From version < 31.15 >
edited by Xiaoling
on 2022/06/07 09:25
To version < 31.37 >
edited by Xiaoling
on 2022/06/07 10:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,11 +3,15 @@
3 3  
4 4  
5 5  
6 +**Contents:**
6 6  
8 +{{toc/}}
7 7  
8 8  
9 9  
10 10  
13 +
14 +
11 11  = 1. Introduction =
12 12  
13 13  == 1.1 ​What is LoRaWAN Soil Moisture & EC Sensor ==
... ... @@ -55,7 +55,6 @@
55 55  * 4000mAh or 8500mAh Battery for long term use
56 56  
57 57  
58 -
59 59  == 1.3 Specification ==
60 60  
61 61  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -87,7 +87,7 @@
87 87  )))
88 88  
89 89  (((
90 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.UsingtheATCommands"]].
93 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]].
91 91  )))
92 92  
93 93  
... ... @@ -148,16 +148,17 @@
148 148  Uplink payload includes in total 11 bytes.
149 149  
150 150  
151 -|(((
154 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %)
155 +|=(((
152 152  **Size**
153 153  
154 154  **(bytes)**
155 -)))|**2**|**2**|**2**|**2**|**2**|**1**
156 -|**Value**|[[BAT>>path:#bat]]|(((
159 +)))|=(% style="width: 46px;" %)**2**|=(% style="width: 160px;" %)**2**|=(% style="width: 104px;" %)**2**|=(% style="width: 126px;" %)**2**|=(% style="width: 159px;" %)**2**|=(% style="width: 114px;" %)**1**
160 +|**Value**|(% style="width:46px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:160px" %)(((
157 157  Temperature
158 158  
159 159  (Reserve, Ignore now)
160 -)))|[[Soil Moisture>>path:#soil_moisture]]|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]]|(((
164 +)))|(% style="width:104px" %)[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|(% style="width:126px" %)[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|(% style="width:159px" %)[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(% style="width:114px" %)(((
161 161  MOD & Digital Interrupt
162 162  
163 163  (Optional)
... ... @@ -171,16 +171,17 @@
171 171  
172 172  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
173 173  
174 -|(((
178 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %)
179 +|=(((
175 175  **Size**
176 176  
177 177  **(bytes)**
178 -)))|**2**|**2**|**2**|**2**|**2**|**1**
179 -|**Value**|[[BAT>>path:#bat]]|(((
183 +)))|=**2**|=**2**|=**2**|=**2**|=**2**|=**1**
184 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
180 180  Temperature
181 181  
182 182  (Reserve, Ignore now)
183 -)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((
188 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
184 184  MOD & Digital Interrupt
185 185  
186 186  (Optional)
... ... @@ -254,7 +254,7 @@
254 254  mod=(bytes[10]>>7)&0x01=1.
255 255  
256 256  
257 -Downlink Command:
262 +**Downlink Command:**
258 258  
259 259  If payload = 0x0A00, workmode=0
260 260  
... ... @@ -274,14 +274,13 @@
274 274  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
275 275  
276 276  
282 +
277 277  == 2.4 Uplink Interval ==
278 278  
279 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
285 +The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
280 280  
281 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
282 282  
283 283  
284 -
285 285  == 2.5 Downlink Payload ==
286 286  
287 287  By default, LSE50 prints the downlink payload to console port.
... ... @@ -627,6 +627,8 @@
627 627  * Solid ON for 5 seconds once device successful Join the network.
628 628  * Blink once when device transmit a packet.
629 629  
634 +
635 +
630 630  == 2.9 Installation in Soil ==
631 631  
632 632  **Measurement the soil surface**
... ... @@ -746,13 +746,13 @@
746 746  
747 747  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
748 748  
749 -[[image:1654501986557-872.png]]
755 +[[image:1654501986557-872.png||height="391" width="800"]]
750 750  
751 751  
752 752  Or if you have below board, use below connection:
753 753  
754 754  
755 -[[image:1654502005655-729.png]]
761 +[[image:1654502005655-729.png||height="503" width="801"]]
756 756  
757 757  
758 758  
... ... @@ -759,7 +759,7 @@
759 759  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
760 760  
761 761  
762 - [[image:1654502050864-459.png]]
768 + [[image:1654502050864-459.png||height="564" width="806"]]
763 763  
764 764  
765 765  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
... ... @@ -874,20 +874,38 @@
874 874  
875 875  == 4.1 ​How to change the LoRa Frequency Bands/Region? ==
876 876  
877 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.10FirmwareChangeLog"]].
883 +(((
884 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
878 878  When downloading the images, choose the required image file for download. ​
886 +)))
879 879  
888 +(((
889 +
890 +)))
880 880  
892 +(((
881 881  How to set up LSE01 to work in 8 channel mode By default, the frequency bands US915, AU915, CN470 work in 72 frequencies. Many gateways are 8 channel gateways, and in this case, the OTAA join time and uplink schedule is long and unpredictable while the end node is hopping in 72 frequencies.
894 +)))
882 882  
896 +(((
897 +
898 +)))
883 883  
900 +(((
884 884  You can configure the end node to work in 8 channel mode by using the AT+CHE command. The 500kHz channels are always included for OTAA.
902 +)))
885 885  
904 +(((
905 +
906 +)))
886 886  
908 +(((
887 887  For example, in **US915** band, the frequency table is as below. By default, the end node will use all channels (0~~71) for OTAA Join process. After the OTAA Join, the end node will use these all channels (0~~71) to send uplink packets.
910 +)))
888 888  
889 889  [[image:image-20220606154726-3.png]]
890 890  
914 +
891 891  When you use the TTN network, the US915 frequency bands use are:
892 892  
893 893  * 903.9 - SF7BW125 to SF10BW125
... ... @@ -930,7 +930,9 @@
930 930  
931 931  == 5.2 AT Command input doesn’t work ==
932 932  
957 +(((
933 933  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
959 +)))
934 934  
935 935  
936 936  == 5.3 Device rejoin in at the second uplink packet ==
... ... @@ -942,7 +942,9 @@
942 942  
943 943  (% style="color:#4f81bd" %)**Cause for this issue:**
944 944  
971 +(((
945 945  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
973 +)))
946 946  
947 947  
948 948  (% style="color:#4f81bd" %)**Solution: **
... ... @@ -949,7 +949,7 @@
949 949  
950 950  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
951 951  
952 -[[image:1654500929571-736.png]]
980 +[[image:1654500929571-736.png||height="458" width="832"]]
953 953  
954 954  
955 955  = 6. ​Order Info =
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved