Version 92.2 by Xiaoling on 2022/07/09 10:02

Show last authors
1 (% style="text-align:center" %)
2 [[image:image-20220709085040-1.png||height="542" width="524"]]
3
4
5
6
7
8 **Table of Contents:**
9
10
11
12
13
14
15
16 = 1.  Introduction =
17
18 == 1.1 ​ What is NDDS75 Distance Detection Sensor ==
19
20 (((
21
22
23 (((
24 The Dragino NDDS75 is a (% style="color:blue" %)**NB-IoT Distance Detection Sensor**(%%) for Internet of Things solution. It is designed to measure the distance between the sensor and a flat object. The distance detection sensor is a module that uses ultrasonic sensing technology for distance measurement, and temperature compensation is performed internally to improve the reliability of data.
25 \\The NDDS75 can be applied to scenarios such as horizontal distance measurement, liquid level measurement, parking management system, object proximity and presence detection, intelligent trash can management system, robot obstacle avoidance, automatic control, sewer, bottom water level monitoring, etc. It detects the distance between the measured object and the sensor, and uploads the value via wireless to IoT Server via NB-IoT Network.
26 \\NarrowBand-Internet of Things (NB-IoT) is a standards-based low power wide area (LPWA) technology developed to enable a wide range of new IoT devices and services. NB-IoT significantly improves the power consumption of user devices, system capacity and spectrum efficiency, especially in deep coverage.
27 \\NDDS75 supports different uplink methods include (% style="color:blue" %)**TCP, MQTT, UDP and CoAP** (%%)for different application requirement.
28 \\NDDS75 is powered by (% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to 5 years. (Actually Battery life depends on the use environment, update period & uplink method)
29 \\To use NDDS75, user needs to check if there is NB-IoT coverage in local area and with the bands NDDS75 supports. If the local operate support it, user needs to get a NB-IoT SIM card from local operator and install NDDS75 to get NB-IoT network connection.
30 )))
31
32
33 )))
34
35 [[image:1654503236291-817.png]]
36
37
38 [[image:1657327959271-447.png]]
39
40
41
42 == 1.2 ​ Features ==
43
44
45 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD
46 * Ultra low power consumption
47 * Distance Detection by Ultrasonic technology
48 * Flat object range 280mm - 7500mm
49 * Accuracy: ±(1cm+S*0.3%) (S: Distance)
50 * Cable Length: 25cm
51 * AT Commands to change parameters
52 * Uplink on periodically
53 * Downlink to change configure
54 * IP66 Waterproof Enclosure
55 * Micro SIM card slot for NB-IoT SIM
56 * 8500mAh Battery for long term use
57
58
59 == 1.3  Specification ==
60
61
62 (% style="color:#037691" %)**Common DC Characteristics:**
63
64 * Supply Voltage: 2.1v ~~ 3.6v
65 * Operating Temperature: -40 ~~ 85°C
66
67 (% style="color:#037691" %)**NB-IoT Spec:**
68
69 * - B1 @H-FDD: 2100MHz
70 * - B3 @H-FDD: 1800MHz
71 * - B8 @H-FDD: 900MHz
72 * - B5 @H-FDD: 850MHz
73 * - B20 @H-FDD: 800MHz
74 * - B28 @H-FDD: 700MHz
75
76 (% style="color:#037691" %)**Battery:**
77
78 * Li/SOCI2 un-chargeable battery
79 * Capacity: 8500mAh
80 * Self Discharge: <1% / Year @ 25°C
81 * Max continuously current: 130mA
82 * Max boost current: 2A, 1 second
83
84 (% style="color:#037691" %)**Power Consumption**
85
86 * STOP Mode: 10uA @ 3.3v
87 * Max transmit power: [[350mA@3.3v>>mailto:350mA@3.3v]]
88
89
90
91 == ​1.4  Applications ==
92
93 * Smart Buildings & Home Automation
94 * Logistics and Supply Chain Management
95 * Smart Metering
96 * Smart Agriculture
97 * Smart Cities
98 * Smart Factory
99
100 (% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %)
101
102
103
104
105 == 1.5  Pin Definitions ==
106
107
108 [[image:1657328609906-564.png]]
109
110
111
112 = 2.  Use NDDS75 to communicate with IoT Server =
113
114 == 2.1  How it works ==
115
116 (((
117 The NDDS75 is equipped with a NB-IoT module, the pre-loaded firmware in NDDS75 will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by NDDS75.
118 )))
119
120
121 (((
122 The diagram below shows the working flow in default firmware of NDDS75:
123 )))
124
125 (((
126
127 )))
128
129 [[image:1657328659945-416.png]]
130
131 (((
132
133 )))
134
135
136 == 2.2 ​ Configure the NDDS75 ==
137
138
139 === 2.2.1 Test Requirement ===
140
141 (((
142 To use NDDS75 in your city, make sure meet below requirements:
143 )))
144
145 * Your local operator has already distributed a NB-IoT Network there.
146 * The local NB-IoT network used the band that NSE01 supports.
147 * Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
148
149 (((
150 Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.  The NDDS75 will use CoAP((% style="color:red" %)120.24.4.116:5683)(%%) or raw UDP((% style="color:red" %)120.24.4.116:5601)(%%) or MQTT((% style="color:red" %)120.24.4.116:1883)(%%)or TCP((% style="color:red" %)120.24.4.116:5600)(%%)protocol to send data to the test server
151 )))
152
153
154 [[image:1657328756309-230.png]]
155
156
157
158 === 2.2.2 Insert SIM card ===
159
160 (((
161 Insert the NB-IoT Card get from your provider.
162 )))
163
164 (((
165 User need to take out the NB-IoT module and insert the SIM card like below:
166 )))
167
168
169 [[image:1657328884227-504.png]]
170
171
172
173 === 2.2.3 Connect USB – TTL to NDDS75 to configure it ===
174
175 (((
176 (((
177 User need to configure NDDS75 via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic** (%%)to define where and how-to uplink packets. NDDS75 support AT Commands, user can use a USB to TTL adapter to connect to NDDS75 and use AT Commands to configure it, as below.
178 )))
179 )))
180
181 [[image:image-20220709092052-2.png]]
182
183 **Connection:**
184
185 (% style="background-color:yellow" %)USB TTL GND <~-~-~-~-> GND
186
187 (% style="background-color:yellow" %)USB TTL TXD <~-~-~-~-> UART_RXD
188
189 (% style="background-color:yellow" %)USB TTL RXD <~-~-~-~-> UART_TXD
190
191
192 In the PC, use below serial tool settings:
193
194 * Baud:  (% style="color:green" %)**9600**
195 * Data bits:** (% style="color:green" %)8(%%)**
196 * Stop bits: (% style="color:green" %)**1**
197 * Parity:  (% style="color:green" %)**None**
198 * Flow Control: (% style="color:green" %)**None**
199
200 (((
201 Make sure the switch is in FLASH position, then power on device by connecting the jumper on NDDS75. NDDS75 will output system info once power on as below, we can enter the (% style="color:green" %)**password: 12345678**(%%) to access AT Command input.
202 )))
203
204 [[image:1657329814315-101.png]]
205
206 (((
207 (% style="color:red" %)Note: the valid AT Commands can be found at: (%%)[[https:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NDDS75/>>url:https://www.dragino.com/downloads/index.php?dir=NB-IoT/NDDS75/]]
208 )))
209
210
211
212 === 2.2.4 Use CoAP protocol to uplink data ===
213
214 (% style="color:red" %)Note: if you don't have CoAP server, you can refer this link to set up one: (%%)[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]
215
216
217 **Use below commands:**
218
219 * (% style="color:blue" %)**AT+PRO=1**  (%%) ~/~/ Set to use CoAP protocol to uplink
220 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5683   ** (%%)~/~/ to set CoAP server address and port
221 * (% style="color:blue" %)**AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** (%%) ~/~/Set COAP resource path
222
223 For parameter description, please refer to AT command set
224
225 [[image:1657330452568-615.png]]
226
227
228 After configure the server address and (% style="color:green" %)**reset the device**(%%) (via AT+ATZ ), NDDS75 will start to uplink sensor values to CoAP server.
229
230 [[image:1657330472797-498.png]]
231
232
233
234 === 2.2.5 Use UDP protocol to uplink data(Default protocol) ===
235
236
237 * (% style="color:blue" %)**AT+PRO=2   ** (%%) ~/~/ Set to use UDP protocol to uplink
238 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/ to set UDP server address and port
239 * (% style="color:blue" %)**AT+CFM=1       ** (%%) ~/~/If the server does not respond, this command is unnecessary
240
241 [[image:1657330501006-241.png]]
242
243
244 [[image:1657330533775-472.png]]
245
246
247
248 === 2.2.6 Use MQTT protocol to uplink data ===
249
250
251 * (% style="color:blue" %)**AT+PRO=3   ** (%%) ~/~/Set to use MQTT protocol to uplink
252 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,1883   ** (%%) ~/~/Set MQTT server address and port
253 * (% style="color:blue" %)**AT+CLIENT=CLIENT       ** (%%)~/~/Set up the CLIENT of MQTT
254 * (% style="color:blue" %)**AT+UNAME=UNAME                               **(%%)~/~/Set the username of MQTT
255 * (% style="color:blue" %)**AT+PWD=PWD                                        **(%%)~/~/Set the password of MQTT
256 * (% style="color:blue" %)**AT+PUBTOPIC=NDDS75_PUB                 **(%%)~/~/Set the sending topic of MQTT
257 * (% style="color:blue" %)**AT+SUBTOPIC=NDDS75_SUB          **(%%) ~/~/Set the subscription topic of MQTT
258
259 [[image:1657249978444-674.png]]
260
261
262 [[image:1657330723006-866.png]]
263
264
265 (((
266 MQTT protocol has a much higher power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
267 )))
268
269
270
271 === 2.2.7 Use TCP protocol to uplink data ===
272
273
274 * (% style="color:blue" %)**AT+PRO=4   ** (%%) ~/~/ Set to use TCP protocol to uplink
275 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5600   **(%%) ~/~/ to set TCP server address and port
276
277 [[image:image-20220709093918-1.png]]
278
279
280 [[image:image-20220709093918-2.png]]
281
282
283
284 === 2.2.8 Change Update Interval ===
285
286 User can use below command to change the (% style="color:green" %)**uplink interval**.
287
288 * (% style="color:blue" %)**AT+TDC=600      ** (%%)~/~/ Set Update Interval to 600s
289
290 (((
291 (% style="color:red" %)**NOTE:**
292 )))
293
294 (((
295 (% style="color:red" %)1. By default, the device will send an uplink message every 1 hour.
296 )))
297
298
299
300 == 2.3  Uplink Payload ==
301
302 In this mode, uplink payload includes in total 14 bytes
303
304
305 (% border="1" cellspacing="10" style="background-color:#ffffcc; color:green; width:510px" %)
306 |=(% style="width: 60px;" %)(((
307 **Size(bytes)**
308 )))|=(% style="width: 50px;" %)**6**|=(% style="width: 25px;" %)2|=(% style="width: 25px;" %)**2**|=(% style="width: 70px;" %)**1**|=(% style="width: 60px;" %)**2**|=(% style="width: 50px;" %)**1**
309 |(% style="width:97px" %)**Value**|(% style="width:83px" %)[[Device ID>>||anchor="H2.4.1A0A0DeviceID"]]|(% style="width:41px" %)[[Ver>>||anchor="H2.4.2A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.4.3A0BatteryInfo"]]|(% style="width:123px" %)[[Signal Strength>>||anchor="H2.4.4A0SignalStrength"]]|(% style="width:108px" %)[[Distance (unit: mm)>>||anchor="H2.4.5A0SoilMoisture"]]|(% style="width:80px" %)[[Interrupt>>||anchor="H2.4.8A0DigitalInterrupt"]]
310
311 (((
312 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NDDS751 uplink data.
313 )))
314
315
316 [[image:1657331036973-987.png]]
317
318 (((
319 The payload is ASCII string, representative same HEX:
320 )))
321
322 (((
323 0x72403155615900640c6c19029200 where:
324 )))
325
326 * (((
327 Device ID: 0x724031556159 = 724031556159
328 )))
329 * (((
330 Version: 0x0064=100=1.0.0
331 )))
332
333 * (((
334 BAT: 0x0c6c = 3180 mV = 3.180V
335 )))
336 * (((
337 Signal: 0x19 = 25
338 )))
339 * (((
340 Distance: 0x0292= 658 mm
341 )))
342 * (((
343 Interrupt: 0x00 = 0
344 )))
345
346
347 == 2.4  Payload Explanation and Sensor Interface ==
348
349
350 === 2.4.1  Device ID ===
351
352 (((
353 By default, the Device ID equal to the last 6 bytes of IMEI.
354 )))
355
356 (((
357 User can use (% style="color:blue" %)**AT+DEUI**(%%) to set Device ID
358 )))
359
360 (((
361 **Example:**
362 )))
363
364 (((
365 AT+DEUI=A84041F15612
366 )))
367
368 (((
369 The Device ID is stored in a none-erase area, Upgrade the firmware or run **AT+FDR** won't erase Device ID.
370 )))
371
372
373
374 === 2.4.2  Version Info ===
375
376 (((
377 Specify the software version: 0x64=100, means firmware version 1.00.
378 )))
379
380 (((
381 For example: 0x00 64 : this device is NDDS75 with firmware version 1.0.0.
382 )))
383
384
385
386 === 2.4.3  Battery Info ===
387
388 (((
389 Check the battery voltage for LSE01.
390 )))
391
392 (((
393 Ex1: 0x0B45 = 2885mV
394 )))
395
396 (((
397 Ex2: 0x0B49 = 2889mV
398 )))
399
400
401
402 === 2.4.4  Signal Strength ===
403
404 (((
405 NB-IoT Network signal Strength.
406 )))
407
408 (((
409 **Ex1: 0x1d = 29**
410 )))
411
412 (((
413 (% style="color:blue" %)**0**(%%)  -113dBm or less
414 )))
415
416 (((
417 (% style="color:blue" %)**1**(%%)  -111dBm
418 )))
419
420 (((
421 (% style="color:blue" %)**2...30**(%%) -109dBm... -53dBm
422 )))
423
424 (((
425 (% style="color:blue" %)**31**  (%%) -51dBm or greater
426 )))
427
428 (((
429 (% style="color:blue" %)**99**   (%%) Not known or not detectable
430 )))
431
432
433
434 === 2.4.5  Soil Moisture ===
435
436 Get the distance. Flat object range 280mm - 7500mm.
437
438 For example, if the data you get from the register is **__0x0B 0x05__**, the distance between the sensor and the measured object is
439
440 (((
441 (((
442 (% style="color:blue" %)** 0B05(H) = 2821(D) = 2821mm.**
443 )))
444 )))
445
446 (((
447
448 )))
449
450 (((
451
452 )))
453
454 === 2.4.6  Digital Interrupt ===
455
456 (((
457 Digital Interrupt refers to pin (% style="color:blue" %)**GPIO_EXTI**(%%), and there are different trigger methods. When there is a trigger, the NDDS75 will send a packet to the server.
458 )))
459
460 (((
461 The command is:
462 )))
463
464 (((
465 (% style="color:blue" %)**AT+INTMOD=3 **(%%) ~/~/(more info about INMOD please refer [[**AT Command Manual**>>url:https://www.dragino.com/downloads/downloads/NB-IoT/NBSN95/DRAGINO_NBSN95-NB_AT%20Commands_v1.1.0.pdf]])**.**
466 )))
467
468
469 (((
470 The lower four bits of this data field shows if this packet is generated by interrupt or not. Click here for the hardware and software set up.
471 )))
472
473
474 (((
475 Example:
476 )))
477
478 (((
479 0x(00): Normal uplink packet.
480 )))
481
482 (((
483 0x(01): Interrupt Uplink Packet.
484 )))
485
486
487
488 === 2.4.7  ​+5V Output ===
489
490 (((
491 NDDS75 will enable +5V output before all sampling and disable the +5v after all sampling. 
492 )))
493
494
495 (((
496 The 5V output time can be controlled by AT Command.
497 )))
498
499 (((
500 (% style="color:blue" %)**AT+5VT=1000**
501 )))
502
503 (((
504 Means set 5V valid time to have 1000ms. So the real 5V output will actually have 1000ms + sampling time for other sensors.
505 )))
506
507
508
509 == 2.5  Downlink Payload ==
510
511 By default, NDDS75 prints the downlink payload to console port.
512
513 [[image:image-20220709100028-1.png]]
514
515
516 (((
517 (% style="color:blue" %)**Examples:**
518 )))
519
520 (((
521
522 )))
523
524 * (((
525 (% style="color:blue" %)**Set TDC**
526 )))
527
528 (((
529 If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
530 )))
531
532 (((
533 Payload:    01 00 00 1E    TDC=30S
534 )))
535
536 (((
537 Payload:    01 00 00 3C    TDC=60S
538 )))
539
540 (((
541
542 )))
543
544 * (((
545 (% style="color:blue" %)**Reset**
546 )))
547
548 (((
549 If payload = 0x04FF, it will reset the NDDS75
550 )))
551
552
553 * (% style="color:blue" %)**INTMOD**
554
555 (((
556 Downlink Payload: 06000003, Set AT+INTMOD=3
557 )))
558
559
560
561 == 2.6  ​LED Indicator ==
562
563
564 The NDDS75 has an internal LED which is to show the status of different state.
565
566
567 * When power on, NDDS75 will detect if sensor probe is connected, if probe detected, LED will blink four times. (no blinks in this step is no probe)
568 * Then the LED will be on for 1 second means device is boot normally.
