934 934  == 5.2 AT Command input doesn’t work ==
935 935  
936 +(((
936 936  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
938 +)))
937 937  
938 938  
939 939  == 5.3 Device rejoin in at the second uplink packet ==
... ... @@ -945,7 +945,9 @@
945 945  
946 946  (% style="color:#4f81bd" %)**Cause for this issue:**
947 947  
950 +(((
948 948  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
952 +)))
949 949  
950 950  
951 951  (% style="color:#4f81bd" %)**Solution: **