Changes for page NDDS75 -- NB-IoT Distance Detect Sensor User Manual
Last modified by Bei Jinggeng on 2024/05/31 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -66,11 +66,9 @@ 66 66 67 67 * Smart Agriculture 68 68 69 - 70 70 (% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %) 71 71 72 72 73 -(% class="wikigeneratedid" %) 74 74 == 1.5 Firmware Change log == 75 75 76 76 ... ... @@ -122,37 +122,25 @@ 122 122 123 123 [[image:1654504683289-357.png]] 124 124 125 -|((( 126 - 127 -))) 128 128 124 + 129 129 **Step 2**: Power on LSE01 130 130 131 131 132 132 Put a Jumper on JP2 to power on the device. ( The Jumper must be in FLASH position). 133 133 130 +[[image:image-20220606163915-7.png]] 134 134 135 135 136 -|((( 137 - 138 -))) 139 - 140 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image006.png]] 141 - 142 - 143 - 144 - 145 - 146 146 **Step 3:** The LSE01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 147 147 148 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]]135 +[[image:1654504778294-788.png]] 149 149 150 150 151 151 139 +== 2.3 Uplink Payload == 152 152 153 -1. 154 -11. Uplink Payload 155 -111. MOD=0(Default Mode) 141 +=== 2.3.1 MOD~=0(Default Mode) === 156 156 157 157 LSE01 will uplink payload via LoRaWAN with below payload format: 158 158 ... ... @@ -175,13 +175,12 @@ 175 175 (Optional) 176 176 ))) 177 177 178 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]]164 +[[image:1654504881641-514.png]] 179 179 180 180 181 -1. 182 -11. 183 -111. MOD=1(Original value) 184 184 168 +=== 2.3.2 MOD~=1(Original value) === 169 + 185 185 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 186 186 187 187 |((( ... ... @@ -199,12 +199,12 @@ 199 199 (Optional) 200 200 ))) 201 201 202 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image008.png]]187 +[[image:1654504907647-967.png]] 203 203 204 -1. 205 -11. 206 -111. Battery Info 207 207 190 + 191 +=== 2.3.3 Battery Info === 192 + 208 208 Check the battery voltage for LSE01. 209 209 210 210 Ex1: 0x0B45 = 2885mV ... ... @@ -213,21 +213,19 @@ 213 213 214 214 215 215 216 -1. 217 -11. 218 -111. Soil Moisture 201 +=== 2.3.4 Soil Moisture === 219 219 220 220 Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil. 221 221 222 -For example, if the data you get from the register is 0x05 0xDC, the moisture content in the soil is 205 +For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is 223 223 224 -**05DC(H) = 1500(D) /100 = 15%.** 225 225 208 +(% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.** 226 226 227 -1. 228 -11. 229 -111. Soil Temperature 230 230 211 + 212 +=== 2.3.5 Soil Temperature === 213 + 231 231 Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is 232 232 233 233 **Example**: ... ... @@ -237,8 +237,8 @@ 237 237 If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C 238 238 239 239 240 -1. 241 -11. 223 +1. 224 +11. 242 242 111. Soil Conductivity (EC) 243 243 244 244 Obtain soluble salt concentration in soil or soluble ion concentration in liquid fertilizer or planting medium,. The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000). ... ... @@ -248,8 +248,8 @@ 248 248 249 249 Generally, the EC value of irrigation water is less than 800uS / cm. 250 250 251 -1. 252 -11. 234 +1. 235 +11. 253 253 111. MOD 254 254 255 255 Firmware version at least v2.1 supports changing mode. ... ... @@ -266,8 +266,8 @@ 266 266 If** **payload =** **0x0A01, workmode=1 267 267 268 268 269 -1. 270 -11. 252 +1. 253 +11. 