Changes for page N95S31B -- NB-IoT Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:44
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -9,6 +9,7 @@ 9 9 10 10 **Table of Contents:** 11 11 12 +{{toc/}} 12 12 13 13 14 14 ... ... @@ -16,21 +16,35 @@ 16 16 17 17 = 1. Introduction = 18 18 20 + 19 19 == 1.1 What is N95S31B NB-IoT Sensor Node == 20 20 21 21 ((( 22 22 23 23 26 +((( 24 24 The Dragino N95S31B is a (% style="color:blue" %)**NB-IoT Temperature and Humidity Sensor**(%%) for Internet of Things solution. It is used to measure the (% style="color:blue" %)**surrounding environment temperature and relative air humidity precisely**(%%), and then upload to IoT server via NB-IoT network*. 28 +))) 25 25 30 +((( 26 26 The temperature & humidity sensor used in N95S31B is SHT31, which is fully calibrated, linearized, and temperature compensated digital output from Sensirion, it provides a strong reliability and long-term stability. The SHT31 is fixed in a (% style="color:blue" %)**waterproof anti-condensation casing **(%%)for long term use. 32 +))) 27 27 34 +((( 28 28 N95S31B supports different uplink methods include (% style="color:blue" %)**TCP, MQTT, UDP and CoAP**(%%) for different application requirement. 36 +))) 29 29 38 +((( 30 30 N95S31B is powered by(% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to several years. (Real-world battery life depends on the use environment, update period. Please check related Power Analyze report). 40 +))) 31 31 42 +((( 43 + 44 +))) 32 32 46 +((( 33 33 ~* make sure you have NB-IoT coverage locally. 48 +))) 34 34 35 35 36 36 ))) ... ... @@ -41,6 +41,7 @@ 41 41 42 42 == 1.2 Features == 43 43 59 + 44 44 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD 45 45 * Monitor Temperature & Humidity via SHT31 46 46 * AT Commands to change parameters ... ... @@ -53,8 +53,6 @@ 53 53 * 8500mAh Battery for long term use 54 54 55 55 56 - 57 - 58 58 == 1.3 Specification == 59 59 60 60 ... ... @@ -74,7 +74,6 @@ 74 74 75 75 (% style="color:#037691" %)**Battery:** 76 76 77 - 78 78 * Li/SOCI2 un-chargeable battery 79 79 * Capacity: 8500mAh 80 80 * Self Discharge: <1% / Year @ 25°C ... ... @@ -82,10 +82,9 @@ 82 82 * Max boost current: 2A, 1 second 83 83 84 84 85 - 86 - 87 87 == 1.4 Applications == 88 88 100 + 89 89 * Smart Buildings & Home Automation 90 90 * Logistics and Supply Chain Management 91 91 * Smart Metering ... ... @@ -97,15 +97,21 @@ 97 97 98 98 99 99 100 -== 1.5 Pin Definitions == 101 101 113 + 114 +== 1.5 Pin Definitions & Switch == 115 + 116 + 102 102 N95S31B use the mother board from NBSN95 which as below. 103 103 119 + 104 104 [[image:image-20220709144723-1.png]] 105 105 106 106 123 + 107 107 === 1.5.1 Jumper JP2 === 108 108 126 + 109 109 Power on Device when put this jumper. 110 110 111 111 ... ... @@ -112,14 +112,20 @@ 112 112 113 113 === 1.5.2 BOOT MODE / SW1 === 114 114 133 + 134 +((( 115 115 1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run. 136 +))) 116 116 138 +((( 117 117 2) Flash: work mode, device starts to work and send out console output for further debug 140 +))) 118 118 119 119 120 120 121 121 === 1.5.3 Reset Button === 122 122 146 + 123 123 Press to reboot the device. 