<
From version < 31.17 >
edited by Xiaoling
on 2022/06/07 09:31
To version < 31.32 >
edited by Xiaoling
on 2022/06/07 10:29
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -158,11 +158,11 @@
158 158  
159 159  **(bytes)**
160 160  )))|=(% style="width: 46px;" %)**2**|=(% style="width: 160px;" %)**2**|=(% style="width: 104px;" %)**2**|=(% style="width: 126px;" %)**2**|=(% style="width: 159px;" %)**2**|=(% style="width: 114px;" %)**1**
161 -|**Value**|(% style="width:46px" %)[[BAT>>path:#bat]]|(% style="width:160px" %)(((
161 +|**Value**|(% style="width:46px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:160px" %)(((
162 162  Temperature
163 163  
164 164  (Reserve, Ignore now)
165 -)))|(% style="width:104px" %)[[Soil Moisture>>path:#soil_moisture]]|(% style="width:126px" %)[[Soil Temperature>>path:#soil_tem]]|(% style="width:159px" %)[[Soil Conductivity (EC)>>path:#EC]]|(% style="width:114px" %)(((
165 +)))|(% style="width:104px" %)[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|(% style="width:126px" %)[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|(% style="width:159px" %)[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(% style="width:114px" %)(((
166 166  MOD & Digital Interrupt
167 167  
168 168  (Optional)
... ... @@ -182,11 +182,11 @@
182 182  
183 183  **(bytes)**
184 184  )))|=**2**|=**2**|=**2**|=**2**|=**2**|=**1**
185 -|**Value**|[[BAT>>path:#bat]]|(((
185 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
186 186  Temperature
187 187  
188 188  (Reserve, Ignore now)
189 -)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((
189 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
190 190  MOD & Digital Interrupt
191 191  
192 192  (Optional)
... ... @@ -260,7 +260,7 @@
260 260  mod=(bytes[10]>>7)&0x01=1.
261 261  
262 262  
263 -Downlink Command:
263 +**Downlink Command:**
264 264  
265 265  If payload = 0x0A00, workmode=0
266 266  
... ... @@ -280,14 +280,13 @@
280 280  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
281 281  
282 282  
283 +
283 283  == 2.4 Uplink Interval ==
284 284  
285 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
286 +The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
286 286  
287 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
288 288  
289 289  
290 -
291 291  == 2.5 Downlink Payload ==
292 292  
293 293  By default, LSE50 prints the downlink payload to console port.
... ... @@ -752,13 +752,13 @@
752 752  
753 753  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
754 754  
755 -[[image:1654501986557-872.png]]
754 +[[image:1654501986557-872.png||height="391" width="800"]]
756 756  
757 757  
758 758  Or if you have below board, use below connection:
759 759  
760 760  
761 -[[image:1654502005655-729.png]]
760 +[[image:1654502005655-729.png||height="503" width="801"]]
762 762  
763 763  
764 764  
... ... @@ -765,7 +765,7 @@
765 765  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
766 766  
767 767  
768 - [[image:1654502050864-459.png]]
767 + [[image:1654502050864-459.png||height="564" width="806"]]
769 769  
770 770  
771 771  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
... ... @@ -880,7 +880,7 @@
880 880  
881 881  == 4.1 ​How to change the LoRa Frequency Bands/Region? ==
882 882  
883 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.10FirmwareChangeLog"]].
882 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
884 884  When downloading the images, choose the required image file for download. ​
885 885  
886 886  
... ... @@ -936,7 +936,9 @@
936 936  
937 937  == 5.2 AT Command input doesn’t work ==
938 938  
938 +(((
939 939  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
940 +)))
940 940  
941 941  
942 942  == 5.3 Device rejoin in at the second uplink packet ==
... ... @@ -948,7 +948,9 @@
948 948  
949 949  (% style="color:#4f81bd" %)**Cause for this issue:**
950 950  
952 +(((
951 951  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
954 +)))
952 952  
953 953  
954 954  (% style="color:#4f81bd" %)**Solution: **
... ... @@ -955,7 +955,7 @@
955 955  
956 956  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
957 957  
958 -[[image:1654500929571-736.png]]
961 +[[image:1654500929571-736.png||height="458" width="832"]]
959 959  
960 960  
961 961  = 6. ​Order Info =
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0