... ... @@ -69,6 +69,9 @@
69 69  * Micro SIM card slot for NB-IoT SIM
70 70  * 8500mAh Battery for long term use
71 71  
72 +
73 +
74 +
72 72  == 1.3  Specification ==
73 73  
74 74  
... ... @@ -524,14 +524,22 @@
524 524  
525 525  === 2.4.9  ​+5V Output ===
526 526  
530 +(((
527 527  NSE01 will enable +5V output before all sampling and disable the +5v after all sampling. 
532 +)))
528 528  
529 529  
535 +(((
530 530  The 5V output time can be controlled by AT Command.
537 +)))
531 531  
539 +(((
532 532  (% style="color:blue" %)**AT+5VT=1000**
541 +)))
533 533  
543 +(((
534 534  Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.
545 +)))
535 535  
536 536  
537 537  
... ... @@ -581,7 +581,9 @@
581 581  
582 582  * (% style="color:blue" %)**INTMOD**
583 583  
595 +(((
584 584  Downlink Payload: 06000003, Set AT+INTMOD=3
597 +)))
585 585  
586 586  
587 587  
... ... @@ -604,7 +604,9 @@
604 604  
605 605  __**Measurement the soil surface**__
606 606  
620 +(((
607 607  Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting. [[https:~~/~~/img.alicdn.com/imgextra/i3/2005165265/O1CN010rj9Oh1olPsQxrdUK_!!2005165265.jpg>>url:https://img.alicdn.com/imgextra/i3/2005165265/O1CN010rj9Oh1olPsQxrdUK_!!2005165265.jpg]]
622 +)))
608 608  
609 609  [[image:1657259653666-883.png]] ​
610 610  
... ... @@ -645,13 +645,19 @@
645 645  === 2.9.1  ​Battery Type ===
646 646  
647 647  
663 +(((
648 648  The NSE01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
665 +)))
649 649  
650 650  
668 +(((
651 651  The battery is designed to last for several years depends on the actually use environment and update interval. 
670 +)))
652 652  
653 653  
673 +(((
654 654  The battery related documents as below:
675 +)))
655 655  
656 656  * [[Battery Dimension>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
657 657  * [[Lithium-Thionyl Chloride Battery datasheet>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
... ... @@ -828,26 +828,37 @@
828 828  
829 829  
830 830  
852 +== 5.2  Can I calibrate NSE01 to different soil types? ==
853 +
854 +(((
855 +NSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].
856 +)))
857 +
858 +
831 831  = 6.  Trouble Shooting =
832 832  
833 833  == 6.1  ​Connection problem when uploading firmware ==
834 834  
835 835  
864 +(((
865 +**Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
866 +)))
867 +
836 836  (% class="wikigeneratedid" %)
837 837  (((
838 -(% style="font-size:14px" %)**Please see: **(%%)[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting||style="background-color: rgb(255, 255, 255); font-size: 14px;"]]
870 +
839 839  )))
840 840  
841 841  
842 -
843 843  == 6.2  AT Command input doesn't work ==
844 844  
845 845  (((
846 846  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
878 +
879 +
847 847  )))
848 848  
849 849  
850 -
851 851  = 7. ​ Order Info =
852 852  
853 853  
... ... @@ -866,7 +866,6 @@
866 866  
867 867  (% style="color:#037691" %)**Package Includes**:
868 868  
869 -
870 870  * NSE01 NB-IoT Soil Moisture & EC Sensor x 1
871 871  * External antenna x 1
872 872  )))
... ... @@ -876,7 +876,6 @@
876 876  
877 877  (% style="color:#037691" %)**Dimension and weight**:
878 878  
879 -
880 880  * Size: 195 x 125 x 55 mm
881 881  * Weight:   420g