... ... @@ -9,6 +9,7 @@
9 9  
10 10  **Table of Contents:**
11 11  
12 +{{toc/}}
12 12  
13 13  
14 14  
... ... @@ -16,21 +16,35 @@
16 16  
17 17  = 1.  Introduction =
18 18  
20 +
19 19  == 1.1 ​ What is N95S31B NB-IoT Sensor Node ==
20 20  
21 21  (((
22 22  
23 23  
26 +(((
24 24  The Dragino N95S31B is a (% style="color:blue" %)**NB-IoT Temperature and Humidity Sensor**(%%) for Internet of Things solution. It is used to measure the (% style="color:blue" %)**surrounding environment temperature and relative air humidity precisely**(%%), and then upload to IoT server via NB-IoT network*.
28 +)))
25 25  
30 +(((
26 26  The temperature & humidity sensor used in N95S31B is SHT31, which is fully calibrated, linearized, and temperature compensated digital output from Sensirion, it provides a strong reliability and long-term stability. The SHT31 is fixed in a (% style="color:blue" %)**waterproof anti-condensation casing **(%%)for long term use.
32 +)))
27 27  
34 +(((
28 28  N95S31B supports different uplink methods include (% style="color:blue" %)**TCP, MQTT, UDP and CoAP**(%%) for different application requirement.
36 +)))
29 29  
38 +(((
30 30  N95S31B is powered by(% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to several years. (Real-world battery life depends on the use environment, update period. Please check related Power Analyze report).
40 +)))
31 31  
42 +(((
43 +
44 +)))
32 32  
46 +(((
33 33  ~* make sure you have NB-IoT coverage locally.
48 +)))
34 34  
35 35  
36 36  )))
... ... @@ -41,6 +41,7 @@
41 41  
42 42  == 1.2 ​ Features ==
43 43  
59 +
44 44  * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD
45 45  * Monitor Temperature & Humidity via SHT31
46 46  * AT Commands to change parameters
... ... @@ -53,8 +53,6 @@
53 53  * 8500mAh Battery for long term use
54 54  
55 55  
56 -
57 -
58 58  == 1.3  Specification ==
59 59  
60 60  
... ... @@ -74,7 +74,6 @@
74 74  
75 75  (% style="color:#037691" %)**Battery:**
76 76  
77 -
78 78  * Li/SOCI2 un-chargeable battery
79 79  * Capacity: 8500mAh
80 80  * Self Discharge: <1% / Year @ 25°C
... ... @@ -82,10 +82,9 @@
82 82  * Max boost current: 2A, 1 second
83 83  
84 84  
85 -
86 -
87 87  == ​1.4  Applications ==
88 88  
100 +
89 89  * Smart Buildings & Home Automation
90 90  * Logistics and Supply Chain Management
91 91  * Smart Metering
... ... @@ -97,15 +97,21 @@
97 97  ​
98 98  
99 99  
100 -== 1.5  Pin Definitions ==
101 101  
113 +
114 +== 1.5  Pin Definitions & Switch ==
115 +
116 +
102 102  N95S31B use the mother board from NBSN95 which as below.
103 103  
119 +
104 104  [[image:image-20220709144723-1.png]]
105 105  
106 106  
123 +
107 107  === 1.5.1 Jumper JP2 ===
108 108  
126 +
109 109  Power on Device when put this jumper.
110 110  
111 111  
... ... @@ -112,14 +112,20 @@
112 112  
113 113  === 1.5.2 BOOT MODE / SW1 ===
114 114  
133 +
134 +(((
115 115  1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run.
136 +)))
116 116  
138 +(((
117 117  2) Flash: work mode, device starts to work and send out console output for further debug
140 +)))
118 118  
119 119  
120 120  
121 121  === 1.5.3 Reset Button ===
122 122  
146 +
123 123  Press to reboot the device.