124 124 125 125 ... ... @@ -126,6 +126,7 @@ 126 126 127 127 === 1.5.4 LED === 128 128 153 + 129 129 It will flash: 130 130 131 131 1. When boot the device in flash mode ... ... @@ -134,6 +134,7 @@ 134 134 135 135 = 2. Use N95S31B to communicate with IoT Server = 136 136 162 + 137 137 == 2.1 How it works == 138 138 139 139 ... ... @@ -150,7 +150,7 @@ 150 150 151 151 ))) 152 152 153 -[[image:1657 350248151-650.png]]179 +[[image:1657520100595-569.png]] 154 154 155 155 ((( 156 156 ... ... @@ -166,26 +166,49 @@ 166 166 [[image:image-20220709150546-2.png]] 167 167 168 168 195 + 169 169 === 2.2.1 Test Requirement === 170 170 171 171 199 +((( 172 172 To use N95S31B in your city, make sure meet below requirements: 201 +))) 173 173 174 -* Your local operator has already distributed a NB-IoT Network there. 175 -* The local NB-IoT network used the band that N95S31B supports. 176 -* Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 203 +* ((( 204 +Your local operator has already distributed a NB-IoT Network there. 205 +))) 206 +* ((( 207 +The local NB-IoT network used the band that N95S31B supports. 208 +))) 209 +* ((( 210 +Your operator is able to distribute the data received in their NB-IoT network to your IoT server. 211 +))) 177 177 213 +((( 178 178 Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8. 215 +))) 179 179 217 +((( 180 180 N95S31B supports different communication protocol such as : 219 +))) 181 181 182 182 ((( 183 -* CoAP ((% style="color:red" %)120.24.4.116:5683(%%)) 184 -* raw UDP ((% style="color:red" %)120.24.4.116:5601(%%)) 185 -* MQTT ((% style="color:red" %)120.24.4.116:1883(%%)) 186 -* TCP ((% style="color:red" %)120.24.4.116:5600(%%)) 222 +* ((( 223 +CoAP ((% style="color:red" %)120.24.4.116:5683(%%)) 224 +))) 225 +* ((( 226 +raw UDP ((% style="color:red" %)120.24.4.116:5601(%%)) 227 +))) 228 +* ((( 229 +MQTT ((% style="color:red" %)120.24.4.116:1883(%%)) 230 +))) 231 +* ((( 232 +TCP ((% style="color:red" %)120.24.4.116:5600(%%)) 233 +))) 187 187 235 +((( 188 188 We will show how to use with each protocol. The IP addresses above are our test server. User need to change to point their corresponding server. 237 +))) 189 189 190 190 191 191 ))) ... ... @@ -196,6 +196,7 @@ 196 196 197 197 === 2.2.3 Insert SIM card === 198 198 248 + 199 199 ((( 200 200 Insert the NB-IoT Card get from your provider. 201 201 ))) ... ... @@ -211,14 +211,18 @@ 211 211 212 212 === 2.2.4 Connect USB – TTL to N95S31B to configure it === 213 213 264 + 214 214 ((( 215 215 ((( 216 216 User need to configure N95S31B via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic** (%%)to define where and how-to uplink packets. N95S31B support AT Commands, user can use a USB to TTL adapter to connect to N95S31B and use AT Commands to configure it, as below. 268 + 269 + 217 217 ))) 218 218 ))) 219 219 220 220 [[image:1657351312545-300.png]] 221 221 275 + 222 222 **Connection:** 223 223 224 224 (% style="background-color:yellow" %)USB TTL GND <~-~-~-~-> GND ... ... @@ -242,8 +242,9 @@ 242 242 243 243 [[image:1657329814315-101.png]] 244 244 299 + 245 245 ((( 246 -(% style="color:red" %)Note: the valid AT Commands can be found at: (%%)[[https:~~/~~/www.dr agino.com/downloads/index.php?dir=NB-IoT/N95S31B/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/]]301 +(% style="color:red" %)**Note: the valid AT Commands can be found at: **(%%)**[[https:~~/~~/www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i~~-~~-AyZcQkoua?dl=0>>https://www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i--AyZcQkoua?dl=0]]** 