24 24  = 1.  Introduction =
25 25  
26 26  == 1.1 ​ What is LoRaWAN Soil Moisture & EC Sensor ==
... ... @@ -28,21 +28,13 @@
28 28  (((
29 29  
30 30  
31 -(((
32 32  Dragino NSE01 is an (% style="color:blue" %)**NB-IOT soil moisture & EC sensor**(%%) for agricultural IoT. Used to measure the soil moisture of saline-alkali soil and loam. The soil sensor uses the FDR method to calculate soil moisture and compensates it with soil temperature and electrical conductivity. It has also been calibrated for mineral soil types at the factory.
33 -)))
34 34  
35 -(((
36 36  It can detect (% style="color:blue" %)**Soil Moisture, Soil Temperature and Soil Conductivity**(%%), and upload its value to the server wirelessly.
37 -)))
38 38  
39 -(((
40 40  The wireless technology used in NSE01 allows the device to send data at a low data rate and reach ultra-long distances, providing ultra-long-distance spread spectrum Communication.
41 -)))
42 42  
43 -(((
44 44  NSE01 are powered by (% style="color:blue" %)**8500mAh Li-SOCI2**(%%) batteries, which can be used for up to 5 years.  
45 -)))
46 46  
47 47  
48 48  )))
... ... @@ -54,8 +54,9 @@
54 54  
55 55  
56 56  
57 -== 1.2 ​ Features ==
46 +== 1.2 ​Features ==
58 58  
48 +
59 59  * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD
60 60  * Monitor Soil Moisture
61 61  * Monitor Soil Temperature
... ... @@ -69,7 +69,6 @@
69 69  * Micro SIM card slot for NB-IoT SIM
70 70  * 8500mAh Battery for long term use
71 71  
72 -
73 73  == 1.3  Specification ==
74 74  
75 75  
... ... @@ -87,7 +87,7 @@
87 87  * - B20 @H-FDD: 800MHz
88 88  * - B28 @H-FDD: 700MHz
89 89  
90 -Probe(% style="color:#037691" %)** Specification:**
79 +(% style="color:#037691" %)**Probe Specification:**
91 91  
92 92  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
93 93  
... ... @@ -137,9 +137,7 @@
137 137  === 2.2.1 Test Requirement ===
138 138  
139 139  
140 -(((
141 141  To use NSE01 in your city, make sure meet below requirements:
142 -)))
143 143  
144 144  * Your local operator has already distributed a NB-IoT Network there.
145 145  * The local NB-IoT network used the band that NSE01 supports.
... ... @@ -303,7 +303,7 @@
303 303  |=(% style="width: 50px;" %)(((
304 304  **Size(bytes)**
305 305  )))|=(% style="width: 50px;" %)**6**|=(% style="width: 25px;" %)2|=(% style="width: 25px;" %)**2**|=(% style="width: 80px;" %)**1**|=(% style="width: 80px;" %)**2**|=(% style="width: 80px;" %)**2**|=(% style="width: 80px;" %)**2**|=(% style="width: 40px;" %)**1**
306 -|(% style="width:97px" %)**Value**|(% style="width:83px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:41px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:123px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:108px" %)[[Soil Moisture>>||anchor="H2.4.5A0SoilMoisture"]]|(% style="width:133px" %)[[Soil Temperature>>||anchor="H2.4.6A0SoilTemperature"]]|(% style="width:159px" %)[[Soil Conductivity(EC)>>||anchor="H2.4.7A0SoilConductivity28EC29"]]|(% style="width:80px" %)[[Interrupt>>||anchor="H2.4.8A0DigitalInterrupt"]]
293 +|(% style="width:97px" %)**Value**|(% style="width:83px" %)[[Device ID>>||anchor="H"]]|(% style="width:41px" %)[[Ver>>||anchor="H"]]|(% style="width:46px" %)[[BAT>>||anchor="H"]]|(% style="width:123px" %)[[Signal Strength>>||anchor="H"]]|(% style="width:108px" %)[[Soil Moisture>>||anchor="H"]]|(% style="width:133px" %)[[Soil Temperature>>||anchor="H"]]|(% style="width:159px" %)[[Soil Conductivity(EC)>>||anchor="H"]]|(% style="width:80px" %)[[Interrupt>>||anchor="H"]]
307 307  
308 308  If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NSE01 uplink data.
