Changes for page NDDS75 -- NB-IoT Distance Detect Sensor User Manual
Last modified by Bei Jinggeng on 2024/05/31 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,17 +1,13 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20220606151504-2.jpeg||height=" 554" width="554"]]2 +[[image:image-20220606151504-2.jpeg||height="848" width="848"]] 3 3 4 4 5 5 6 -**Contents:** 7 7 8 -{{toc/}} 9 9 10 10 11 11 12 12 13 - 14 - 15 15 = 1. Introduction = 16 16 17 17 == 1.1 What is LoRaWAN Soil Moisture & EC Sensor == ... ... @@ -58,7 +58,6 @@ 58 58 * IP66 Waterproof Enclosure 59 59 * 4000mAh or 8500mAh Battery for long term use 60 60 61 - 62 62 == 1.3 Specification == 63 63 64 64 Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. ... ... @@ -90,7 +90,7 @@ 90 90 ))) 91 91 92 92 ((( 93 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3. 200BUsingtheATCommands"]].88 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.UsingtheATCommands"]]. 94 94 ))) 95 95 96 96 ... ... @@ -151,17 +151,16 @@ 151 151 Uplink payload includes in total 11 bytes. 152 152 153 153 154 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %) 155 -|=((( 149 +|((( 156 156 **Size** 157 157 158 158 **(bytes)** 159 -)))| =(% style="width: 46px;" %)**2**|=(% style="width: 160px;" %)**2**|=(% style="width: 104px;" %)**2**|=(% style="width: 126px;" %)**2**|=(% style="width: 159px;" %)**2**|=(% style="width: 114px;" %)**1**160 -|**Value**| (% style="width:46px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:160px" %)(((153 +)))|**2**|**2**|**2**|**2**|**2**|**1** 154 +|**Value**|[[BAT>>path:#bat]]|((( 161 161 Temperature 162 162 163 163 (Reserve, Ignore now) 164 -)))| (% style="width:104px" %)[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|(% style="width:126px" %)[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|(% style="width:159px" %)[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(% style="width:114px" %)(((158 +)))|[[Soil Moisture>>path:#soil_moisture]]|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]]|((( 165 165 MOD & Digital Interrupt 166 166 167 167 (Optional) ... ... @@ -175,17 +175,16 @@ 175 175 176 176 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 177 177 178 -(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %) 179 -|=((( 172 +|((( 180 180 **Size** 181 181 182 182 **(bytes)** 183 -)))| =**2**|=**2**|=**2**|=**2**|=**2**|=**1**184 -|**Value**|[[BAT>> ||anchor="H2.3.3BatteryInfo"]]|(((176 +)))|**2**|**2**|**2**|**2**|**2**|**1** 177 +|**Value**|[[BAT>>path:#bat]]|((( 185 185 Temperature 186 186 187 187 (Reserve, Ignore now) 188 -)))|[[Soil Moisture>> ||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((181 +)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|((( 189 189 MOD & Digital Interrupt 190 190 191 191 (Optional) ... ... @@ -259,7 +259,7 @@ 259 259 mod=(bytes[10]>>7)&0x01=1. 260 260 261 261 262 - **Downlink Command:**255 +Downlink Command: 263 263 264 264 If payload = 0x0A00, workmode=0 265 265 ... ... @@ -279,13 +279,14 @@ 279 279 LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]] 280 280 281 281 282 - 283 283 == 2.4 Uplink Interval == 284 284 285 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]277 +The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: 286 286 279 +[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]] 287 287 288 288 282 + 289 289 == 2.5 Downlink Payload == 290 290 291 291 By default, LSE50 prints the downlink payload to console port. ... ... @@ -632,7 +632,6 @@ 632 632 * Blink once when device transmit a packet. 633 633 634 634 635 - 636 636 == 2.9 Installation in Soil == 637 637 638 638 **Measurement the soil surface** ... ... @@ -641,21 +641,16 @@ 641 641 [[image:1654506634463-199.png]] 642 642 643 643 ((( 644 -((( 645 645 Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting. 646 646 ))) 647 -))) 648 648 649 649 641 + 650 650 [[image:1654506665940-119.png]] 651 651 652 -((( 653 653 Dig a hole with diameter > 20CM. 654 -))) 655 655 656 -((( 657 657 Horizontal insert the probe to the soil and fill the hole for long term measurement. 658 -))) 659 659 660 660 661 661 == 2.10 Firmware Change Log == ... ... @@ -752,13 +752,13 @@ 752 752 753 753 LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below. 754 754 755 -[[image:1654501986557-872.png ||height="391" width="800"]]743 +[[image:1654501986557-872.png]] 756 756 757 757 758 758 Or if you have below board, use below connection: 759 759 760 760 761 -[[image:1654502005655-729.png ||height="503" width="801"]]749 +[[image:1654502005655-729.png]] 762 762 763 763 764 764 ... ... @@ -765,7 +765,7 @@ 765 765 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below: 766 766 767 767 768 - [[image:1654502050864-459.png ||height="564" width="806"]]756 + [[image:1654502050864-459.png]] 769 769 770 770 771 771 Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]] ... ... @@ -880,7 +880,7 @@ 880 880 881 881 == 4.1 How to change the LoRa Frequency Bands/Region? == 882 882 883 -You can follow the instructions for [[how to upgrade image>> ||anchor="H2.10200BFirmwareChangeLog"]].871 +You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 884 884 When downloading the images, choose the required image file for download. 885 885 886 886 ... ... @@ -936,9 +936,7 @@ 936 936 937 937 == 5.2 AT Command input doesn’t work == 938 938 939 -((( 940 940 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 941 -))) 942 942 943 943 944 944 == 5.3 Device rejoin in at the second uplink packet == ... ... @@ -950,9 +950,7 @@ 950 950 951 951 (% style="color:#4f81bd" %)**Cause for this issue:** 952 952 953 -((( 954 954 The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin. 955 -))) 956 956 957 957 958 958 (% style="color:#4f81bd" %)**Solution: ** ... ... @@ -959,7 +959,7 @@ 959 959 960 960 All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below: 961 961 962 -[[image:1654500929571-736.png ||height="458" width="832"]]946 +[[image:1654500929571-736.png]] 963 963 964 964 965 965 = 6. Order Info = ... ... @@ -984,11 +984,6 @@ 984 984 * (% style="color:red" %)**4**(%%): 4000mAh battery 985 985 * (% style="color:red" %)**8**(%%): 8500mAh battery 986 986 987 -(% class="wikigeneratedid" %) 988 -((( 989 - 990 -))) 991 - 992 992 = 7. Packing Info = 993 993 994 994 ((( ... ... @@ -1018,9 +1018,6 @@ 1018 1018 ))) 1019 1019 * ((( 1020 1020 Weight / pcs : g 1021 - 1022 - 1023 - 1024 1024 ))) 1025 1025 1026 1026 = 8. Support =