247 247 ))) 248 248 249 249 ... ... @@ -250,9 +250,10 @@ 250 250 251 251 === 2.2.5 Use CoAP protocol to uplink data === 252 252 253 -(% style="color:red" %)Note: if you don't have CoAP server, you can refer this link to set up one: (%%)[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 254 254 309 +(% style="color:red" %)**Note: if you don't have CoAP server, you can refer this link to set up one: **(%%)**[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]** 255 255 311 + 256 256 ((( 257 257 **Use below commands:** 258 258 ))) ... ... @@ -300,6 +300,7 @@ 300 300 301 301 === 2.2.7 Use MQTT protocol to uplink data === 302 302 359 + 303 303 N95S31B supports only plain MQTT now it doesn't support TLS and other related encryption. 304 304 305 305 * (% style="color:blue" %)**AT+PRO=3 ** (%%) ~/~/Set to use MQTT protocol to uplink ... ... @@ -315,6 +315,7 @@ 315 315 316 316 [[image:1657352645687-385.png]] 317 317 375 + 318 318 ((( 319 319 To save battery life, N95S31B will establish a subscription before each uplink and close the subscription 3 seconds after uplink successful. Any downlink commands from server will only arrive during the subscription period. 320 320 ))) ... ... @@ -328,6 +328,7 @@ 328 328 329 329 === 2.2.8 Use TCP protocol to uplink data === 330 330 389 + 331 331 This feature is supported since firmware version v110 332 332 333 333 * (% style="color:blue" %)**AT+PRO=4 ** (%%) ~/~/ Set to use TCP protocol to uplink ... ... @@ -342,6 +342,7 @@ 342 342 343 343 === 2.2.9 Change Update Interval === 344 344 404 + 345 345 User can use below command to change the (% style="color:green" %)**uplink interval**. 346 346 347 347 * (% style="color:blue" %)**AT+TDC=600 ** (%%)~/~/ Set Update Interval to 600s ... ... @@ -350,58 +350,104 @@ 350 350 351 351 ))) 352 352 413 +((( 414 +(% style="color:red" %)**NOTE: Since firmware version is v1.2:** 415 +))) 353 353 417 +((( 418 +(% style="color:red" %)**By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).** 419 +))) 354 354 421 + 422 + 355 355 == 2.3 Uplink Payload == 356 356 357 357 358 -NBSN95 has different working mode for the connections of different type of sensors. This section describes these modes. User can use the AT Command (% style="color:blue" %)**AT+MOD**(%%) to set NBSN95 to different working modes. 426 +((( 427 +N95S31B has different working modes for the connections of different types of sensors. This section describes these modes. User can use the AT Command (% style="color:blue" %)**AT+MOD**(%%) to set NBSN95 to different working modes. 428 +))) 359 359 360 360 431 +((( 361 361 For example: 433 +))) 362 362 363 - (% style="color:blue" %)**AT+CFGMOD=2 ** (%%)~/~/will set the NBSN95 to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor. 435 +((( 436 + (% style="color:blue" %)**AT+CFGMOD=2 ** (%%)~/~/will set the N95S31B to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor. 437 +))) 364 364 365 365 440 +((( 366 366 The uplink payloads are composed in ASCII String. For example: 442 +))) 367 367 444 +((( 368 368 0a cd 00 ed 0a cc 00 00 ef 02 d2 1d (total 24 ASCII Chars) . Representative the actually payload: 446 +))) 369 369 448 +((( 370 370 0x 0a cd 00 ed 0a cc 00 00 ef 02 d2 1d Total 12 bytes 450 +))) 371 371 372 372 453 +((( 373 373 (% style="color:red" %)**NOTE:** 455 +))) 374 374 375 375 (% style="color:red" %) 376 -1. All modes share the same Payload Explanation from [[HERE>>path:#Payload_Explain]]. 