... ... @@ -59,7 +59,6 @@
59 59  * 4000mAh or 8500mAh Battery for long term use
60 60  
61 61  
62 -
63 63  == 1.3 Specification ==
64 64  
65 65  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -91,7 +91,7 @@
91 91  )))
92 92  
93 93  (((
94 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.UsingtheATCommands"]].
93 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]].
95 95  )))
96 96  
97 97  
... ... @@ -182,11 +182,11 @@
182 182  
183 183  **(bytes)**
184 184  )))|=**2**|=**2**|=**2**|=**2**|=**2**|=**1**
185 -|**Value**|[[BAT>>path:#bat]]|(((
184 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
186 186  Temperature
187 187  
188 188  (Reserve, Ignore now)
189 -)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((
188 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
190 190  MOD & Digital Interrupt
191 191  
192 192  (Optional)
... ... @@ -260,7 +260,7 @@
260 260  mod=(bytes[10]>>7)&0x01=1.
261 261  
262 262  
263 -Downlink Command:
262 +**Downlink Command:**
264 264  
265 265  If payload = 0x0A00, workmode=0
266 266  
... ... @@ -280,14 +280,13 @@
280 280  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
281 281  
282 282  
282 +
283 283  == 2.4 Uplink Interval ==
284 284  
285 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
285 +The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
286 286  
287 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
288 288  
289 289  
290 -
291 291  == 2.5 Downlink Payload ==
292 292  
293 293  By default, LSE50 prints the downlink payload to console port.
... ... @@ -633,6 +633,8 @@
633 633  * Solid ON for 5 seconds once device successful Join the network.
634 634  * Blink once when device transmit a packet.
635 635  
634 +
635 +
636 636  == 2.9 Installation in Soil ==
637 637  
638 638  **Measurement the soil surface**
... ... @@ -752,13 +752,13 @@
752 752  
753 753  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
754 754  
755 -[[image:1654501986557-872.png]]
755 +[[image:1654501986557-872.png||height="391" width="800"]]
756 756  
757 757  
758 758  Or if you have below board, use below connection:
759 759  
760 760  
761 -[[image:1654502005655-729.png]]
761 +[[image:1654502005655-729.png||height="503" width="801"]]
762 762  
763 763  
764 764  
... ... @@ -765,7 +765,7 @@
765 765  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
766 766  
767 767  
768 - [[image:1654502050864-459.png]]
768 + [[image:1654502050864-459.png||height="564" width="806"]]
769 769  
770 770  
771 771  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
... ... @@ -880,20 +880,38 @@
880 880  
881 881  == 4.1 ​How to change the LoRa Frequency Bands/Region? ==
882 882  
883 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.10FirmwareChangeLog"]].
883 +(((
884 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
884 884  When downloading the images, choose the required image file for download. ​
886 +)))
885 885  
888 +(((
889 +
890 +)))
886 886  
892 +(((
887 887  How to set up LSE01 to work in 8 channel mode By default, the frequency bands US915, AU915, CN470 work in 72 frequencies. Many gateways are 8 channel gateways, and in this case, the OTAA join time and uplink schedule is long and unpredictable while the end node is hopping in 72 frequencies.
894 +)))
888 888  
896 +(((
897 +
898 +)))
889 889  
900 +(((
890 890  You can configure the end node to work in 8 channel mode by using the AT+CHE command. The 500kHz channels are always included for OTAA.
902 +)))
891 891  
904 +(((
905 +
906 +)))
892 892  
908 +(((
893 893  For example, in **US915** band, the frequency table is as below. By default, the end node will use all channels (0~~71) for OTAA Join process. After the OTAA Join, the end node will use these all channels (0~~71) to send uplink packets.
910 +)))
894 894  
895 895  [[image:image-20220606154726-3.png]]
896 896  
914 +
897 897  When you use the TTN network, the US915 frequency bands use are:
898 898  
899 899  * 903.9 - SF7BW125 to SF10BW125
... ... @@ -906,7 +906,9 @@
906 906  * 905.3 - SF7BW125 to SF10BW125
907 907  * 904.6 - SF8BW500
908 908  
927 +(((
909 909  Because the end node is now hopping in 72 frequency, it makes it difficult for the devices to Join the TTN network and uplink data. To solve this issue, you can access the device via the AT commands and run:
929 +)))
910 910  
911 911  (% class="box infomessage" %)
912 912  (((
... ... @@ -918,10 +918,17 @@
918 918  **ATZ**
919 919  )))
920 920  
941 +(((
921 921  to set the end node to work in 8 channel mode. The device will work in Channel 8-15 & 64-71 for OTAA, and channel 8-15 for Uplink.
943 +)))
922 922  
945 +(((
946 +
947 +)))
923 923  
949 +(((
924 924  The **AU915** band is similar. Below are the AU915 Uplink Channels.
951 +)))
925 925  
926 926  [[image:image-20220606154825-4.png]]
927 927  
... ... @@ -936,7 +936,9 @@
936 936  
937 937  == 5.2 AT Command input doesn’t work ==
938 938  
966 +(((
939 939  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
968 +)))
940 940  
941 941  
942 942  == 5.3 Device rejoin in at the second uplink packet ==
... ... @@ -948,7 +948,9 @@
948 948  
949 949  (% style="color:#4f81bd" %)**Cause for this issue:**
950 950  
980 +(((
951 951  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
982 +)))
952 952  
953 953  
954 954  (% style="color:#4f81bd" %)**Solution: **
... ... @@ -955,7 +955,7 @@
955 955  
956 956  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
957 957  
958 -[[image:1654500929571-736.png]]
989 +[[image:1654500929571-736.png||height="458" width="832"]]
959 959  
960 960  
961 961  = 6. ​Order Info =
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved