From version < 57.7 >
edited by Xiaoling
on 2022/07/08 11:54
To version < 59.1 >
edited by Xiaoling
on 2022/07/08 13:54
>
Change comment: Uploaded new attachment "1657259653666-883.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -313,7 +313,6 @@
313 313  * Interrupt: 0x00 = 0
314 314  
315 315  
316 -
317 317  == 2.4  Payload Explanation and Sensor Interface ==
318 318  
319 319  
... ... @@ -437,11 +437,11 @@
437 437  
438 438  === 2.4.8  Digital Interrupt ===
439 439  
440 -Digital Interrupt refers to pin **(% style="color:blue" %)GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSE01 will send a packet to the server.
439 +Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NSE01 will send a packet to the server.
441 441  
442 442  The command is:
443 443  
444 -**(% style="color:blue" %)AT+INTMOD=3 **(%%)   ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]]**).**
443 +(% style="color:blue" %)**AT+INTMOD=3 **(%%) ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.**
445 445  
446 446  
447 447  The lower four bits of this data field shows if this packet is generated by interrupt or not. [[Click here>>||anchor="H"]] for the hardware and software set up.
... ... @@ -455,10 +455,8 @@
455 455  
456 456  
457 457  
458 -
459 459  === 2.4.9  ​+5V Output ===
460 460  
461 -
462 462  NSE01 will enable +5V output before all sampling and disable the +5v after all sampling. 
463 463  
464 464  
... ... @@ -470,19 +470,14 @@
470 470  
471 471  
472 472  
473 -== 2.4 Uplink Interval ==
470 +== 2. Downlink Payload ==
474 474  
475 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
476 -
477 -
478 -
479 -== 2.5 Downlink Payload ==
480 -
481 481  By default, LSE50 prints the downlink payload to console port.
482 482  
483 -[[image:image-20220606165544-8.png]]
474 +[[image:image-20220708133731-5.png]]
484 484  
485 485  
477 +
486 486  (((
487 487  (% style="color:blue" %)**Examples:**
488 488  )))
1657259653666-883.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +344.4 KB
Content
image-20220708133731-5.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +8.7 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0