @@ -71,6 +71,8 @@
71 71  * - B20 @H-FDD: 800MHz
72 72  * - B28 @H-FDD: 700MHz
73 73  
74 +
75 +
74 74  == 1.4  Probe Specification ==
75 75  
76 76  
... ... @@ -90,11 +90,15 @@
90 90  * IP67 Protection
91 91  * Length: 3.5 meters
92 92  
95 +
96 +
93 93  == 1.5 ​ Applications ==
94 94  
95 95  
96 96  * Smart Agriculture
97 97  
102 +
103 +
98 98  == 1.6  Pin mapping and power on ==
99 99  
100 100  
... ... @@ -310,6 +310,8 @@
310 310  * Leaf Temperature, Leaf moisture,Time stamp : 010b0226631550fb
311 311  * 8 sets of recorded data: Leaf Temperature, Leaf moisture,Time stamp : 010e022663154d77,.......
312 312  
319 +
320 +
313 313  == 2.4  Payload Explanation and Sensor Interface ==
314 314  
315 315  
... ... @@ -477,6 +477,8 @@
477 477  * After NLMS01 join NB-IoT network. The LED will be ON for 3 seconds.
478 478  * For each uplink probe, LED will be on for 500ms.
479 479  
488 +
489 +
480 480  == 2.7  Installation ==
481 481  
482 482  
... ... @@ -528,11 +528,8 @@
528 528  * (% style="color:#037691" %)**AT+TR=900**   (%%) ~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
529 529  * (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
530 530  
531 - The diagram below explains the relationship between TR, NOUD, and TDC more clearly**:**
532 532  
533 -[[image:image-20221009000513-1.png||height="732" width="1018"]]
534 534  
535 -
536 536  == 2.10  Read or Clear cached data ==
537 537  
538 538  
... ... @@ -628,86 +628,86 @@
628 628  
629 629  See this link for detail:  [[https:~~/~~/www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0>>url:https://www.dropbox.com/sh/351dwor6joz8nwh/AADn1BQaAAxLF_QMyU8NkW47a?dl=0]]
630 630  
631 -AT+<CMD>?  :  Help on <CMD>
638 +AT+<CMD>?  : Help on <CMD>
632 632  
633 -AT+<CMD>  Run <CMD>
640 +AT+<CMD>         : Run <CMD>
634 634  
635 -AT+<CMD>=<value>:  Set the value
642 +AT+<CMD>=<value> : Set the value
636 636  
637 -AT+<CMD>=?  Get the value
644 +AT+<CMD>=?  : Get the value
638 638  
639 639  
640 640  (% style="color:#037691" %)**General Commands**      
641 641  
642 -AT  Attention       
649 +AT  : Attention       
643 643  
644 -AT?  Short Help     
651 +AT?  : Short Help     
645 645  
646 -ATZ  MCU Reset    
653 +ATZ  : MCU Reset    
647 647  
648 -AT+TDC  :  Application Data Transmission Interval
655 +AT+TDC  : Application Data Transmission Interval
649 649  
650 -AT+CFG  :  Print all configurations
657 +AT+CFG  : Print all configurations
651 651  
652 -AT+CFGMOD  :  Working mode selection
659 +AT+CFGMOD           : Working mode selection
653 653  
654 -AT+INTMOD  :  Set the trigger interrupt mode
661 +AT+INTMOD            : Set the trigger interrupt mode
655 655  
656 -AT+5VT  Set extend the time of 5V power  
663 +AT+5VT  : Set extend the time of 5V power  
657 657  
658 -AT+PRO :  Choose agreement
665 +AT+PRO  : Choose agreement
659 659  
660 -AT+RXDL:  Extend the sending and receiving time
667 +AT+RXDL  : Extend the sending and receiving time
661 661  
662 -AT+SERVADDR :  Server Address
669 +AT+SERVADDR  : Server Address
663 663  
664 -AT+APN :  Get or set the APN
671 +AT+APN     : Get or set the APN
665 665  
666 -AT+FBAND :  Get or Set whether to automatically modify the frequency band
673 +AT+FBAND   : Get or Set whether to automatically modify the frequency band
667 667  
668 -AT+DNSCFG : Get or Set DNS Server
675 +AT+DNSCFG  : Get or Set DNS Server
669 669  
670 670  AT+GETSENSORVALUE   : Returns the current sensor measurement
671 671  
672 -AT+TR :  Get or Set record time"
679 +AT+TR      : Get or Set record time"
673 673  
674 -AT+NOUD :  Get or Set the number of data to be uploaded
681 +AT+NOUD      : Get or Set the number of data to be uploaded
675 675  
676 -AT+CDP :  Read or Clear cached data
683 +AT+CDP     : Read or Clear cached data
677 677  
678 -AT+TEMPALARM :  Get or Set alarm of temp
685 +AT+TEMPALARM      : Get or Set alarm of temp
679 679  
680 -AT+HUMALARM :  Get or Set alarm of humidity
687 +AT+HUMALARM     : Get or Set alarm of PH
681 681  
682 682  
683 683  (% style="color:#037691" %)**COAP Management**      
684 684  
685 -AT+URI :  Resource parameters
692 +AT+URI            : Resource parameters
686 686  
687 687  
688 688  (% style="color:#037691" %)**UDP Management**
689 689  
690 -AT+CFM :  Upload confirmation mode (only valid for UDP)
697 +AT+CFM          : Upload confirmation mode (only valid for UDP)
691 691  
692 692  
693 693  (% style="color:#037691" %)**MQTT Management**
694 694  
695 -AT+CLIENT  :  Get or Set MQTT client
702 +AT+CLIENT               : Get or Set MQTT client
696 696  
697 -AT+UNAME  : Get or Set MQTT Username
704 +AT+UNAME  : Get or Set MQTT Username
698 698  
699 -AT+PWD  :  Get or Set MQTT password
706 +AT+PWD                  : Get or Set MQTT password
700 700  
701 -AT+PUBTOPIC  Get or Set MQTT publish topic
708 +AT+PUBTOPIC  : Get or Set MQTT publish topic
702 702  
703 -AT+SUBTOPIC :  Get or Set MQTT subscription topic
710 +AT+SUBTOPIC  : Get or Set MQTT subscription topic
704 704  
705 705  
706 706  (% style="color:#037691" %)**Information**          
707 707  
708 -AT+FDR :  Factory Data Reset
715 +AT+FDR  : Factory Data Reset
709 709  
710 -AT+PWORD :  Serial Access Password
717 +AT+PWORD  : Serial Access Password
711 711  
712 712  
713 713  
... ... @@ -764,6 +764,7 @@
764 764  * Package Size / pcs : cm
765 765  * Weight / pcs : g
766 766  
774 +
767 767  = 9.  Support =
768 768  
769 769  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0