From version < 125.4 >
edited by Xiaoling
on 2022/09/09 15:57
To version < 125.6 >
edited by Xiaoling
on 2022/09/09 16:25
>
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -68,7 +68,6 @@
68 68  * Micro SIM card slot for NB-IoT SIM
69 69  * 8500mAh Battery for long term use
70 70  
71 -
72 72  == 1.3  Specification ==
73 73  
74 74  
... ... @@ -94,7 +94,6 @@
94 94  * Max continuously current: 130mA
95 95  * Max boost current: 2A, 1 second
96 96  
97 -
98 98  == ​1.4  Applications ==
99 99  
100 100  
... ... @@ -156,7 +156,6 @@
156 156  1. When boot the device in flash mode
157 157  1. Send an uplink packet
158 158  
159 -
160 160  = 2.  Use N95S31B to communicate with IoT Server =
161 161  
162 162  
... ... @@ -592,7 +592,6 @@
592 592  
593 593  
594 594  
595 -
596 596  === 2.3.2  Device ID ===
597 597  
598 598  
... ... @@ -607,7 +607,7 @@
607 607  )))
608 608  
609 609  (((
610 -** (% style="color:blue" %)Example:**
606 +**​​​​​​​(% style="color:blue" %)Example:(%%)**
611 611  )))
612 612  
613 613  (((
... ... @@ -615,7 +615,7 @@
615 615  )))
616 616  
617 617  (((
618 -The Device ID is stored in a none-erase area, Upgrade the firmware or run ** (% style="color:blue" %)AT+FDR**(%%) won't erase Device ID.
614 +The Device ID is stored in a none-erase area, Upgrade the firmware or run (% style="color:blue" %)**AT+FDR**(%%) won't erase Device ID.
619 619  
620 620  
621 621  )))
... ... @@ -625,10 +625,10 @@
625 625  
626 626  By default, the Device ID equal to the last 15 bits of IMEI.
627 627  
628 -User can use ** (% style="color:blue" %)AT+DEUI**(%%) to set Device ID
624 +User can use ** (% style="color:blue" %)AT+DEUI(%%)** to set Device ID
629 629  
630 630  
631 -** (% style="color:blue" %)Example:**
627 +**​​​​​​​​​​​​​​(% style="color:blue" %)Example:(%%)**
632 632  
633 633  AT+DEUI=868411056754138
634 634  
... ... @@ -779,12 +779,16 @@
779 779  )))
780 780  
781 781  
782 -== 2.5 Humidity and Temperature alarm function ==
783 783  
784 - AT Command:
779 +== 2.5  Humidity and Temperature alarm function ==
785 785  
786 -AT+ SHHUM=min,max
787 787  
782 +**~ (% style="color:blue" %)➢ AT Command:(%%)**
783 +
784 +
785 +(% style="color:#037691" %)**AT+ SHHUM=min,max**
786 +
787 +
788 788  ² When min=0, and max≠0, Alarm higher than max
789 789  
790 790  ² When min≠0, and max=0, Alarm lower than min
... ... @@ -791,12 +791,13 @@
791 791  
792 792  ² When min≠0 and max≠0, Alarm higher than max or lower than min
793 793  
794 -Example:
795 795  
795 + (% style="color:blue" %)**Example:**
796 +
796 796  AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50.
797 797  
798 798  
799 -AT+ SHTEMP=min,max
800 +(% style="color:#037691" %)**AT+ SHTEMP=min,max**
800 800  
801 801  ² When min=0, and max≠0, Alarm higher than max
802 802  
... ... @@ -804,28 +804,38 @@
804 804  
805 805  ² When min≠0 and max≠0, Alarm higher than max or lower than min
806 806  
807 -Example:
808 808  
809 +**~ (% style="color:blue" %)Example:(%%)**
810 +
809 809  AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20.
810 810  
813 +
814 +
811 811  == 2.6 Set the number of data to be uploaded and the recording time ==
812 812  
813 -➢ AT Command:
814 814  
815 -AT+TR=900  ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
818 +**~ (% style="color:blue" %)➢ AT Command:(%%)**
816 816  
817 -AT+NOUD=8  ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
820 +* (% style="color:#037691" %)**AT+TR=900**  (%%)~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
821 +* (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
818 818  
823 +
824 +
825 +
819 819  == 2.7 Read or Clear cached data ==
820 820  
821 -➢ AT Command:
822 822  
823 -AT+CDP ~/~/ Read cached data
829 +**~ (% style="color:blue" %)➢ AT Command:(%%)**
824 824  
831 +* (% style="color:#037691" %)**AT+CDP**  (%%) ~/~/ Read cached data
832 +* (% style="color:#037691" %)**AT+CDP=0** (%%) ~/~/  Clear cached data
833 +
834 +
835 +
825 825  [[image:image-20220908163102-2.png]]
826 826  
827 -AT+CDP=0 ~/~/ Clear cached data
828 828  
839 +
829 829  == 2.8  ​Battery Analysis ==
830 830  
831 831  
... ... @@ -1098,3 +1098,7 @@
1098 1098  
1099 1099  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1100 1100  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1112 +
1113 +
1114 +
1115 +
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0