From version < 32.10 >
edited by Xiaoling
on 2022/06/07 11:39
To version < 32.3 >
edited by Xiaoling
on 2022/06/07 11:28
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -58,6 +58,7 @@
58 58  * IP66 Waterproof Enclosure
59 59  * 4000mAh or 8500mAh Battery for long term use
60 60  
61 +
61 61  == 1.3 Specification ==
62 62  
63 63  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -142,16 +142,12 @@
142 142  
143 143  == 2.3 Uplink Payload ==
144 144  
145 -(% class="wikigeneratedid" %)
146 -=== ===
147 -
148 148  === 2.3.1 MOD~=0(Default Mode) ===
149 149  
150 150  LSE01 will uplink payload via LoRaWAN with below payload format: 
151 151  
152 -(((
150 +
153 153  Uplink payload includes in total 11 bytes.
154 -)))
155 155  
156 156  (% border="1" cellspacing="10" style="background-color:#ffffcc; width:500px" %)
157 157  |(((
... ... @@ -159,11 +159,11 @@
159 159  
160 160  **(bytes)**
161 161  )))|**2**|**2**|**2**|**2**|**2**|**1**
162 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
159 +|**Value**|[[BAT>>path:#bat]]|(((
163 163  Temperature
164 164  
165 165  (Reserve, Ignore now)
166 -)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(((
163 +)))|[[Soil Moisture>>path:#soil_moisture]]|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]]|(((
167 167  MOD & Digital Interrupt
168 168  
169 169  (Optional)
... ... @@ -171,6 +171,8 @@
171 171  
172 172  
173 173  
171 +
172 +
174 174  === 2.3.2 MOD~=1(Original value) ===
175 175  
176 176  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
... ... @@ -181,11 +181,11 @@
181 181  
182 182  **(bytes)**
183 183  )))|**2**|**2**|**2**|**2**|**2**|**1**
184 -|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
183 +|**Value**|[[BAT>>path:#bat]]|(((
185 185  Temperature
186 186  
187 187  (Reserve, Ignore now)
188 -)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]](raw)|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
187 +)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((
189 189  MOD & Digital Interrupt
190 190  
191 191  (Optional)
... ... @@ -193,39 +193,25 @@
193 193  
194 194  
195 195  
195 +
196 196  === 2.3.3 Battery Info ===
197 197  
198 -(((
199 199  Check the battery voltage for LSE01.
200 -)))
201 201  
202 -(((
203 203  Ex1: 0x0B45 = 2885mV
204 -)))
205 205  
206 -(((
207 207  Ex2: 0x0B49 = 2889mV
208 -)))
209 209  
210 210  
211 211  
212 212  === 2.3.4 Soil Moisture ===
213 213  
214 -(((
215 215  Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
216 -)))
217 217  
218 -(((
219 219  For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
220 -)))
221 221  
222 -(((
223 -
224 -)))
225 225  
226 -(((
227 227  (% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
228 -)))
229 229  
230 230  
231 231  
... ... @@ -644,8 +644,6 @@
644 644  * Solid ON for 5 seconds once device successful Join the network.
645 645  * Blink once when device transmit a packet.
646 646  
647 -
648 -
649 649  == 2.9 Installation in Soil ==
650 650  
651 651  **Measurement the soil surface**
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0