<
From version < 31.4 >
edited by Xiaoling
on 2022/06/06 17:23
To version < 31.36 >
edited by Xiaoling
on 2022/06/07 10:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1,13 +1,17 @@
1 1  (% style="text-align:center" %)
2 -[[image:image-20220606151504-2.jpeg||height="848" width="848"]]
2 +[[image:image-20220606151504-2.jpeg||height="554" width="554"]]
3 3  
4 4  
5 5  
6 +**Contents:**
6 6  
8 +{{toc/}}
7 7  
8 8  
9 9  
10 10  
13 +
14 +
11 11  = 1. Introduction =
12 12  
13 13  == 1.1 ​What is LoRaWAN Soil Moisture & EC Sensor ==
... ... @@ -54,6 +54,7 @@
54 54  * IP66 Waterproof Enclosure
55 55  * 4000mAh or 8500mAh Battery for long term use
56 56  
61 +
57 57  == 1.3 Specification ==
58 58  
59 59  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -85,7 +85,7 @@
85 85  )))
86 86  
87 87  (((
88 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.UsingtheATCommands"]].
93 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]].
89 89  )))
90 90  
91 91  
... ... @@ -146,16 +146,17 @@
146 146  Uplink payload includes in total 11 bytes.
147 147  
148 148  
149 -|(((
154 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %)
155 +|=(((
150 150  **Size**
151 151  
152 152  **(bytes)**
153 -)))|**2**|**2**|**2**|**2**|**2**|**1**
154 -|**Value**|[[BAT>>path:#bat]]|(((
159 +)))|=(% style="width: 46px;" %)**2**|=(% style="width: 160px;" %)**2**|=(% style="width: 104px;" %)**2**|=(% style="width: 126px;" %)**2**|=(% style="width: 159px;" %)**2**|=(% style="width: 114px;" %)**1**
160 +|**Value**|(% style="width:46px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:160px" %)(((
155 155  Temperature
156 156  
157 157  (Reserve, Ignore now)
158 -)))|[[Soil Moisture>>path:#soil_moisture]]|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]]|(((
164 +)))|(% style="width:104px" %)[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|(% style="width:126px" %)[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|(% style="width:159px" %)[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(% style="width:114px" %)(((
159 159  MOD & Digital Interrupt
160 160  
161 161  (Optional)
... ... @@ -169,16 +169,17 @@
169 169  
170 170  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
171 171  
172 -|(((
178 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %)
179 +|=(((
173 173  **Size**
174 174  
175 175  **(bytes)**
176 -)))|**2**|**2**|**2**|**2**|**2**|**1**
177 -|**Value**|[[BAT>>path:#bat]]|(((
183 +)))|=**2**|=**2**|=**2**|=**2**|=**2**|=**1**
184 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
178 178  Temperature
179 179  
180 180  (Reserve, Ignore now)
181 -)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((
188 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
182 182  MOD & Digital Interrupt
183 183  
184 184  (Optional)
... ... @@ -252,7 +252,7 @@
252 252  mod=(bytes[10]>>7)&0x01=1.
253 253  
254 254  
255 -Downlink Command:
262 +**Downlink Command:**
256 256  
257 257  If payload = 0x0A00, workmode=0
258 258  
... ... @@ -272,14 +272,13 @@
272 272  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
273 273  
274 274  
282 +
275 275  == 2.4 Uplink Interval ==
276 276  
277 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
285 +The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
278 278  
279 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
280 280  
281 281  
282 -
283 283  == 2.5 Downlink Payload ==
284 284  
285 285  By default, LSE50 prints the downlink payload to console port.
... ... @@ -626,6 +626,7 @@
626 626  * Blink once when device transmit a packet.
627 627  
628 628  
635 +
629 629  == 2.9 Installation in Soil ==
630 630  
631 631  **Measurement the soil surface**
... ... @@ -634,31 +634,52 @@
634 634  [[image:1654506634463-199.png]] ​
635 635  
636 636  (((
644 +(((
637 637  Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting.
638 638  )))
647 +)))
639 639  
640 640  
641 -
642 642  [[image:1654506665940-119.png]]
643 643  
652 +(((
644 644  Dig a hole with diameter > 20CM.
654 +)))
645 645  
656 +(((
646 646  Horizontal insert the probe to the soil and fill the hole for long term measurement.
658 +)))
647 647  
648 648  
649 649  == 2.10 ​Firmware Change Log ==
650 650  
663 +(((
651 651  **Firmware download link:**
665 +)))
652 652  
667 +(((
653 653  [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]]
669 +)))
654 654  
671 +(((
672 +
673 +)))
655 655  
675 +(((
656 656  **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]]
677 +)))
657 657  
679 +(((
680 +
681 +)))
658 658  
683 +(((
659 659  **V1.0.**
685 +)))
660 660  
687 +(((
661 661  Release
689 +)))
662 662  
663 663  
664 664  == 2.11 ​Battery Analysis ==
... ... @@ -665,15 +665,19 @@
665 665  
666 666  === 2.11.1 ​Battery Type ===
667 667  
696 +(((
668 668  The LSE01 battery is a combination of a 4000mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
698 +)))
669 669  
670 -
700 +(((
671 671  The battery is designed to last for more than 5 years for the LSN50.
702 +)))
672 672  
673 -
674 674  (((
705 +(((
675 675  The battery-related documents are as below:
676 676  )))
708 +)))
677 677  
678 678  * (((
679 679  [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]],
... ... @@ -720,13 +720,13 @@
720 720  
721 721  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
722 722  
723 -[[image:1654501986557-872.png]]
755 +[[image:1654501986557-872.png||height="391" width="800"]]
724 724  
725 725  
726 726  Or if you have below board, use below connection:
727 727  
728 728  
729 -[[image:1654502005655-729.png]]
761 +[[image:1654502005655-729.png||height="503" width="801"]]
730 730  
731 731  
732 732  
... ... @@ -733,7 +733,7 @@
733 733  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
734 734  
735 735  
736 - [[image:1654502050864-459.png]]
768 + [[image:1654502050864-459.png||height="564" width="806"]]
737 737  
738 738  
739 739  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
... ... @@ -848,20 +848,38 @@
848 848  
849 849  == 4.1 ​How to change the LoRa Frequency Bands/Region? ==
850 850  
851 -You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]].
883 +(((
884 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
852 852  When downloading the images, choose the required image file for download. ​
886 +)))
853 853  
888 +(((
889 +
890 +)))
854 854  
892 +(((
855 855  How to set up LSE01 to work in 8 channel mode By default, the frequency bands US915, AU915, CN470 work in 72 frequencies. Many gateways are 8 channel gateways, and in this case, the OTAA join time and uplink schedule is long and unpredictable while the end node is hopping in 72 frequencies.
894 +)))
856 856  
896 +(((
897 +
898 +)))
857 857  
900 +(((
858 858  You can configure the end node to work in 8 channel mode by using the AT+CHE command. The 500kHz channels are always included for OTAA.
902 +)))
859 859  
904 +(((
905 +
906 +)))
860 860  
908 +(((
861 861  For example, in **US915** band, the frequency table is as below. By default, the end node will use all channels (0~~71) for OTAA Join process. After the OTAA Join, the end node will use these all channels (0~~71) to send uplink packets.
910 +)))
862 862  
863 863  [[image:image-20220606154726-3.png]]
864 864  
914 +
865 865  When you use the TTN network, the US915 frequency bands use are:
866 866  
867 867  * 903.9 - SF7BW125 to SF10BW125
... ... @@ -904,7 +904,9 @@
904 904  
905 905  == 5.2 AT Command input doesn’t work ==
906 906  
957 +(((
907 907  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
959 +)))
908 908  
909 909  
910 910  == 5.3 Device rejoin in at the second uplink packet ==
... ... @@ -916,7 +916,9 @@
916 916  
917 917  (% style="color:#4f81bd" %)**Cause for this issue:**
918 918  
971 +(((
919 919  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
973 +)))
920 920  
921 921  
922 922  (% style="color:#4f81bd" %)**Solution: **
... ... @@ -923,7 +923,7 @@
923 923  
924 924  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
925 925  
926 -[[image:1654500929571-736.png]]
980 +[[image:1654500929571-736.png||height="458" width="832"]]
927 927  
928 928  
929 929  = 6. ​Order Info =
... ... @@ -948,6 +948,11 @@
948 948  * (% style="color:red" %)**4**(%%): 4000mAh battery
949 949  * (% style="color:red" %)**8**(%%): 8500mAh battery
950 950  
1005 +(% class="wikigeneratedid" %)
1006 +(((
1007 +
1008 +)))
1009 +
951 951  = 7. Packing Info =
952 952  
953 953  (((
... ... @@ -977,6 +977,9 @@
977 977  )))
978 978  * (((
979 979  Weight / pcs : g
1039 +
1040 +
1041 +
980 980  )))
981 981  
982 982  = 8. Support =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0