Changes for page N95S31B -- NB-IoT Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:44
Change comment:
Uploaded new attachment "image-20221009001045-1.png", version {1}
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.Edwin - Content
-
... ... @@ -68,7 +68,6 @@ 68 68 * Micro SIM card slot for NB-IoT SIM 69 69 * 8500mAh Battery for long term use 70 70 71 - 72 72 == 1.3 Specification == 73 73 74 74 ... ... @@ -94,7 +94,6 @@ 94 94 * Max continuously current: 130mA 95 95 * Max boost current: 2A, 1 second 96 96 97 - 98 98 == 1.4 Applications == 99 99 100 100 ... ... @@ -156,7 +156,6 @@ 156 156 1. When boot the device in flash mode 157 157 1. Send an uplink packet 158 158 159 - 160 160 = 2. Use N95S31B to communicate with IoT Server = 161 161 162 162 ... ... @@ -590,9 +590,6 @@ 590 590 591 591 * 8 sets of recorded data: SHTTEM,SHTHUM,Time stamp : //**0113023163199c5e**//,....... 592 592 593 - 594 - 595 - 596 596 === 2.3.2 Device ID === 597 597 598 598 ... ... @@ -607,7 +607,7 @@ 607 607 ))) 608 608 609 609 ((( 610 - **(% style="color:blue" %)Example:**604 +(% style="color:blue" %)**Example:** 611 611 ))) 612 612 613 613 ((( ... ... @@ -615,7 +615,7 @@ 615 615 ))) 616 616 617 617 ((( 618 -The Device ID is stored in a none-erase area, Upgrade the firmware or run **(% style="color:blue" %)AT+FDR**(%%) won't erase Device ID.612 +The Device ID is stored in a none-erase area, Upgrade the firmware or run (% style="color:blue" %)**AT+FDR**(%%) won't erase Device ID. 619 619 620 620 621 621 ))) ... ... @@ -625,10 +625,10 @@ 625 625 626 626 By default, the Device ID equal to the last 15 bits of IMEI. 627 627 628 -User can use ** (% style="color:blue" %)AT+DEUI **(%%) to set Device ID622 +User can use ** (% style="color:blue" %)AT+DEUI(%%)** to set Device ID 629 629 630 630 631 -** 625 +**(% style="color:blue" %)Example:(%%)** 632 632 633 633 AT+DEUI=868411056754138 634 634 ... ... @@ -779,12 +779,16 @@ 779 779 ))) 780 780 781 781 782 -== 2.5 Humidity and Temperature alarm function == 783 783 784 - ➢ATCommand:777 +== 2.5 Humidity and Temperature alarm function == 785 785 786 -AT+ SHHUM=min,max 787 787 780 +**~ (% style="color:blue" %)➢ AT Command:(%%)** 781 + 782 + 783 +(% style="color:#037691" %)**AT+ SHHUM=min,max** 784 + 785 + 788 788 ² When min=0, and max≠0, Alarm higher than max 789 789 790 790 ² When min≠0, and max=0, Alarm lower than min ... ... @@ -791,12 +791,13 @@ 791 791 792 792 ² When min≠0 and max≠0, Alarm higher than max or lower than min 793 793 794 -Example: 795 795 793 + (% style="color:blue" %)**Example:** 794 + 796 796 AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50. 797 797 798 798 799 -AT+ SHTEMP=min,max 798 +(% style="color:#037691" %)**AT+ SHTEMP=min,max** 800 800 801 801 ² When min=0, and max≠0, Alarm higher than max 802 802 ... ... @@ -804,28 +804,39 @@ 804 804 805 805 ² When min≠0 and max≠0, Alarm higher than max or lower than min 806 806 807 -Example: 808 808 807 +**~ (% style="color:blue" %)Example:(%%)** 808 + 809 809 AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20. 810 810 811 + 812 + 811 811 == 2.6 Set the number of data to be uploaded and the recording time == 812 812 813 -➢ AT Command: 814 814 815 - AT+TR=900~/~/Theunitisseconds, andthe default is to record dataonce every 900 seconds.(Theminimum canbe set to 180 seconds)816 +**~ (% style="color:blue" %)➢ AT Command:(%%)** 816 816 817 -AT+NOUD=8 ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 818 +* (% style="color:#037691" %)**AT+TR=900** (%%)~/~/ The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 819 +* (% style="color:#037691" %)**AT+NOUD=8** (%%)~/~/ The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 818 818 821 + The diagram below explains the relationship between TR, NOUD, and TDC more clearly**:** 822 + 823 +[[image:image-20221009000513-1.png||height="732" width="1018"]] 824 + 825 + 826 + 819 819 == 2.7 Read or Clear cached data == 820 820 821 -➢ AT Command: 822 822 823 - AT+CDP~/~/Readcacheddata830 +**~ (% style="color:blue" %)➢ AT Command:(%%)** 824 824 832 +* (% style="color:#037691" %)**AT+CDP** (%%) ~/~/ Read cached data 833 +* (% style="color:#037691" %)**AT+CDP=0** (%%) ~/~/ Clear cached data 834 + 825 825 [[image:image-20220908163102-2.png]] 826 826 827 -AT+CDP=0 ~/~/ Clear cached data 828 828 838 + 829 829 == 2.8 Battery Analysis == 830 830 831 831 ... ... @@ -1098,3 +1098,5 @@ 1098 1098 1099 1099 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 1100 1100 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1111 + 1112 +
- image-20221009001045-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Edwin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +282.9 KB - Content