Version 125.5 by Xiaoling on 2022/09/09 16:02

Show last authors
1 (% style="text-align:center" %)
2 [[image:1657348034241-728.png||height="470" width="470"]]
3
4
5
6
7
8
9
10 **Table of Contents:**
11
12 {{toc/}}
13
14
15
16
17
18 = 1.  Introduction =
19
20
21 == 1.1 ​ What is N95S31B NB-IoT Sensor Node ==
22
23 (((
24
25
26 (((
27 The Dragino N95S31B is a (% style="color:blue" %)**NB-IoT Temperature and Humidity Sensor**(%%) for Internet of Things solution. It is used to measure the (% style="color:blue" %)**surrounding environment temperature and relative air humidity precisely**(%%), and then upload to IoT server via NB-IoT network*.
28 )))
29
30 (((
31 The temperature & humidity sensor used in N95S31B is SHT31, which is fully calibrated, linearized, and temperature compensated digital output from Sensirion, it provides a strong reliability and long-term stability. The SHT31 is fixed in a (% style="color:blue" %)**waterproof anti-condensation casing **(%%)for long term use.
32 )))
33
34 (((
35 N95S31B supports different uplink methods include (% style="color:blue" %)**TCP, MQTT, UDP and CoAP**(%%) for different application requirement.
36 )))
37
38 (((
39 N95S31B is powered by(% style="color:blue" %)**8500mAh Li-SOCI2 battery**(%%), It is designed for long term use up to several years. (Real-world battery life depends on the use environment, update period. Please check related Power Analyze report).
40 )))
41
42 (((
43
44 )))
45
46 (((
47 ~* make sure you have NB-IoT coverage locally.
48 )))
49
50
51 )))
52
53 [[image:1657348284168-431.png]]
54
55
56
57 == 1.2 ​ Features ==
58
59
60 * NB-IoT Bands: B1/B3/B8/B5/B20/B28 @H-FDD
61 * Monitor Temperature & Humidity via SHT31
62 * AT Commands to change parameters
63 * Uplink on periodically
64 * Downlink to change configure
65 * IP66 Waterproof Enclosure
66 * Ultra-Low Power consumption
67 * AT Commands to change parameters
68 * Micro SIM card slot for NB-IoT SIM
69 * 8500mAh Battery for long term use
70
71 == 1.3  Specification ==
72
73
74 (% style="color:#037691" %)**Common DC Characteristics:**
75
76 * Supply Voltage: 2.1v ~~ 3.6v
77 * Operating Temperature: -40 ~~ 85°C
78
79 (% style="color:#037691" %)**NB-IoT Spec:**
80
81 * - B1 @H-FDD: 2100MHz
82 * - B3 @H-FDD: 1800MHz
83 * - B8 @H-FDD: 900MHz
84 * - B5 @H-FDD: 850MHz
85 * - B20 @H-FDD: 800MHz
86 * - B28 @H-FDD: 700MHz
87
88 (% style="color:#037691" %)**Battery:**
89
90 * Li/SOCI2 un-chargeable battery
91 * Capacity: 8500mAh
92 * Self Discharge: <1% / Year @ 25°C
93 * Max continuously current: 130mA
94 * Max boost current: 2A, 1 second
95
96 == ​1.4  Applications ==
97
98
99 * Smart Buildings & Home Automation
100 * Logistics and Supply Chain Management
101 * Smart Metering
102 * Smart Agriculture
103 * Smart Cities
104 * Smart Factory
105
106 (% class="wikigeneratedid" id="H200B1.5FirmwareChangelog" %)
107
108
109
110
111
112 == 1.5  Pin Definitions & Switch ==
113
114
115 N95S31B use the mother board from NBSN95 which as below.
116
117
118 [[image:image-20220709144723-1.png]]
119
120
121
122 === 1.5.1 Jumper JP2 ===
123
124
125 Power on Device when put this jumper.
126
127
128
129 === 1.5.2 BOOT MODE / SW1 ===
130
131
132 (((
133 1) ISP: upgrade mode, device won't have any signal in this mode. but ready for upgrade firmware. LED won't work. Firmware won't run.
134 )))
135
136 (((
137 2) Flash: work mode, device starts to work and send out console output for further debug
138 )))
139
140
141
142 === 1.5.3 Reset Button ===
143
144
145 Press to reboot the device.
146
147
148
149 === 1.5.4 LED ===
150
151
152 It will flash:
153
154 1. When boot the device in flash mode
155 1. Send an uplink packet
156
157 = 2.  Use N95S31B to communicate with IoT Server =
158
159
160 == 2.1  How it works ==
161
162
163 (((
164 The N95S31B is equipped with a NB-IoT module, the pre-loaded firmware in N95S31B will get environment data from sensors and send the value to local NB-IoT network via the NB-IoT module.  The NB-IoT network will forward this value to IoT server via the protocol defined by N95S31B.
165 )))
166
167
168 (((
169 The diagram below shows the working flow in default firmware of N95S31B:
170 )))
171
172 (((
173
174 )))
175
176 [[image:1657520100595-569.png]]
177
178 (((
179
180 )))
181
182
183 == 2.2 ​ Configure the N95S31B ==
184
185
186 === 2.2.1  Power On N95S31B ===
187
188
189 [[image:image-20220709150546-2.png]]
190
191
192
193 === 2.2.1 Test Requirement ===
194
195
196 (((
197 To use N95S31B in your city, make sure meet below requirements:
198 )))
199
200 * (((
201 Your local operator has already distributed a NB-IoT Network there.
202 )))
203 * (((
204 The local NB-IoT network used the band that N95S31B supports.
205 )))
206 * (((
207 Your operator is able to distribute the data received in their NB-IoT network to your IoT server.
208 )))
209
210 (((
211 Below figure shows our testing structure. Here we have NB-IoT network coverage by China Mobile, the band they use is B8.
212 )))
213
214 (((
215 N95S31B supports different communication protocol such as :
216 )))
217
218 (((
219 * (((
220 CoAP  ((% style="color:red" %)120.24.4.116:5683(%%))
221 )))
222 * (((
223 raw UDP  ((% style="color:red" %)120.24.4.116:5601(%%))
224 )))
225 * (((
226 MQTT  ((% style="color:red" %)120.24.4.116:1883(%%))
227 )))
228 * (((
229 TCP  ((% style="color:red" %)120.24.4.116:5600(%%))
230 )))
231
232 (((
233 We will show how to use with each protocol. The IP addresses above are our test server. User need to change to point their corresponding server.
234 )))
235
236
237 )))
238
239 [[image:1657350625843-586.png]]
240
241
242
243 === 2.2.3  Insert SIM card ===
244
245
246 (((
247 Insert the NB-IoT Card get from your provider.
248 )))
249
250 (((
251 User need to take out the NB-IoT module and insert the SIM card like below:
252 )))
253
254
255 [[image:1657351240556-536.png]]
256
257
258
259 === 2.2.4  Connect USB – TTL to N95S31B to configure it ===
260
261
262 (((
263 (((
264 User need to configure N95S31B via serial port to set the (% style="color:blue" %)**Server Address** / **Uplink Topic** (%%)to define where and how-to uplink packets. N95S31B support AT Commands, user can use a USB to TTL adapter to connect to N95S31B and use AT Commands to configure it, as below.
265
266
267 )))
268 )))
269
270 [[image:1657351312545-300.png]]
271
272
273 **Connection:**
274
275 (% style="background-color:yellow" %)USB TTL GND <~-~-~-~-> GND
276
277 (% style="background-color:yellow" %)USB TTL TXD <~-~-~-~-> UART_RXD
278
279 (% style="background-color:yellow" %)USB TTL RXD <~-~-~-~-> UART_TXD
280
281
282 In the PC, use below serial tool settings:
283
284 * Baud:  (% style="color:green" %)**9600**
285 * Data bits:** (% style="color:green" %)8(%%)**
286 * Stop bits: (% style="color:green" %)**1**
287 * Parity:  (% style="color:green" %)**None**
288 * Flow Control: (% style="color:green" %)**None**
289
290 (((
291 Make sure the switch is in FLASH position, then power on device by connecting the jumper on N95S31B. N95S31B will output system info once power on as below, we can enter the (% style="color:green" %)**password: 12345678**(%%) to access AT Command input.
