<
From version < 20.2 >
edited by Xiaoling
on 2022/06/06 16:39
To version < 22.6 >
edited by Xiaoling
on 2022/06/06 16:48
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -66,11 +66,9 @@
66 66  
67 67  * Smart Agriculture
68 68  
69 -
70 70  (% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %)
71 71  ​
72 72  
73 -(% class="wikigeneratedid" %)
74 74  == 1.5 Firmware Change log ==
75 75  
76 76  
... ... @@ -138,10 +138,9 @@
138 138  
139 139  
140 140  
139 +== 2.3 Uplink Payload ==
141 141  
142 -1.
143 -11. ​Uplink Payload
144 -111. MOD=0(Default Mode)
141 +=== 2.3.1 MOD~=0(Default Mode) ===
145 145  
146 146  LSE01 will uplink payload via LoRaWAN with below payload format: 
147 147  
... ... @@ -164,13 +164,12 @@
164 164  (Optional)
165 165  )))
166 166  
167 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image007.png]]
164 +[[image:1654504881641-514.png]]
168 168  
169 169  
170 -1.
171 -11.
172 -111. MOD=1(Original value)
173 173  
168 +=== 2.3.2 MOD~=1(Original value) ===
169 +
174 174  This mode can get the original AD value of moisture and original conductivity (with temperature drift compensation).
175 175  
176 176  |(((
... ... @@ -188,12 +188,12 @@
188 188  (Optional)
189 189  )))
190 190  
191 -[[image:file:///C:/Users/93456/AppData/Local/Temp/msohtmlclip1/01/clip_image008.png]]
187 +[[image:1654504907647-967.png]]
192 192  
193 -1.
194 -11.
195 -111. Battery Info
196 196  
190 +
191 +=== 2.3.3 Battery Info ===
192 +
197 197  Check the battery voltage for LSE01.
198 198  
199 199  Ex1: 0x0B45 = 2885mV
... ... @@ -202,21 +202,19 @@
202 202  
203 203  
204 204  
205 -1.
206 -11.
207 -111. Soil Moisture
201 +=== 2.3.4 Soil Moisture ===
208 208  
209 209  Get the moisture content of the soil. The value range of the register is 0-10000(Decimal), divide this value by 100 to get the percentage of moisture in the soil.
210 210  
211 -For example, if the data you get from the register is 0x05 0xDC, the moisture content in the soil is
205 +For example, if the data you get from the register is __0x05 0xDC__, the moisture content in the soil is
212 212  
213 -**05DC(H) = 1500(D) /100 = 15%.**
214 214  
208 +(% style="color:#4f81bd" %)**05DC(H) = 1500(D) /100 = 15%.**
215 215  
216 -1.
217 -11.
218 -111. Soil Temperature
219 219  
211 +
212 +=== 2.3.5 Soil Temperature ===
213 +
220 220   Get the temperature in the soil. The value range of the register is -4000 - +800(Decimal), divide this value by 100 to get the temperature in the soil. For example, if the data you get from the register is 0x09 0xEC, the temperature content in the soil is
221 221  
222 222  **Example**:
... ... @@ -226,10 +226,9 @@
226 226  If payload is FF7EH: ((FF7E & 0x8000)>>15 ===1),temp = (FF7E(H)-FFFF(H))/100 = -1.29 °C
227 227  
228 228  
229 -1.
230 -11.
231 -111. Soil Conductivity (EC)
232 232  
224 +=== 2.3.6 Soil Conductivity (EC) ===
225 +
233 233  Obtain soluble salt concentration in soil or soluble ion concentration in liquid fertilizer or planting medium,. The value range of the register is 0 - 20000(Decimal)( Can be greater than 20000).
234 234  
235 235  For example, if the data you get from the register is 0x00 0xC8, the soil conductivity is 00C8(H) = 200(D) = 200 uS/cm.
... ... @@ -237,8 +237,8 @@
237 237  
238 238  Generally, the EC value of irrigation water is less than 800uS / cm.
239 239  
240 -1.
241 -11.
233 +1.
234 +11.
242 242  111. MOD
243 243  
244 244  Firmware version at least v2.1 supports changing mode.
... ... @@ -255,8 +255,8 @@
255 255  If** **payload =** **0x0A01, workmode=1
256 256  
257 257  
258 -1.
259 -11.
251 +1.
252 +11.
260 260  111. ​Decode payload in The Things Network
261 261  
262 262  While using TTN network, you can add the payload format to decode the payload.
... ... @@ -269,7 +269,7 @@
269 269  LSE01 TTN Payload Decoder: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/>>url:http://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/LSE01/Payload_Decoder/]]
270 270  
271 271  
272 -1.
265 +1.
