<
From version < 97.8 >
edited by Xiaoling
on 2022/07/09 11:26
To version < 92.2 >
edited by Xiaoling
on 2022/07/09 10:02
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -7,7 +7,6 @@
7 7  
8 8  **Table of Contents:**
9 9  
10 -{{toc/}}
11 11  
12 12  
13 13  
... ... @@ -33,6 +33,9 @@
33 33  
34 34  )))
35 35  
35 +[[image:1654503236291-817.png]]
36 +
37 +
36 36  [[image:1657327959271-447.png]]
37 37  
38 38  
... ... @@ -54,7 +54,6 @@
54 54  * 8500mAh Battery for long term use
55 55  
56 56  
57 -
58 58  == 1.3  Specification ==
59 59  
60 60  
... ... @@ -83,7 +83,7 @@
83 83  (% style="color:#037691" %)**Power Consumption**
84 84  
85 85  * STOP Mode: 10uA @ 3.3v
86 -* Max transmit power: 350mA@3.3v
87 +* Max transmit power: [[350mA@3.3v>>mailto:350mA@3.3v]]
87 87  
88 88  
89 89  
... ... @@ -100,6 +100,7 @@
100 100  ​
101 101  
102 102  
104 +
103 103  == 1.5  Pin Definitions ==
104 104  
105 105  
... ... @@ -232,9 +232,9 @@
232 232  === 2.2.5 Use UDP protocol to uplink data(Default protocol) ===
233 233  
234 234  
235 -* (% style="color:blue" %)**AT+PRO=2   ** (%%) ~/~/ Set to use UDP protocol to uplink
237 +* (% style="color:blue" %)**AT+PRO=2   ** (%%) ~/~/ Set to use UDP protocol to uplink
236 236  * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/ to set UDP server address and port
237 -* (% style="color:blue" %)**AT+CFM=1       ** (%%) ~/~/ If the server does not respond, this command is unnecessary
239 +* (% style="color:blue" %)**AT+CFM=1       ** (%%) ~/~/If the server does not respond, this command is unnecessary
238 238  
239 239  [[image:1657330501006-241.png]]
240 240  
... ... @@ -301,10 +301,10 @@
301 301  
302 302  
303 303  (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
304 -|=(% style="width: 80px;" %)(((
306 +|=(% style="width: 60px;" %)(((
305 305  **Size(bytes)**
306 -)))|=(% style="width: 80px;" %)**6**|=(% style="width: 35px;" %)2|=(% style="width: 35px;" %)**2**|=(% style="width: 110px;" %)**1**|=(% style="width: 110px;" %)**2**|=(% style="width: 70px;" %)**1**
307 -|(% style="width:97px" %)**Value**|(% style="width:83px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:41px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:123px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:120px" %)[[Distance (unit: mm)>>||anchor="H2.4.5A0Distance"]]|(% style="width:80px" %)[[Interrupt>>||anchor="H2.4.6A0DigitalInterrupt"]]
308 +)))|=(% style="width: 50px;" %)**6**|=(% style="width: 25px;" %)2|=(% style="width: 25px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 60px;" %)**2**|=(% style="width: 50px;" %)**1**
309 +|(% style="width:97px" %)**Value**|(% style="width:83px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:41px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:123px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:108px" %)[[Distance (unit: mm)>>||anchor="H2.4.5A0SoilMoisture"]]|(% style="width:80px" %)[[Interrupt>>||anchor="H2.4.8A0DigitalInterrupt"]]
308 308  
309 309  (((
310 310  If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NDDS751 uplink data.
... ... @@ -339,12 +339,9 @@
339 339  )))
340 340  * (((
341 341  Interrupt: 0x00 = 0
342 -
343 -
344 -
345 -
346 346  )))
347 347  
346 +
348 348  == 2.4  Payload Explanation and Sensor Interface ==
349 349  
350 350  
... ... @@ -387,6 +387,10 @@
387 387  === 2.4.3  Battery Info ===
388 388  
389 389  (((
389 +Check the battery voltage for LSE01.
390 +)))
391 +
392 +(((
390 390  Ex1: 0x0B45 = 2885mV
391 391  )))
392 392  
... ... @@ -428,7 +428,7 @@
428 428  
429 429  
430 430  
431 -=== 2.4.5  Distance ===
434 +=== 2.4.5  Soil Moisture ===
432 432  
433 433  Get the distance. Flat object range 280mm - 7500mm.
434 434  
... ... @@ -572,33 +572,63 @@
572 572  
573 573  
574 574  
575 -== 2.7  ​Firmware Change Log ==
578 +== 2.7  Installation in Soil ==
576 576  
580 +__**Measurement the soil surface**__
577 577  
578 -Download URL & Firmware Change log
582 +(((
583 +Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting. [[https:~~/~~/img.alicdn.com/imgextra/i3/2005165265/O1CN010rj9Oh1olPsQxrdUK_!!2005165265.jpg>>url:https://img.alicdn.com/imgextra/i3/2005165265/O1CN010rj9Oh1olPsQxrdUK_!!2005165265.jpg]]
584 +)))
579 579  
586 +[[image:1657259653666-883.png]] ​
587 +
588 +
580 580  (((
581 -[[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NDDS75/Firmware/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/NDDS75/Firmware/]]
590 +
591 +
592 +(((
593 +Dig a hole with diameter > 20CM.