292 )))
293
294 [[image:1657329814315-101.png]]
295
296
297 (((
298 (% style="color:red" %)**Note: the valid AT Commands can be found at:  **(%%)**[[https:~~/~~/www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i~~-~~-AyZcQkoua?dl=0>>https://www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i--AyZcQkoua?dl=0]]**
299 )))
300
301
302
303 === 2.2.5  Use CoAP protocol to uplink data ===
304
305
306 (% style="color:red" %)**Note: if you don't have CoAP server, you can refer this link to set up one: **(%%)**[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/>>http://wiki.dragino.com/xwiki/bin/view/Main/Set%20up%20CoAP%20Server/]]**
307
308
309 (((
310 **Use below commands:**
311 )))
312
313 * (((
314 (% style="color:blue" %)**AT+PRO=1**  (%%) ~/~/ Set to use CoAP protocol to uplink
315 )))
316 * (((
317 (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5683   ** (%%)~/~/ to set CoAP server address and port
318 )))
319 * (((
320 (% style="color:blue" %)**AT+URI=5,11,"mqtt",11,"coap",12,"0",15,"c=text1",23,"0" ** (%%) ~/~/Set COAP resource path
321 )))
322
323 (((
324
325
326 For parameter description, please refer to AT command set
327 )))
328
329 [[image:1657352146020-183.png]]
330
331
332 (((
333 After configure the server address and (% style="color:green" %)**reset the device**(%%) (via AT+ATZ ), NDDS75 will start to uplink sensor values to CoAP server.
334 )))
335
336 [[image:1657352185396-303.png]]
337
338
339
340 === 2.2.6  Use UDP protocol to uplink data(Default protocol) ===
341
342
343 * (% style="color:blue" %)**AT+PRO=2   ** (%%) ~/~/ Set to use UDP protocol to uplink
344 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5601   ** (%%) ~/~/ to set UDP server address and port
345 * (% style="color:blue" %)**AT+CFM=1       ** (%%) ~/~/ If the server does not respond, this command is unnecessary
346
347 [[image:1657352391268-297.png]]
348
349
350 [[image:1657352403317-397.png]]
351
352
353
354 === 2.2.7  Use MQTT protocol to uplink data ===
355
356
357 N95S31B supports only plain MQTT now it doesn't support TLS and other related encryption.
358
359 * (% style="color:blue" %)**AT+PRO=3   ** (%%) ~/~/Set to use MQTT protocol to uplink
360 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,1883   ** (%%) ~/~/Set MQTT server address and port
361 * (% style="color:blue" %)**AT+CLIENT=CLIENT       ** (%%)~/~/Set up the CLIENT of MQTT
362 * (% style="color:blue" %)**AT+UNAME=UNAME                                **(%%)~/~/Set the username of MQTT
363 * (% style="color:blue" %)**AT+PWD=PWD                                         **(%%)~/~/Set the password of MQTT
364 * (% style="color:blue" %)**AT+PUBTOPIC=f9527                               **(%%)~/~/Set the sending topic of MQTT
365 * (% style="color:blue" %)**AT+SUBTOPIC=Ns9527          **(%%) ~/~/Set the subscription topic of MQTT
366
367 [[image:1657352634421-276.png]]
368
369
370 [[image:1657352645687-385.png]]
371
372
373 (((
374 To save battery life, N95S31B will establish a subscription before each uplink and close the subscription 3 seconds after uplink successful. Any downlink commands from server will only arrive during the subscription period.
375 )))
376
377
378 (((
379 MQTT protocol has a much high-power consumption compare vs UDP / CoAP protocol. Please check the power analyze document and adjust the uplink period to a suitable interval.
380 )))
381
382
383
384 === 2.2.8  Use TCP protocol to uplink data ===
385
386
387 This feature is supported since firmware version v110
388
389 * (% style="color:blue" %)**AT+PRO=4   ** (%%) ~/~/ Set to use TCP protocol to uplink
390 * (% style="color:blue" %)**AT+SERVADDR=120.24.4.116,5600   **(%%) ~/~/ to set TCP server address and port
391
392 [[image:1657352898400-901.png]]
393
394
395 [[image:1657352914475-252.png]]
396
397
398
399 === 2.2.9  Change Update Interval ===
400
401
402 User can use below command to change the (% style="color:green" %)**uplink interval**.
403
404 * (% style="color:blue" %)**AT+TDC=600      ** (%%)~/~/ Set Update Interval to 600s
405
406 (((
407
408 )))
409
410 (((
411 (% style="color:red" %)**NOTE: Since firmware version is v1.2:**
412 )))
413
414 (((
415 (% style="color:red" %)**By default, the device will send an uplink message every 2 hours. Each Uplink Include 8 set of records in this 2 hour (15 minute interval / record).**
416 )))
417
418
419
420 == 2.3  Uplink Payload ==
421
422
423 (((
424 N95S31B has different working modes for the connections of different types of sensors. This section describes these modes. User can use the AT Command (% style="color:blue" %)**AT+MOD**(%%) to set NBSN95 to different working modes.
425 )))
426
427
428 (((
429 For example:
430 )))
431
432 (((
433 (% style="color:blue" %)**AT+CFGMOD=2 ** (%%)~/~/will set the N95S31B to work in MOD=2 distance mode which target to measure distance via Ultrasonic Sensor.
434 )))
435
436
437 (((
438 The uplink payloads are composed in  ASCII String. For example:
439 )))
440
441 (((
442 0a cd 00 ed 0a cc 00 00 ef 02 d2 1d (total 24 ASCII Chars) . Representative the actually payload:
443 )))
444
445 (((
446 0x 0a cd 00 ed 0a cc 00 00 ef 02 d2 1d Total 12 bytes
447 )))
448
449
450 (((
451 (% style="color:red" %)**NOTE:**
452 )))
453
454 (% style="color:red" %)
455 1. (((
456 **All modes share the same Payload Explanation from [[HERE>>||anchor="H2.3A0UplinkPayload"]].**
457 )))
458 1. (((
459 **By default, the device will send an uplink message every 1 hour.**
460
461
462
463
464 )))
465
466 === 2.3.1  Payload Analyze ===
467
468
469 ==== 2.3.1.1  Before Firmware v1.2 ====
470
471
472 N95S31B uplink payload includes in total 21 bytes
473
474
475 (% border="2" cellspacing="10" style="background-color:#ffffcc; color:green; width:760px" %)
476 |=(% style="width: 60px;" %)(((
477 **Size(bytes)**
478 )))|=(% style="width: 65px;" %)**6**|=(% style="width: 50px;" %)2|=(% style="width: 25px;" %)**2**|=(% style="width: 75px;" %)**1**|=(% style="width: 59px;" %)1|=(% style="width: 174px;" %)5|=(% style="width: 106px;" %)**2**|=(% style="width: 85px;" %)**2**
479 |(% style="width:97px" %)**Value**|(% style="width:65px" %)[[Device ID>>||anchor="H2.3.2A0DeviceID"]]|(% style="width:50px" %)[[Ver>>||anchor="H2.3.3A0VersionInfo"]]|(% style="width:46px" %)[[BAT>>||anchor="H2.3.4A0BatteryInfo"]]|(% style="width:75px" %)[[Signal Strength>>||anchor="H2.3.5A0SignalStrength"]]|(% style="width:59px" %)MOD 0X01|(% style="width:174px" %)(((
480 (((
481 Reserve/ Same as NBSN95 CFGMOD=1
482 )))
483
484 (((
485 No function here.
486 )))
487 )))|(% style="width:106px" %)(((
488 (((
489 [[Temperature >>||anchor="H2.3.6A0Temperature26Humidity"]]
490 )))
491
492 (((
493 By SHT31
494 )))
495 )))|(% style="width:85px" %)(((
496 (((
497 [[Humidity>>||anchor="H2.3.6A0Temperature26Humidity"]]
498 )))
499
500 (((
501 By SHT31
502 )))
503 )))
504
505 (((
506
507
508 (((
509 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the NB sensor uplink data.
510 )))
511 )))
512
513
514 [[image:1657354294009-643.png]]
515
516
517 The payload is ASCII string, representative same HEX: 0x724031607457006e0ccd1b0100dc000ccc00e10186 where:
518
519 * Device ID:  0x724031607457 = 724031607457
520
521 * Version:  0x006e=110=1.1.0
522
523 * BAT:  0x0ccd = 3277 mV = 3.277V
524
525 * Signal:  0x1b = 27
526
527 * Model:  0x01 = 1
528
529 * 0x00dc000ccc= reserve, ignore in N95S31B
530
531 * Temperature by SHT31:  0x00e1 = 225 = 22.5 °C
532
533 * Humidity by SHT31:  0x0186 = 390 = 39.0 %rh
534
535 (((
536
537
538
539
540 )))
541
542 ==== 2.3.1.2 Since Firmware v1.2 ====
543
544
545 In this mode, uplink payload includes 91 bytes in total by default.
546
547 Each time the device uploads a data package, 8 sets of recorded data will be attached. Up to 32 sets of recorded data can be uploaded.
