Changes for page N95S31B -- NB-IoT Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:44
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,13 +1,17 @@ 1 1 (% style="text-align:center" %) 2 -[[image:image-20220606151504-2.jpeg||height=" 848" width="848"]]2 +[[image:image-20220606151504-2.jpeg||height="554" width="554"]] 3 3 4 4 5 5 6 +**Contents:** 6 6 8 +{{toc/}} 7 7 8 8 9 9 10 10 13 + 14 + 11 11 = 1. Introduction = 12 12 13 13 == 1.1 What is LoRaWAN Soil Moisture & EC Sensor == ... ... @@ -54,6 +54,7 @@ 54 54 * IP66 Waterproof Enclosure 55 55 * 4000mAh or 8500mAh Battery for long term use 56 56 61 + 57 57 == 1.3 Specification == 58 58 59 59 Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height. ... ... @@ -85,7 +85,7 @@ 85 85 ))) 86 86 87 87 ((( 88 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3. UsingtheATCommands"]].93 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]]. 89 89 ))) 90 90 91 91 ... ... @@ -146,16 +146,17 @@ 146 146 Uplink payload includes in total 11 bytes. 147 147 148 148 149 -|((( 154 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %) 155 +|=((( 150 150 **Size** 151 151 152 152 **(bytes)** 153 -)))|**2**|**2**|**2**|**2**|**2**|**1** 154 -|**Value**|[[BAT>> path:#bat]]|(((159 +)))|=(% style="width: 46px;" %)**2**|=(% style="width: 160px;" %)**2**|=(% style="width: 104px;" %)**2**|=(% style="width: 126px;" %)**2**|=(% style="width: 159px;" %)**2**|=(% style="width: 114px;" %)**1** 160 +|**Value**|(% style="width:46px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:160px" %)((( 155 155 Temperature 156 156 157 157 (Reserve, Ignore now) 158 -)))|[[Soil Moisture>> path:#soil_moisture]]|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]]|(((164 +)))|(% style="width:104px" %)[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|(% style="width:126px" %)[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|(% style="width:159px" %)[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(% style="width:114px" %)((( 159 159 MOD & Digital Interrupt 160 160 161 161 (Optional) ... ... @@ -169,16 +169,17 @@ 169 169 170 170 This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation). 171 171 172 -|((( 178 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %) 179 +|=((( 173 173 **Size** 174 174 175 175 **(bytes)** 176 -)))|**2**|**2**|**2**|**2**|**2**|**1** 177 -|**Value**|[[BAT>> path:#bat]]|(((183 +)))|=**2**|=**2**|=**2**|=**2**|=**2**|=**1** 184 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|((( 178 178 Temperature 179 179 180 180 (Reserve, Ignore now) 181 -)))|[[Soil Moisture>> path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((188 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|((( 182 182 MOD & Digital Interrupt 183 183 184 184 (Optional) ... ... @@ -252,7 +252,7 @@ 252 252 mod=(bytes[10]>>7)&0x01=1. 253 253 254 254 255 -Downlink Command: 262 +**Downlink Command:** 256 256 257 257 If payload = 0x0A00, workmode=0 258 258 ... ... @@ -272,14 +272,13 @@ 272 272 LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]] 273 273 274 274 282 + 275 275 == 2.4 Uplink Interval == 276 276 277 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: 285 +The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]] 278 278 279 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]] 280 280 281 281 282 - 283 283 == 2.5 Downlink Payload == 284 284 285 285 By default, LSE50 prints the downlink payload to console port. ... ... @@ -626,6 +626,7 @@ 626 626 * Blink once when device transmit a packet. 627 627 628 628 635 + 629 629 == 2.9 Installation in Soil == 630 630 631 631 **Measurement the soil surface** ... ... @@ -634,31 +634,52 @@ 634 634 [[image:1654506634463-199.png]] 635 635 636 636 ((( 644 +((( 637 637 Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting. 638 638 ))) 647 +))) 639 639 640 640 641 - 642 642 [[image:1654506665940-119.png]] 643 643 652 +((( 644 644 Dig a hole with diameter > 20CM. 654 +))) 645 645 656 +((( 646 646 Horizontal insert the probe to the soil and fill the hole for long term measurement. 658 +))) 647 647 648 648 649 649 == 2.10 Firmware Change Log == 650 650 663 +((( 651 651 **Firmware download link:** 665 +))) 652 652 667 +((( 653 653 [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Firmware/]] 669 +))) 654 654 671 +((( 672 + 673 +))) 655 655 675 +((( 656 656 **Firmware Upgrade Method: **[[Firmware Upgrade Instruction>>doc:Main.Firmware Upgrade Instruction for STM32 base products.WebHome]] 677 +))) 657 657 679 +((( 680 + 681 +))) 658 658 683 +((( 659 659 **V1.0.