377 -1. By default, the device will send an uplink message every 1 hour. 458 +1. ((( 459 +**All modes share the same Payload Explanation from [[HERE>>||anchor="H2.3A0UplinkPayload"]].** 460 +))) 461 +1. ((( 462 +**By default, the device will send an uplink message every 1 hour.** 378 378 379 379 380 380 466 + 467 +))) 468 + 381 381 === 2.3.1 Payload Analyze === 382 382 471 + 472 +==== 2.3.1.1 Before Firmware v1.2 ==== 473 + 474 + 383 383 N95S31B uplink payload includes in total 21 bytes 384 384 385 385 386 -(% border=" 1" cellspacing="10" style="background-color:#ffffcc; color:green; width:440px" %)478 +(% border="2" cellspacing="10" style="background-color:#ffffcc; color:green; width:760px" %) 387 387 |=(% style="width: 60px;" %)((( 388 388 **Size(bytes)** 389 -)))|=(% style="width: 60px;" %)**6**|=(% style="width: 35px;" %)2|=(% style="width: 35px;" %)**2**|=(% style="width: 80px;" %)**1**|=(% style="width: 80px;" %) |=(% style="width: 99px;" %) |=(% style="width: 77px;" %)**2**|=(% style="width: 60px;" %)**1** 390 -|(% style="width:97px" %)**Value**|(% style="width:83px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:41px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:123px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:123px" %)MOD 0X01|(% style="width:99px" %)((( 481 +)))|=(% style="width: 65px;" %)**6**|=(% style="width: 50px;" %)2|=(% style="width: 25px;" %)**2**|=(% style="width: 75px;" %)**1**|=(% style="width: 59px;" %)1|=(% style="width: 174px;" %)5|=(% style="width: 106px;" %)**2**|=(% style="width: 85px;" %)**2** 482 +|(% style="width:97px" %)**Value**|(% style="width:65px" %)[[Device ID>>||anchor="H2.3.2A0DeviceID"]]|(% style="width:50px" %)[[Ver>>||anchor="H2.3.3A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.3.4A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.3.5A0SignalStrength"]]|(% style="width:59px" %)MOD 0X01|(% style="width:174px" %)((( 483 +((( 391 391 Reserve/ Same as NBSN95 CFGMOD=1 485 +))) 392 392 487 +((( 393 393 No function here. 394 -)))|(% style="width:77px" %)((( 395 -[[Temperature >>||anchor="H2.4.5A0Distance"]] 489 +))) 490 +)))|(% style="width:106px" %)((( 491 +((( 492 +[[Temperature >>||anchor="H2.3.6A0Temperature26Humidity"]] 493 +))) 396 396 495 +((( 397 397 By SHT31 398 -)))|(% style="width:80px" %)((( 399 -[[Humidity>>||anchor="H2.4.6A0DigitalInterrupt"]] 497 +))) 498 +)))|(% style="width:85px" %)((( 499 +((( 500 +[[Humidity>>||anchor="H2.3.6A0Temperature26Humidity"]] 501 +))) 400 400 503 +((( 401 401 By SHT31 402 402 ))) 506 +))) 403 403 404 404 ((( 509 + 510 + 405 405 ((( 406 406 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NB sensor uplink data. 407 407 ))) ... ... @@ -413,27 +413,83 @@ 413 413 414 414 The payload is ASCII string, representative same HEX: 0x724031607457006e0ccd1b0100dc000ccc00e10186 where: 415 415 416 -* Device ID: 0x724031607457 = 724031607457 417 -* Version: 0x006e=110=1.1.0 522 +* Device ID: 0x724031607457 = 724031607457 418 418 419 -* BAT: 0x0ccd = 3277 mV = 3.277V 420 -* Signal: 0x1b = 27 421 -* Model: 0x01 = 1 524 +* Version: 0x006e=110=1.1.0 525 + 526 +* BAT: 0x0ccd = 3277 mV = 3.277V 527 + 528 +* Signal: 0x1b = 27 529 + 530 +* Model: 0x01 = 1 531 + 422 422 * 0x00dc000ccc= reserve, ignore in N95S31B 423 -* Temperature by SHT31: 0x00e1 = 225 = 22.5 °C 424 -* Humidity by SHT31: 0x0186 = 390 = 39.0 %rh 425 425 534 +* Temperature by SHT31: 0x00e1 = 225 = 22.5 °C 535 + 536 +* Humidity by SHT31: 0x0186 = 390 = 39.0 %rh 537 + 426 426 ((( 427 427 428 -))) 429 429 430 - (((541 + 431 431 432 432 ))) 433 433 545 +==== 2.3.1.2 Since Firmware v1.2 ==== 434 434 547 + 548 +In this mode, uplink payload includes 91 bytes in total by default. 