569 * After NDDS75 join NB-IoT network. The LED will be ON for 3 seconds.
570 * For each uplink probe, LED will be on for 500ms.
571
572 (((
573
574 )))
575
576
577
578 == 2.7  Installation in Soil ==
579
580 __**Measurement the soil surface**__
581
582 (((
583 Choose the proper measuring position. Avoid the probe to touch rocks or hard things. Split the surface soil according to the measured deep. Keep the measured as original density. Vertical insert the probe into the soil to be measured. Make sure not shake when inserting. [[https:~~/~~/img.alicdn.com/imgextra/i3/2005165265/O1CN010rj9Oh1olPsQxrdUK_!!2005165265.jpg>>url:https://img.alicdn.com/imgextra/i3/2005165265/O1CN010rj9Oh1olPsQxrdUK_!!2005165265.jpg]]
584 )))
585
586 [[image:1657259653666-883.png]] ​
587
588
589 (((
590
591
592 (((
593 Dig a hole with diameter > 20CM.
594 )))
595
596 (((
597 Horizontal insert the probe to the soil and fill the hole for long term measurement.
598 )))
599 )))
600
601 [[image:1654506665940-119.png]]
602
603 (((
604
605 )))
606
607
608 == 2.8  ​Firmware Change Log ==
609
610
611 Download URL & Firmware Change log
612
613 [[www.dragino.com/downloads/index.php?dir=NB-IoT/NSE01/Firmware/>>url:http://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN50/Firmware/]]
614
615
616 Upgrade Instruction: [[Upgrade_Firmware>>||anchor="H5.1200BHowtoUpgradeFirmware"]]
617
618
619
620 == 2.9  ​Battery Analysis ==
621
622 === 2.9.1  ​Battery Type ===
623
624
625 (((
626 The NSE01 battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
627 )))
628
629
630 (((
631 The battery is designed to last for several years depends on the actually use environment and update interval. 
632 )))
633
634
635 (((
636 The battery related documents as below:
637 )))
638
639 * [[Battery Dimension>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
640 * [[Lithium-Thionyl Chloride Battery datasheet>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
641 * [[Lithium-ion Battery-Capacitor datasheet>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
642
643 (((
644 [[image:image-20220708140453-6.png]]
645 )))
646
647
648
649 === 2.9.2  Power consumption Analyze ===
650
651 (((
652 Dragino battery powered product are all runs in Low Power mode. We have an update battery calculator which base on the measurement of the real device. User can use this calculator to check the battery life and calculate the battery life if want to use different transmit interval.
653 )))
654
655
656 (((
657 Instruction to use as below:
658 )))
659
660 (((
661 (% style="color:blue" %)**Step 1:  **(%%)Downlink the up-to-date DRAGINO_Battery_Life_Prediction_Table.xlsx from: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/>>url:https://www.dragino.com/downloads/index.php?dir=LoRa_End_Node/Battery_Analyze/]]
662 )))
663
664
665 (((
666 (% style="color:blue" %)**Step 2: **(%%) Open it and choose
667 )))
668
669 * (((
670 Product Model
671 )))
672 * (((
673 Uplink Interval
674 )))
675 * (((
676 Working Mode
677 )))
678
679 (((
680 And the Life expectation in difference case will be shown on the right.
681 )))
682
683 [[image:image-20220708141352-7.jpeg]]
684
685
686
687 === 2.9.3  ​Battery Note ===
688
689 (((
690 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to transmit LoRa, then the battery life may be decreased.
