From version < 20.2 >
edited by Xiaoling
on 2022/06/06 16:39
To version < 23.2 >
edited by Xiaoling
on 2022/06/06 16:53
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -66,11 +66,9 @@
66 66  
67 67  * Smart Agriculture
68 68  
69 -
70 70  (% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %)
71 71  ​
72 72  
73 -(% class="wikigeneratedid" %)
74 74  == 1.5 Firmware Change log ==
75 75  
76 76  
... ... @@ -138,10 +138,9 @@
138 138  
139 139  
140 140  
139 +== 2.3 Uplink Payload ==
141 141  
142 -1.
143 -11. ​Uplink Payload
144 -111. MOD=0(Default Mode)
141 +=== 2.3.1 MOD~=0(Default Mode) ===
145 145  
146 146  LSE01 will uplink payload via LoRaWAN with below payload format: 
147 147  
... ... @@ -164,13 +164,12 @@
164 164  (Optional)
165 165  )))
166 166  
167 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]]
164 +[[image:1654504881641-514.png]]
168 168  
169 169  
170 -1.
171 -11.
172 -111. MOD=1(Original value)
173 173  
168 +=== 2.3.2 MOD~=1(Original value) ===
169 +
174 174  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
175 175  
176 176  |(((
... ... @@ -188,12 +188,12 @@
188 188  (Optional)
189 189  )))
190 190  
191 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image008.png]]
187 +[[image:1654504907647-967.png]]
192 192  
193 -1.
194 -11.
195 -111. Battery Info
196 196  
190 +
191 +=== 2.3.3 Battery Info ===
192 +
197 197  Check the battery voltage for LSE01.
198 198  
199 199  Ex1: 0x0B45 = 2885mV
... ... @@ -202,21 +202,19 @@
202 202  
203 203  
204 204  
205 -1.
206 -11.
207 -111. Soil Moisture
201 +=== 2.3.4 Soil Moisture ===
208 208  
209 209  Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
210 210  
211 -For example, if the data you get from the register is 0x05 0xDC, the moisture content in the soil is
205 +For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
212 212  
213 -**05DC(H) = 1500(D) /100 = 15%.**
214 214  
208 +(% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
215 215  
216 -1.
217 -11.
218 -111. Soil Temperature
219 219  
211 +
212 +=== 2.3.5 Soil Temperature ===
213 +
220 220   Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
221 221  
222 222  **Example**:
... ... @@ -226,21 +226,31 @@
226 226  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
227 227  
228 228  
229 -1.
230 -11.
231 -111. Soil Conductivity (EC)
232 232  
233 -Obtain soluble salt concentration in soil or soluble ion concentration in liquid fertilizer or planting medium,. The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
224 +=== 2.3.6 Soil Conductivity (EC) ===
234 234  
226 +(((
227 +Obtain (% style="color:#4f81bd" %)**__soluble salt concentration__**(%%) in soil or (% style="color:#4f81bd" %)**__soluble ion concentration in liquid fertilizer__**(%%) or (% style="color:#4f81bd" %)**__planting medium__**(%%). The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
228 +)))
229 +
230 +(((
235 235  For example, if the data you get from the register is 0x00 0xC8, the soil conductivity is 00C8(H) = 200(D) = 200 uS/cm.
232 +)))
236 236  
237 -
234 +(((
238 238  Generally, the EC value of irrigation water is less than 800uS / cm.
236 +)))
239 239  
240 -1.
241 -11.
242 -111. MOD
238 +(((
239 +
240 +)))
243 243  
242 +(((
243 +
244 +)))
245 +
246 +=== 2.3.7 MOD ===
247 +
244 244  Firmware version at least v2.1 supports changing mode.
245 245  
246 246  For example, bytes[10]=90
... ... @@ -255,14 +255,13 @@
255 255  If** **payload =** **0x0A01, workmode=1
256 256  
257 257  
258 -1.
259 -11.
260 -111. ​Decode payload in The Things Network
261 261  
263 +=== 2.3.8 ​Decode payload in The Things Network ===
264 +
262 262  While using TTN network, you can add the payload format to decode the payload.
263 263  
264 264  
265 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image009.png]]
268 +[[image:1654505570700-128.png]]
266 266  
267 267  The payload decoder function for TTN is here:
268 268  
1654504881641-514.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +119.4 KB
Content
1654504907647-967.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +54.7 KB
Content
1654505570700-128.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +59.2 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0