124 124  
125 125  
... ... @@ -126,6 +126,7 @@
126 126  
127 127  === 1.5.4 LED ===
128 128  
153 +
129 129  It will flash:
130 130  
131 131  1. When boot the device in flash mode
... ... @@ -134,6 +134,7 @@
134 134  
135 135  = 2.  Use N95S31B to communicate with IoT Server =
136 136  
162 +
137 137  == 2.1  How it works ==
138 138  
139 139  
... ... @@ -150,7 +150,7 @@
150 150  
151 151  )))
152 152  
153 -[[image:1657350248151-650.png]]
179 +[[image:1657520100595-569.png]]
154 154  
155 155  (((
156 156  
... ... @@ -166,26 +166,49 @@
166 166  [[image:image-20220709150546-2.png]]
167 167  
168 168  
195 +
169 169  === 2.2.1 Test Requirement ===
170 170  
171 171  
199 +(((
172 172  To use N95S31B in your city, make sure meet below requirements:
201 +)))
173 173  
174 -* Your local operator has already distributed a NB-IoT Network there.
175 -* The local NB-IoT network used the band that N95S31B supports.
176 -* Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
203 +* (((
204 +Your local operator has already distributed a NB-IoT Network there.
205 +)))
206 +* (((
207 +The local NB-IoT network used the band that N95S31B supports.
208 +)))
209 +* (((
210 +Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
211 +)))
177 177  
213 +(((
178 178  Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.
215 +)))
179 179  
217 +(((
180 180  N95S31B supports different communication protocol such as :
219 +)))
181 181  
182 182  (((
183 -* CoAP  ((% style="color:red" %)120.24.4.116:5683(%%))
184 -* raw UDP  ((% style="color:red" %)120.24.4.116:5601(%%))
185 -* MQTT  ((% style="color:red" %)120.24.4.116:1883(%%))
186 -* TCP  ((% style="color:red" %)120.24.4.116:5600(%%))
222 +* (((
223 +CoAP  ((% style="color:red" %)120.24.4.116:5683(%%))
224 +)))
225 +* (((
226 +raw UDP  ((% style="color:red" %)120.24.4.116:5601(%%))
227 +)))
228 +* (((
229 +MQTT  ((% style="color:red" %)120.24.4.116:1883(%%))
230 +)))
231 +* (((
232 +TCP  ((% style="color:red" %)120.24.4.116:5600(%%))
233 +)))
187 187  
235 +(((
188 188  We will show how to use with each protocol. The IP addresses above are our test server. User need to change to point their corresponding server.
237 +)))
189 189  
190 190  
191 191  )))
... ... @@ -196,6 +196,7 @@
196 196  
197 197  === 2.2.3  Insert SIM card ===
198 198  
248 +
199 199  (((
200 200  Insert the NB-IoT Card get from your provider.
201 201  )))
... ... @@ -211,14 +211,18 @@
211 211  
212 212  === 2.2.4  Connect USB – TTL to N95S31B to configure it ===
213 213  
264 +
214 214  (((
215 215  (((
216 216  User need to configure N95S31B via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic** (%%)to define where and how-to uplink packets. N95S31B support AT Commands, user can use a USB to TTL adapter to connect to N95S31B and use AT Commands to configure it, as below.
268 +
269 +
217 217  )))
218 218  )))
219 219  
220 220  [[image:1657351312545-300.png]]
221 221  
275 +
222 222  **Connection:**
223 223  
224 224   (% style="background-color:yellow" %)USB TTL GND <~-~-~-~-> GND
... ... @@ -242,8 +242,9 @@
242 242  
243 243  [[image:1657329814315-101.png]]
244 244  
299 +
245 245  (((
246 -(% style="color:red" %)Note: the valid AT Commands can be found at:  (%%)[[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/]]
301 +(% style="color:red" %)**Note: the valid AT Commands can be found at:  **(%%)**[[https:~~/~~/www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i~~-~~-AyZcQkoua?dl=0>>https://www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i--AyZcQkoua?dl=0]]**
247 247  )))
248 248  
249 249  
... ... @@ -250,9 +250,10 @@
250 250  
251 251  === 2.2.5  Use CoAP protocol to uplink data ===
252 252  
253 -(% style="color:red" %)Note: if you don't have CoAP server, you can refer this link to set up one: (%%)[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
254 254  
309 +(% style="color:red" %)**Note: if you don't have CoAP server, you can refer this link to set up one: **(%%)**[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]**
255 255  
311 +
256 256  (((
257 257  **Use below commands:**
258 258  )))
... ... @@ -300,6 +300,7 @@
300 300  
301 301  === 2.2.7  Use MQTT protocol to uplink data ===
302 302  
359 +
303 303  N95S31B supports only plain MQTT now it doesn't support TLS and other related encryption.
