From version < 33.2 >
edited by Xiaoling
on 2022/06/07 11:43
To version < 31.41 >
edited by Xiaoling
on 2022/06/07 11:12
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -58,8 +58,6 @@
58 58  * IP66 Waterproof Enclosure
59 59  * 4000mAh or 8500mAh Battery for long term use
60 60  
61 -
62 -
63 63  == 1.3 Specification ==
64 64  
65 65  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -144,107 +144,88 @@
144 144  
145 145  == 2.3 Uplink Payload ==
146 146  
147 -=== ===
148 -
149 149  === 2.3.1 MOD~=0(Default Mode) ===
150 150  
151 151  LSE01 will uplink payload via LoRaWAN with below payload format: 
152 152  
153 -(((
149 +
154 154  Uplink payload includes in total 11 bytes.
155 -)))
151 +
156 156  
157 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
158 -|(((
153 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %)
154 +|=(((
159 159  **Size**
160 160  
161 161  **(bytes)**
162 -)))|**2**|**2**|**2**|**2**|**2**|**1**
163 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
158 +)))|=(% style="width: 50px;" %)**2**|=(% style="width: 80px;" %)**2**|=(% style="width: 80px;" %)**2**|=(% style="width: 80px;" %)**2**|=(% style="width: 80px;" %)**2**|=(% style="width: 80px;" %)**1**
159 +|**Value**|(% style="width:46px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:160px" %)(((
164 164  Temperature
165 165  
166 166  (Reserve, Ignore now)
167 -)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
163 +)))|(% style="width:104px" %)[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|(% style="width:126px" %)[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|(% style="width:159px" %)[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(% style="width:114px" %)(((
168 168  MOD & Digital Interrupt
169 169  
170 170  (Optional)
171 171  )))
172 172  
169 +[[image:1654504881641-514.png]]
173 173  
171 +
172 +
174 174  === 2.3.2 MOD~=1(Original value) ===
175 175  
176 176  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
177 177  
178 -(% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
179 -|(((
177 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %)
178 +|=(((
180 180  **Size**
181 181  
182 182  **(bytes)**
183 -)))|**2**|**2**|**2**|**2**|**2**|**1**
182 +)))|=**2**|=**2**|=**2**|=**2**|=**2**|=**1**
184 184  |**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
185 185  Temperature
186 186  
187 187  (Reserve, Ignore now)
188 -)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
187 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
189 189  MOD & Digital Interrupt
190 190  
191 191  (Optional)
192 192  )))
193 193  
193 +[[image:1654504907647-967.png]]
194 194  
195 +
196 +
195 195  === 2.3.3 Battery Info ===
196 196  
197 -(((
198 198  Check the battery voltage for LSE01.
199 -)))
200 200  
201 -(((
202 202  Ex1: 0x0B45 = 2885mV
203 -)))
204 204  
205 -(((
206 206  Ex2: 0x0B49 = 2889mV
207 -)))
208 208  
209 209  
210 210  
211 211  === 2.3.4 Soil Moisture ===
212 212  
213 -(((
214 214  Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
215 -)))
216 216  
217 -(((
218 218  For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
219 -)))
220 220  
221 -(((
222 -
223 -)))
224 224  
225 -(((
226 226  (% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
227 -)))
228 228  
229 229  
230 230  
231 231  === 2.3.5 Soil Temperature ===
232 232  
233 -(((
234 234   Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
235 -)))
236 236  
237 -(((
238 238  **Example**:
239 -)))
240 240  
241 -(((
242 242  If payload is 0105H: ((0x0105 & 0x8000)>>15 === 0),temp = 0105(H)/100 = 2.61 °C
243 -)))
244 244  
245 -(((
246 246  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
247 -)))
248 248  
249 249  
250 250  
... ... @@ -294,13 +294,9 @@
294 294  
295 295  [[image:1654505570700-128.png]]
296 296  
297 -(((
298 298  The payload decoder function for TTN is here:
299 -)))
300 300  
301 -(((
302 302  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
303 -)))
304 304  
305 305  
306 306  
... ... @@ -317,41 +317,21 @@
317 317  [[image:image-20220606165544-8.png]]
318 318  
319 319  
320 -(((
321 321  **Examples:**
322 -)))
323 323  
324 -(((
325 -
326 -)))
327 327  
328 -* (((
329 -**Set TDC**
330 -)))
298 +* **Set TDC**
331 331  
332 -(((
333 333  If the payload=0100003C, it means set the END Node’s TDC to 0x00003C=60(S), while type code is 01.
334 -)))
335 335  
336 -(((
337 337  Payload:    01 00 00 1E    TDC=30S
338 -)))
339 339  
340 -(((
341 341  Payload:    01 00 00 3C    TDC=60S
342 -)))
343 343  
344 -(((
345 -
346 -)))
347 347  
348 -* (((
349 -**Reset**
350 -)))
307 +* **Reset**
351 351  
352 -(((
353 353  If payload = 0x04FF, it will reset the LSE01
354 -)))
355 355  
356 356  
357 357  * **CFM**
... ... @@ -362,21 +362,12 @@
362 362  
363 363  == 2.6 ​Show Data in DataCake IoT Server ==
364 364  
365 -(((
366 366  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
367 -)))
368 368  
369 -(((
370 -
371 -)))
372 372  
373 -(((
374 374  **Step 1**: Be sure that your device is programmed and properly connected to the network at this time.
375 -)))
376 376  
377 -(((
378 378  **Step 2**: To configure the Application to forward data to DATACAKE you will need to add integration. To add the DATACAKE integration, perform the following steps:
379 -)))
380 380  
381 381  
382 382  [[image:1654505857935-743.png]]
... ... @@ -1098,6 +1098,7 @@
1098 1098  * (((
1099 1099  Weight / pcs : g
1100 1100  
1047 +
1101 1101  
1102 1102  )))
1103 1103  
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0