309 309  
... ... @@ -325,7 +325,6 @@
325 325  * Soil Conductivity(EC) = 0x02f9 =761 uS /cm
326 326  * Interrupt: 0x00 = 0
327 327  
328 -
329 329  == 2.4  Payload Explanation and Sensor Interface ==
330 330  
331 331  
... ... @@ -456,7 +456,7 @@
456 456  (% style="color:blue" %)**AT+INTMOD=3 **(%%) ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.**
457 457  
458 458  
459 -The lower four bits of this data field shows if this packet is generated by interrupt or not. Click here for the hardware and software set up.
445 +The lower four bits of this data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H"]] for the hardware and software set up.
460 460  
461 461  
462 462  Example:
... ... @@ -581,7 +581,7 @@
581 581  [[www.dragino.com/downloads/index.php?dir=NB-IoT/NSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN50/Firmware/]]
582 582  
583 583  
584 -Upgrade Instruction: [[Upgrade_Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
570 +Upgrade Instruction: [[Upgrade_Firmware>>||anchor="H"]]
585 585  
586 586  
587 587  
... ... @@ -599,7 +599,7 @@
599 599  The battery related documents as below:
600 600  
601 601  * [[Battery Dimension>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
602 -* [[Lithium-Thionyl Chloride Battery datasheet>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
588 +* [[Lithium-Thionyl Chloride Battery>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]][[ datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
603 603  * [[Lithium-ion Battery-Capacitor datasheet>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
604 604  
605 605  (((
... ... @@ -754,66 +754,155 @@
754 754  
755 755  
756 756  
757 -= ​5.  FAQ =
743 += ​4. FAQ =
758 758  
759 -== 5.1 ​ How to Upgrade Firmware ==
745 +== 4.1 ​How to change the LoRa Frequency Bands/Region? ==
760 760  
747 +(((
748 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
749 +When downloading the images, choose the required image file for download. ​
750 +)))
761 761  
762 762  (((
763 -User can upgrade the firmware for 1) bug fix, 2) new feature release.
753 +
764 764  )))
765 765  
766 766  (((
767 -Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
757 +How to set up LSE01 to work in 8 channel mode By default, the frequency bands US915, AU915, CN470 work in 72 frequencies. Many gateways are 8 channel gateways, and in this case, the OTAA join time and uplink schedule is long and unpredictable while the end node is hopping in 72 frequencies.
768 768  )))
769 769  
770 770  (((
771 -(% style="color:red" %)Notice, NSE01 and LSE01 share the same mother board. They use the same connection and method to update.
761 +
772 772  )))
773 773  
764 +(((
765 +You can configure the end node to work in 8 channel mode by using the AT+CHE command. The 500kHz channels are always included for OTAA.
766 +)))
774 774  
768 +(((
769 +
770 +)))
775 775  
776 -= 6.  Trouble Shooting =
772 +(((
773 +For example, in **US915** band, the frequency table is as below. By default, the end node will use all channels (0~~71) for OTAA Join process. After the OTAA Join, the end node will use these all channels (0~~71) to send uplink packets.
774 +)))
777 777  
778 -== 6.1  ​Connection problem when uploading firmware ==
776 +[[image:image-20220606154726-3.png]]
779 779  
780 780  
781 -(% class="wikigeneratedid" %)
779 +When you use the TTN network, the US915 frequency bands use are:
780 +
781 +* 903.9 - SF7BW125 to SF10BW125
782 +* 904.1 - SF7BW125 to SF10BW125
783 +* 904.3 - SF7BW125 to SF10BW125
784 +* 904.5 - SF7BW125 to SF10BW125
785 +* 904.7 - SF7BW125 to SF10BW125
786 +* 904.9 - SF7BW125 to SF10BW125
787 +* 905.1 - SF7BW125 to SF10BW125
788 +* 905.3 - SF7BW125 to SF10BW125
789 +* 904.6 - SF8BW500
790 +
782 782  (((
783 -(% style="font-size:14px" %)**Please see: **(%%)[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting||style="background-color: rgb(255, 255, 255); font-size: 14px;"]]
792 +Because the end node is now hopping in 72 frequency, it makes it difficult for the devices to Join the TTN network and uplink data. To solve this issue, you can access the device via the AT commands and run:
793 +
794 +* (% style="color:#037691" %)**AT+CHE=2**
795 +* (% style="color:#037691" %)**ATZ**
784 784  )))
785 785  
798 +(((
799 +
786 786  
801 +to set the end node to work in 8 channel mode. The device will work in Channel 8-15 & 64-71 for OTAA, and channel 8-15 for Uplink.