304 304  
305 305  * (% style="color:blue" %)**AT+PRO=3   ** (%%) ~/~/Set to use MQTT protocol to uplink
... ... @@ -315,6 +315,7 @@
315 315  
316 316  [[image:1657352645687-385.png]]
317 317  
375 +
318 318  (((
319 319  To save battery life, N95S31B will establish a subscription before each uplink and close the subscription 3 seconds after uplink successful. Any downlink commands from server will only arrive during the subscription period.
320 320  )))
... ... @@ -328,6 +328,7 @@
328 328  
329 329  === 2.2.8  Use TCP protocol to uplink data ===
330 330  
389 +
331 331  This feature is supported since firmware version v110
332 332  
333 333  * (% style="color:blue" %)**AT+PRO=4   ** (%%) ~/~/ Set to use TCP protocol to uplink
... ... @@ -342,6 +342,7 @@
342 342  
343 343  === 2.2.9  Change Update Interval ===
344 344  
404 +
345 345  User can use below command to change the (% style="color:green" %)**uplink interval**.
346 346  
347 347  * (% style="color:blue" %)**AT+TDC=600      ** (%%)~/~/ Set Update Interval to 600s
... ... @@ -350,58 +350,104 @@
350 350  
351 351  )))
352 352  
413 +(((
414 +(% style="color:red" %)**NOTE: Since firmware version is v1.2:**
415 +)))
353 353  
417 +(((
418 +(% style="color:red" %)**By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).**
419 +)))
354 354  
421 +
422 +
355 355  == 2.3  Uplink Payload ==
356 356  
357 357  
358 -NBSN95 has different working mode for the connections of different type of sensors. This section describes these modes. User can use the AT Command (% style="color:blue" %)**AT+MOD**(%%) to set NBSN95 to different working modes.
426 +(((
427 +N95S31B has different working modes for the connections of different types of sensors. This section describes these modes. User can use the AT Command (% style="color:blue" %)**AT+MOD**(%%) to set NBSN95 to different working modes.
428 +)))
359 359  
360 360  
431 +(((
361 361  For example:
433 +)))
362 362  
363 - (% style="color:blue" %)**AT+CFGMOD=2 ** (%%)~/~/will set the NBSN95 to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor.
435 +(((
436 + (% style="color:blue" %)**AT+CFGMOD=2 ** (%%)~/~/will set the N95S31B to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor.
437 +)))
364 364  
365 365  
440 +(((
366 366  The uplink payloads are composed in  ASCII String. For example:
442 +)))
367 367  
444 +(((
368 368  0a cd 00 ed 0a cc 00 00 ef 02 d2 1d (total 24 ASCII Chars) . Representative the actually payload:
446 +)))
369 369  
448 +(((
370 370  0x 0a cd 00 ed 0a cc 00 00 ef 02 d2 1d Total 12 bytes
450 +)))
371 371  
372 372  
453 +(((
373 373  (% style="color:red" %)**NOTE:**
455 +)))
374 374  
375 375  (% style="color:red" %)
376 -1. All modes share the same Payload Explanation from [[HERE>>path:#Payload_Explain]].
377 -1. By default, the device will send an uplink message every 1 hour.
458 +1. (((
459 +**All modes share the same Payload Explanation from [[HERE>>||anchor="H2.3A0UplinkPayload"]].**
460 +)))
461 +1. (((
462 +**By default, the device will send an uplink message every 1 hour.**
378 378  
379 379  
380 380  
466 +
467 +)))
468 +
381 381  === 2.3.1  Payload Analyze ===
382 382  
471 +
472 +==== 2.3.1.1  Before Firmware v1.2 ====
473 +
474 +
383 383  N95S31B uplink payload includes in total 21 bytes
384 384  
385 385  
386 -(% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:440px" %)
478 +(% border="2" cellspacing="10" style="background-color:#ffffcc; color:green; width:760px" %)
387 387  |=(% style="width: 60px;" %)(((
388 388  **Size(bytes)**
389 -)))|=(% style="width: 60px;" %)**6**|=(% style="width: 35px;" %)2|=(% style="width: 35px;" %)**2**|=(% style="width: 80px;" %)**1**|=(% style="width: 80px;" %) |=(% style="width: 99px;" %) |=(% style="width: 77px;" %)**2**|=(% style="width: 60px;" %)**1**
390 -|(% style="width:97px" %)**Value**|(% style="width:83px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:41px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:123px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:123px" %)MOD 0X01|(% style="width:99px" %)(((
481 +)))|=(% style="width: 65px;" %)**6**|=(% style="width: 50px;" %)2|=(% style="width: 25px;" %)**2**|=(% style="width: 75px;" %)**1**|=(% style="width: 59px;" %)1|=(% style="width: 174px;" %)5|=(% style="width: 106px;" %)**2**|=(% style="width: 85px;" %)**2**
482 +|(% style="width:97px" %)**Value**|(% style="width:65px" %)[[Device ID>>||anchor="H2.3.2A0DeviceID"]]|(% style="width:50px" %)[[Ver>>||anchor="H2.3.3A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.3.4A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.3.5A0SignalStrength"]]|(% style="width:59px" %)MOD 0X01|(% style="width:174px" %)(((
483 +(((
391 391  Reserve/ Same as NBSN95 CFGMOD=1
485 +)))
392 392  
487 +(((
393 393  No function here.