271 271 111. Decode payload in The Things Network 272 272 273 273 While using TTN network, you can add the payload format to decode the payload. ... ... @@ -280,7 +280,7 @@ 280 280 LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]] 281 281 282 282 283 -1. 266 +1. 284 284 11. Uplink Interval 285 285 286 286 The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: ... ... @@ -287,7 +287,7 @@ 287 287 288 288 [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]] 289 289 290 -1. 273 +1. 291 291 11. Downlink Payload 292 292 293 293 By default, LSE50 prints the downlink payload to console port. ... ... @@ -320,7 +320,7 @@ 320 320 321 321 Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0 322 322 323 -1. 306 +1. 324 324 11. Show Data in DataCake IoT Server 325 325 326 326 [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps: ... ... @@ -361,8 +361,8 @@ 361 361 362 362 The LSE01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets. 363 363 364 -1. 365 -11. 347 +1. 348 +11. 366 366 111. EU863-870 (EU868) 367 367 368 368 Uplink: ... ... @@ -393,8 +393,8 @@ 393 393 869.525 - SF9BW125 (RX2 downlink only) 394 394 395 395 396 -1. 397 -11. 379 +1. 380 +11. 398 398 111. US902-928(US915) 399 399 400 400 Used in USA, Canada and South America. Default use CHE=2 ... ... @@ -439,8 +439,8 @@ 439 439 923.3 - SF12BW500(RX2 downlink only) 440 440 441 441 442 -1. 443 -11. 425 +1. 426 +11. 444 444 111. CN470-510 (CN470) 445 445 446 446 Used in China, Default use CHE=1 ... ... @@ -485,8 +485,8 @@ 485 485 505.3 - SF12BW125 (RX2 downlink only) 486 486 487 487 488 -1. 489 -11. 471 +1. 472 +11. 490 490 111. AU915-928(AU915) 491 491 492 492 Default use CHE=2 ... ... @@ -530,8 +530,8 @@ 530 530 531 531 923.3 - SF12BW500(RX2 downlink only) 532 532 533 -1. 534 -11. 516 +1. 517 +11. 535 535 111. AS920-923 & AS923-925 (AS923) 536 536 537 537 **Default Uplink channel:** ... ... @@ -583,8 +583,8 @@ 583 583 923.2 - SF10BW125 (RX2) 584 584 585 585 586 -1. 587 -11. 569 +1. 570 +11. 588 588 111. KR920-923 (KR920) 589 589 590 590 Default channel: ... ... @@ -620,8 +620,8 @@ 620 620 921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125) 621 621 622 622 623 -1. 624 -11. 606 +1. 607 +11. 625 625 111. IN865-867 (IN865) 626 626 627 627 Uplink: ... ... @@ -640,7 +640,7 @@ 640 640 866.550 - SF10BW125 (RX2) 641 641 642 642 643 -1. 626 +1. 644 644 11. LED Indicator 645 645 646 646 The LSE01 has an internal LED which is to show the status of different state. ... ... @@ -650,7 +650,7 @@ 650 650 * Solid ON for 5 seconds once device successful Join the network. 651 651 * Blink once when device transmit a packet. 652 652 653 -1. 636 +1. 654 654 11. Installation in Soil 655 655 656 656 **Measurement the soil surface** ... ... @@ -677,7 +677,7 @@ 677 677 678 678 679 679 680 -1. 663 +1. 681 681 11. Firmware Change Log 682 682 683 683 **Firmware download link:** ... ... @@ -696,7 +696,7 @@ 696 696 697 697 698 698 699 -1. 682 +1. 700 700 11. Battery Analysis 701 701 111. Battery Type 702 702 ... ... @@ -720,15 +720,15 @@ 720 720 721 721 722 722 723 -1. 724 -11. 706 +1. 707 +11. 725 725 111. Battery Note 726 726 727 727 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased. 728 728 729 729 730 -1. 731 -11. 713 +1. 714 +11. 732 732 111. Replace the battery 733 733 734 734 If Battery is lower than 2.7v, user should replace the battery of LSE01.
- 1654504778294-788.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +119.4 KB - Content
- 1654504881641-514.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +119.4 KB - Content
- 1654504907647-967.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.7 KB - Content