... ... @@ -1331,21 +1331,25 @@
1331 1331  
1332 1332  
1333 1333  (((
1334 -NBSN95 will enable +5V output before all sampling and disable the +5v after all sampling. 
1335 -)))
1334 +Control the output duration 5V . Before each sampling, device will
1336 1336  
1336 +~1. first enable the power output to external sensor,
1337 1337  
1338 -(((
1339 -The 5V output time can be controlled by AT Command.
1340 -)))
1338 +2. keep it on as per duration, read sensor value and construct uplink payload
1341 1341  
1342 -(((
1343 -(% style="color:blue" %)**AT+5VT=1000**
1344 -)))
1340 +3. final, close the power output.
1345 1345  
1346 -(((
1347 -Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.
1342 +**AT Command: AT+5VT**
1343 +
1344 +|=**Command Example**|=**Function**|=**Response**
1345 +|AT+5VT=?|Show 5V open time.|(((
1346 +0(default)
1347 +OK
1348 1348  )))
1349 +|AT+5VT=1000|(((
1350 +Close after a delay of 1000 milliseconds.
1351 +)))|OK
1352 +)))
1349 1349  
1350 1350  
1351 1351  === 2.4.13  Weigh Sensor HX711 ===
... ... @@ -1387,7 +1387,6 @@
1387 1387  |(% style="width:184px" %)INTMOD|(% style="width:76px" %)Any|(% style="width:98px" %)06|(% style="width:150px" %)4
1388 1388  |(% style="width:184px" %)RESET THE FACTORY DEFAULT|(% style="width:76px" %)Any|(% style="width:98px" %)04|(% style="width:150px" %)2
1389 1389  