394 -)))|(% style="width:77px" %)(((
395 -[[Temperature >>||anchor="H2.4.5A0Distance"]]
489 +)))
490 +)))|(% style="width:106px" %)(((
491 +(((
492 +[[Temperature >>||anchor="H2.3.6A0Temperature26Humidity"]]
493 +)))
396 396  
495 +(((
397 397  By SHT31
398 -)))|(% style="width:80px" %)(((
399 -[[Humidity>>||anchor="H2.4.6A0DigitalInterrupt"]]
497 +)))
498 +)))|(% style="width:85px" %)(((
499 +(((
500 +[[Humidity>>||anchor="H2.3.6A0Temperature26Humidity"]]
501 +)))
400 400  
503 +(((
401 401  By SHT31
402 402  )))
506 +)))
403 403  
404 404  (((
509 +
510 +
405 405  (((
406 406  If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NB sensor uplink data.
407 407  )))
... ... @@ -413,27 +413,83 @@
413 413  
414 414  The payload is ASCII string, representative same HEX: 0x724031607457006e0ccd1b0100dc000ccc00e10186 where:
415 415  
416 -* Device ID: 0x724031607457 = 724031607457
417 -* Version: 0x006e=110=1.1.0
522 +* Device ID:  0x724031607457 = 724031607457
418 418  
419 -* BAT: 0x0ccd = 3277 mV = 3.277V
420 -* Signal: 0x1b = 27
421 -* Model: 0x01 = 1
524 +* Version:  0x006e=110=1.1.0
525 +
526 +* BAT:  0x0ccd = 3277 mV = 3.277V
527 +
528 +* Signal:  0x1b = 27
529 +
530 +* Model:  0x01 = 1
531 +
422 422  * 0x00dc000ccc= reserve, ignore in N95S31B
423 -* Temperature by SHT31: 0x00e1 = 225 = 22.5 °C
424 -* Humidity by SHT31: 0x0186 = 390 = 39.0 %rh
425 425  
534 +* Temperature by SHT31:  0x00e1 = 225 = 22.5 °C
535 +
536 +* Humidity by SHT31:  0x0186 = 390 = 39.0 %rh
537 +
426 426  (((
427 427  
428 -)))
429 429  
430 -(((
541 +
431 431  
432 432  )))
433 433  
545 +==== 2.3.1.2 Since Firmware v1.2 ====
434 434  
547 +
548 +In this mode, uplink payload includes 91 bytes in total by default.
549 +
550 +Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded.
551 +
552 +
553 +(% border="2" style="background-color:#ffffcc; color:green; width:1234px" %)
554 +|(% style="width:95px" %)**Size(bytes)**|(% style="width:82px" %)**8**|(% style="width:43px" %)**2**|(% style="width:47px" %)**2**|(% style="width:124px" %)**1**|(% style="width:56px" %)**1**|(% style="width:109px" %)**2**|(% style="width:80px" %)**1**|(% style="width:51px" %)**2**|(% style="width:79px" %)**2**|(% style="width:84px" %)**2**|(% style="width:100px" %)**4**|(% style="width:76px" %)**2**|(% style="width:81px" %)**2**|(% style="width:121px" %)**4**
555 +|(% style="width:95px" %)**Value**|(% style="width:82px" %)Device ID|(% style="width:43px" %)Ver|(% style="width:47px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:56px" %)MOD|(% style="width:109px" %)TemDS18B20|(% style="width:80px" %)Interrupt|(% style="width:51px" %)ADC|(% style="width:79px" %)SHTTEM|(% style="width:84px" %)SHTHUM|(% style="width:100px" %)Time stamp |(% style="width:76px" %)SHTTEM|(% style="width:81px" %)SHTHUM|(% style="width:121px" %)Time stamp .....
556 +
557 +If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the N95S31B uplink data.
558 +
559 +
560 +[[image:image-20220908154949-1.png]]
561 +
562 +
563 +The payload is ASCII string, representative same HEX:
564 +
565 +0x(% style="color:red" %)f868411056758782(% style="color:blue" %)000c(% style="color:green" %)0d0f(% style="color:red" %)0c(% style="color:blue" %)01(% style="color:green" %)0000(% style="color:red" %)00**//0030//**(% style="color:blue" %)**//0114//**(% style="color:red" %)**//0231//**(% style="color:green" %)**//63199d3c//**0113023163199d12//**0113023163199c5e**//0112023763199baa//**0112023263199af6**//0111023b631999a7//**0112023b631998f3**//011202426319983f//**01110242631996eb**//(%%) where:
566 +
567 +* (% style="color:red" %)Device ID: f868411056758782 = f868411056758782
568 +
569 +* (% style="color:blue" %)Version: 0x000c=120=1.2
570 +
571 +* (% style="color:green" %)BAT: 0x0d0f = 3343 mV = 3.343V
572 +
573 +* (% style="color:red" %)Singal: 0x0c = 12
574 +
575 +* (% style="color:blue" %)Mod: 0x01 = 1
576 +
577 +* TemDS18B20: 0x0000= 0 = 0
578 +
579 +* (% style="color:green" %)Interrupt: 0x00= 0
580 +
581 +* (% style="color:green" %)adc: 0x0030= 48
582 +
583 +* SHTTEM: 0x0114= 276 = 27.6
584 +
585 +* SHTHUM:0x0231 =561=56.1%
586 +
587 +* (% style="color:red" %)Time stamp : 0x6315537b =1662342011  ([[Unix Epoch Time>>url:http://www.epochconverter.com/]])
588 +
589 +* (% style="color:red" %)SHTTEM,SHTHUM,Time stamp : 0113023163199d12
590 +
591 +* 8 sets of recorded data: SHTTEM,SHTHUM,Time stamp : //**0113023163199c5e**//,.......
592 +
593 +
594 +
595 +
435 435  === 2.3.2  Device ID ===
436 436  
598 +
437 437  (((
438 438  By default, the Device ID equal to the last 6 bytes of IMEI.
439 439  )))
... ... @@ -452,21 +452,44 @@
452 452  
453 453  (((
454 454  The Device ID is stored in a none-erase area, Upgrade the firmware or run **AT+FDR** won't erase Device ID.
617 +
618 +
455 455  )))
456 456  
621 +(% style="color:red" %)**NOTE:When the firmware version is v1.2 and later firmware:**
457 457  
458 458  
624 +By default, the Device ID equal to the last 15 bits of IMEI.
625 +
626 +User can use **AT+DEUI** to set Device ID
627 +
628 +**Example:**
629 +
630 +AT+DEUI=868411056754138
631 +
632 +
459 459  === 2.3.3  Version Info ===
460 460  
461 461  
636 +(((
462 462  These bytes include the hardware and software version.
638 +)))
463 463  
640 +(((
464 464  Higher byte: Specify hardware version: always 0x00 for N95S31B
642 +)))
465 465  
644 +(((
466 466  Lower byte: Specify the software version: 0x6E=110, means firmware version 110
646 +)))
467 467  
648 +(((
649 +
650 +)))
468 468  
652 +(((
469 469  For example: 0x00 6E: this device is N95S31B with firmware version 110.
654 +)))
470 470  
471 471  (((
472 472  
... ... @@ -475,6 +475,7 @@
475 475  
476 476  === 2.3.4  Battery Info ===
477 477  
663 +
478 478  (((
479 479  Ex1: 0x0B45 = 2885mV
480 480  )))
... ... @@ -487,6 +487,7 @@
487 487  
488 488  === 2.3.5  Signal Strength ===
489 489  
676 +
490 490  (((
491 491  NB-IoT Network signal Strength.
492 492  )))
... ... @@ -519,6 +519,7 @@
519 519  
520 520  === 2.3.6  Temperature & Humidity ===
521 521  
709 +
522 522  The device will be able to get the SHT31 temperature and humidity data now and upload to IoT Server.
523 523  
524 524  [[image:image-20220709161741-3.png]]
... ... @@ -535,10 +535,11 @@
535 535  
536 536  
537 537  
538 -== 2.5  Downlink Payload ==
726 +== 2.4  Downlink Payload ==
539 539  
540 -By default, NDDS75 prints the downlink payload to console port.
541 541  
729 +By default, N95S31B prints the downlink payload to console port.
730 +
542 542  [[image:image-20220709100028-1.png]]
543 543  
544 544  
... ... @@ -575,7 +575,7 @@
575 575  )))
576 576  
577 577  (((
578 -If payload = 0x04FF, it will reset the NDDS75
767 +If payload = 0x04FF, it will reset the N95S31B
579 579  )))
580 580  
581 581  
... ... @@ -586,12 +586,59 @@
586 586  )))
587 587  
588 588  
778 +== 2.5 Humidity and Temperature alarm function ==
589 589  
590 -== 2.5  ​Battery Analysis ==
780 + AT Command:
591 591  
592 -=== 2.5.1  ​Battery Type ===
782 +AT+ SHHUM=min,max
593 593  
784 +² When min=0, and max≠0, Alarm higher than max
594 594  
786 +² When min≠0, and max=0, Alarm lower than min
787 +
788 +² When min≠0 and max≠0, Alarm higher than max or lower than min
789 +
790 +Example:
791 +
792 +AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50.
793 +
794 +
795 +AT+ SHTEMP=min,max
796 +
797 +² When min=0, and max≠0, Alarm higher than max
798 +
799 +² When min≠0, and max=0, Alarm lower than min
800 +
801 +² When min≠0 and max≠0, Alarm higher than max or lower than min
802 +
803 +Example:
804 +
805 +AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20.
806 +
807 +== 2.6 Set the number of data to be uploaded and the recording time ==
808 +
809 +➢ AT Command:
810 +
811 +AT+TR=900  ~/~/The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
812 +
813 +AT+NOUD=8  ~/~/The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
814 +
815 +== 2.7 Read or Clear cached data ==
816 +
817 +➢ AT Command:
818 +
819 +AT+CDP ~/~/ Read cached data
820 +
821 +[[image:image-20220908163102-2.png]]
822 +
823 +AT+CDP=0 ~/~/ Clear cached data
824 +
825 +== 2.8  ​Battery Analysis ==
826 +
827 +
828 +=== 2.8.1  ​Battery Type ===
829 +
830 +
595 595  (((
596 596  The N95S31B battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
597 597  )))
... ... @@ -614,10 +614,11 @@
614 614  
615 615  
616 616  
617 -=== 2.5.2  Power consumption Analyze ===
853 +=== 2.8.2  Power consumption Analyze ===
618 618  
855 +
619 619  (((
620 -The file **DRAGINO_N95S31B-Power-Analyzer.pdf** from [[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/N95S31B/]] describes a detail measurement to analyze the power consumption in different case. User can use it for design guideline for their project.
857 +The file **DRAGINO_N95S31B-Power-Analyzer.pdf** from [[https:~~/~~/www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i~~-~~-AyZcQkoua?dl=0>>https://www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i--AyZcQkoua?dl=0]] describes a detail measurement to analyze the power consumption in different case. User can use it for design guideline for their project.
621 621  )))
622 622  
623 623  (((
... ... @@ -625,8 +625,9 @@
625 625  )))
626 626  
627 627  
628 -=== 2.5.3  ​Battery Note ===
865 +=== 2.8.3  ​Battery Note ===
629 629  
867 +
630 630  (((
631 631  The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to uplink data, then the battery life may be decreased.
632 632  )))
... ... @@ -633,7 +633,7 @@
633 633  
634 634  
635 635  
636 -=== 2.5.4  Replace the battery ===
874 +=== 2.8.4  Replace the battery ===
637 637  
638 638  
639 639  (((
... ... @@ -649,6 +649,7 @@
649 649  
650 650  = 3. ​ Access NB-IoT Module =
651 651  
890 +
652 652  (((
653 653  Users can directly access the AT command set of the NB-IoT module.