548
549
550 (% border="2" style="background-color:#ffffcc; color:green; width:1234px" %)
551 |(% style="width:95px" %)**Size(bytes)**|(% style="width:82px" %)**8**|(% style="width:43px" %)**2**|(% style="width:47px" %)**2**|(% style="width:124px" %)**1**|(% style="width:56px" %)**1**|(% style="width:109px" %)**2**|(% style="width:80px" %)**1**|(% style="width:51px" %)**2**|(% style="width:79px" %)**2**|(% style="width:84px" %)**2**|(% style="width:100px" %)**4**|(% style="width:76px" %)**2**|(% style="width:81px" %)**2**|(% style="width:121px" %)**4**
552 |(% style="width:95px" %)**Value**|(% style="width:82px" %)Device ID|(% style="width:43px" %)Ver|(% style="width:47px" %)BAT|(% style="width:124px" %)Signal Strength|(% style="width:56px" %)MOD|(% style="width:109px" %)TemDS18B20|(% style="width:80px" %)Interrupt|(% style="width:51px" %)ADC|(% style="width:79px" %)SHTTEM|(% style="width:84px" %)SHTHUM|(% style="width:100px" %)Time stamp |(% style="width:76px" %)SHTTEM|(% style="width:81px" %)SHTHUM|(% style="width:121px" %)Time stamp .....
553
554 If we use the MQTT client to subscribe to this MQTT topic, we can see the following information when the N95S31B uplink data.
555
556
557 [[image:image-20220908154949-1.png]]
558
559
560 The payload is ASCII string, representative same HEX:
561
562 0x(% style="color:red" %)f868411056758782(% style="color:blue" %)000c(% style="color:green" %)0d0f(% style="color:red" %)0c(% style="color:blue" %)01(% style="color:green" %)0000(% style="color:red" %)00**//0030//**(% style="color:blue" %)**//0114//**(% style="color:red" %)**//0231//**(% style="color:green" %)**//63199d3c//**0113023163199d12//**0113023163199c5e**//0112023763199baa//**0112023263199af6**//0111023b631999a7//**0112023b631998f3**//011202426319983f//**01110242631996eb**//(%%) where:
563
564 * (% style="color:red" %)Device ID: f868411056758782 = f868411056758782
565
566 * (% style="color:blue" %)Version: 0x000c=120=1.2
567
568 * (% style="color:green" %)BAT: 0x0d0f = 3343 mV = 3.343V
569
570 * (% style="color:red" %)Singal: 0x0c = 12
571
572 * (% style="color:blue" %)Mod: 0x01 = 1
573
574 * TemDS18B20: 0x0000= 0 = 0
575
576 * (% style="color:green" %)Interrupt: 0x00= 0
577
578 * (% style="color:green" %)adc: 0x0030= 48
579
580 * SHTTEM: 0x0114= 276 = 27.6
581
582 * SHTHUM:0x0231 =561=56.1%
583
584 * (% style="color:red" %)Time stamp : 0x6315537b =1662342011  ([[Unix Epoch Time>>url:http://www.epochconverter.com/]])
585
586 * (% style="color:red" %)SHTTEM,SHTHUM,Time stamp : 0113023163199d12
587
588 * 8 sets of recorded data: SHTTEM,SHTHUM,Time stamp : //**0113023163199c5e**//,.......
589
590
591
592 === 2.3.2  Device ID ===
593
594
595 (((
596 By default, the Device ID equal to the last 6 bytes of IMEI.
597 )))
598
599 (((
600 User can use (% style="color:blue" %)**AT+DEUI**(%%) to set Device ID
601
602
603 )))
604
605 (((
606 *
607 ** (% style="color:blue" %)Example:
608 )))
609
610 (((
611 AT+DEUI=A84041F15612
612 )))
613
614 (((
615 The Device ID is stored in a none-erase area, Upgrade the firmware or run (% style="color:blue" %)**AT+FDR**(%%) won't erase Device ID.
616
617
618 )))
619
620 (% style="color:red" %)**NOTE: When the firmware version is v1.2 and later firmware:**
621
622
623 By default, the Device ID equal to the last 15 bits of IMEI.
624
625 User can use ** (% style="color:blue" %)AT+DEUI(%%)** to set Device ID
626
627
628 *
629 ** (% style="color:blue" %)Example:
630
631 AT+DEUI=868411056754138
632
633
634
635 === 2.3.3  Version Info ===
636
637
638 (((
639 These bytes include the hardware and software version.
640 )))
641
642 (((
643 Higher byte: Specify hardware version: always 0x00 for N95S31B
644 )))
645
646 (((
647 Lower byte: Specify the software version: 0x6E=110, means firmware version 110
648 )))
649
650 (((
651
652 )))
653
654 (((
655 For example: 0x00 6E: this device is N95S31B with firmware version 110.
656 )))
657
658 (((
659
660 )))
661
662
663 === 2.3.4  Battery Info ===
664
665
666 (((
667 Ex1: 0x0B45 = 2885mV
668 )))
669
670 (((
671 Ex2: 0x0B49 = 2889mV
672 )))
