From version < 35.8 >
edited by Xiaoling
on 2022/06/14 14:03
To version < 40.7 >
edited by Xiaoling
on 2022/06/30 11:12
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,6 +3,14 @@
3 3  
4 4  
5 5  
6 +
7 +
8 +
9 +
10 +
11 +
12 +
13 +
6 6  **Table of Contents:**
7 7  
8 8  {{toc/}}
... ... @@ -60,8 +60,6 @@
60 60  * IP66 Waterproof Enclosure
61 61  * 4000mAh or 8500mAh Battery for long term use
62 62  
63 -
64 -
65 65  == 1.3 Specification ==
66 66  
67 67  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -298,11 +298,10 @@
298 298  )))
299 299  
300 300  (((
301 -LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
307 +LSE01 TTN Payload Decoder: [[https:~~/~~/www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0>>https://www.dropbox.com/sh/si8icbrjlamxqdb/AAACYwjsxxr5fj_vpqRtrETAa?dl=0]]
302 302  )))
303 303  
304 304  
305 -
306 306  == 2.4 Uplink Interval ==
307 307  
308 308  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
... ... @@ -317,7 +317,7 @@
317 317  
318 318  
319 319  (((
320 -**Examples:**
325 +(% style="color:blue" %)**Examples:**
321 321  )))
322 322  
323 323  (((
... ... @@ -325,7 +325,7 @@
325 325  )))
326 326  
327 327  * (((
328 -**Set TDC**
333 +(% style="color:blue" %)**Set TDC**
329 329  )))
330 330  
331 331  (((
... ... @@ -345,7 +345,7 @@
345 345  )))
346 346  
347 347  * (((
348 -**Reset**
353 +(% style="color:blue" %)**Reset**
349 349  )))
350 350  
351 351  (((
... ... @@ -353,7 +353,7 @@
353 353  )))
354 354  
355 355  
356 -* **CFM**
361 +* (% style="color:blue" %)**CFM**
357 357  
358 358  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
359 359  
... ... @@ -370,11 +370,11 @@
370 370  )))
371 371  
372 372  (((
373 -**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
378 +(% style="color:blue" %)**Step 1**(%%):  Be sure that your device is programmed and properly connected to the network at this time.
374 374  )))
375 375  
376 376  (((
377 -**Step 2**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
382 +(% style="color:blue" %)**Step 2**(%%):  To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
378 378  )))
379 379  
380 380  
... ... @@ -383,11 +383,12 @@
383 383  
384 384  [[image:1654505874829-548.png]]
385 385  
386 -Step 3: Create an account or log in Datacake.
387 387  
388 -Step 4: Search the LSE01 and add DevEUI.
392 +(% style="color:blue" %)**Step 3**(%%)**:**  Create an account or log in Datacake.
389 389  
394 +(% style="color:blue" %)**Step 4**(%%)**:**  Search the LSE01 and add DevEUI.
390 390  
396 +
391 391  [[image:1654505905236-553.png]]
392 392  
393 393  
... ... @@ -683,6 +683,7 @@
683 683  * Solid ON for 5 seconds once device successful Join the network.
684 684  * Blink once when device transmit a packet.
685 685  
692 +
686 686  == 2.9 Installation in Soil ==
687 687  
688 688  **Measurement the soil surface**
... ... @@ -697,6 +697,7 @@
697 697  )))
698 698  
699 699  
707 +
700 700  [[image:1654506665940-119.png]]
701 701  
702 702  (((
... ... @@ -758,13 +758,13 @@
758 758  )))
759 759  
760 760  * (((
761 -[[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
769 +[[Battery Dimension>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
762 762  )))
763 763  * (((
764 -[[Lithium-Thionyl Chloride Battery  datasheet>>url:https://www.dragino.com/downloads/downloads/datasheet/Battery/ER26500/ER26500_Datasheet-EN.pdf]],
772 +[[Lithium-Thionyl Chloride Battery  datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]],
765 765  )))
766 766  * (((
767 -[[Lithium-ion Battery-Capacitor datasheet>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC_1520_datasheet.jpg]], [[Tech Spec>>url:http://www.dragino.com/downloads/downloads/datasheet/Battery/SPC1520%20Technical%20Specification20171123.pdf]]
775 +[[Lithium-ion Battery-Capacitor datasheet>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]], [[Tech Spec>>https://www.dragino.com/downloads/index.php?dir=datasheet/Battery/]]
768 768  )))
769 769  
770 770   [[image:image-20220610172436-1.png]]
... ... @@ -818,7 +818,7 @@
818 818   [[image:1654502050864-459.png||height="564" width="806"]]
819 819  
820 820  
821 -Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
829 +Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]: [[https:~~/~~/www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]
822 822  
823 823  
824 824  (% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>? **(%%) : Help on <CMD>
... ... @@ -976,19 +976,14 @@
976 976  
977 977  (((
978 978  Because the end node is now hopping in 72 frequency, it makes it difficult for the devices to Join the TTN network and uplink data. To solve this issue, you can access the device via the AT commands and run:
979 -)))
980 980  
981 -(% class="box infomessage" %)
982 -(((
983 -**AT+CHE=2**
988 +* (% style="color:#037691" %)**AT+CHE=2**
989 +* (% style="color:#037691" %)**ATZ**
984 984  )))
985 985  
986 -(% class="box infomessage" %)
987 987  (((
988 -**ATZ**
989 -)))
993 +
990 990  
991 -(((
992 992  to set the end node to work in 8 channel mode. The device will work in Channel 8-15 & 64-71 for OTAA, and channel 8-15 for Uplink.
993 993  )))
994 994  
... ... @@ -1003,18 +1003,22 @@
1003 1003  [[image:image-20220606154825-4.png]]
1004 1004  
1005 1005  
1009 +== 4.2 ​Can I calibrate LSE01 to different soil types? ==
1006 1006  
1011 +LSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/&file=Calibrate_to_other_Soil_20220605.pdf]].
1012 +
1013 +
1007 1007  = 5. Trouble Shooting =
1008 1008  
1009 -== 5.1 ​Why I cant join TTN in US915 / AU915 bands? ==
1016 +== 5.1 ​Why I can't join TTN in US915 / AU915 bands? ==
1010 1010  
1011 -It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.LoRaWAN Communication Debug.WebHome||anchor="H2.NoticeofUS9152FCN4702FAU915Frequencyband"]] section above for details.
1018 +It is due to channel mapping. Please see the [[Eight Channel Mode>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H7.19EightChannelMode"]] section above for details.
1012 1012  
1013 1013  
1014 -== 5.2 AT Command input doesnt work ==
1021 +== 5.2 AT Command input doesn't work ==
1015 1015  
1016 1016  (((
1017 -In the case if user can see the console output but cant type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesnt send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1024 +In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1018 1018  )))
1019 1019  
1020 1020  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0