From version < 35.25 >
edited by Xiaoling
on 2022/06/25 16:23
To version < 35.17 >
edited by Xiaoling
on 2022/06/14 14:13
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,14 +3,6 @@
3 3  
4 4  
5 5  
6 -
7 -
8 -
9 -
10 -
11 -
12 -
13 -
14 14  **Table of Contents:**
15 15  
16 16  {{toc/}}
... ... @@ -68,11 +68,6 @@
68 68  * IP66 Waterproof Enclosure
69 69  * 4000mAh or 8500mAh Battery for long term use
70 70  
71 -
72 -
73 -
74 -
75 -
76 76  == 1.3 Specification ==
77 77  
78 78  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -182,6 +182,8 @@
182 182  (Optional)
183 183  )))
184 184  
172 +
173 +
185 185  === 2.3.2 MOD~=1(Original value) ===
186 186  
187 187  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -202,6 +202,8 @@
202 202  (Optional)
203 203  )))
204 204  
194 +
195 +
205 205  === 2.3.3 Battery Info ===
206 206  
207 207  (((
... ... @@ -695,6 +695,8 @@
695 695  * Blink once when device transmit a packet.
696 696  
697 697  
689 +
690 +
698 698  == 2.9 Installation in Soil ==
699 699  
700 700  **Measurement the soil surface**
... ... @@ -709,7 +709,6 @@
709 709  )))
710 710  
711 711  
712 -
713 713  [[image:1654506665940-119.png]]
714 714  
715 715  (((
... ... @@ -831,7 +831,7 @@
831 831   [[image:1654502050864-459.png||height="564" width="806"]]
832 832  
833 833  
834 -Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]: [[https:~~/~~/www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0>>https://www.dropbox.com/sh/qr6vproz4z4kzjz/AAAD48h3OyWrU1hq_Cqm8jIwa?dl=0]]
826 +Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
835 835  
836 836  
837 837  (% style="background-color:#dcdcdc" %)**AT+<CMD>=?AT+<CMD>? **(%%) : Help on <CMD>
... ... @@ -989,14 +989,19 @@
989 989  
990 990  (((
991 991  Because the end node is now hopping in 72 frequency, it makes it difficult for the devices to Join the TTN network and uplink data. To solve this issue, you can access the device via the AT commands and run:
984 +)))
992 992  
993 -* (% style="color:#037691" %)**AT+CHE=2**
994 -* (% style="color:#037691" %)**ATZ**
986 +(% class="box infomessage" %)
987 +(((
988 +**AT+CHE=2**
995 995  )))
996 996  
991 +(% class="box infomessage" %)
997 997  (((
998 -
993 +**ATZ**
994 +)))
999 999  
996 +(((
1000 1000  to set the end node to work in 8 channel mode. The device will work in Channel 8-15 & 64-71 for OTAA, and channel 8-15 for Uplink.
1001 1001  )))
1002 1002  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0