273 273  11. Uplink Interval
274 274  
275 275  The LSE01 by default uplink the sensor data every 20 minutes. User can change this interval by AT Command or LoRaWAN Downlink Command. See this link:
... ... @@ -276,7 +276,7 @@
276 276  
277 277  [[http:~~/~~/wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval>>url:http://wiki.dragino.com/index.php?title=End_Device_AT_Commands_and_Downlink_Commands#Change_Uplink_Interval]]
278 278  
279 -1.
272 +1.
280 280  11. ​Downlink Payload
281 281  
282 282  By default, LSE50 prints the downlink payload to console port.
... ... @@ -309,7 +309,7 @@
309 309  
310 310  Downlink Payload: 05000001, Set AT+CFM=1 or 05000000 , set AT+CFM=0
311 311  
312 -1.
305 +1.
313 313  11. ​Show Data in DataCake IoT Server
314 314  
315 315  [[DATACAKE>>url:https://datacake.co/]] provides a human friendly interface to show the sensor data, once we have data in TTN, we can use [[DATACAKE>>url:https://datacake.co/]] to connect to TTN and see the data in DATACAKE. Below are the steps:
... ... @@ -350,8 +350,8 @@
350 350  
351 351  The LSE01 uses OTAA mode and below frequency plans by default. If user want to use it with different frequency plan, please refer the AT command sets.
352 352  
353 -1.
354 -11.
346 +1.
347 +11.
355 355  111. EU863-870 (EU868)
356 356  
357 357  Uplink:
... ... @@ -382,8 +382,8 @@
382 382  869.525 - SF9BW125 (RX2 downlink only)
383 383  
384 384  
385 -1.
386 -11.
378 +1.
379 +11.
387 387  111. US902-928(US915)
388 388  
389 389  Used in USA, Canada and South America. Default use CHE=2
... ... @@ -428,8 +428,8 @@
428 428  923.3 - SF12BW500(RX2 downlink only)
429 429  
430 430  
431 -1.
432 -11.
424 +1.
425 +11.
433 433  111. CN470-510 (CN470)
434 434  
435 435  Used in China, Default use CHE=1
... ... @@ -474,8 +474,8 @@
474 474  505.3 - SF12BW125 (RX2 downlink only)
475 475  
476 476  
477 -1.
478 -11.
470 +1.
471 +11.
479 479  111. AU915-928(AU915)
480 480  
481 481  Default use CHE=2
... ... @@ -519,8 +519,8 @@
519 519  
520 520  923.3 - SF12BW500(RX2 downlink only)
521 521  
522 -1.
523 -11.
515 +1.
516 +11.
524 524  111. AS920-923 & AS923-925 (AS923)
525 525  
526 526  **Default Uplink channel:**
... ... @@ -572,8 +572,8 @@
572 572  923.2 - SF10BW125 (RX2)
573 573  
574 574  
575 -1.
576 -11.
568 +1.
569 +11.
577 577  111. KR920-923 (KR920)
578 578  
579 579  Default channel:
... ... @@ -609,8 +609,8 @@
609 609  921.9 - SF12BW125 (RX2 downlink only; SF12BW125 might be changed to SF9BW125)
610 610  
611 611  
612 -1.
613 -11.
605 +1.
606 +11.
614 614  111. IN865-867 (IN865)
615 615  
616 616  Uplink:
... ... @@ -629,7 +629,7 @@
629 629  866.550 - SF10BW125 (RX2)
630 630  
631 631  
632 -1.
625 +1.
633 633  11. LED Indicator
634 634  
635 635  The LSE01 has an internal LED which is to show the status of different state.
... ... @@ -639,7 +639,7 @@
639 639  * Solid ON for 5 seconds once device successful Join the network.
640 640  * Blink once when device transmit a packet.
641 641  
642 -1.
635 +1.
643 643  11. Installation in Soil
644 644  
645 645  **Measurement the soil surface**
... ... @@ -666,7 +666,7 @@
666 666  
667 667  
668 668  
669 -1.
662 +1.
670 670  11. ​Firmware Change Log
671 671  
672 672  **Firmware download link:**
... ... @@ -685,7 +685,7 @@
685 685  
686 686  
687 687  
688 -1.
681 +1.
689 689  11. ​Battery Analysis
690 690  111. ​Battery Type
691 691  
... ... @@ -709,15 +709,15 @@
709 709  
710 710  
711 711  
712 -1.
713 -11.
705 +1.
706 +11.
714 714  111. ​Battery Note
715 715  
716 716  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
717 717  
718 718  
719 -1.
720 -11.
712 +1.
713 +11.
721 721  111. ​Replace the battery
722 722  
723 723  If Battery is lower than 2.7v, user should replace the battery of LSE01.
1654504881641-514.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +119.4 KB
Content
1654504907647-967.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +54.7 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0