... ... @@ -58,8 +58,6 @@
58 58  * IP66 Waterproof Enclosure
59 59  * 4000mAh or 8500mAh Battery for long term use
60 60  
61 -
62 -
63 63  == 1.3 Specification ==
64 64  
65 65  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -949,9 +949,7 @@
949 949  
950 950  (% style="color:#4f81bd" %)**Cause for this issue:**
951 951  
952 -(((
953 953  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
954 -)))
955 955  
956 956  
957 957  (% style="color:#4f81bd" %)**Solution: **
... ... @@ -958,7 +958,7 @@
958 958  
959 959  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
960 960  
961 -[[image:1654500929571-736.png||height="458" width="832"]]
957 +[[image:1654500929571-736.png]]
962 962  
963 963  
964 964  = 6. ​Order Info =