654 654  )))
... ... @@ -655,6 +655,8 @@
655 655  
656 656  (((
657 657  The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
897 +
898 +
658 658  )))
659 659  
660 660  [[image:1657333200519-600.png]]
... ... @@ -663,11 +663,13 @@
663 663  
664 664  = 4.  Using the AT Commands =
665 665  
907 +
666 666  == 4.1  Access AT Commands ==
667 667  
668 -See NBSN95 AT Command in this link for detail:  [[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN95/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN95/]]
669 669  
911 +See NBSN95 AT Command in this link for detail:  [[https:~~/~~/www.dropbox.com/sh/jao1xt9kw5r3yq4/AAAMpJkZzExF2JLbRWxGoQ9Na?dl=0>>https://www.dropbox.com/sh/jao1xt9kw5r3yq4/AAAMpJkZzExF2JLbRWxGoQ9Na?dl=0]]
670 670  
913 +
671 671  AT+<CMD>?  : Help on <CMD>
672 672  
673 673  AT+<CMD>         : Run <CMD>
... ... @@ -707,7 +707,24 @@
707 707  
708 708  AT+SERVADDR  : Server Address
709 709  
953 +AT+TR      : Get or Set record time
710 710  
955 +AT+APN     : Get or set the APN
956 +
957 +AT+FBAND   : Get or Set whether to automatically modify the frequency band
958 +
959 +AT+DNSCFG  : Get or Set DNS Server
960 +
961 +AT+GETSENSORVALUE   : Returns the current sensor measurement
962 +
963 +AT+NOUD      : Get or Set the number of data to be uploaded
964 +
965 +AT+CDP     : Read or Clear cached data
966 +
967 +AT+SHTEMP: Get or Set alarm of temp
968 +
969 +AT+SHHUM: Get or Set alarm of moisture
970 +
711 711  (% style="color:#037691" %)**COAP Management**      
712 712  
713 713  AT+URI            : Resource parameters
... ... @@ -741,6 +741,7 @@
741 741  
742 742  = ​5.  FAQ =
743 743  
1004 +
744 744  == 5.1 ​ How to Upgrade Firmware ==
745 745  
746 746  
... ... @@ -755,13 +755,16 @@
755 755  (((
756 756  
757 757  
758 -(% style="color:red" %)Notice, N95S31B and LSN50v2 share the same mother board. They use the same connection and method to update.
1019 +(((
1020 +(% style="color:red" %)**Notice, N95S31B and LSN50v2 share the same mother board. They use the same connection and method to update.**
759 759  )))
1022 +)))
760 760  
761 761  
762 762  
763 763  = 6.  Trouble Shooting =
764 764  
1028 +
765 765  == 6.1  ​Connection problem when uploading firmware ==
766 766  
767 767  
... ... @@ -777,6 +777,7 @@
777 777  
778 778  == 6.2  AT Command input doesn't work ==
779 779  
1044 +
780 780  (((
781 781  In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
782 782  
... ... @@ -811,11 +811,10 @@
811 811  
812 812  (% style="color:#037691" %)**Dimension and weight**:
813 813  
814 -
815 815  * Device Size: 13.0 x 5 x 4.5 cm
816 816  * Device Weight: 150g
817 -* Package Size / pcs : 15 x 12x 5.5 cm
818 -* Weight / pcs : 220g
1081 +* Package Size / pcs : 14.0 x 8x 5 cm
1082 +* Weight / pcs : 180g
819 819  )))
820 820  
821 821  (((
... ... @@ -827,5 +827,6 @@
827 827  
828 828  = 9.  Support =
829 829  
1094 +
830 830  * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
831 831  * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1657520100595-569.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Xiaoling
Size
... ... @@ -1,0 +1,1 @@
1 +126.1 KB
Content
image-20220908154949-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.David
Size
... ... @@ -1,0 +1,1 @@
1 +58.5 KB
Content
image-20220908163102-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.David
Size
... ... @@ -1,0 +1,1 @@
1 +29.7 KB
Content
Copyright ©2010-2022 Dragino Technology Co., LTD. All rights reserved
Dragino Wiki v2.0