802 +)))
787 787  
788 -== 6.2  AT Command input doesn't work ==
804 +(((
805 +
806 +)))
789 789  
790 790  (((
809 +The **AU915** band is similar. Below are the AU915 Uplink Channels.
810 +)))
811 +
812 +[[image:image-20220606154825-4.png]]
813 +
814 +
815 +== 4.2 ​Can I calibrate LSE01 to different soil types? ==
816 +
817 +LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]].
818 +
819 +
820 += 5. Trouble Shooting =
821 +
822 +== 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
823 +
824 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
825 +
826 +
827 +== 5.2 AT Command input doesn't work ==
828 +
829 +(((
791 791  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
792 792  )))
793 793  
794 794  
834 +== 5.3 Device rejoin in at the second uplink packet ==
795 795  
796 -= 7. ​ Order Info =
836 +(% style="color:#4f81bd" %)**Issue describe as below:**
797 797  
838 +[[image:1654500909990-784.png]]
798 798  
799 -Part Number**:** (% style="color:#4f81bd" %)**NSE01**
800 800  
841 +(% style="color:#4f81bd" %)**Cause for this issue:**
801 801  
843 +(((
844 +The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
845 +)))
846 +
847 +
848 +(% style="color:#4f81bd" %)**Solution: **
849 +
850 +All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
851 +
852 +[[image:1654500929571-736.png||height="458" width="832"]]
853 +
854 +
855 += 6. ​Order Info =
856 +
857 +
858 +Part Number**:** (% style="color:#4f81bd" %)**LSE01-XX-YY**
859 +
860 +
861 +(% style="color:#4f81bd" %)**XX**(%%)**:** The default frequency band
862 +
863 +* (% style="color:red" %)**AS923**(%%): LoRaWAN AS923 band
864 +* (% style="color:red" %)**AU915**(%%): LoRaWAN AU915 band
865 +* (% style="color:red" %)**EU433**(%%): LoRaWAN EU433 band
866 +* (% style="color:red" %)**EU868**(%%): LoRaWAN EU868 band
867 +* (% style="color:red" %)**KR920**(%%): LoRaWAN KR920 band
868 +* (% style="color:red" %)**US915**(%%): LoRaWAN US915 band
869 +* (% style="color:red" %)**IN865**(%%):  LoRaWAN IN865 band
870 +* (% style="color:red" %)**CN470**(%%): LoRaWAN CN470 band
871 +
872 +(% style="color:#4f81bd" %)**YY**(%%)**: **Battery Option
873 +
874 +* (% style="color:red" %)**4**(%%): 4000mAh battery
875 +* (% style="color:red" %)**8**(%%): 8500mAh battery
876 +
802 802  (% class="wikigeneratedid" %)
803 803  (((
804 804  
805 805  )))
806 806  
807 -= 8.  Packing Info =
882 += 7. Packing Info =
808 808  
809 809  (((
810 810  
811 811  
812 812  (% style="color:#037691" %)**Package Includes**:
888 +)))
813 813  
814 -
815 -* NSE01 NB-IoT Soil Moisture & EC Sensor x 1
816 -* External antenna x 1
890 +* (((
891 +LSE01 LoRaWAN Soil Moisture & EC Sensor x 1
817 817  )))
818 818  
819 819  (((
... ... @@ -820,20 +820,24 @@
820 820  
821 821  
822 822  (% style="color:#037691" %)**Dimension and weight**:
898 +)))
823 823  
824 -
825 -* Size: 195 x 125 x 55 mm
826 -* Weight:   420g
900 +* (((
901 +Device Size: cm
827 827  )))
903 +* (((
904 +Device Weight: g
905 +)))
906 +* (((
907 +Package Size / pcs : cm
908 +)))
909 +* (((
910 +Weight / pcs : g
828 828  
829 -(((
830 830  
831 -
832 -
833 -
834 834  )))
835 835  
836 -= 9.  Support =
915 += 8. Support =
837 837  
838 838  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
839 839  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0