Changes for page NDDS75 -- NB-IoT Distance Detect Sensor User Manual
Last modified by Bei Jinggeng on 2024/05/31 09:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 12 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,7 +1,6 @@ 1 1 (% style="text-align:center" %) 2 2 [[image:image-20220606151504-2.jpeg||height="848" width="848"]] 3 3 4 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png]] 5 5 6 6 7 7 ... ... @@ -9,44 +9,40 @@ 9 9 10 10 11 11 11 += 1. Introduction = 12 12 13 +== 1.1 What is LoRaWAN Soil Moisture & EC Sensor == 13 13 15 +((( 16 +The Dragino LSE01 is a (% style="color:#4f81bd" %)**LoRaWAN Soil Moisture & EC Sensor**(%%) for IoT of Agriculture. It is designed to measure the soil moisture of saline-alkali soil and loamy soil. The soil sensor uses FDR method to calculate the soil moisture with the compensation from soil temperature and conductivity. It also has been calibrated in factory for Mineral soil type. 17 +))) 14 14 19 +((( 20 +It detects (% style="color:#4f81bd" %)**Soil Moisture**(%%), (% style="color:#4f81bd" %)**Soil Temperature**(%%) and (% style="color:#4f81bd" %)**Soil Conductivity**(%%), and uploads the value via wireless to LoRaWAN IoT Server. 21 +))) 15 15 16 - 17 - 18 - 19 - 20 - 21 - 22 - 23 -1. Introduction 24 -11. What is LoRaWAN Soil Moisture & EC Sensor 25 - 26 -The Dragino LSE01 is a **LoRaWAN Soil Moisture & EC Sensor** for IoT of Agriculture. It is designed to measure the soil moisture of saline-alkali soil and loamy soil. The soil sensor uses FDR method to calculate the soil moisture with the compensation from soil temperature and conductivity. It also has been calibrated in factory for Mineral soil type. 27 - 28 - 29 -It detects **Soil Moisture**, **Soil Temperature** and **Soil Conductivity**, and uploads the value via wireless to LoRaWAN IoT Server. 30 - 31 - 23 +((( 32 32 The LoRa wireless technology used in LES01 allows device to send data and reach extremely long ranges at low data-rates. It provides ultra-long range spread spectrum communication and high interference immunity whilst minimizing current consumption. 25 +))) 33 33 27 +((( 28 +LES01 is powered by (% style="color:#4f81bd" %)**4000mA or 8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to 10 years. 29 +))) 34 34 35 -LES01 is powered by **4000mA or 8500mAh Li-SOCI2 battery**, It is designed for long term use up to 10 years. 36 - 37 - 31 +((( 38 38 Each LES01 is pre-load with a set of unique keys for LoRaWAN registrations, register these keys to local LoRaWAN server and it will auto connect after power on. 33 +))) 39 39 40 40 41 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image002.png]]36 +[[image:1654503236291-817.png]] 42 42 43 43 44 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image003.png]]39 +[[image:1654503265560-120.png]] 45 45 46 46 47 47 48 - *49 - *1. Features43 +== 1.2 Features == 44 + 50 50 * LoRaWAN 1.0.3 Class A 51 51 * Ultra low power consumption 52 52 * Monitor Soil Moisture ... ... @@ -59,63 +59,48 @@ 59 59 * IP66 Waterproof Enclosure 60 60 * 4000mAh or 8500mAh Battery for long term use 61 61 62 -1. 63 -11. Specification 57 +== 1.3 Specification == 64 64 65 65 Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. 66 66 67 -|**Parameter**|**Soil Moisture**|**Soil Conductivity**|**Soil Temperature** 68 -|**Range**|**0-100.00%**|((( 69 -**0-20000uS/cm** 61 +[[image:image-20220606162220-5.png]] 70 70 71 -**(25℃)(0-20.0EC)** 72 -)))|**-40.00℃~85.00℃** 73 -|**Unit**|**V/V %,**|**uS/cm,**|**℃** 74 -|**Resolution**|**0.01%**|**1 uS/cm**|**0.01℃** 75 -|**Accuracy**|((( 76 -**±3% (0-53%)** 77 77 78 -**±5% (>53%)** 79 -)))|**2%FS,**|((( 80 -**-10℃~50℃:<0.3℃** 81 81 82 -**All other: <0.6℃** 83 -))) 84 -|((( 85 -**Measure** 65 +== 1.4 Applications == 86 86 87 -**Method** 88 -)))|**FDR , with temperature &EC compensate**|**Conductivity , with temperature compensate**|**RTD, and calibrate** 89 - 90 -* 91 -*1. Applications 92 92 * Smart Agriculture 93 93 94 -1. 95 - 11.Firmware Change log69 +(% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %) 70 + 96 96 97 - **LSE01v1.0:**72 +== 1.5 Firmware Change log == 98 98 99 -* Release 100 100 101 -1. Configure LSE01 to connect to LoRaWAN network 102 -11. How it works 75 +**LSE01 v1.0 :** Release 103 103 104 -The LSE01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSE0150. It will automatically join the network via OTAA and start to send the sensor value 105 105 106 106 107 - Incaseyou can’t set the OTAA keysin the LoRaWANOTAA server, and you havetousehekeys fromthe server, youcan [[useATCommands >>path:#_Using_the_AT]]toset thekeysin the LSE01.79 += 2. Configure LSE01 to connect to LoRaWAN network = 108 108 81 +== 2.1 How it works == 109 109 83 +((( 84 +The LSE01 is configured as LoRaWAN OTAA Class A mode by default. It has OTAA keys to join LoRaWAN network. To connect a local LoRaWAN network, you need to input the OTAA keys in the LoRaWAN IoT server and power on the LSE0150. It will automatically join the network via OTAA and start to send the sensor value 85 +))) 110 110 87 +((( 88 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.UsingtheATCommands"]]. 89 +))) 111 111 112 -1. 