... ... @@ -58,6 +58,8 @@
58 58  * IP66 Waterproof Enclosure
59 59  * 4000mAh or 8500mAh Battery for long term use
60 60  
61 +
62 +
61 61  == 1.3 Specification ==
62 62  
63 63  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -89,7 +89,7 @@
89 89  )))
90 90  
91 91  (((
92 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.UsingtheATCommands"]].
94 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]].
93 93  )))
94 94  
95 95  
... ... @@ -749,13 +749,13 @@
749 749  
750 750  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
751 751  
752 -[[image:1654501986557-872.png]]
754 +[[image:1654501986557-872.png||height="391" width="800"]]
753 753  
754 754  
755 755  Or if you have below board, use below connection:
756 756  
757 757  
758 -[[image:1654502005655-729.png]]
760 +[[image:1654502005655-729.png||height="503" width="801"]]
759 759  
760 760  
761 761  
... ... @@ -762,7 +762,7 @@
762 762  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
763 763  
764 764  
765 - [[image:1654502050864-459.png]]
767 + [[image:1654502050864-459.png||height="564" width="806"]]
766 766  
767 767  
768 768  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
... ... @@ -933,7 +933,9 @@
933 933  
934 934  == 5.2 AT Command input doesn’t work ==
935 935  
938 +(((
936 936  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
940 +)))
937 937  
938 938  
939 939  == 5.3 Device rejoin in at the second uplink packet ==
... ... @@ -945,7 +945,9 @@
945 945  
946 946  (% style="color:#4f81bd" %)**Cause for this issue:**
947 947  
952 +(((
948 948  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
954 +)))
949 949  
950 950  
951 951  (% style="color:#4f81bd" %)**Solution: **
... ... @@ -952,7 +952,7 @@
952 952  
953 953  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
954 954  
955 -[[image:1654500929571-736.png]]
961 +[[image:1654500929571-736.png||height="458" width="832"]]
956 956  
957 957  
958 958  = 6. ​Order Info =
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved