Changes for page N95S31B -- NB-IoT Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:44
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Edwin1 +XWiki.Xiaoling - Content
-
... ... @@ -68,6 +68,7 @@ 68 68 * Micro SIM card slot for NB-IoT SIM 69 69 * 8500mAh Battery for long term use 70 70 71 + 71 71 == 1.3 Specification == 72 72 73 73 ... ... @@ -93,6 +93,7 @@ 93 93 * Max continuously current: 130mA 94 94 * Max boost current: 2A, 1 second 95 95 97 + 96 96 == 1.4 Applications == 97 97 98 98 ... ... @@ -154,6 +154,7 @@ 154 154 1. When boot the device in flash mode 155 155 1. Send an uplink packet 156 156 159 + 157 157 = 2. Use N95S31B to communicate with IoT Server = 158 158 159 159 ... ... @@ -587,6 +587,9 @@ 587 587 588 588 * 8 sets of recorded data: SHTTEM,SHTHUM,Time stamp : //**0113023163199c5e**//,....... 589 589 593 + 594 + 595 + 590 590 === 2.3.2 Device ID === 591 591 592 592 ... ... @@ -596,12 +596,10 @@ 596 596 597 597 ((( 598 598 User can use (% style="color:blue" %)**AT+DEUI**(%%) to set Device ID 599 - 600 - 601 601 ))) 602 602 603 603 ((( 604 - (% style="color:blue" %)**Example:**608 +**Example:** 605 605 ))) 606 606 607 607 ((( ... ... @@ -609,25 +609,23 @@ 609 609 ))) 610 610 611 611 ((( 612 -The Device ID is stored in a none-erase area, Upgrade the firmware or run (% style="color:blue" %)**AT+FDR**(%%)won't erase Device ID.616 +The Device ID is stored in a none-erase area, Upgrade the firmware or run **AT+FDR** won't erase Device ID. 613 613 614 614 615 615 ))) 616 616 617 -(% style="color:red" %)**NOTE: 621 +(% style="color:red" %)**NOTE:When the firmware version is v1.2 and later firmware:** 618 618 619 619 620 620 By default, the Device ID equal to the last 15 bits of IMEI. 621 621 622 -User can use ** (% style="color:blue" %)AT+DEUI(%%)** to set Device ID626 +User can use **AT+DEUI** to set Device ID 623 623 628 +**Example:** 624 624 625 -**(% style="color:blue" %)Example:(%%)** 626 - 627 627 AT+DEUI=868411056754138 628 628 629 629 630 - 631 631 === 2.3.3 Version Info === 632 632 633 633 ... ... @@ -773,16 +773,12 @@ 773 773 ))) 774 774 775 775 778 +== 2.5 Humidity and Temperature alarm function == 776 776 777 - ==2.5Humidity and Temperature alarm function ==780 +➢ AT Command: 778 778 782 +AT+ SHHUM=min,max 779 779 780 -**~ (% style="color:blue" %)➢ AT Command:(%%)** 781 - 782 - 783 -(% style="color:#037691" %)**AT+ SHHUM=min,max** 784 - 785 - 786 786 ² When min=0, and max≠0, Alarm higher than max 787 787 788 788 ² When min≠0, and max=0, Alarm lower than min ... ... @@ -789,13 +789,12 @@ 789 789 790 790 ² When min≠0 and max≠0, Alarm higher than max or lower than min 791 791 790 +Example: 792 792 793 - (% style="color:blue" %)**Example:** 794 - 795 795 AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50. 796 796 797 797 798 - (% style="color:#037691" %)**AT+ SHTEMP=min,max**795 +AT+ SHTEMP=min,max 799 799 800 800 ² When min=0, and max≠0, Alarm higher than max 801 801 ... ... @@ -803,39 +803,28 @@ 803 803 804 804 ² When min≠0 and max≠0, Alarm higher than max or lower than min 805 805 803 +Example: 806 806 807 -**~ (% style="color:blue" %)Example:(%%)** 808 - 809 809 AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20. 810 810 811 - 812 - 813 813 == 2.6 Set the number of data to be uploaded and the recording time == 814 814 809 +➢ AT Command: 815 815 816 - **~(%style="color:blue"%)➢ATCommand:(%%)**811 +AT+TR=900 ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 817 817 818 -* (% style="color:#037691" %)**AT+TR=900** (%%)~/~/ The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 819 -* (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 813 +AT+NOUD=8 ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 820 820 821 - The diagram below explains the relationship between TR, NOUD, and TDC more clearly**:** 822 - 823 -[[image:image-20221009000513-1.png||height="732" width="1018"]] 824 - 825 - 826 - 827 827 == 2.7 Read or Clear cached data == 828 828 817 +➢ AT Command: 829 829 830 - **~(%style="color:blue"%)➢ATCommand:(%%)**819 +AT+CDP ~/~/ Read cached data 831 831 832 -* (% style="color:#037691" %)**AT+CDP** (%%) ~/~/ Read cached data 833 -* (% style="color:#037691" %)**AT+CDP=0** (%%) ~/~/ Clear cached data 834 - 835 835 [[image:image-20220908163102-2.png]] 836 836 823 +AT+CDP=0 ~/~/ Clear cached data 837 837 838 - 839 839 == 2.8 Battery Analysis == 840 840 841 841 ... ... @@ -1108,5 +1108,3 @@ 1108 1108 1109 1109 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1110 1110 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1111 - 1112 -
- image-20221009001045-1.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.Edwin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -282.9 KB - Content