549 + 550 +Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 551 + 552 + 553 +(% border="2" style="background-color:#ffffcc; color:green; width:1234px" %) 554 +|(% style="width:95px" %)**Size(bytes)**|(% style="width:82px" %)**8**|(% style="width:43px" %)**2**|(% style="width:47px" %)**2**|(% style="width:124px" %)**1**|(% style="width:56px" %)**1**|(% style="width:109px" %)**2**|(% style="width:80px" %)**1**|(% style="width:51px" %)**2**|(% style="width:79px" %)**2**|(% style="width:84px" %)**2**|(% style="width:100px" %)**4**|(% style="width:76px" %)**2**|(% style="width:81px" %)**2**|(% style="width:121px" %)**4** 555 +|(% style="width:95px" %)**Value**|(% style="width:82px" %)Device ID|(% style="width:43px" %)Ver|(% style="width:47px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:56px" %)MOD|(% style="width:109px" %)TemDS18B20|(% style="width:80px" %)Interrupt|(% style="width:51px" %)ADC|(% style="width:79px" %)SHTTEM|(% style="width:84px" %)SHTHUM|(% style="width:100px" %)Time stamp |(% style="width:76px" %)SHTTEM|(% style="width:81px" %)SHTHUM|(% style="width:121px" %)Time stamp ..... 556 + 557 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the N95S31B uplink data. 558 + 559 + 560 +[[image:image-20220908154949-1.png]] 561 + 562 + 563 +The payload is ASCII string, representative same HEX: 564 + 565 +0x(% style="color:red" %)f868411056758782(% style="color:blue" %)000c(% style="color:green" %)0d0f(% style="color:red" %)0c(% style="color:blue" %)01(% style="color:green" %)0000(% style="color:red" %)00**//0030//**(% style="color:blue" %)**//0114//**(% style="color:red" %)**//0231//**(% style="color:green" %)**//63199d3c//**0113023163199d12//**0113023163199c5e**//0112023763199baa//**0112023263199af6**//0111023b631999a7//**0112023b631998f3**//011202426319983f//**01110242631996eb**//(%%) where: 566 + 567 +* (% style="color:red" %)Device ID: f868411056758782 = f868411056758782 568 + 569 +* (% style="color:blue" %)Version: 0x000c=120=1.2 570 + 571 +* (% style="color:green" %)BAT: 0x0d0f = 3343 mV = 3.343V 572 + 573 +* (% style="color:red" %)Singal: 0x0c = 12 574 + 575 +* (% style="color:blue" %)Mod: 0x01 = 1 576 + 577 +* TemDS18B20: 0x0000= 0 = 0 578 + 579 +* (% style="color:green" %)Interrupt: 0x00= 0 580 + 581 +* (% style="color:green" %)adc: 0x0030= 48 582 + 583 +* SHTTEM: 0x0114= 276 = 27.6 584 + 585 +* SHTHUM:0x0231 =561=56.1% 586 + 587 +* (% style="color:red" %)Time stamp : 0x6315537b =1662342011 ([[Unix Epoch Time>>url:http://www.epochconverter.com/]]) 588 + 589 +* (% style="color:red" %)SHTTEM,SHTHUM,Time stamp : 0113023163199d12 590 + 591 +* 8 sets of recorded data: SHTTEM,SHTHUM,Time stamp : //**0113023163199c5e**//,....... 