113 -11. Quick guide to connect to LoRaWAN server (OTAA) 114 114 92 + 93 +== 2.2 Quick guide to connect to LoRaWAN server (OTAA) == 94 + 115 115 Following is an example for how to join the [[TTN v3 LoRaWAN Network>>url:https://console.cloud.thethings.network/]]. Below is the network structure; we use the [[LG308>>url:http://www.dragino.com/products/lora/item/140-lg308.html]] as a LoRaWAN gateway in this example. 116 116 117 117 118 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image003.png]]98 +[[image:1654503992078-669.png]] 119 119 120 120 121 121 The LG308 is already set to connected to [[TTN network >>url:https://console.cloud.thethings.network/]], so what we need to now is configure the TTN server. ... ... @@ -125,27 +125,22 @@ 125 125 126 126 Each LSE01 is shipped with a sticker with the default device EUI as below: 127 127 108 +[[image:image-20220606163732-6.jpeg]] 128 128 129 - 130 - 131 131 You can enter this key in the LoRaWAN Server portal. Below is TTN screen shot: 132 132 133 - 134 134 **Add APP EUI in the application** 135 135 136 136 137 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image004.png]]115 +[[image:1654504596150-405.png]] 138 138 139 139 140 140 141 141 **Add APP KEY and DEV EUI** 142 142 121 +[[image:1654504683289-357.png]] 143 143 144 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image005.png]] 145 145 146 -|((( 147 - 148 -))) 149 149 150 150 **Step 2**: Power on LSE01 151 151 ... ... @@ -152,28 +152,18 @@ 152 152 153 153 Put a Jumper on JP2 to power on the device. ( The Jumper must be in FLASH position). 154 154 130 +[[image:image-20220606163915-7.png]] 155 155 156 156 157 -|((( 158 - 159 -))) 160 - 161 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image006.png]] 162 - 163 - 164 - 165 - 166 - 167 167 **Step 3:** The LSE01 will auto join to the TTN network. After join success, it will start to upload messages to TTN and you can see the messages in the panel. 168 168 169 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]]135 +[[image:1654504778294-788.png]] 170 170 171 171 172 172 139 +== 2.3 Uplink Payload == 173 173 174 -1. 175 -11. Uplink Payload 176 -111. MOD=0(Default Mode) 141 +=== 2.3.1 MOD~=0(Default Mode) === 177 177 178 178 LSE01 will uplink payload via LoRaWAN with below payload format: 179 179 ... ... @@ -196,13 +196,12 @@ 196 196 (Optional) 197 197 ))) 198 198 199 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]]164 +[[image:1654504881641-514.png]] 200 200 201 201 202 -1. 203 -11. 204 -111. MOD=1(Original value) 205 205 168 +=== 2.3.2 MOD~=1(Original value) === 169 + 206 206 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 207 207 208 208 |((( ... ... @@ -220,12 +220,12 @@ 220 220 (Optional) 221 221 ))) 222 222 223 -[[image: file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image008.png]]187 +[[image:1654504907647-967.png]] 224 224 225 -1. 226 -11. 227 -111. Battery Info 228 228 190 + 191 +=== 2.3.3 Battery Info === 192 + 229 229 Check the battery voltage for LSE01. 230 230 231 231 Ex1: 0x0B45 = 2885mV ... ... @@ -234,21 +234,19 @@ 234 234 235 235 236 236 237 -1. 238 -11. 239 -111. Soil Moisture 201 +=== 2.3.4 Soil Moisture === 240 240 241 241 Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil. 242 242 243 -For example, if the data you get from the register is 0x05 0xDC, the moisture content in the soil is 205 +For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is 244 244 245 -**05DC(H) = 1500(D) /100 = 15%.** 246 246 208 +(% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.** 247 247 248 -1. 249 -11. 250 -111. Soil Temperature 251 251 211 + 212 +=== 2.3.5 Soil Temperature === 213 + 252 252 Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is 253 253 254 254 **Example**: ... ... @@ -258,10 +258,9 @@ 258 258 If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C 259 259 260 260 261 -1. 262 -11. 263 -111. Soil Conductivity (EC) 264 264 224 +=== 2.3.6 Soil Conductivity (EC) === 225 + 265 265 Obtain soluble salt concentration in soil or soluble ion concentration in liquid fertilizer or planting medium,. The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000). 266 266 267 267 For example, if the data you get from the register is 0x00 0xC8, the soil conductivity is 00C8(H) = 200(D) = 200 uS/cm.
- 1654503236291-817.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +685.6 KB - Content
- 1654503265560-120.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.8 KB - Content
- 1654503992078-669.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +85.8 KB - Content
- 1654504596150-405.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +66.7 KB - Content
- 1654504683289-357.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.0 KB - Content
- 1654504778294-788.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +119.4 KB - Content
- 1654504881641-514.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +119.4 KB - Content
- 1654504907647-967.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +54.7 KB - Content
- 1654505570700-128.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.2 KB - Content
- image-20220606162220-5.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.0 KB - Content
- image-20220606163732-6.jpeg
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +16.5 KB - Content
- image-20220606163915-7.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +94.8 KB - Content