582 582  )))
583 583  
596 +(((
597 +Horizontal insert the probe to the soil and fill the hole for long term measurement.
598 +)))
599 +)))
584 584  
601 +[[image:1654506665940-119.png]]
602 +
603 +(((
604 +
605 +)))
606 +
607 +
608 +== 2.8  ​Firmware Change Log ==
609 +
610 +
611 +Download URL & Firmware Change log
612 +
613 +[[www.dragino.com/downloads/index.php?dir=NB-IoT/NSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN50/Firmware/]]
614 +
615 +
585 585  Upgrade Instruction: [[Upgrade_Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
586 586  
587 587  
588 588  
589 -== 2.8  ​Battery Analysis ==
620 +== 2.9  ​Battery Analysis ==
590 590  
591 -=== 2.8.1  ​Battery Type ===
622 +=== 2.9.1  ​Battery Type ===
592 592  
593 593  
594 594  (((
595 -The NDDS75 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
626 +The NSE01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
596 596  )))
597 597  
629 +
598 598  (((
599 599  The battery is designed to last for several years depends on the actually use environment and update interval. 
600 600  )))
601 601  
634 +
602 602  (((
603 603  The battery related documents as below:
604 604  )))
... ... @@ -608,12 +608,12 @@
608 608  * [[Lithium-ion Battery-Capacitor datasheet>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
609 609  
610 610  (((
611 -[[image:image-20220709101450-2.png]]
644 +[[image:image-20220708140453-6.png]]
612 612  )))
613 613  
614 614  
615 615  
616 -=== 2.8.2  Power consumption Analyze ===
649 +=== 2.9.2  Power consumption Analyze ===
617 617  
618 618  (((
619 619  Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
... ... @@ -647,11 +647,11 @@
647 647  And the Life expectation in difference case will be shown on the right.
648 648  )))
649 649  
650 -[[image:image-20220709110451-3.png]]
683 +[[image:image-20220708141352-7.jpeg]]
651 651  
652 652  
653 653  
654 -=== 2.8.3  ​Battery Note ===
687 +=== 2.9.3  ​Battery Note ===
655 655  
656 656  (((
657 657  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
... ... @@ -659,10 +659,10 @@
659 659  
660 660  
661 661  
662 -=== 2.8.4  Replace the battery ===
695 +=== 2.9.4  Replace the battery ===
663 663  
664 664  (((
665 -The default battery pack of NDDS75 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
698 +The default battery pack of NSE01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
666 666  )))
667 667  
668 668  
... ... @@ -677,7 +677,7 @@
677 677  The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
678 678  )))
679 679  
680 -[[image:1657333200519-600.png]]
713 +[[image:1657261278785-153.png]]
681 681  
682 682  
683 683  
... ... @@ -685,7 +685,7 @@
685 685  
686 686  == 4.1  Access AT Commands ==
687 687  
688 -See this link for detail: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NDDS75/>>url:http://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN50/]]
721 +See this link for detail: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NSE01/>>url:http://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN50/]]
689 689  
690 690  
691 691  AT+<CMD>?  : Help on <CMD>
... ... @@ -773,11 +773,18 @@
773 773  )))
774 774  
775 775  (((
776 -(% style="color:red" %)Notice, NDDS75 and LDDS75 share the same mother board. They use the same connection and method to update.
809 +(% style="color:red" %)Notice, NSE01 and LSE01 share the same mother board. They use the same connection and method to update.
777 777  )))
778 778  
779 779  
780 780  
814 +== 5.2  Can I calibrate NSE01 to different soil types? ==
815 +
816 +(((
817 +NSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].
818 +)))
819 +
820 +
781 781  = 6.  Trouble Shooting =
782 782  
783 783  == 6.1  ​Connection problem when uploading firmware ==
... ... @@ -805,7 +805,7 @@
805 805  = 7. ​ Order Info =
806 806  
807 807  
808 -Part Number**:** (% style="color:#4f81bd" %)**NSDDS75**
848 +Part Number**:** (% style="color:#4f81bd" %)**NSE01**
809 809  
810 810  
811 811  (% class="wikigeneratedid" %)
... ... @@ -820,7 +820,7 @@
820 820  
821 821  (% style="color:#037691" %)**Package Includes**:
822 822  
823 -* NSE01 NB-IoT Distance Detect Sensor Node x 1
863 +* NSE01 NB-IoT Soil Moisture & EC Sensor x 1
824 824  * External antenna x 1
825 825  )))
826 826  
... ... @@ -829,11 +829,8 @@
829 829  
830 830  (% style="color:#037691" %)**Dimension and weight**:
831 831  
832 -
833 -* Device Size: 13.0 x 5 x 4.5 cm
834 -* Device Weight: 150g
835 -* Package Size / pcs : 15 x 12x 5.5 cm
836 -* Weight / pcs : 220g
872 +* Size: 195 x 125 x 55 mm
873 +* Weight:   420g
837 837  )))
838 838  
839 839  (((
1657332990863-496.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -138.2 KB
Content
1657333200519-600.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -126.1 KB
Content
image-20220709101450-2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -138.5 KB
Content
image-20220709110451-3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Xiaoling
Size
... ... @@ -1,1 +1,0 @@
1 -611.5 KB
Content
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0