592 + 593 + 594 + 595 + 435 435 === 2.3.2 Device ID === 436 436 598 + 437 437 ((( 438 438 By default, the Device ID equal to the last 6 bytes of IMEI. 439 439 ))) ... ... @@ -440,10 +440,12 @@ 440 440 441 441 ((( 442 442 User can use (% style="color:blue" %)**AT+DEUI**(%%) to set Device ID 605 + 606 + 443 443 ))) 444 444 445 445 ((( 446 -**Example:** 610 +** (% style="color:blue" %)Example:** 447 447 ))) 448 448 449 449 ((( ... ... @@ -451,22 +451,47 @@ 451 451 ))) 452 452 453 453 ((( 454 -The Device ID is stored in a none-erase area, Upgrade the firmware or run **AT+FDR** won't erase Device ID. 618 +The Device ID is stored in a none-erase area, Upgrade the firmware or run ** (% style="color:blue" %)AT+FDR**(%%) won't erase Device ID. 619 + 620 + 455 455 ))) 456 456 623 +(% style="color:red" %)**NOTE: When the firmware version is v1.2 and later firmware:** 457 457 458 458 626 +By default, the Device ID equal to the last 15 bits of IMEI. 627 + 628 +User can use ** (% style="color:blue" %)AT+DEUI**(%%) to set Device ID 629 + 630 + 631 +** (% style="color:blue" %)Example:** 632 + 633 +AT+DEUI=868411056754138 634 + 635 + 636 + 459 459 === 2.3.3 Version Info === 460 460 461 461 640 +((( 462 462 These bytes include the hardware and software version. 642 +))) 463 463 644 +((( 464 464 Higher byte: Specify hardware version: always 0x00 for N95S31B 646 +))) 465 465 648 +((( 466 466 Lower byte: Specify the software version: 0x6E=110, means firmware version 110 650 +))) 467 467 652 +((( 653 + 654 +))) 468 468 656 +((( 469 469 For example: 0x00 6E: this device is N95S31B with firmware version 110. 658 +))) 470 470 471 471 ((( 472 472 ... ... @@ -475,6 +475,7 @@ 475 475 476 476 === 2.3.4 Battery Info === 477 477 667 + 478 478 ((( 479 479 Ex1: 0x0B45 = 2885mV 480 480 ))) ... ... @@ -487,6 +487,7 @@ 487 487 488 488 === 2.3.5 Signal Strength === 489 489 680 + 490 490 ((( 491 491 NB-IoT Network signal Strength. 492 492 ))) ... ... @@ -519,6 +519,7 @@ 519 519 520 520 === 2.3.6 Temperature & Humidity === 521 521 713 + 522 522 The device will be able to get the SHT31 temperature and humidity data now and upload to IoT Server. 523 523 524 524 [[image:image-20220709161741-3.png]] ... ... @@ -535,10 +535,11 @@ 535 535 536 536 537 537 538 -== 2. 5Downlink Payload ==730 +== 2.4 Downlink Payload == 539 539 540 -By default, NDDS75 prints the downlink payload to console port. 541 541 733 +By default, N95S31B prints the downlink payload to console port. 734 + 542 542 [[image:image-20220709100028-1.png]] 543 543 544 544 ... ... @@ -575,7 +575,7 @@ 575 575 ))) 576 576 577 577 ((( 578 -If payload = 0x04FF, it will reset the DDS75771 +If payload = 0x04FF, it will reset the N95S31B 579 579 ))) 580 580 581 581 ... ... @@ -586,14 +586,61 @@ 586 586 ))) 587 587 588 588 782 +== 2.5 Humidity and Temperature alarm function == 589 589 784 +➢ AT Command: 785 + 786 +AT+ SHHUM=min,max 787 + 788 +² When min=0, and max≠0, Alarm higher than max 789 + 790 +² When min≠0, and max=0, Alarm lower than min 791 + 792 +² When min≠0 and max≠0, Alarm higher than max or lower than min 793 + 794 +Example: 795 + 796 +AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50. 797 + 798 + 799 +AT+ SHTEMP=min,max 800 + 801 +² When min=0, and max≠0, Alarm higher than max 802 + 803 +² When min≠0, and max=0, Alarm lower than min 804 + 805 +² When min≠0 and max≠0, Alarm higher than max or lower than min 806 + 807 +Example: 808 + 809 +AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20. 