<
From version < 31.24 >
edited by Xiaoling
on 2022/06/07 10:16
To version < 31.34 >
edited by Xiaoling
on 2022/06/07 10:33
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -90,7 +90,7 @@
90 90  )))
91 91  
92 92  (((
93 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.UsingtheATCommands"]].
93 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]].
94 94  )))
95 95  
96 96  
... ... @@ -279,14 +279,13 @@
279 279  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
280 280  
281 281  
282 +
282 282  == 2.4 Uplink Interval ==
283 283  
284 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
285 +The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
285 285  
286 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
287 287  
288 288  
289 -
290 290  == 2.5 Downlink Payload ==
291 291  
292 292  By default, LSE50 prints the downlink payload to console port.
... ... @@ -753,13 +753,13 @@
753 753  
754 754  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
755 755  
756 -[[image:1654501986557-872.png]]
755 +[[image:1654501986557-872.png||height="391" width="800"]]
757 757  
758 758  
759 759  Or if you have below board, use below connection:
760 760  
761 761  
762 -[[image:1654502005655-729.png]]
761 +[[image:1654502005655-729.png||height="503" width="801"]]
763 763  
764 764  
765 765  
... ... @@ -766,7 +766,7 @@
766 766  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
767 767  
768 768  
769 - [[image:1654502050864-459.png]]
768 + [[image:1654502050864-459.png||height="564" width="806"]]
770 770  
771 771  
772 772  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
... ... @@ -937,7 +937,9 @@
937 937  
938 938  == 5.2 AT Command input doesn’t work ==
939 939  
939 +(((
940 940  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
941 +)))
941 941  
942 942  
943 943  == 5.3 Device rejoin in at the second uplink packet ==
... ... @@ -949,7 +949,9 @@
949 949  
950 950  (% style="color:#4f81bd" %)**Cause for this issue:**
951 951  
953 +(((
952 952  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
955 +)))
953 953  
954 954  
955 955  (% style="color:#4f81bd" %)**Solution: **
... ... @@ -956,7 +956,7 @@
956 956  
957 957  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
958 958  
959 -[[image:1654500929571-736.png]]
962 +[[image:1654500929571-736.png||height="458" width="832"]]
960 960  
961 961  
962 962  = 6. ​Order Info =
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0