** 685 +))) 660 660 687 +((( 661 661 Release 689 +))) 662 662 663 663 664 664 == 2.11 Battery Analysis == ... ... @@ -665,15 +665,19 @@ 665 665 666 666 === 2.11.1 Battery Type === 667 667 696 +((( 668 668 The LSE01 battery is a combination of a 4000mAh Li/SOCI2 Battery and a Super Capacitor. The battery is non-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 698 +))) 669 669 670 - 700 +((( 671 671 The battery is designed to last for more than 5 years for the LSN50. 702 +))) 672 672 673 - 674 674 ((( 705 +((( 675 675 The battery-related documents are as below: 676 676 ))) 708 +))) 677 677 678 678 * ((( 679 679 [[Battery Dimension>>url:http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/&file=LSN50-Battery-Dimension.pdf]], ... ... @@ -720,13 +720,13 @@ 720 720 721 721 LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below. 722 722 723 -[[image:1654501986557-872.png]] 755 +[[image:1654501986557-872.png||height="391" width="800"]] 724 724 725 725 726 726 Or if you have below board, use below connection: 727 727 728 728 729 -[[image:1654502005655-729.png]] 761 +[[image:1654502005655-729.png||height="503" width="801"]] 730 730 731 731 732 732 ... ... @@ -733,7 +733,7 @@ 733 733 In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below: 734 734 735 735 736 - [[image:1654502050864-459.png]] 768 + [[image:1654502050864-459.png||height="564" width="806"]] 737 737 738 738 739 739 Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]] ... ... @@ -848,20 +848,38 @@ 848 848 849 849 == 4.1 How to change the LoRa Frequency Bands/Region? == 850 850 851 -You can follow the instructions for [[how to upgrade image>>path:#3ygebqi]]. 883 +((( 884 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]]. 852 852 When downloading the images, choose the required image file for download. 886 +))) 853 853 888 +((( 889 + 890 +))) 854 854 892 +((( 855 855 How to set up LSE01 to work in 8 channel mode By default, the frequency bands US915, AU915, CN470 work in 72 frequencies. Many gateways are 8 channel gateways, and in this case, the OTAA join time and uplink schedule is long and unpredictable while the end node is hopping in 72 frequencies. 894 +))) 856 856 896 +((( 897 + 898 +))) 857 857 900 +((( 858 858 You can configure the end node to work in 8 channel mode by using the AT+CHE command. The 500kHz channels are always included for OTAA. 902 +))) 859 859 904 +((( 905 + 906 +))) 860 860 908 +((( 861 861 For example, in **US915** band, the frequency table is as below. By default, the end node will use all channels (0~~71) for OTAA Join process. After the OTAA Join, the end node will use these all channels (0~~71) to send uplink packets. 910 +))) 862 862 863 863 [[image:image-20220606154726-3.png]] 864 864 914 + 865 865 When you use the TTN network, the US915 frequency bands use are: 866 866 867 867 * 903.9 - SF7BW125 to SF10BW125 ... ... @@ -904,7 +904,9 @@ 904 904 905 905 == 5.2 AT Command input doesn’t work == 906 906 957 +((( 907 907 In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 959 +))) 908 908 909 909 910 910 == 5.3 Device rejoin in at the second uplink packet == ... ... @@ -916,7 +916,9 @@ 916 916 917 917 (% style="color:#4f81bd" %)**Cause for this issue:** 918 918 971 +((( 919 919 The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin. 973 +))) 920 920 921 921 922 922 (% style="color:#4f81bd" %)**Solution: ** ... ... @@ -923,7 +923,7 @@ 923 923 924 924 All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below: 925 925 926 -[[image:1654500929571-736.png]] 980 +[[image:1654500929571-736.png||height="458" width="832"]] 927 927 928 928 929 929 = 6. Order Info = ... ... @@ -948,6 +948,11 @@ 948 948 * (% style="color:red" %)**4**(%%): 4000mAh battery 949 949 * (% style="color:red" %)**8**(%%): 8500mAh battery 950 950 1005 +(% class="wikigeneratedid" %) 1006 +((( 1007 + 1008 +))) 1009 + 951 951 = 7. Packing Info = 952 952 953 953 ((( ... ... @@ -977,6 +977,9 @@ 977 977 ))) 978 978 * ((( 979 979 Weight / pcs : g 1039 + 1040 + 1041 + 980 980 ))) 981 981 982 982 = 8. Support =