810 + 811 +== 2.6 Set the number of data to be uploaded and the recording time == 812 + 813 +➢ AT Command: 814 + 815 +AT+TR=900 ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 816 + 817 +AT+NOUD=8 ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 818 + 819 +== 2.7 Read or Clear cached data == 820 + 821 +➢ AT Command: 822 + 823 +AT+CDP ~/~/ Read cached data 824 + 825 +[[image:image-20220908163102-2.png]] 826 + 827 +AT+CDP=0 ~/~/ Clear cached data 828 + 590 590 == 2.8 Battery Analysis == 591 591 831 + 592 592 === 2.8.1 Battery Type === 593 593 594 594 595 595 ((( 596 -The N DDS75 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.836 +The N95S31B battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 597 597 ))) 598 598 599 599 ((( ... ... @@ -616,54 +616,35 @@ 616 616 617 617 === 2.8.2 Power consumption Analyze === 618 618 619 -((( 620 -Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval. 621 -))) 622 622 623 - 624 624 ((( 625 -Instruction to use as below:861 +The file **DRAGINO_N95S31B-Power-Analyzer.pdf** from [[https:~~/~~/www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i~~-~~-AyZcQkoua?dl=0>>https://www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i--AyZcQkoua?dl=0]] describes a detail measurement to analyze the power consumption in different case. User can use it for design guideline for their project. 626 626 ))) 627 627 628 628 ((( 629 - (%style="color:blue" %)**Step 1: **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]865 + 630 630 ))) 631 631 632 632 633 -((( 634 -(% style="color:blue" %)**Step 2: **(%%) Open it and choose 635 -))) 869 +=== 2.8.3 Battery Note === 636 636 637 -* ((( 638 -Product Model 639 -))) 640 -* ((( 641 -Uplink Interval 642 -))) 643 -* ((( 644 -Working Mode 645 -))) 646 646 647 647 ((( 648 - And the Life expectation in difference casewillbe shownon theright.873 +The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to uplink data, then the battery life may be decreased. 649 649 ))) 650 650 651 -[[image:image-20220709110451-3.png]] 652 652 653 653 878 +=== 2.8.4 Replace the battery === 654 654 655 -=== 2.8.3 Battery Note === 656 656 657 657 ((( 658 - TheLi-SICObattery isdesignedfor smallcurrent/long period application.It isnotgoodtouseahigh current,shortperiodtransmitmethod.Thecommendedminimumperiodforuseofthisbatteryis5minutes. If you use ashorter period time totransmitLoRa,then the batterylifemaybe decreased.882 +You can change the battery in the N95S31B.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board. 659 659 ))) 660 660 661 661 662 - 663 -=== 2.8.4 Replace the battery === 664 - 665 665 ((( 666 -The default battery pack of N DDS75 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).887 +The default battery pack of N95S31B includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes). 667 667 ))) 668 668 669 669 ... ... @@ -670,6 +670,7 @@ 670 670 671 671 = 3. Access NB-IoT Module = 672 672 894 + 673 673 ((( 674 674 Users can directly access the AT command set of the NB-IoT module. 