<
From version < 35.9 >
edited by Xiaoling
on 2022/06/14 14:04
To version < 35.19 >
edited by Xiaoling
on 2022/06/14 14:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -60,8 +60,6 @@
60 60  * IP66 Waterproof Enclosure
61 61  * 4000mAh or 8500mAh Battery for long term use
62 62  
63 -
64 -
65 65  == 1.3 Specification ==
66 66  
67 67  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -173,8 +173,6 @@
173 173  
174 174  
175 175  
176 -
177 -
178 178  === 2.3.2 MOD~=1(Original value) ===
179 179  
180 180  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -195,6 +195,8 @@
195 195  (Optional)
196 196  )))
197 197  
194 +
195 +
198 198  === 2.3.3 Battery Info ===
199 199  
200 200  (((
... ... @@ -302,11 +302,10 @@
302 302  )))
303 303  
304 304  (((
305 -LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
303 +LSE01 TTN Payload Decoder: [[https:~~/~~/www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0>>https://www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0]]
306 306  )))
307 307  
308 308  
309 -
310 310  == 2.4 Uplink Interval ==
311 311  
312 312  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
... ... @@ -374,11 +374,11 @@
374 374  )))
375 375  
376 376  (((
377 -**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
374 +(% style="color:blue" %)**Step 1**(%%):  Be sure that your device is programmed and properly connected to the network at this time.
378 378  )))
379 379  
380 380  (((
381 -**Step 2**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
378 +(% style="color:blue" %)**Step 2**(%%):  To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
382 382  )))
383 383  
384 384  
... ... @@ -387,11 +387,12 @@
387 387  
388 388  [[image:1654505874829-548.png]]
389 389  
390 -Step 3: Create an account or log in Datacake.
391 391  
392 -Step 4: Search the LSE01 and add DevEUI.
388 +(% style="color:blue" %)**Step 3**(%%)**:**  Create an account or log in Datacake.
393 393  
390 +(% style="color:blue" %)**Step 4**(%%)**:**  Search the LSE01 and add DevEUI.
394 394  
392 +
395 395  [[image:1654505905236-553.png]]
396 396  
397 397  
... ... @@ -687,6 +687,9 @@
687 687  * Solid ON for 5 seconds once device successful Join the network.
688 688  * Blink once when device transmit a packet.
689 689  
688 +
689 +
690 +
690 690  == 2.9 Installation in Soil ==
691 691  
692 692  **Measurement the soil surface**
... ... @@ -701,6 +701,7 @@
701 701  )))
702 702  
703 703  
705 +
704 704  [[image:1654506665940-119.png]]
705 705  
706 706  (((
... ... @@ -980,19 +980,14 @@
980 980  
981 981  (((
982 982  Because the end node is now hopping in 72 frequency, it makes it difficult for the devices to Join the TTN network and uplink data. To solve this issue, you can access the device via the AT commands and run:
983 -)))
984 984  
985 -(% class="box infomessage" %)
986 -(((
987 -**AT+CHE=2**
986 +* **AT+CHE=2**
987 +* **ATZ**
988 988  )))
989 989  
990 -(% class="box infomessage" %)
991 991  (((
992 -**ATZ**
993 -)))
991 +
994 994  
995 -(((
996 996  to set the end node to work in 8 channel mode. The device will work in Channel 8-15 & 64-71 for OTAA, and channel 8-15 for Uplink.
997 997  )))
998 998  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0