691 )))
692
693
694
695 === 2.9.4  Replace the battery ===
696
697 (((
698 The default battery pack of NSE01 includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
699 )))
700
701
702
703 = 3. ​ Access NB-IoT Module =
704
705 (((
706 Users can directly access the AT command set of the NB-IoT module.
707 )))
708
709 (((
710 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
711 )))
712
713 [[image:1657261278785-153.png]]
714
715
716
717 = 4.  Using the AT Commands =
718
719 == 4.1  Access AT Commands ==
720
721 See this link for detail: [[http:~~/~~/www.dragino.com/downloads/index.php?dir=NB-IoT/NSE01/>>url:http://www.dragino.com/downloads/index.php?dir=NB-IoT/NBSN50/]]
722
723
724 AT+<CMD>?  : Help on <CMD>
725
726 AT+<CMD>         : Run <CMD>
727
728 AT+<CMD>=<value> : Set the value
729
730 AT+<CMD>=?  : Get the value
731
732
733 (% style="color:#037691" %)**General Commands**(%%)      
734
735 AT  : Attention       
736
737 AT?  : Short Help     
738
739 ATZ  : MCU Reset    
740
741 AT+TDC  : Application Data Transmission Interval
742
743 AT+CFG  : Print all configurations
744
745 AT+CFGMOD           : Working mode selection
746
747 AT+INTMOD            : Set the trigger interrupt mode
748
749 AT+5VT  : Set extend the time of 5V power  
750
751 AT+PRO  : Choose agreement
752
753 AT+WEIGRE  : Get weight or set weight to 0
754
755 AT+WEIGAP  : Get or Set the GapValue of weight
756
757 AT+RXDL  : Extend the sending and receiving time
758
759 AT+CNTFAC  : Get or set counting parameters
760
761 AT+SERVADDR  : Server Address
762
763
764 (% style="color:#037691" %)**COAP Management**      
765
766 AT+URI            : Resource parameters
767
768
769 (% style="color:#037691" %)**UDP Management**
770
771 AT+CFM          : Upload confirmation mode (only valid for UDP)
772
773
774 (% style="color:#037691" %)**MQTT Management**
775
776 AT+CLIENT               : Get or Set MQTT client
777
778 AT+UNAME  : Get or Set MQTT Username
779
780 AT+PWD                  : Get or Set MQTT password
781
782 AT+PUBTOPIC  : Get or Set MQTT publish topic
783
784 AT+SUBTOPIC  : Get or Set MQTT subscription topic
785
786
787 (% style="color:#037691" %)**Information**          
788
789 AT+FDR  : Factory Data Reset
790
791 AT+PWORD  : Serial Access Password
792
793
794
795 = ​5.  FAQ =
796
797 == 5.1 ​ How to Upgrade Firmware ==
798
799
800 (((
801 User can upgrade the firmware for 1) bug fix, 2) new feature release.
802 )))
803
804 (((
805 Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
806 )))
807
808 (((
809 (% style="color:red" %)Notice, NSE01 and LSE01 share the same mother board. They use the same connection and method to update.
810 )))
811
812
813
814 == 5.2  Can I calibrate NSE01 to different soil types? ==
815
816 (((
817 NSE01 is calibrated for saline-alkali soil and loamy soil. If users want to use it for other soil, they can calibrate the value in the IoT platform base on the value measured by saline-alkali soil and loamy soil. The formula can be found at [[this link>>https://www.dragino.com/downloads/downloads/LoRa_End_Node/LSE01/Calibrate_to_other_Soil_20220605.pdf]].
818 )))
819
820
821 = 6.  Trouble Shooting =
822
823 == 6.1  ​Connection problem when uploading firmware ==
824
825
826 (((
827 **Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
828 )))
829
830 (% class="wikigeneratedid" %)
831 (((
832
833 )))
834
835
836 == 6.2  AT Command input doesn't work ==
837
838 (((
839 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
840
841
842 )))
843
844
845 = 7. ​ Order Info =
846
847
848 Part Number**:** (% style="color:#4f81bd" %)**NSE01**
849
850
851 (% class="wikigeneratedid" %)
852 (((
853
854 )))
855
856 = 8.  Packing Info =
857
858 (((
859
860
861 (% style="color:#037691" %)**Package Includes**:
862
863 * NSE01 NB-IoT Soil Moisture & EC Sensor x 1
864 * External antenna x 1
865 )))
866
867 (((
868
869
870 (% style="color:#037691" %)**Dimension and weight**:
871
872 * Size: 195 x 125 x 55 mm
873 * Weight:   420g
874 )))
875
876 (((
877
878
879
880
881 )))
882
883 = 9.  Support =
884
885 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
886 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]