Changes for page NDDS75 -- NB-IoT Distance Detect Sensor User Manual
Last modified by Bei Jinggeng on 2024/05/31 09:53
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -3,14 +3,6 @@ 3 3 4 4 5 5 6 - 7 - 8 - 9 - 10 - 11 - 12 - 13 - 14 14 **Table of Contents:** 15 15 16 16 {{toc/}} ... ... @@ -68,6 +68,8 @@ 68 68 * IP66 Waterproof Enclosure 69 69 * 4000mAh or 8500mAh Battery for long term use 70 70 63 + 64 + 71 71 == 1.3 Specification == 72 72 73 73 Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. ... ... @@ -304,10 +304,11 @@ 304 304 ))) 305 305 306 306 ((( 307 -LSE01 TTN Payload Decoder: [[http s:~~/~~/www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0>>https://www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0]]301 +LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]] 308 308 ))) 309 309 310 310 305 + 311 311 == 2.4 Uplink Interval == 312 312 313 313 The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] ... ... @@ -375,11 +375,11 @@ 375 375 ))) 376 376 377 377 ((( 378 - (% style="color:blue" %)**Step 1**(%%):373 +**Step 1**: Be sure that your device is programmed and properly connected to the network at this time. 379 379 ))) 380 380 381 381 ((( 382 - (% style="color:blue" %)**Step 2**(%%):377 +**Step 2**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps: 383 383 ))) 384 384 385 385 ... ... @@ -388,12 +388,11 @@ 388 388 389 389 [[image:1654505874829-548.png]] 390 390 386 +Step 3: Create an account or log in Datacake. 391 391 392 - (% style="color:blue" %)**Step3**(%%)**:**Create an accountor log inDatacake.388 +Step 4: Search the LSE01 and add DevEUI. 393 393 394 -(% style="color:blue" %)**Step 4**(%%)**:** Search the LSE01 and add DevEUI. 395 395 396 - 397 397 [[image:1654505905236-553.png]] 398 398 399 399 ... ... @@ -689,9 +689,6 @@ 689 689 * Solid ON for 5 seconds once device successful Join the network. 690 690 * Blink once when device transmit a packet. 691 691 692 - 693 - 694 - 695 695 == 2.9 Installation in Soil == 696 696 697 697 **Measurement the soil surface** ... ... @@ -706,7 +706,6 @@ 706 706 ))) 707 707 708 708 709 - 710 710 [[image:1654506665940-119.png]] 711 711 712 712 ((( ... ... @@ -768,13 +768,13 @@ 768 768 ))) 769 769 770 770 * ((( 771 -[[Battery Dimension>>http s://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],761 +[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], 772 772 ))) 773 773 * ((( 774 -[[Lithium-Thionyl Chloride Battery datasheet>>https://www.dragino.com/downloads/ index.php?dir=datasheet/Battery/]],764 +[[Lithium-Thionyl Chloride Battery datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]], 775 775 ))) 776 776 * ((( 777 -[[Lithium-ion Battery-Capacitor datasheet>>http s://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]767 +[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]] 778 778 ))) 779 779 780 780 [[image:image-20220610172436-1.png]] ... ... @@ -828,7 +828,7 @@ 828 828 [[image:1654502050864-459.png||height="564" width="806"]] 829 829 830 830 831 -Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>http s://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]: [[https:~~/~~/www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]821 +Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]] 832 832 833 833 834 834 (% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>? **(%%) : Help on <CMD> ... ... @@ -986,14 +986,19 @@ 986 986 987 987 ((( 988 988 Because the end node is now hopping in 72 frequency, it makes it difficult for the devices to Join the TTN network and uplink data. To solve this issue, you can access the device via the AT commands and run: 979 +))) 989 989 990 -* (% style="color:#037691" %)**AT+CHE=2** 991 -* (% style="color:#037691" %)**ATZ** 981 +(% class="box infomessage" %) 982 +((( 983 +**AT+CHE=2** 992 992 ))) 993 993 986 +(% class="box infomessage" %) 994 994 ((( 995 - 988 +**ATZ** 989 +))) 996 996 991 +((( 997 997 to set the end node to work in 8 channel mode. The device will work in Channel 8-15 & 64-71 for OTAA, and channel 8-15 for Uplink. 998 998 ))) 999 999 ... ... @@ -1008,11 +1008,7 @@ 1008 1008 [[image:image-20220606154825-4.png]] 1009 1009 1010 1010 1011 -== 4.2 Can I calibrate LSE01 to different soil types? == 1012 1012 1013 -LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]]. 1014 - 1015 - 1016 1016 = 5. Trouble Shooting = 1017 1017 1018 1018 == 5.1 Why I can’t join TTN in US915 / AU915 bands? ==