675 675 ))) ... ... @@ -676,6 +676,8 @@ 676 676 677 677 ((( 678 678 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 901 + 902 + 679 679 ))) 680 680 681 681 [[image:1657333200519-600.png]] ... ... @@ -684,11 +684,13 @@ 684 684 685 685 = 4. Using the AT Commands = 686 686 911 + 687 687 == 4.1 Access AT Commands == 688 688 689 -See this link for detail: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NDDS75/>>url:http://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN50/]] 690 690 915 +See NBSN95 AT Command in this link for detail: [[https:~~/~~/www.dropbox.com/sh/jao1xt9kw5r3yq4/AAAMpJkZzExF2JLbRWxGoQ9Na?dl=0>>https://www.dropbox.com/sh/jao1xt9kw5r3yq4/AAAMpJkZzExF2JLbRWxGoQ9Na?dl=0]] 691 691 917 + 692 692 AT+<CMD>? : Help on <CMD> 693 693 694 694 AT+<CMD> : Run <CMD> ... ... @@ -728,7 +728,24 @@ 728 728 729 729 AT+SERVADDR : Server Address 730 730 957 +AT+TR : Get or Set record time 731 731 959 +AT+APN : Get or set the APN 960 + 961 +AT+FBAND : Get or Set whether to automatically modify the frequency band 962 + 963 +AT+DNSCFG : Get or Set DNS Server 964 + 965 +AT+GETSENSORVALUE : Returns the current sensor measurement 966 + 967 +AT+NOUD : Get or Set the number of data to be uploaded 968 + 969 +AT+CDP : Read or Clear cached data 970 + 971 +AT+SHTEMP: Get or Set alarm of temp 972 + 973 +AT+SHHUM: Get or Set alarm of moisture 974 + 732 732 (% style="color:#037691" %)**COAP Management** 733 733 734 734 AT+URI : Resource parameters ... ... @@ -762,6 +762,7 @@ 762 762 763 763 = 5. FAQ = 764 764 1008 + 765 765 == 5.1 How to Upgrade Firmware == 766 766 767 767 ... ... @@ -774,13 +774,18 @@ 774 774 ))) 775 775 776 776 ((( 777 -(% style="color:red" %)Notice, NDDS75 and LDDS75 share the same mother board. They use the same connection and method to update. 1021 + 1022 + 1023 +((( 1024 +(% style="color:red" %)**Notice, N95S31B and LSN50v2 share the same mother board. They use the same connection and method to update.** 778 778 ))) 1026 +))) 779 779 780 780 781 781 782 782 = 6. Trouble Shooting = 783 783 1032 + 784 784 == 6.1 Connection problem when uploading firmware == 785 785 786 786 ... ... @@ -796,6 +796,7 @@ 796 796 797 797 == 6.2 AT Command input doesn't work == 798 798 1048 + 799 799 ((( 800 800 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 801 801 ... ... @@ -806,7 +806,7 @@ 806 806 = 7. Order Info = 807 807 808 808 809 -Part Number**:** (% style="color:#4f81bd" %)**N SDDS75**1059 +Part Number**:** (% style="color:#4f81bd" %)**N95S31B-YY** 810 810 811 811 812 812 (% class="wikigeneratedid" %) ... ... @@ -821,7 +821,7 @@ 821 821 822 822 (% style="color:#037691" %)**Package Includes**: 823 823 824 -* NS E01DistanceDetectSensorNode x 11074 +* N95S31B NB-IoT Temperature and Humidity Sensor 825 825 * External antenna x 1 826 826 ))) 827 827 ... ... @@ -830,11 +830,10 @@ 830 830 831 831 (% style="color:#037691" %)**Dimension and weight**: 832 832 833 - 834 834 * Device Size: 13.0 x 5 x 4.5 cm 835 835 * Device Weight: 150g 836 -* Package Size / pcs : 1 5x12x 5.5cm837 -* Weight / pcs : 220g1085 +* Package Size / pcs : 14.0 x 8x 5 cm 1086 +* Weight / pcs : 180g 838 838 ))) 839 839 840 840 ((( ... ... @@ -846,5 +846,6 @@ 846 846 847 847 = 9. Support = 848 848 1098 + 849 849 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 850 850 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
- 1657520100595-569.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.1 KB - Content
- image-20220908154949-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.David - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.5 KB - Content
- image-20220908163102-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.David - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.7 KB - Content