<
From version < 35.11 >
edited by Xiaoling
on 2022/06/14 14:06
To version < 35.20 >
edited by Xiaoling
on 2022/06/14 14:16
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -60,8 +60,6 @@
60 60  * IP66 Waterproof Enclosure
61 61  * 4000mAh or 8500mAh Battery for long term use
62 62  
63 -
64 -
65 65  == 1.3 Specification ==
66 66  
67 67  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -173,8 +173,6 @@
173 173  
174 174  
175 175  
176 -
177 -
178 178  === 2.3.2 MOD~=1(Original value) ===
179 179  
180 180  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -197,8 +197,6 @@
197 197  
198 198  
199 199  
200 -
201 -
202 202  === 2.3.3 Battery Info ===
203 203  
204 204  (((
... ... @@ -377,11 +377,11 @@
377 377  )))
378 378  
379 379  (((
380 -**Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
374 +(% style="color:blue" %)**Step 1**(%%):  Be sure that your device is programmed and properly connected to the network at this time.
381 381  )))
382 382  
383 383  (((
384 -**Step 2**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
378 +(% style="color:blue" %)**Step 2**(%%):  To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
385 385  )))
386 386  
387 387  
... ... @@ -390,11 +390,12 @@
390 390  
391 391  [[image:1654505874829-548.png]]
392 392  
393 -Step 3: Create an account or log in Datacake.
394 394  
395 -Step 4: Search the LSE01 and add DevEUI.
388 +(% style="color:blue" %)**Step 3**(%%)**:**  Create an account or log in Datacake.
396 396  
390 +(% style="color:blue" %)**Step 4**(%%)**:**  Search the LSE01 and add DevEUI.
397 397  
392 +
398 398  [[image:1654505905236-553.png]]
399 399  
400 400  
... ... @@ -690,6 +690,9 @@
690 690  * Solid ON for 5 seconds once device successful Join the network.
691 691  * Blink once when device transmit a packet.
692 692  
688 +
689 +
690 +
693 693  == 2.9 Installation in Soil ==
694 694  
695 695  **Measurement the soil surface**
... ... @@ -704,6 +704,7 @@
704 704  )))
705 705  
706 706  
705 +
707 707  [[image:1654506665940-119.png]]
708 708  
709 709  (((
... ... @@ -983,19 +983,14 @@
983 983  
984 984  (((
985 985  Because the end node is now hopping in 72 frequency, it makes it difficult for the devices to Join the TTN network and uplink data. To solve this issue, you can access the device via the AT commands and run:
986 -)))
987 987  
988 -(% class="box infomessage" %)
989 -(((
990 -**AT+CHE=2**
986 +* **(% style="color:#037691" %)AT+CHE=2**
987 +* **(% style="color:#037691" %)ATZ**
991 991  )))
992 992  
993 -(% class="box infomessage" %)
994 994  (((
995 -**ATZ**
996 -)))
991 +
997 997  
998 -(((
999 999  to set the end node to work in 8 channel mode. The device will work in Channel 8-15 & 64-71 for OTAA, and channel 8-15 for Uplink.
1000 1000  )))
1001 1001  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0