673
674
675
676 === 2.3.5  Signal Strength ===
677
678
679 (((
680 NB-IoT Network signal Strength.
681 )))
682
683 (((
684 **Ex1: 0x1d = 29**
685 )))
686
687 (((
688 (% style="color:blue" %)**0**(%%)  -113dBm or less
689 )))
690
691 (((
692 (% style="color:blue" %)**1**(%%)  -111dBm
693 )))
694
695 (((
696 (% style="color:blue" %)**2...30**(%%) -109dBm... -53dBm
697 )))
698
699 (((
700 (% style="color:blue" %)**31**  (%%) -51dBm or greater
701 )))
702
703 (((
704 (% style="color:blue" %)**99**   (%%) Not known or not detectable
705 )))
706
707
708
709 === 2.3.6  Temperature & Humidity ===
710
711
712 The device will be able to get the SHT31 temperature and humidity data now and upload to IoT Server.
713
714 [[image:image-20220709161741-3.png]]
715
716
717 Convert the read byte to decimal and divide it by ten.
718
719
720 **Example:**
721
722 Temperature:  Read:00ec (H) = 236(D)  Value:  236 /10=23.6℃
723
724 Humidity:    Read:0295(H)=661(D)    Value:  661 / 10=66.1, So 66.1%
725
726
727
728 == 2.4  Downlink Payload ==
729
730
731 By default, N95S31B prints the downlink payload to console port.
732
733 [[image:image-20220709100028-1.png]]
734
735
736 (((
737 (% style="color:blue" %)**Examples:**
738 )))
739
740 (((
741
742 )))
743
744 * (((
745 (% style="color:blue" %)**Set TDC**
746 )))
747
748 (((
749 If the payload=0100003C, it means set the END Node's TDC to 0x00003C=60(S), while type code is 01.
750 )))
751
752 (((
753 Payload:    01 00 00 1E    TDC=30S
754 )))
755
756 (((
757 Payload:    01 00 00 3C    TDC=60S
758 )))
759
760 (((
761
762 )))
763
764 * (((
765 (% style="color:blue" %)**Reset**
766 )))
767
768 (((
769 If payload = 0x04FF, it will reset the N95S31B
770 )))
771
772
773 * (% style="color:blue" %)**INTMOD**
774
775 (((
776 Downlink Payload: 06000003, Set AT+INTMOD=3
777 )))
778
779
780
781 == 2.5  Humidity and Temperature alarm function ==
782
783
784 **~ (% style="color:blue" %)➢ AT Command:(%%)**
785
786
787 (% style="color:#037691" %)**AT+ SHHUM=min,max**
788
789
790 ² When min=0, and max≠0, Alarm higher than max
791
792 ² When min≠0, and max=0, Alarm lower than min
793
794 ² When min≠0 and max≠0, Alarm higher than max or lower than min
795
796
797 (% style="color:blue" %)**Example:**
798
799 AT+ SHHUM=50,80 ~/~/ Alarm when humidity lower than 50.
800
801
802 (% style="color:#037691" %)**AT+ SHTEMP=min,max**
803
804 ² When min=0, and max≠0, Alarm higher than max
805
806 ² When min≠0, and max=0, Alarm lower than min
807
808 ² When min≠0 and max≠0, Alarm higher than max or lower than min
809
810
811 **~ (% style="color:blue" %)Example:(%%)**
812
813 AT+ SHTEMP=20,30 ~/~/ Alarm when temperature lower than 20.
814
815
816
817 == 2.6 Set the number of data to be uploaded and the recording time ==
818
819
820 **~ (% style="color:blue" %)➢ AT Command:(%%)**
821
822 * (% style="color:#037691" %)**AT+TR=900**  (%%)~/~/  The unit is seconds, and the default is to record data once every 900 seconds.( The minimum can be set to 180 seconds)
823 * (% style="color:#037691" %)**AT+NOUD=8**  (%%)~/~/  The device uploads 8 sets of recorded data by default. Up to 32 sets of record data can be uploaded.
824
825
826
827
828 == 2.7 Read or Clear cached data ==
829
830
831 **~ (% style="color:blue" %)➢ AT Command:(%%)**
832
833 * (% style="color:#037691" %)**AT+CDP**  (%%) ~/~/ Read cached data
834 * (% style="color:#037691" %)**AT+CDP=0** (%%) ~/~/  Clear cached data
835
836
837
838 [[image:image-20220908163102-2.png]]
839
840
841
842 == 2.8  ​Battery Analysis ==
843
844
845 === 2.8.1  ​Battery Type ===
846
847
848 (((
849 The N95S31B battery is a combination of an 8500mAh Li/SOCI2 Battery and a Super Capacitor. The battery is none-rechargeable battery type with a low discharge rate (<2% per year). This type of battery is commonly used in IoT devices such as water meter.
