58 58  * IP66 Waterproof Enclosure
59 59  * 4000mAh or 8500mAh Battery for long term use
60 60  
61 +
61 61  == 1.3 Specification ==
62 62  
63 63  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -146,6 +146,7 @@
146 146  
147 147  LSE01 will uplink payload via LoRaWAN with below payload format: 
148 148  
150 +
149 149  Uplink payload includes in total 11 bytes.
150 150  
151 151  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
... ... @@ -154,11 +154,11 @@
154 154  
155 155  **(bytes)**
156 156  )))|**2**|**2**|**2**|**2**|**2**|**1**
157 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
159 +|**Value**|[[BAT>>path:#bat]]|(((
158 158  Temperature
159 159  
160 160  (Reserve, Ignore now)
161 -)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
163 +)))|[[Soil Moisture>>path:#soil_moisture]]|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]]|(((
162 162  MOD & Digital Interrupt
163 163  
164 164  (Optional)
... ... @@ -166,6 +166,8 @@
166 166  
167 167  
168 168  
171 +
172 +
169 169  === 2.3.2 MOD~=1(Original value) ===
170 170  
171 171  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -176,11 +176,11 @@
176 176  
177 177  **(bytes)**
178 178  )))|**2**|**2**|**2**|**2**|**2**|**1**
179 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
183 +|**Value**|[[BAT>>path:#bat]]|(((
180 180  Temperature
181 181  
182 182  (Reserve, Ignore now)
183 -)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
187 +)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((
184 184  MOD & Digital Interrupt
185 185  
186 186  (Optional)
... ... @@ -188,6 +188,7 @@
188 188  
189 189  
190 190  
195 +
191 191  === 2.3.3 Battery Info ===
192 192  
193 193  Check the battery voltage for LSE01.
... ... @@ -624,8 +624,6 @@
624 624  * Solid ON for 5 seconds once device successful Join the network.
625 625  * Blink once when device transmit a packet.
626 626  
627 -
628 -
629 629  == 2.9 Installation in Soil ==
630 630  
631 631  **Measurement the soil surface**
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved