<
From version < 31.14 >
edited by Xiaoling
on 2022/06/07 09:25
To version < 31.37 >
edited by Xiaoling
on 2022/06/07 10:34
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -3,11 +3,15 @@
3 3  
4 4  
5 5  
6 +**Contents:**
6 6  
8 +{{toc/}}
7 7  
8 8  
9 9  
10 10  
13 +
14 +
11 11  = 1. Introduction =
12 12  
13 13  == 1.1 ​What is LoRaWAN Soil Moisture & EC Sensor ==
... ... @@ -54,6 +54,7 @@
54 54  * IP66 Waterproof Enclosure
55 55  * 4000mAh or 8500mAh Battery for long term use
56 56  
61 +
57 57  == 1.3 Specification ==
58 58  
59 59  Measure Volume: Base on the centra pin of the probe, a cylinder with 7cm diameter and 10cm height.
... ... @@ -85,7 +85,7 @@
85 85  )))
86 86  
87 87  (((
88 -In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.UsingtheATCommands"]].
93 +In case you can’t set the OTAA keys in the LoRaWAN OTAA server, and you have to use the keys from the server, you can [[use AT Commands >>||anchor="H3.200BUsingtheATCommands"]].
89 89  )))
90 90  
91 91  
... ... @@ -146,16 +146,17 @@
146 146  Uplink payload includes in total 11 bytes.
147 147  
148 148  
149 -|(((
154 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %)
155 +|=(((
150 150  **Size**
151 151  
152 152  **(bytes)**
153 -)))|**2**|**2**|**2**|**2**|**2**|**1**
154 -|**Value**|[[BAT>>path:#bat]]|(((
159 +)))|=(% style="width: 46px;" %)**2**|=(% style="width: 160px;" %)**2**|=(% style="width: 104px;" %)**2**|=(% style="width: 126px;" %)**2**|=(% style="width: 159px;" %)**2**|=(% style="width: 114px;" %)**1**
160 +|**Value**|(% style="width:46px" %)[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(% style="width:160px" %)(((
155 155  Temperature
156 156  
157 157  (Reserve, Ignore now)
158 -)))|[[Soil Moisture>>path:#soil_moisture]]|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]]|(((
164 +)))|(% style="width:104px" %)[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|(% style="width:126px" %)[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|(% style="width:159px" %)[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]]|(% style="width:114px" %)(((
159 159  MOD & Digital Interrupt
160 160  
161 161  (Optional)
... ... @@ -169,16 +169,17 @@
169 169  
170 170  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
171 171  
172 -|(((
178 +(% border="1" cellspacing="10" style="background-color:#f7faff; width:510px" %)
179 +|=(((
173 173  **Size**
174 174  
175 175  **(bytes)**
176 -)))|**2**|**2**|**2**|**2**|**2**|**1**
177 -|**Value**|[[BAT>>path:#bat]]|(((
183 +)))|=**2**|=**2**|=**2**|=**2**|=**2**|=**1**
184 +|**Value**|[[BAT>>||anchor="H2.3.3BatteryInfo"]]|(((
178 178  Temperature
179 179  
180 180  (Reserve, Ignore now)
181 -)))|[[Soil Moisture>>path:#soil_moisture]](raw)|[[Soil Temperature>>path:#soil_tem]]|[[Soil Conductivity (EC)>>path:#EC]](raw)|(((
188 +)))|[[Soil Moisture>>||anchor="H2.3.4SoilMoisture"]]|[[Soil Temperature>>||anchor="H2.3.5SoilTemperature"]]|[[Soil Conductivity (EC)>>||anchor="H2.3.6SoilConductivity28EC29"]](raw)|(((
182 182  MOD & Digital Interrupt
183 183  
184 184  (Optional)
... ... @@ -252,7 +252,7 @@
252 252  mod=(bytes[10]>>7)&0x01=1.
253 253  
254 254  
255 -Downlink Command:
262 +**Downlink Command:**
256 256  
257 257  If payload = 0x0A00, workmode=0
258 258  
... ... @@ -272,14 +272,13 @@
272 272  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
273 273  
274 274  
282 +
275 275  == 2.4 Uplink Interval ==
276 276  
277 -The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
285 +The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link: [[Change Uplink Interval>>doc:Main.End Device AT Commands and Downlink Command.WebHome||anchor="H4.1ChangeUplinkInterval"]]
278 278  
279 -[[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
280 280  
281 281  
282 -
283 283  == 2.5 Downlink Payload ==
284 284  
285 285  By default, LSE50 prints the downlink payload to console port.
... ... @@ -625,6 +625,8 @@
625 625  * Solid ON for 5 seconds once device successful Join the network.
626 626  * Blink once when device transmit a packet.
627 627  
634 +
635 +
628 628  == 2.9 Installation in Soil ==
629 629  
630 630  **Measurement the soil surface**
... ... @@ -744,13 +744,13 @@
744 744  
745 745  LSE01 supports AT Command set in the stock firmware. You can use a USB to TTL adapter to connect to LSE01 for using AT command, as below.
746 746  
747 -[[image:1654501986557-872.png]]
755 +[[image:1654501986557-872.png||height="391" width="800"]]
748 748  
749 749  
750 750  Or if you have below board, use below connection:
751 751  
752 752  
753 -[[image:1654502005655-729.png]]
761 +[[image:1654502005655-729.png||height="503" width="801"]]
754 754  
755 755  
756 756  
... ... @@ -757,7 +757,7 @@
757 757  In the PC, you need to set the serial baud rate to (% style="color:green" %)**9600**(%%) to access the serial console for LSE01. LSE01 will output system info once power on as below:
758 758  
759 759  
760 - [[image:1654502050864-459.png]]
768 + [[image:1654502050864-459.png||height="564" width="806"]]
761 761  
762 762  
763 763  Below are the available commands, a more detailed AT Command manual can be found at [[AT Command Manual>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/]]
... ... @@ -872,20 +872,38 @@
872 872  
873 873  == 4.1 ​How to change the LoRa Frequency Bands/Region? ==
874 874  
875 -You can follow the instructions for [[how to upgrade image>>||anchor="H2.10FirmwareChangeLog"]].
883 +(((
884 +You can follow the instructions for [[how to upgrade image>>||anchor="H2.10200BFirmwareChangeLog"]].
876 876  When downloading the images, choose the required image file for download. ​
886 +)))
877 877  
888 +(((
889 +
890 +)))
878 878  
892 +(((
879 879  How to set up LSE01 to work in 8 channel mode By default, the frequency bands US915, AU915, CN470 work in 72 frequencies. Many gateways are 8 channel gateways, and in this case, the OTAA join time and uplink schedule is long and unpredictable while the end node is hopping in 72 frequencies.
894 +)))
880 880  
896 +(((
897 +
898 +)))
881 881  
900 +(((
882 882  You can configure the end node to work in 8 channel mode by using the AT+CHE command. The 500kHz channels are always included for OTAA.
902 +)))
883 883  
904 +(((
905 +
906 +)))
884 884  
908 +(((
885 885  For example, in **US915** band, the frequency table is as below. By default, the end node will use all channels (0~~71) for OTAA Join process. After the OTAA Join, the end node will use these all channels (0~~71) to send uplink packets.
910 +)))
886 886  
887 887  [[image:image-20220606154726-3.png]]
888 888  
914 +
889 889  When you use the TTN network, the US915 frequency bands use are:
890 890  
891 891  * 903.9 - SF7BW125 to SF10BW125
... ... @@ -928,7 +928,9 @@
928 928  
929 929  == 5.2 AT Command input doesn’t work ==
930 930  
957 +(((
931 931  In the case if user can see the console output but can’t type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn’t send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
959 +)))
932 932  
933 933  
934 934  == 5.3 Device rejoin in at the second uplink packet ==
... ... @@ -940,7 +940,9 @@
940 940  
941 941  (% style="color:#4f81bd" %)**Cause for this issue:**
942 942  
971 +(((
943 943  The fuse on LSE01 is not large enough, some of the soil probe require large current up to 5v 800mA, in a short pulse. When this happen, it cause the device reboot so user see rejoin.
973 +)))
944 944  
945 945  
946 946  (% style="color:#4f81bd" %)**Solution: **
... ... @@ -947,7 +947,7 @@
947 947  
948 948  All new shipped LSE01 after 2020-May-30 will have this to fix. For the customer who see this issue, please bypass the fuse as below:
949 949  
950 -[[image:1654500929571-736.png]]
980 +[[image:1654500929571-736.png||height="458" width="832"]]
951 951  
952 952  
953 953  = 6. ​Order Info =
Copyright ©2010-2024 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0