850 )))
851
852 (((
853 The battery is designed to last for several years depends on the actually use environment and update interval. 
854 )))
855
856 (((
857 The battery related documents as below:
858 )))
859
860 * [[Battery Dimension>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
861 * [[Lithium-Thionyl Chloride Battery datasheet>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
862 * [[Lithium-ion Battery-Capacitor datasheet>>http://www.dragino.com/downloads/index.php?dir=datasheet/Battery/ER26500/]]
863
864 (((
865 [[image:image-20220709101450-2.png]]
866 )))
867
868
869
870 === 2.8.2  Power consumption Analyze ===
871
872
873 (((
874 The file **DRAGINO_N95S31B-Power-Analyzer.pdf** from [[https:~~/~~/www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i~~-~~-AyZcQkoua?dl=0>>https://www.dropbox.com/sh/mlpd6l05bogvaf6/AABwAJLMttqG7i--AyZcQkoua?dl=0]] describes a detail measurement to analyze the power consumption in different case. User can use it for design guideline for their project.
875 )))
876
877 (((
878
879 )))
880
881
882 === 2.8.3  ​Battery Note ===
883
884
885 (((
886 The Li-SICO battery is designed for small current / long period application. It is not good to use a high current, short period transmit method. The recommended minimum period for use of this battery is 5 minutes. If you use a shorter period time to uplink data, then the battery life may be decreased.
887 )))
888
889
890
891 === 2.8.4  Replace the battery ===
892
893
894 (((
895 You can change the battery in the N95S31B.The type of battery is not limited as long as the output is between 3v to 3.6v. On the main board, there is a diode (D1) between the battery and the main circuit. If you need to use a battery with less than 3.3v, please remove the D1 and shortcut the two pads of it so there won't be voltage drop between battery and main board.
896 )))
897
898
899 (((
900 The default battery pack of N95S31B includes a ER26500 plus super capacitor. If user can't find this pack locally, they can find ER26500 or equivalence without the SPC1520 capacitor, which will also work in most case. The SPC can enlarge the battery life for high frequency use (update period below 5 minutes).
901 )))
902
903
904
905 = 3. ​ Access NB-IoT Module =
906
907
908 (((
909 Users can directly access the AT command set of the NB-IoT module.
910 )))
911
912 (((
913 The AT Command set can refer the BC35-G NB-IoT Module AT Command: [[https:~~/~~/www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/>>url:https://www.dragino.com/downloads/index.php?dir=datasheet/other_vendors/BC35-G/]] 
914
915
916 )))
917
918 [[image:1657333200519-600.png]]
919
920
921
922 = 4.  Using the AT Commands =
923
924
925 == 4.1  Access AT Commands ==
926
927
928 See NBSN95 AT Command in this link for detail:  [[https:~~/~~/www.dropbox.com/sh/jao1xt9kw5r3yq4/AAAMpJkZzExF2JLbRWxGoQ9Na?dl=0>>https://www.dropbox.com/sh/jao1xt9kw5r3yq4/AAAMpJkZzExF2JLbRWxGoQ9Na?dl=0]]
929
930
931 AT+<CMD>?  : Help on <CMD>
932
933 AT+<CMD>         : Run <CMD>
934
935 AT+<CMD>=<value> : Set the value
936
937 AT+<CMD>=?  : Get the value
938
939
940 (% style="color:#037691" %)**General Commands**(%%)      
941
942 AT  : Attention       
943
944 AT?  : Short Help     
945
946 ATZ  : MCU Reset    
947
948 AT+TDC  : Application Data Transmission Interval
949
950 AT+CFG  : Print all configurations
951
952 AT+CFGMOD           : Working mode selection
953
954 AT+INTMOD            : Set the trigger interrupt mode
955
956 AT+5VT  : Set extend the time of 5V power  
957
958 AT+PRO  : Choose agreement
959
960 AT+WEIGRE  : Get weight or set weight to 0
961
962 AT+WEIGAP  : Get or Set the GapValue of weight
963
964 AT+RXDL  : Extend the sending and receiving time
965
966 AT+CNTFAC  : Get or set counting parameters
967
968 AT+SERVADDR  : Server Address
969
970 AT+TR      : Get or Set record time
971
972 AT+APN     : Get or set the APN
973
974 AT+FBAND   : Get or Set whether to automatically modify the frequency band
975
976 AT+DNSCFG  : Get or Set DNS Server
977
978 AT+GETSENSORVALUE   : Returns the current sensor measurement
979
980 AT+NOUD      : Get or Set the number of data to be uploaded
981
982 AT+CDP     : Read or Clear cached data
983
984 AT+SHTEMP: Get or Set alarm of temp
985
986 AT+SHHUM: Get or Set alarm of moisture
987
988 (% style="color:#037691" %)**COAP Management**      
989
990 AT+URI            : Resource parameters
991
992
993 (% style="color:#037691" %)**UDP Management**
994
995 AT+CFM          : Upload confirmation mode (only valid for UDP)
996
997
998 (% style="color:#037691" %)**MQTT Management**
999
1000 AT+CLIENT               : Get or Set MQTT client
1001
1002 AT+UNAME  : Get or Set MQTT Username
1003
1004 AT+PWD                  : Get or Set MQTT password
1005
1006 AT+PUBTOPIC  : Get or Set MQTT publish topic
1007
1008 AT+SUBTOPIC  : Get or Set MQTT subscription topic
1009
1010
1011 (% style="color:#037691" %)**Information**          
1012
1013 AT+FDR  : Factory Data Reset
1014
1015 AT+PWORD  : Serial Access Password
1016
1017
1018
1019 = ​5.  FAQ =
1020
1021
1022 == 5.1 ​ How to Upgrade Firmware ==
1023
1024
1025 (((
1026 User can upgrade the firmware for 1) bug fix, 2) new feature release.
1027 )))
1028
1029 (((
1030 Please see this link for how to upgrade:  [[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList>>http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H2.HardwareUpgradeMethodSupportList]]
1031 )))
1032
1033 (((
1034
1035
1036 (((
1037 (% style="color:red" %)**Notice, N95S31B and LSN50v2 share the same mother board. They use the same connection and method to update.**
1038 )))
1039 )))
1040
1041
1042
1043 = 6.  Trouble Shooting =
1044
1045
1046 == 6.1  ​Connection problem when uploading firmware ==
1047
1048
1049 (((
1050 **Please see: **[[http:~~/~~/wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting>>url:http://wiki.dragino.com/xwiki/bin/view/Main/Firmware%20Upgrade%20Instruction%20for%20STM32%20base%20products/#H3.3Troubleshooting]]
1051 )))
1052
1053 (% class="wikigeneratedid" %)
1054 (((
1055
1056 )))
1057
1058
1059 == 6.2  AT Command input doesn't work ==
1060
1061
1062 (((
1063 In the case if user can see the console output but can't type input to the device. Please check if you already include the (% style="color:green" %)**ENTER**(%%) while sending out the command. Some serial tool doesn't send (% style="color:green" %)**ENTER**(%%) while press the send key, user need to add ENTER in their string.
1064
1065
1066 )))
1067
1068
1069 = 7. ​ Order Info =
1070
1071
1072 Part Number**:** (% style="color:#4f81bd" %)**N95S31B-YY**
1073
1074
1075 (% class="wikigeneratedid" %)
1076 (((
1077
1078 )))
1079
1080 = 8.  Packing Info =
1081
1082 (((
1083
1084
1085 (% style="color:#037691" %)**Package Includes**:
1086
1087 * N95S31B NB-IoT Temperature and Humidity Sensor
1088 * External antenna x 1
1089 )))
1090
1091 (((
1092
1093
1094 (% style="color:#037691" %)**Dimension and weight**:
1095
1096 * Device Size: 13.0 x 5 x 4.5 cm
1097 * Device Weight: 150g
1098 * Package Size / pcs : 14.0 x 8x 5 cm
1099 * Weight / pcs : 180g
1100 )))
1101
1102 (((
1103
1104
1105
1106
1107 )))
1108
1109 = 9.  Support =
1110
1111
1112 * Support is provided Monday to Friday, from 09:00 to 18:00 GMT+8. Due to different timezones we cannot offer live support. However, your questions will be answered as soon as possible in the before-mentioned schedule.
1113 * Provide as much information as possible regarding your enquiry (product models, accurately describe your problem and steps to replicate it etc) and send a mail to [[support@dragino.com>>url:http://../../../../../../D:%5C%E5%B8%82%E5%9C%BA%E8%B5%84%E6%96%99%5C%E8%AF%B4%E6%98%8E%E4%B9%A6%5CLoRa%5CLT%E7%B3%BB%E5%88%97%5Csupport@dragino.com]]
1114
1115