Changes for page N95S31B -- NB-IoT Temperature & Humidity Sensor User Manual
Last modified by Mengting Qiu on 2024/04/02 16:44
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Xiaoling1 +XWiki.David - Content
-
... ... @@ -17,6 +17,7 @@ 17 17 18 18 = 1. Introduction = 19 19 20 + 20 20 == 1.1 What is N95S31B NB-IoT Sensor Node == 21 21 22 22 ((( ... ... @@ -55,6 +55,7 @@ 55 55 56 56 == 1.2 Features == 57 57 59 + 58 58 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD 59 59 * Monitor Temperature & Humidity via SHT31 60 60 * AT Commands to change parameters ... ... @@ -66,9 +66,6 @@ 66 66 * Micro SIM card slot for NB-IoT SIM 67 67 * 8500mAh Battery for long term use 68 68 69 - 70 - 71 - 72 72 == 1.3 Specification == 73 73 74 74 ... ... @@ -77,7 +77,6 @@ 77 77 * Supply Voltage: 2.1v ~~ 3.6v 78 78 * Operating Temperature: -40 ~~ 85°C 79 79 80 - 81 81 (% style="color:#037691" %)**NB-IoT Spec:** 82 82 83 83 * - B1 @H-FDD: 2100MHz ... ... @@ -87,7 +87,6 @@ 87 87 * - B20 @H-FDD: 800MHz 88 88 * - B28 @H-FDD: 700MHz 89 89 90 - 91 91 (% style="color:#037691" %)**Battery:** 92 92 93 93 * Li/SOCI2 un-chargeable battery ... ... @@ -96,11 +96,9 @@ 96 96 * Max continuously current: 130mA 97 97 * Max boost current: 2A, 1 second 98 98 99 - 100 - 101 - 102 102 == 1.4 Applications == 103 103 98 + 104 104 * Smart Buildings & Home Automation 105 105 * Logistics and Supply Chain Management 106 106 * Smart Metering ... ... @@ -112,15 +112,20 @@ 112 112 113 113 114 114 115 -== 1.5 Pin Definitions == 116 116 111 +== 1.5 Pin Definitions & Switch == 112 + 113 + 117 117 N95S31B use the mother board from NBSN95 which as below. 118 118 116 + 119 119 [[image:image-20220709144723-1.png]] 120 120 121 121 120 + 122 122 === 1.5.1 Jumper JP2 === 123 123 123 + 124 124 Power on Device when put this jumper. 125 125 126 126 ... ... @@ -127,6 +127,7 @@ 127 127 128 128 === 1.5.2 BOOT MODE / SW1 === 129 129 130 + 130 130 ((( 131 131 1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run. 132 132 ))) ... ... @@ -139,6 +139,7 @@ 139 139 140 140 === 1.5.3 Reset Button === 141 141 143 + 142 142 Press to reboot the device. 143 143 144 144 ... ... @@ -145,16 +145,15 @@ 145 145 146 146 === 1.5.4 LED === 147 147 150 + 148 148 It will flash: 149 149 150 150 1. When boot the device in flash mode 151 151 1. Send an uplink packet 152 152 153 - 154 - 155 - 156 156 = 2. Use N95S31B to communicate with IoT Server = 157 157 158 + 158 158 == 2.1 How it works == 159 159 160 160 ... ... @@ -171,7 +171,7 @@ 171 171 172 172 ))) 173 173 174 -[[image:1657 350248151-650.png]]175 +[[image:1657520100595-569.png]] 175 175 176 176 ((( 177 177 ... ... @@ -187,6 +187,7 @@ 187 187 [[image:image-20220709150546-2.png]] 188 188 189 189 191 + 190 190 === 2.2.1 Test Requirement === 191 191 192 192 ... ... @@ -239,6 +239,7 @@ 239 239 240 240 === 2.2.3 Insert SIM card === 241 241 244 + 242 242 ((( 243 243 Insert the NB-IoT Card get from your provider. 244 244 ))) ... ... @@ -254,14 +254,18 @@ 254 254 255 255 === 2.2.4 Connect USB – TTL to N95S31B to configure it === 256 256 260 + 257 257 ((( 258 258 ((( 259 259 User need to configure N95S31B via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic** (%%)to define where and how-to uplink packets. N95S31B support AT Commands, user can use a USB to TTL adapter to connect to N95S31B and use AT Commands to configure it, as below. 264 + 265 + 260 260 ))) 261 261 ))) 262 262 263 263 [[image:1657351312545-300.png]] 264 264 271 + 265 265 **Connection:** 266 266 267 267 (% style="background-color:yellow" %)USB TTL GND <~-~-~-~-> GND ... ... @@ -285,8 +285,9 @@ 285 285 286 286 [[image:1657329814315-101.png]] 287 287 295 + 288 288 ((( 289 -(% style="color:red" %)Note: the valid AT Commands can be found at: (%%)[[https:~~/~~/www.dr agino.com/downloads/index.php?dir=NB-IoT/N95S31B/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/]]297 +(% style="color:red" %)**Note: the valid AT Commands can be found at: **(%%)**[[https:~~/~~/www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i~~-~~-AyZcQkoua?dl=0>>https://www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i--AyZcQkoua?dl=0]]** 290 290 ))) 291 291 292 292 ... ... @@ -293,9 +293,10 @@ 293 293 294 294 === 2.2.5 Use CoAP protocol to uplink data === 295 295 296 -(% style="color:red" %)Note: if you don't have CoAP server, you can refer this link to set up one: (%%)[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]] 297 297 305 +(% style="color:red" %)**Note: if you don't have CoAP server, you can refer this link to set up one: **(%%)**[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]** 298 298 307 + 299 299 ((( 300 300 **Use below commands:** 301 301 ))) ... ... @@ -343,6 +343,7 @@ 343 343 344 344 === 2.2.7 Use MQTT protocol to uplink data === 345 345 355 + 346 346 N95S31B supports only plain MQTT now it doesn't support TLS and other related encryption. 347 347 348 348 * (% style="color:blue" %)**AT+PRO=3 ** (%%) ~/~/Set to use MQTT protocol to uplink ... ... @@ -358,6 +358,7 @@ 358 358 359 359 [[image:1657352645687-385.png]] 360 360 371 + 361 361 ((( 362 362 To save battery life, N95S31B will establish a subscription before each uplink and close the subscription 3 seconds after uplink successful. Any downlink commands from server will only arrive during the subscription period. 363 363 ))) ... ... @@ -371,6 +371,7 @@ 371 371 372 372 === 2.2.8 Use TCP protocol to uplink data === 373 373 385 + 374 374 This feature is supported since firmware version v110 375 375 376 376 * (% style="color:blue" %)**AT+PRO=4 ** (%%) ~/~/ Set to use TCP protocol to uplink ... ... @@ -385,6 +385,7 @@ 385 385 386 386 === 2.2.9 Change Update Interval === 387 387 400 + 388 388 User can use below command to change the (% style="color:green" %)**uplink interval**. 389 389 390 390 * (% style="color:blue" %)**AT+TDC=600 ** (%%)~/~/ Set Update Interval to 600s ... ... @@ -393,13 +393,16 @@ 393 393 394 394 ))) 395 395 409 +(% style="color:red" %)**NOTE:When the firmware version is v1.2 and later firmware:** 396 396 411 +**By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).** 397 397 413 + 398 398 == 2.3 Uplink Payload == 399 399 400 400 401 401 ((( 402 -N BSN95418 +N95S31B has different working mode for the connections of different type of sensors. This section describes these modes. User can use the AT Command (% style="color:blue" %)**AT+MOD**(%%) to set NBSN95 to different working modes. 403 403 ))) 404 404 405 405 ... ... @@ -408,7 +408,7 @@ 408 408 ))) 409 409 410 410 ((( 411 - (% style="color:blue" %)**AT+CFGMOD=2 ** (%%)~/~/will set the BSN95 to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor.427 + (% style="color:blue" %)**AT+CFGMOD=2 ** (%%)~/~/will set the N95S31B to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor. 412 412 ))) 413 413 414 414 ... ... @@ -431,15 +431,19 @@ 431 431 432 432 (% style="color:red" %) 433 433 1. ((( 434 -All modes share the same Payload Explanation from [[HERE>>||anchor="H2.3A0UplinkPayload"]]. 450 +**All modes share the same Payload Explanation from [[HERE>>||anchor="H2.3A0UplinkPayload"]].** 435 435 ))) 436 436 1. ((( 437 -By default, the device will send an uplink message every 1 hour. 438 -))) 453 +**By default, the device will send an uplink message every 1 hour.** 439 439 440 440 456 + 457 + 458 +))) 459 + 441 441 === 2.3.1 Payload Analyze === 442 442 462 + 443 443 N95S31B uplink payload includes in total 21 bytes 444 444 445 445 ... ... @@ -474,6 +474,8 @@ 474 474 ))) 475 475 476 476 ((( 497 + 498 + 477 477 ((( 478 478 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NB sensor uplink data. 479 479 ))) ... ... @@ -500,12 +500,41 @@ 500 500 ))) 501 501 502 502 ((( 503 - 525 +(% style="color:red" %)**NOTE:When the firmware version is v1.2 and later firmware:** 504 504 ))) 505 505 528 +In this mode, uplink payload includes 91 bytes in total by default. 506 506 530 +Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded. 531 + 532 +|**Size(bytes)**|**8**|2|2|1|1|2|1|2|2|2|4|2|2|4 533 +|**Value**|Device ID|Ver|BAT|Signal Strength|MOD|TemDS18B20|Interrupt|ADC|SHTTEM|SHTHUM|Time stamp |SHTTEM|SHTHUM|Time stamp ..... 534 + 535 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the N95S31B uplink data. 536 + 537 +[[image:image-20220908154949-1.png]] 538 + 539 +The payload is ASCII string, representative same HEX: 540 + 541 +0x(% style="color:red" %)f868411056758782(% style="color:blue" %)000c(% style="color:green" %)0d0f(% style="color:red" %)0c(% style="color:blue" %)01(% style="color:green" %)0000(% style="color:red" %)00**//0030//**(% style="color:blue" %)**//0114//**(% style="color:red" %)**//0231//**(% style="color:green" %)**//63199d3c//**0113023163199d12//**0113023163199c5e**//0112023763199baa//**0112023263199af6**//0111023b631999a7//**0112023b631998f3**//011202426319983f//**01110242631996eb**//(%%) where: 542 + 543 +* (% style="color:red" %) Device ID: f868411056758782 = f868411056758782 544 +* (% style="color:blue" %) Version: 0x000c=120=1.2 545 +* (% style="color:green" %) BAT: 0x0d0f = 3343 mV = 3.343V 546 +* (% style="color:red" %) Singal: 0x0c = 12 547 +* (% style="color:blue" %) Mod: 0x01 = 1 548 +* TemDS18B20: 0x0000= 0 = 0 549 +* (% style="color:green" %)Interrupt: 0x00= 0 550 +* (% style="color:green" %)adc: 0x0030= 48 551 +* SHTTEM: 0x0114= 276 = 27.6 552 +* SHTHUM:0x0231 =561=56.1% 553 +* (% style="color:red" %) Time stamp : 0x6315537b =1662342011 ([[Unix Epoch Time>>url:http://www.epochconverter.com/]]) 554 +* (% style="color:red" %)SHTTEM,SHTHUM,Time stamp : 0113023163199d12 555 +* 8 sets of recorded data: SHTTEM,SHTHUM,Time stamp : //**0113023163199c5e**//,....... 556 + 507 507 === 2.3.2 Device ID === 508 508 559 + 509 509 ((( 510 510 By default, the Device ID equal to the last 6 bytes of IMEI. 511 511 ))) ... ... @@ -524,21 +524,44 @@ 524 524 525 525 ((( 526 526 The Device ID is stored in a none-erase area, Upgrade the firmware or run **AT+FDR** won't erase Device ID. 578 + 579 + 527 527 ))) 528 528 582 +(% style="color:red" %)**NOTE:When the firmware version is v1.2 and later firmware:** 529 529 530 530 585 +By default, the Device ID equal to the last 15 bits of IMEI. 586 + 587 +User can use **AT+DEUI** to set Device ID 588 + 589 +**Example:** 590 + 591 +AT+DEUI=868411056754138 592 + 593 + 531 531 === 2.3.3 Version Info === 532 532 533 533 597 +((( 534 534 These bytes include the hardware and software version. 599 +))) 535 535 601 +((( 536 536 Higher byte: Specify hardware version: always 0x00 for N95S31B 603 +))) 537 537 605 +((( 538 538 Lower byte: Specify the software version: 0x6E=110, means firmware version 110 607 +))) 539 539 609 +((( 610 + 611 +))) 540 540 613 +((( 541 541 For example: 0x00 6E: this device is N95S31B with firmware version 110. 615 +))) 542 542 543 543 ((( 544 544 ... ... @@ -547,6 +547,7 @@ 547 547 548 548 === 2.3.4 Battery Info === 549 549 624 + 550 550 ((( 551 551 Ex1: 0x0B45 = 2885mV 552 552 ))) ... ... @@ -559,6 +559,7 @@ 559 559 560 560 === 2.3.5 Signal Strength === 561 561 637 + 562 562 ((( 563 563 NB-IoT Network signal Strength. 564 564 ))) ... ... @@ -591,6 +591,7 @@ 591 591 592 592 === 2.3.6 Temperature & Humidity === 593 593 670 + 594 594 The device will be able to get the SHT31 temperature and humidity data now and upload to IoT Server. 595 595 596 596 [[image:image-20220709161741-3.png]] ... ... @@ -609,8 +609,9 @@ 609 609 610 610 == 2.4 Downlink Payload == 611 611 612 -By default, NDDS75 prints the downlink payload to console port. 613 613 690 +By default, N95S31B prints the downlink payload to console port. 691 + 614 614 [[image:image-20220709100028-1.png]] 615 615 616 616 ... ... @@ -647,7 +647,7 @@ 647 647 ))) 648 648 649 649 ((( 650 -If payload = 0x04FF, it will reset the DDS75728 +If payload = 0x04FF, it will reset the N95S31B 651 651 ))) 652 652 653 653 ... ... @@ -658,12 +658,59 @@ 658 658 ))) 659 659 660 660 739 +== 2.5 Humidity and Temperature alarm function == 661 661 662 - ==2.5Battery Analysis ==741 +➢ AT Command: 663 663 664 - === 2.5.1 BatteryType===743 +AT+ SHHUM=min,max 665 665 745 +² When min=0, and max≠0, Alarm higher than max 666 666 747 +² When min≠0, and max=0, Alarm lower than min 748 + 749 +² When min≠0 and max≠0, Alarm higher than max or lower than min 750 + 751 +Example: 752 + 753 +AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50. 754 + 755 + 756 +AT+ SHTEMP=min,max 757 + 758 +² When min=0, and max≠0, Alarm higher than max 759 + 760 +² When min≠0, and max=0, Alarm lower than min 761 + 762 +² When min≠0 and max≠0, Alarm higher than max or lower than min 763 + 764 +Example: 765 + 766 +AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20. 767 + 768 +== 2.6 Set the number of data to be uploaded and the recording time == 769 + 770 +➢ AT Command: 771 + 772 +AT+TR=900 ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds) 773 + 774 +AT+NOUD=8 ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded. 775 + 776 +== 2.7 Read or Clear cached data == 777 + 778 +➢ AT Command: 779 + 780 +AT+CDP ~/~/ Read cached data 781 + 782 +[[image:image-20220908163102-2.png]] 783 + 784 +AT+CDP=0 ~/~/ Clear cached data 785 + 786 +== 2.8 Battery Analysis == 787 + 788 + 789 +=== 2.8.1 Battery Type === 790 + 791 + 667 667 ((( 668 668 The N95S31B battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter. 669 669 ))) ... ... @@ -686,10 +686,11 @@ 686 686 687 687 688 688 689 -=== 2. 5.2 Power consumption Analyze ===814 +=== 2.8.2 Power consumption Analyze === 690 690 816 + 691 691 ((( 692 -The file **DRAGINO_N95S31B-Power-Analyzer.pdf** from [[https:~~/~~/www.dr agino.com/downloads/index.php?dir=NB-IoT/N95S31B/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/]]818 +The file **DRAGINO_N95S31B-Power-Analyzer.pdf** from [[https:~~/~~/www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i~~-~~-AyZcQkoua?dl=0>>https://www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i--AyZcQkoua?dl=0]] describes a detail measurement to analyze the power consumption in different case. User can use it for design guideline for their project. 693 693 ))) 694 694 695 695 ((( ... ... @@ -697,8 +697,9 @@ 697 697 ))) 698 698 699 699 700 -=== 2. 5.3 Battery Note ===826 +=== 2.8.3 Battery Note === 701 701 828 + 702 702 ((( 703 703 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to uplink data, then the battery life may be decreased. 704 704 ))) ... ... @@ -705,7 +705,7 @@ 705 705 706 706 707 707 708 -=== 2. 5.4 Replace the battery ===835 +=== 2.8.4 Replace the battery === 709 709 710 710 711 711 ((( ... ... @@ -721,6 +721,7 @@ 721 721 722 722 = 3. Access NB-IoT Module = 723 723 851 + 724 724 ((( 725 725 Users can directly access the AT command set of the NB-IoT module. 726 726 ))) ... ... @@ -727,6 +727,8 @@ 727 727 728 728 ((( 729 729 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 858 + 859 + 730 730 ))) 731 731 732 732 [[image:1657333200519-600.png]] ... ... @@ -735,11 +735,13 @@ 735 735 736 736 = 4. Using the AT Commands = 737 737 868 + 738 738 == 4.1 Access AT Commands == 739 739 740 -See NBSN95 AT Command in this link for detail: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN95/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN95/]] 741 741 872 +See NBSN95 AT Command in this link for detail: [[https:~~/~~/www.dropbox.com/sh/jao1xt9kw5r3yq4/AAAMpJkZzExF2JLbRWxGoQ9Na?dl=0>>https://www.dropbox.com/sh/jao1xt9kw5r3yq4/AAAMpJkZzExF2JLbRWxGoQ9Na?dl=0]] 742 742 874 + 743 743 AT+<CMD>? : Help on <CMD> 744 744 745 745 AT+<CMD> : Run <CMD> ... ... @@ -779,7 +779,24 @@ 779 779 780 780 AT+SERVADDR : Server Address 781 781 914 +AT+TR : Get or Set record time 782 782 916 +AT+APN : Get or set the APN 917 + 918 +AT+FBAND : Get or Set whether to automatically modify the frequency band 919 + 920 +AT+DNSCFG : Get or Set DNS Server 921 + 922 +AT+GETSENSORVALUE : Returns the current sensor measurement 923 + 924 +AT+NOUD : Get or Set the number of data to be uploaded 925 + 926 +AT+CDP : Read or Clear cached data 927 + 928 +AT+SHTEMP: Get or Set alarm of temp 929 + 930 +AT+SHHUM: Get or Set alarm of moisture 931 + 783 783 (% style="color:#037691" %)**COAP Management** 784 784 785 785 AT+URI : Resource parameters ... ... @@ -813,6 +813,7 @@ 813 813 814 814 = 5. FAQ = 815 815 965 + 816 816 == 5.1 How to Upgrade Firmware == 817 817 818 818 ... ... @@ -827,13 +827,16 @@ 827 827 ((( 828 828 829 829 830 -(% style="color:red" %)Notice, N95S31B and LSN50v2 share the same mother board. They use the same connection and method to update. 980 +((( 981 +(% style="color:red" %)**Notice, N95S31B and LSN50v2 share the same mother board. They use the same connection and method to update.** 831 831 ))) 983 +))) 832 832 833 833 834 834 835 835 = 6. Trouble Shooting = 836 836 989 + 837 837 == 6.1 Connection problem when uploading firmware == 838 838 839 839 ... ... @@ -849,6 +849,7 @@ 849 849 850 850 == 6.2 AT Command input doesn't work == 851 851 1005 + 852 852 ((( 853 853 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string. 854 854 ... ... @@ -898,5 +898,8 @@ 898 898 899 899 = 9. Support = 900 900 1055 + 901 901 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule. 902 902 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]] 1058 + 1059 +
- 1657520100595-569.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Xiaoling - Size
-
... ... @@ -1,0 +1,1 @@ 1 +126.1 KB - Content
- image-20220908154949-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.David - Size
-
... ... @@ -1,0 +1,1 @@ 1 +58.5 KB - Content
- image-20220908163102-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.David - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.7 KB - Content